ASTM D5800-2014e1 7976 Standard Test Method for Evaporation Loss of Lubricating Oils by the Noack Method《采用Noack法的润滑油蒸发损耗的标准试验方法》.pdf

上传人:figureissue185 文档编号:520747 上传时间:2018-12-03 格式:PDF 页数:19 大小:418.49KB
下载 相关 举报
ASTM D5800-2014e1 7976 Standard Test Method for Evaporation Loss of Lubricating Oils by the Noack Method《采用Noack法的润滑油蒸发损耗的标准试验方法》.pdf_第1页
第1页 / 共19页
ASTM D5800-2014e1 7976 Standard Test Method for Evaporation Loss of Lubricating Oils by the Noack Method《采用Noack法的润滑油蒸发损耗的标准试验方法》.pdf_第2页
第2页 / 共19页
ASTM D5800-2014e1 7976 Standard Test Method for Evaporation Loss of Lubricating Oils by the Noack Method《采用Noack法的润滑油蒸发损耗的标准试验方法》.pdf_第3页
第3页 / 共19页
ASTM D5800-2014e1 7976 Standard Test Method for Evaporation Loss of Lubricating Oils by the Noack Method《采用Noack法的润滑油蒸发损耗的标准试验方法》.pdf_第4页
第4页 / 共19页
ASTM D5800-2014e1 7976 Standard Test Method for Evaporation Loss of Lubricating Oils by the Noack Method《采用Noack法的润滑油蒸发损耗的标准试验方法》.pdf_第5页
第5页 / 共19页
亲,该文档总共19页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: D5800 141Standard Test Method forEvaporation Loss of Lubricating Oils by the Noack Method1This standard is issued under the fixed designation D5800; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revi

2、sion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEEq 11 was corrected editorially in January 2015.1. Scope*1.1 This test method covers three procedures for determin-ing the evaporation

3、 loss of lubricating oils (particularly engineoils). Procedure A uses the Noack evaporative tester equip-ment; Procedure B uses the automated non-Woods metalNoack evaporative apparatus; and Procedure C uses Selby-Noack volatility test equipment. The test method relates to oneset of operating conditi

4、ons but may be readily adapted to otherconditions when required.1.2 Noack results determined using Procedures A and Bshow consistent differences. Procedure A gives slightly lowerresults versus Procedure B on formulated engine oils, whileProcedure A gives higher results versus Procedure B onbasestock

5、s.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish ap

6、pro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD4177 Practice for Automatic Sampling of Petroleum andPetroleum ProductsD6299

7、 Practice for Applying Statistical Quality Assuranceand Control Charting Techniques to Evaluate AnalyticalMeasurement System PerformanceD6300 Practice for Determination of Precision and BiasData for Use in Test Methods for Petroleum Products andLubricants2.2 DIN Standards:3DIN 1725 Specification for

8、 Aluminum AlloysDIN 12785 Specifications for Glass Thermometers3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 evaporation lossof a lubricating oil by the Noackmethod, that mass of volatile oil vapors lost when the oil isheated in a test crucible through which a constant flow

9、of air isdrawn.3.1.2 volatility, nthe tendency of a liquid to form a vapor.4. Summary of Test Method4.1 A measured quantity of sample is placed in an evapo-ration crucible or reaction flask that is then heated to 250Cwith a constant flow of air drawn through it for 60 min. Theloss in mass of the oil

10、 is determined.4.2 Interlaboratory tests have shown that Procedure A,Procedure B, and Procedure C yield essentially equivalentresults, with a correlation coefficient of R2= 0.996. See theresearch report for the Selby-Noack interlaboratory study.5. Significance and Use5.1 The evaporation loss is of p

11、articular importance inengine lubrication. Where high temperatures occur, portions ofan oil can evaporate.5.2 Evaporation may contribute to oil consumption in anengine and can lead to a change in the properties of an oil.5.3 Many engine manufacturers specify a maximum allow-able evaporation loss.5.4

12、 Some engine manufacturers, when specifying a maxi-mum allowable evaporation loss, quote this test method alongwith the specifications.1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricants and is the direct responsibility ofSubcommittee

13、D02.06 on Analysis of Liquid Fuels and Lubricants.Current edition approved Oct. 1, 2014. Published October 2014. Originallyapproved in 1995. Last previous edition approved in 2008 as D5800 10. DOI:10.1520/D5800-14E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact AST

14、M Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Deutsches Institut fr Normunge, Beuth Verlag GmbH, Burg-grafen Strasse 6, 1000 Berlin 30, Germany.*A Summary of Changes section

15、appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.5 Procedure C, using the Selby-Noack apparatus, alsopermits collection of the volatile oil vapors for determinationof their physical and chemical pro

16、perties. Elemental analysis ofthe collected volatiles may be helpful in identifying compo-nents such as phosphorous, which has been linked to prematuredegradation of the emission system catalyst.Procedure A6. Apparatus6.1 Noack Evaporative Tester, comprising the following:6.1.1 Electrically Heated B

17、lock Unit, made from a mal-leable aluminum alloy (see DIN 1725, Sheet 1), insulated at thejacket and base against loss of heat. (WarningThis block isheated to 250C.) The block is heated electrically by a base andjacket heater, having a total power consumption of 1 to 1.2 kW.In this respect the diffe

18、rence between both individual powerconsumption should not exceed 0.15 kW. In the center of theheating block, there is a circular recess to insert the evaporatingcrucible, the space between block and crucible being filled withWoods alloy or a suitable equivalent. Two catches on the blockprevent the c

19、rucible from rising in the liquid metal bath. Twoadditional circular recesses at equal intervals from the center ofthe block are provided for the thermometers (see Fig. 1).6.1.2 Evaporating Crucible, with screw cover. The crucibleis made of stainless steel (see Fig. 2). Above the support ringis the

20、thread for the cover. The nickel-plated brass cover ishermetically sealed to the crucible by an internal conicalsealing surface (see Fig. 3). Three nozzles of hardened steelpermit the air stream to pass through the cover. The extractiontube, which slopes downward, leads from a threaded and sealedcon

21、nection in the center of the cover.6.2 Balance, capable of weighing at least 200 g to thenearest 0.01 g.6.3 Crucible Clamp and Spanner.6.4 Reamer, 2-mm diameter.6.5 Ball Bearing, 3.5-mm diameter.6.6 Thermometer, M260 (see DIN 12785) or temperaturesensing device capable of reading temperature to 0.1C

22、. Thethermometer should be calibrated with appropriate procedureat appropriate frequency (generally every six months).6.7 Contact Type Control Thermometer (for manual).6.8 Glass Y-piece, an internal diameter of 4 mm.The uprightarms, each 45-mm long, should form an angle such that the armconnected to

23、 the crucible extraction tube and the Y-piece forma straight line. The vertical arm is 60-mm long and beveled at45.6.9 Glass Delivery Tubes, an internal diameter of 4 mm,each arm length 100 mm, beveled at 45 at ends entering andleaving the bottles.6.9.1 Bent at an angle of approximately 80.6.9.2 Ben

24、t at an angle of approximately 100, length to 20mm of bottle base.6.9.3 Bent at an angle of approximately 90.6.10 Two Glass Bottles, approximately 2-L capacity, fittedwith rubber bungs bored to receive inlet and outlet tubes (seeFig. 4).6.11 Manometer, inclined form, water-filled, precision 0.2mm H2

25、O or suitable pressure sensor capable of measuring 206 0.2 mm of H2O (a 0 to 50-mm H2O pressure transducer hasbeen found to be satisfactory).NOTE 1Some manometers use water as the reference fluid, others mayuse a lower density fluid correlated to read in millimetres of water. Usersshould ensure that

26、 the manometer is filled with the correct densityreference fluid.6.12 Glass T-Piece, with bleed valve attached.6.13 Vacuum Pump.6.14 Timer, with accuracy of 0.2 s.6.15 Silicone Rubber Tubing, cut to size, with an internaldiameter of 4 mm.6.15.1 40-mm long; three pieces required,6.15.2 300-mm long, a

27、nd6.15.3 100-mm long.NOTE 2The use of automated equipment is permissible as long as itgives equivalent results specified in this test method. All hardwaredimensions, make-up of the block, crucible, heat capacity, and so forth,and glassware must conform to the specifications given in this testmethod.

28、7. Reagents and Materials7.1 Cleaning SolventA mixture of naphtha and toluene isrecommended for the cleaning of the crucible. (WarningFlammable, vapor harmful.) Overnight soaking may be neces-sary.7.2 Oils having a known evaporative loss, the value ofwhich is provided by the oil supplier. Some examp

29、les of suchoils include RL-N, RL 172, and RL 223, supplied by CEC.Other oils supplied by other vendors may also be used.7.3 Insulated Gloves.7.4 Paint Brush, such as a tinnerps acid brush (15 to 25-mmwidth).7.5 Woods Metal4or Suitable Heat Transfer Material(WarningWoods metal contains lead (25 %), b

30、ismuth(50 %), antimony (12.5 %), and cadmium (12.5 %); these havebeen found to be health hazardous. Avoid contact with skin atall times.)8. Hazards8.1 Safety HazardsIt is assumed that anyone using thistest method will either be fully trained and familiar with allnormal laboratory practices, or will

31、be under the direct super-vision of such a person. It is the responsibility of the operatorto ensure that all local legislative and statutory requirementsare met.4The sole source of supply of Woods metal known to the committee at this timeis Sigma-Aldrich, Customer Support, P.O. Box 14508, St. Louis

32、, MO 63178. If youare aware of alternative suppliers, please provide this information to ASTMInternational Headquarters. Your comments will receive careful consideration at ameeting of the responsible technical committee,1which you may attend.D5800 1412NOTE 1All dimensions in millilitres.FIG. 1 Heat

33、ing BlockD5800 14138.2 (WarningThough the test method calls for a draft-free area, the exhaust fumes from the evaporating oil must beventilated to an outside source. Precaution shall be taken toavoid any possibility of fire or explosion.)NOTE 3One way to achieve a draftfree environment and greatersa

34、fety in operation for the instruments used in this test method is describedin Appendix X3.8.3 An alternate means for preventing draft described inAppendix X3 was not used in the development of the testmethod precision statement.9. Preparation of Apparatus9.1 Astandard assembly of the apparatus is sh

35、own in Fig. 5.To avoid disturbing the thermal equilibrium, the apparatusshall be assembled in a draftfree area and comply with Fig. 5in dimensions and apparatus. (See 8.2.)9.2 Add sufficient Woods metal or equivalent material to therecesses of the heating block so that, with the crucible andthermome

36、ter in place, the remaining spaces will be filled withthe molten metal.9.3 Using the highest heating rate possible, raise the tem-perature of the heating block until the Woods metal is molten.Insert the thermometers with their bulbs touching the bottom ofthe recesses, and ensure that the contact the

37、rmometer isplugged in the back of the heating block. Adjust the powersupplied to the heating block so that the temperature can bemaintained at 250 6 0.5C.9.4 Assemble the remaining apparatus, less the crucible, asshown in Fig. 5.9.5 Place an empty crucible in the heating block, securingthe flange un

38、der the screw heads against the buoyancy of theWoods metal. The level of the molten metal should be such thata trace of it can be seen at the flange of the crucible and the topof the heating block.9.6 Check that the readings can be obtained on the manom-eter scale, or other measuring device, by conn

39、ecting thecrucible to the assembled apparatus. A reading of 20.0 6 0.2mm shall be obtained.9.7 Disconnect and remove the crucible from the assembledapparatus.9.8 Switch off the pump and the heating block and raise thecrucible and the thermometers from the molten Woods metal.Using the brush, return a

40、ny Woods metal clinging to thecrucible to the heating block.9.9 Clean the Y-piece and glass tubing to prevent a build upof condensate.NOTE 1All dimensions in millilitres.FIG. 2 CrucibleNOTE 1All dimensions in millilitres.FIG. 3 CoverD5800 141410. Verification10.1 Switch on the pump and the heating b

41、lock and ensurethat the apparatus is assembled, minus the crucible, as shownin Fig. 5.10.2 Check that the crucible and cover are free from lacquer.10.2.1 After every test, clean the crucible and cover withsolvent and allow to dry. Stubborn lacquer can be cleaned byabrasion from a glass beader under

42、pressure.10.3 Pass the reamer through each of the three nozzles in thecover to ensure that they are clear. (WarningUsing a reamerwith a diameter larger than 2 mm can enlarge the nozzles. Thiscan lead to higher losses because of increased air flow.)10.4 Run the ball bearing through the extraction tub

43、e toensure that it is clear of dirt.10.5 Weigh the empty crucible without its cover to thenearest 0.01 g.10.6 Weigh into the crucible 65.0 6 0.1 g of the ReferenceOil.10.7 Screw on the cover using the clamp and spanner.10.8 Ensure the temperature of the heating block is at 250 60.5C. Place the cruci

44、ble in its recess in the heating block,securing the flange under the screw heads against the buoyancyof the Woods metal. Switch the control of the heating block tocompensate for the heat capacity of the crucible. Immediately(in less than 5 s), connect the extraction tube of the crucible tothe arm of

45、 the glass Y-piece, making a butt joint.Simultaneously, start the pump and the stopwatch and adjustthe bleed valve to give a pressure differential of 20 6 0.2 mm.NOTE 4When the crucible is in the test position, its flange should beflush with the top of the heating block. Any protrusion of the crucib

46、leflange above the heating block may suggest a buildup of Woods metal slagat the bottom of the heating block recess. The heating block and thethermometer recesses should be cleaned and the Woods metal replaced ona regular basis to avoid the accumulation of slag. Oxidized Woods metalwill affect the h

47、eat transfer to the crucible and hence may have adeleterious effect on the results obtained.10.9 Adjust the control on the heating block to maintain theblock temperature approximately 5C below the test tempera-ture. Readjust the temperature control so that the test tempera-ture is reestablished with

48、in 3 min of the start of the test.NOTE 5Temperature and pressure will be controlled automaticallywhen automated equipment is used.10.10 At the start of the test, constant attention shall be paidto maintaining the correct pressure. Once this becomes steady,usually within 10 to 15 min, check periodica

49、lly that thetemperature and pressure differential remain constant through-out the period of the test.10.11 After 60 min 6 5 s, lift the crucible from the heatingblock, remove any adhering alloy, and place the crucible in awarm water bath to a depth of at least 30 mm. The time periodfrom the end of the test to immersion of the crucible shall notexceed 60 s.10.12 After 30 min, remove the crucible from the water, drythe outside, and carefully remove the lid.10.13 Reweigh the crucible without the lid to the nearest0.01 g.10.14 Calculate to the

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1