ASTM D5902-2005(2015) 4848 Standard Test Method for Rubber&x2014 Determination of Residual Unsaturation in Hydrogenated Nitrile Rubber (HNBR) by Iodine Value《橡胶的标准试验方法 使用红外分光光度法测定氢.pdf

上传人:brainfellow396 文档编号:521018 上传时间:2018-12-03 格式:PDF 页数:3 大小:69.09KB
下载 相关 举报
ASTM D5902-2005(2015) 4848 Standard Test Method for Rubber&x2014 Determination of Residual Unsaturation in Hydrogenated Nitrile Rubber (HNBR) by Iodine Value《橡胶的标准试验方法 使用红外分光光度法测定氢.pdf_第1页
第1页 / 共3页
ASTM D5902-2005(2015) 4848 Standard Test Method for Rubber&x2014 Determination of Residual Unsaturation in Hydrogenated Nitrile Rubber (HNBR) by Iodine Value《橡胶的标准试验方法 使用红外分光光度法测定氢.pdf_第2页
第2页 / 共3页
ASTM D5902-2005(2015) 4848 Standard Test Method for Rubber&x2014 Determination of Residual Unsaturation in Hydrogenated Nitrile Rubber (HNBR) by Iodine Value《橡胶的标准试验方法 使用红外分光光度法测定氢.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: D5902 05 (Reapproved 2015)Standard Test Method forRubberDetermination of Residual Unsaturation inHydrogenated Nitrile Rubber (HNBR) by Iodine Value1This standard is issued under the fixed designation D5902; the number immediately following the designation indicates the year oforiginal a

2、doption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the Wiijs procedure for thedetermination of u

3、nsaturation (iodine value) in hydrogenatednitrile rubbers.1.2 This test method is applicable only to those hydroge-nated nitrile rubbers derived from copolymers of acrylonitrileand butadiene.1.3 Iodine values are reported in centigrams of iodine pergram of HNBR cg(I2)/g. Higher iodine values indicat

4、e higherlevels of unsaturation.1.4 This test method is appropriate for calculating thepercent residual unsaturation of hydrogenated nitrile rubber ifthe iodine value of the base polymer before hydrogenation hasbeen determined.1.5 The values stated in SI units are to be regarded asstandard. No other

5、units of measurement are included in thisstandard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of r

6、egulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterD1959 Test Method for Iodine Value of Drying Oils andFatty Acids (Withdrawn 2006)3D4483 Practice for Evaluating Precision for Test MethodStandards in the Rubber and Carbon Black Manufac

7、turingIndustries3. Summary of Test Method3.1 Asample of the raw, unvulcanized rubber is dissolved inchloroform.3.2 The dissolved sample is reacted with Wiijs solution.3.3 When the reaction is completed, potassium iodide solu-tion is added.3.4 The resultant solution is then back-titrated with sodiumt

8、hiosulfate solution and the iodine value is calculated.4. Significance and Use4.1 Hydrogenated nitrile rubbers are available at differentlevels of unsaturation and different acrylonitrile content.Highly saturated grades offer optimum resistance to aging,such as exposure to heat, ozone and chemicals,

9、 and can becured effectively only with peroxides or high energy radiation.4.2 Partially unsaturated grades can be cured by sulfursystems in addition to peroxides and high energy radiation.4.3 This test method provides a technique to determine theunsaturation level of hydrogenated nitrile rubbers in

10、the raw,unvulcanized state. It can be used for research anddevelopment, quality control, and referee purposes.5. Apparatus5.1 Erlenmeyer Flasks, with ground glass stoppers (300mL).5.2 Flask Shaker.5.3 Pipets.5.4 Constant Temperature Bath.6. Reagents6.1 Reagent grade chemicals shall be used in all te

11、sts. Allreagents shall conform to the specifications of the Committeeon Analytical Reagents of the American Chemical Society.41This test method is under the jurisdiction of ASTM Committee D11 on Rubberand is the direct responsibility of Subcommittee D11.11 on Chemical Analysis.Current edition approv

12、ed June 1, 2015. Published September 2015. Originallyapproved in 1996. Last previous edition approved in 2010 as D5902 05 (2010).DOI: 10.1520/D5902-05R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMS

13、tandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.4Reagent Chemicals, American Chemical Society Specifications, AmericanChemical Society, Washington, DC. For Suggestions on

14、the testing of reagents notlisted by the American Chemical Society, see Annual Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmacopeial Convention, Inc. (USPC), Rockville,MD.Copyright ASTM International, 100 Barr H

15、arbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1Other grades may be used, provided it is first ascertained thatthe reagent is of sufficiently high purity to permit its usewithout lessening the accuracy of the determination.6.2 Purity of WaterUnless otherwise indicated, refe

16、rencesto water shall be understood to mean reagent water conformingto Type I of Specification D1193.6.3 Chloroform.6.4 Wiijs Solution (prepared in accordance with Test MethodD1959).6.5 Potassium Iodide Solution (prepared in accordance withTest Method D1959).6.6 0.1 N Sodium Thiosulfate Solution (pre

17、pared in accor-dance with Test Method D1959).6.7 Starch Indicator Solution (prepared in accordance withTest Method D1959).7. Procedure7.1 If the approximate level of unsaturation is known, thefollowing sample sizes are recommended:Approximate unsaturation level Sample weight in mg2 % 9309705 % 68072

18、010 % 430470If the approximate level of unsaturation is unknown, asample weight of 680720 mg is recommended.7.2 Weigh the finely divided sample to the nearest 0.1 mg.Add the sample to a 300-mL glass stoppered Erlenmeyer flaskcontaining 50 mL of chloroform. Using the flask shaker, shakeuntil the samp

19、les are completely dissolved in the chloroform(approximately 1 h).7.3 Immediately place the flask containing the dissolvedsample into a constant temperature bath maintained at 23 6 1C for 30 min.7.4 Pipet 25 cm3of Wiijs solution into the flask containingthe specimen while shaking the flask. Replace

20、the glass stopperand return the flask to the constant temperature bath maintainedat 23 6 1Cfor2h.7.5 Remove the flask from the constant temperature bathand quickly add 10 cm3of potassium iodide solution whileshaking the flask vigorously.7.6 Wash off any iodine from the stopper into the flask withdis

21、tilled water. Wait 5 min before beginning the titration.7.7 Titrate with the 0.1 N sodium thiosulfate solution,adding it gradually while shaking the flask vigorously. Con-tinue the titration until the yellow coloring is just about todisappear. Add 1 to 2 cm3of starch indicator solution andcontinue t

22、he titration until the violet color just disappears.7.8 Allow the flask to stand for 30 min after the titration,then shake the flask, and if color returns, continue the titration.7.9 Run a blank determination following the titration stepsas described in 7.2 through 7.8 concurrently with the sampleun

23、der test.8. Calculation8.1 Calculate the iodine value as follows:Iodine value 50.1 3 f 3 B 2 A! 3126.9 31001000 3 M(1)50.1 3 f 3 B 2 A! 312.69Mwhere:f = normality factor of the 0.1 N sodium thiosulfatesolution,A =cm3of sodium thiosulfate solution required fortitration of the sample,B =cm3of sodium t

24、hiosulfate solution required fortitration of the blank,M = mass of the sample in grams,126.9 = atomic mass of iodine,1000 = conversion factor from the mg equivalent of so-dium thiosulfate to the g equivalent, and100 = conversion factor from g to cg.8.2 Calculate the percent of residual unsaturation

25、if theiodine value of the base polymer prior to hydrogenation isknown, as follows:% Residual unsaturation (2)5Iodine value measuredIodine value of the base polymer31009. Report9.1 The report shall include the following information:9.1.1 Proper sample identification,9.1.2 Number of data points used t

26、o obtain the result,9.1.3 The iodine value obtained, and9.1.4 The percent of residual unsaturation to the nearest0.1 %, if applicable.10. Precision and Bias510.1 This precision and bias section has been prepared inaccordance with Practice D4483. Refer to Practice D4483 forterminology and other stati

27、stical calculation details.10.2 PrecisionThe precision results in this precision andbias section give an estimate of the precision of this testmethod with the materials (rubbers) used in the particularinterlaboratory program as described in 10.3 and 10.4. Theprecision parameters should not be used f

28、or acceptance/rejection testing of any group of materials without documen-tation that they are applicable to those particular materials andthe specific testing protocols that include this test method.10.3 A Type I/Class II interlaboratory precision was evalu-ated. Both repeatability and reproducibil

29、ity are short term. Aperiod of one week separates replicate test results. Eachdetermination (measurement) is a test result.10.4 Three different materials (grades of hydrogenated ni-trile rubber) with different degrees of unsaturation were used in5Supporting data have been filed at ASTM International

30、 Headquarters and maybe obtained by requesting Research Report RR: D11-1078.D5902 05 (2015)2the interlaboratory program. These materials were tested infour laboratories on two different days one week apart.Duplicate tests were run on each day. The analysis for precisionfollowed the general procedure

31、 as set forth in Annex ofPractice D4483. Each cell of Table A5.1 in Practice D4483contained four values (two test days, two results each day). Theestimates for repeatability parameters contain two undifferen-tiated sources of variation, replicates within days and betweendays. The final precision par

32、ameters are given in Table 1.10.5 The precision of this test method may be expressed inthe format of the following statements that use what is calledan “appropriate value” of r, R,(r)or(R), that is, that valueobtained from Table 1 to be used in decisions about test resultsof this test method.10.6 Re

33、peatabilityThe repeatability of this test methodhas been established as the appropriate value for any parameteras tabulated in Table 1. Two single test results obtained in thesame laboratory, under normal test method procedures, thatdiffer by more than this tabulated r must be considered asderived f

34、rom different or nonidentical sample populations.10.7 Reproducibility, R, of this test method has been estab-lished as the appropriate value for any parameter as tabulatedin Table 1. Two single test results obtained in two differentlaboratories, under normal test method procedures, that differby mor

35、e than this tabulated R must be considered as derivedfrom different or nonidentical sample populations.10.8 Repeatability and reproducibility expressed as a per-centage of the mean level (r) and (R) have equivalent applica-tion statements as 10.6 and 10.7 for r and R. For the (r) and (R)statements t

36、he difference in the two single test results isexpressed as a percentage of the arithmetic mean of the two testresults.10.9 BiasIn test method terminology, bias is the differencebetween an average test value and the reference (or true) testproperty value. Reference values do not exist for this testm

37、ethod since the value (of the test property) is exclusivelydefined by the test method. Bias, therefore, cannot be deter-mined.11. Keywords11.1 HNBR; iodine value; residual unsaturationASTM International takes no position respecting the validity of any patent rights asserted in connection with any it

38、em mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical com

39、mittee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a

40、meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Driv

41、e, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.or

42、g). Permission rights to photocopy the standard may also be secured from the Copyright Clearance Center, 222Rosewood Drive, Danvers, MA 01923, Tel: (978) 646-2600; http:/ 1 Type 1 PrecisionResidual Unsaturation of HNBR by Iodine ValueHNBRNominalContentACN,%Mean(cgI2/g)Within LaboratoryABetween Labor

43、atoryASrr (r) SRR (R)#1 33 6.39 0.282 0.800 12.50 0.324 0.916 14.30#2 36 12.57 0.181 0.512 4.07 0.344 0.973 7.74#3 36 28.75 0.262 0.741 2.58 0.496 1.400 4.87ASymbols are defined as follows:Sr= within-laboratory standard deviation,r = repeatability, measurement units,(r) = repeatability, %SR= between-laboratory standard deviation,R = reproducibility, measurement units, and(R) = reproducibility,% .D5902 05 (2015)3