ASTM D6407-1999(2014) 7492 Standard Test Method for Analysis of Iron and Copper in Vegetable Tanning Materials《分析植物单宁材料中铁和铜的标准试验方法》.pdf

上传人:towelfact221 文档编号:522430 上传时间:2018-12-03 格式:PDF 页数:4 大小:72.68KB
下载 相关 举报
ASTM D6407-1999(2014) 7492 Standard Test Method for Analysis of Iron and Copper in Vegetable Tanning Materials《分析植物单宁材料中铁和铜的标准试验方法》.pdf_第1页
第1页 / 共4页
ASTM D6407-1999(2014) 7492 Standard Test Method for Analysis of Iron and Copper in Vegetable Tanning Materials《分析植物单宁材料中铁和铜的标准试验方法》.pdf_第2页
第2页 / 共4页
ASTM D6407-1999(2014) 7492 Standard Test Method for Analysis of Iron and Copper in Vegetable Tanning Materials《分析植物单宁材料中铁和铜的标准试验方法》.pdf_第3页
第3页 / 共4页
ASTM D6407-1999(2014) 7492 Standard Test Method for Analysis of Iron and Copper in Vegetable Tanning Materials《分析植物单宁材料中铁和铜的标准试验方法》.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: D6407 99 (Reapproved 2014)Standard Test Method forAnalysis of Iron and Copper in Vegetable Tanning Materials1This standard is issued under the fixed designation D6407; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, th

2、e year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is intended for use in determining ironand copper content in vegetable tanning materials. T

3、his testmethod is applicable to liquid, solid, pasty and powderedextracts, to raw and spent materials, and to tannery liquors.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all

4、of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D4901 Practice for Pre

5、paration of Solution of Liquid Veg-etable Tannin ExtractsD4902 Test Method for Evaporation and Drying of Analyti-cal SolutionsD6404 Practice for Sampling Vegetable Materials Contain-ing TanninD6405 Practice for Extraction of Tannins from Raw andSpent Materials2.2 ALCA Methods:A31 Method for Copper a

6、nd Iron in Tanning Materials33. Summary of Test Method3.1 A specified quantity of the tanning material is analyzedfor iron and copper and content.4. Significance and Use4.1 This test method is used to determine the quantity ofiron and copper present in vegetable tanning materials orvegetable tannin

7、extracts prepared using Practices D4901,D6404,orD6405.4.2 Because of the possibility of errors in this test method itis essential that the method be followed exactly in order toobtain reproducible results both among specimens within alaboratory and for analyses between laboratories.5. Apparatus and

8、Reagents5.1 Sulfuric Acid, concentrated (96 %).5.2 Sulfuric Acid Solution, diluted 1:20 with distilled water.5.3 Nitric Acid, fuming.5.4 Hydrochloric Acid, concentrated (36 %).5.5 Hydrochloric Acid Solution, 0.1 N.5.6 Bromine Water, saturated solution.5.7 Ammonium Hydroxide Solution, concentrated di

9、luted1:1 with distilled water.5.8 Potassium Permanganate Solution, 0.1 N.5.9 Potassium (or Ammonium) Thiocyanate Solution, 10 gshall be dissolved in distilled water and diluted to 100 mL withdistilled water.5.10 Stock Iron Solution, This may be a purchased ironstandard solution or may be prepared as

10、 follows:5.10.1 0.70 g of crystallized ferrous ammonium sulfateFeSO4(NH4)2SO46H2O shall be dissolved in 50 mL ofdistilled water and 20 mL of dilute sulfuric acid (diluted 1:4).5.10.2 This solution shall be titrated with 0.1 N potassiumpermanganate solution until a faint pink persists for 1 minuteand

11、 the iron is completely oxidized.5.10.3 Dilute this solution to 1 L with distilled water. 1 mLof this solution is equivalent to 0.0001 g Fe. This solution shallbe stored in brown bottles and be protected from light.5.10.4 Standard Iron Solution, 10 mL of the prepared stocksolution, or its equivalent

12、 of purchased iron standard solution,shall be diluted to 100 mL with distilled water. 1 mL of thisstandard solution is equivalent to 0.00001 g Fe. The standardsolution shall be freshly prepared for each analysis.1This test method is under the jurisdiction of ASTM Committee D31 on Leatherand is the d

13、irect responsibility of Subcommittee D31.01 on Vegetable Leather. Thistest method has been adapted from and is a replacement for Method A31 of theOfficial Methods of the American Leather Chemists Association.Current edition approved Nov. 1, 2014. Published December 2014. Originallyapproved in 1999.

14、Last previous edition approved in 2009 as D6407 99 (2009).DOI: 10.1520/D6407-99R14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary pa

15、ge onthe ASTM website.3Official Methods of the American Leather Chemists Association. Availablefrom the American Leather Chemists Association, University of Cincinnati, P.O.Box 210014, Cincinnati, OH 45221-0014.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 1

16、9428-2959. United States15.11 Stock Copper Solution, 3.9283 g of copper sulfatecrystals (CuSO45H2O) shall be dissolved in distilled waterand diluted to 1 L with distilled water. 1 mL of this solution isequivalent to 0.001 g Cu.5.11.1 Standard Copper Solution, 10 mL of the stock coppersolution shall

17、be diluted to 1 L with distilled water and the pHadjusted to between 5.5 and 6.0. 1 mL of this standard solutionis equivalent to 0.00001 g Cu. The standard solution shall befreshly prepared for each analysis.5.12 Xanthate Solution, 1.0 g of potassium ethyl xanthateshall be dissolved in distilled wat

18、er and diluted to 1 L withdistilled water. The solution shall be freshly prepared for eachanalysis.5.13 Matched Nessler Tubes and Supporting Rack.5.14 Balance, analytical balance which will weigh up to 100g with an accuracy of 6 0.1 mg (6 0.0001 g).5.15 Drying Oven, a forced-air convection oven (orm

19、echanical-convection draft oven) capable of maintaining atemperature of 100 6 2.0C.5.16 Thermometer, accurate to 6 0.2C used to check andmonitor the oven set point.5.17 Dessicator, any convenient form or size, using anynormal desiccant.5.18 Glazed, Porcelain Dish or Crucible of Suitable Size.5.19 Mu

20、ffle Furnace, capable of maintaining a temperatureof 600 6 25C.5.20 Hotplate, ordinary lab grade.5.21 Steam Bath, ordinary lab grade.5.22 Volumetric Flasks, 200 and 250 mL capacity.5.23 Beakers, 250 mL.5.24 Filter Paper, quantitative, Whatman grade 40 or 52 orsimilar.5.25 Buret, 10 mL capacity is su

21、fficient.6. Test Specimen6.1 The sample of material from which the test specimensare taken shall be prepared as described in Practice D6404 forextracts and tannery liquor and as in the Preparation of Samplesection of Practice D6405 for raw and spent materials.6.2 The specimen shall consist of5gofsol

22、id extract or itsequivalent (that is 10 g of liquid extract; 25 to 50 g of tanneryliquor;5gofraworspent materials).7. General Instructions7.1 The distilled water shall be distilled from a glass,tin-lined, or block tin still and shall be stored in glass, tin-lined,or block tin containers.7.2 All appa

23、ratus used in this analysis shall be cleaned withhot hydrochloric acid solution (diluted 1 to 1) and rinsed withdistilled water before use.7.3 Blank determinations shall be made to minimize errorsdue to iron or copper either present in the reagents used orpicked up during the analysis.7.4 Duplicate

24、determinations are recommended wheneverpossible.7.5 In the actual colorimetric determinations describedbelow, the indicated volumes of reagents, and of the preparedsolutions of the specimens and of standards, are based on theuse 50 mL tall-form Nessler tubes. Other tube volumes andforms may be used,

25、 provided: they be used in matched sets andthe volumes of reagents, specimen and standard solutions beadjusted so that similar color intensities are produced. Suchadjustments are automatic with, and familiar to, the experi-enced analyst and are not precluded by the method. If,however, the analyst is

26、 in doubt as to the proper adjustment tobe made, it is recommended that 50 mL tall-form tubes be usedexactly as described.7.6 Comparison of the colors developed in the Nessler tubesshall be made under a source of daylight from the north, thetubes being held vertically two inches above an inclined sh

27、eetof white paper, and viewed downward through the full depth ofliquid.8. Procedure8.1 Transfer the specimen to a tared, glazed, porcelain dishor crucible of suitable size, taking care to avoid changes inmoisture content, and weigh to the nearest 0.1 mg (0.0001 g).Where necessary, place the dish and

28、 specimen in the oven andevaporate to dryness (Test Method D4902).8.2 Ignite the dish containing the dried residue gently overa low flame, at as low a temperature as possible, until theresidue is thoroughly charred and all smoke driven off. Thenplace the dish and charred residue in a muffle furnace

29、and ash,at a temperature not exceeding 600C, until all carbon has beenremoved.NOTE 1Occasionally, the specimen will be of such a nature that all thecarbon cannot be removed as described above. In such a case, saturate thecharred mass with hot distilled water and break it up as completely aspossible

30、with a glass rod. Then add more of the hot distilled water anddigest the whole on the steam bath for a few minutes. Decant thesupernatant through a quantitative filter paper, collect the filtrate in asuitable receiver. Digest the charred residue twice more with hot distilledwater, decant the superna

31、tant through the same filter each time, andcombine the filtrates. Finally transfer the char to the filter and wash severaltimes with hot distilled water, the washings being combined with thefiltrates. Then replace the filter and residue in the original dish, dry, andash the whole, as before, until a

32、ll the carbon has been removed. Cool thedish, quantitatively transfer the combined filtrates and washings theretoand evaporate and dry. Then place the dish and contents in a cold mufflefurnace, raise the temperature, slowly at first to avoid loss by spurting, andfinally bring to a value not exceedin

33、g 600C.8.3 Cool the carbon-free ash, moisten with hot distilledwater, 5 mL of concentrated hydrochloric acid added, and heatthe mixture on the steam bath until the ash is dissolved. Addthe five drops of fuming nitric acid and five drops of brominewater and heat the mixture on the steam bath, gently

34、at firstuntil evolution of gas ceases (use fume cupboard or hood), andfinally evaporate to dryness. Then moisten the residue withdistilled water, 5 mL of concentrated hydrochloric acid added,the mixture digested on the steam bath for a few minutes andfinally transfer, quantitatively, into a 250 mL b

35、eaker.Adjust thevolume to about 75 mL by boiling if necessary. Then make theD6407 99 (2014)2solution faintly ammoniacal with ammonium hydroxide solu-tion (diluted 1 to 1) and boil gently to remove excess ammoniaand to coagulate the precipitated iron and aluminum hydrox-ides.8.4 Then allow the mixtur

36、e to stand on the hotplate, for afew minutes, until the precipitate has settled. As soon aspossible thereafter, decant the hot supernatant through asuitable filter paper except when copper is to be determined, inwhich case use an asbestos-gooch filter (previously washedwith hot, 1:1 hydrochloric aci

37、d, distilled water, 1:1 ammoniumhydroxide, and distilled water) (ammoniacal copper solutionscombine with cellulose). Wash the precipitate three times, bydecantation, with hot, faintly ammoniacal, distilled water (fivedrops 1:1 ammonium hydroxide solution per liter of distilledwater). Finally, quanti

38、tatively transfer the precipitate to thefilter and wash four times with the hot, faintly ammoniacaldistilled water. Reserve the residue on the filter for thedetermination of iron (8.5), and the combined filtrate andwashings reserved for determination of copper (8.6).8.5 Determination of Iron:8.5.1 D

39、issolve the residue on the filter by running onto ittwo portions of 1:20 sulfuric acid solution, of 20 mL each,collecting the solution in a suitable receiver. Then thoroughlywash the filter, four times, with 1:20 sulfuric acid solution, thewashings being added to the first 40 mL. Quantitativelytrans

40、fer the combined acid solution and washings to a suitablevolumetric flask (usually 200 mL is adequate), cool ifnecessary, and bring to the mark with 1:20 sulfuric acidsolution. Make a quantitative test of this solution as a guide tothe proper size of aliquot required in the quantitative determi-nati

41、on below.8.5.2 Add to the known aliquot of the above solution in aNessler tube, sufficient 1:20 sulfuric acid solution to bring to avolume of 35 mL, two drops of 0.1 N potassium permanganatesolution, and mix the contents of the tube and then allow tostand for 5 min, add more permanganate solution, i

42、f necessary,until a slight pink persists. (Where several specimens are beingexamined, prepare all the specimen tubes, as above, at the sametime.)8.5.3 Prepare a series of standard Nessler tubes similarly,containing 0.5 to 1.5 mL of standard iron solution in incre-ments of 0.1 or 0.2 mL, add the iron

43、 solution from a buret. Mixthe contents of the tubes and then allow to stand for 5 min, addmore permanganate solution, if necessary, until a slight pinkpersists.8.5.4 If the color of the specimen tube be outside the rangeof the standards, repeat the comparison with fresh standardsand an aliquot of m

44、ore suitable size from the solution preparedin 8.5.1.8.6 Determination of Copper:8.6.1 Adjust the pH of the combined ammoniacal filtrateand washings from 8.4 to between 5.5 and 6.0 by carefuladdition of 1.0 N hydrochloric acid. Then quantitativelytransfer the pH adjusted solution to a suitable volum

45、etric flask(250 mL is usually adequate), cool if necessary, and bring tovolume with distilled water.8.6.2 Prepare a series of standard Nessler tubes containing 0to 4 mL of standard copper solution in 0.5 mL increments, addthe copper solution from a buret. To each standard tube, add 10mL xanthate sol

46、ution and sufficient distilled water to bring tovolume. Then thoroughly mix the contents of the tubes byinverting several times.8.6.3 Add to another Nessler tube a known aliquot of thesolution prepared as in 8.6.1, followed by 10 mL of xanthatesolution and sufficient distilled water to bring to volu

47、me.Thoroughly mix the contents of the tube by inverting severaltimes, and compare the color with that of the standards. Makethe comparison within 15 min of the addition of xanthate to thespecimen and standard tubes. Record the volume of standardcopper solution in that standard whose color most close

48、lymatches that of the specimen tube. (With care, the color can beestimated to the equivalent of 0.25 mL of standard coppersolution.)8.6.4 If the color of the specimen tube be deeper than that ofthe 4.0 mL standard, repeat the comparison using a lesseraliquot.9. Results9.1 Iron:9.1.1 Calculate iron c

49、ontent as follows:iron %! 5 M 2 B! 3V#/1000 3Q 3W# (1)where:M = mL of standard iron solution in the matching standard,B = mL of standard iron solution matching the Q mL of theblank,V = capacity of the volumetric flask used in 8.5.1 (usually200 mL),Q = aliquot (mL) taken in 8.5.2, andW = g of specimen taken in 8.1.9.1.2 Instead of the visual color comparison, the use of astandard photometer shall be permissible, provided the calibra-tion curve be established on standards made up following theprocedures in 8.5.2 and 8.5.3. (It is advisable to recheck thecalibration cur