ASTM D6902-2004(2011) 3750 Standard Test Method for Laboratory Measurement of Formaldehyde Evolved During the Curing of Melamine-Formaldehyde-Based Coatings《实验室测量三聚氰胺-甲醛基涂料的固化期间放出的.pdf

上传人:testyield361 文档编号:523928 上传时间:2018-12-04 格式:PDF 页数:7 大小:156.36KB
下载 相关 举报
ASTM D6902-2004(2011) 3750 Standard Test Method for Laboratory Measurement of Formaldehyde Evolved During the Curing of Melamine-Formaldehyde-Based Coatings《实验室测量三聚氰胺-甲醛基涂料的固化期间放出的.pdf_第1页
第1页 / 共7页
ASTM D6902-2004(2011) 3750 Standard Test Method for Laboratory Measurement of Formaldehyde Evolved During the Curing of Melamine-Formaldehyde-Based Coatings《实验室测量三聚氰胺-甲醛基涂料的固化期间放出的.pdf_第2页
第2页 / 共7页
ASTM D6902-2004(2011) 3750 Standard Test Method for Laboratory Measurement of Formaldehyde Evolved During the Curing of Melamine-Formaldehyde-Based Coatings《实验室测量三聚氰胺-甲醛基涂料的固化期间放出的.pdf_第3页
第3页 / 共7页
ASTM D6902-2004(2011) 3750 Standard Test Method for Laboratory Measurement of Formaldehyde Evolved During the Curing of Melamine-Formaldehyde-Based Coatings《实验室测量三聚氰胺-甲醛基涂料的固化期间放出的.pdf_第4页
第4页 / 共7页
ASTM D6902-2004(2011) 3750 Standard Test Method for Laboratory Measurement of Formaldehyde Evolved During the Curing of Melamine-Formaldehyde-Based Coatings《实验室测量三聚氰胺-甲醛基涂料的固化期间放出的.pdf_第5页
第5页 / 共7页
亲,该文档总共7页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: D6902 04 (Reapproved 2011)Standard Test Method forLaboratory Measurement of Formaldehyde Evolved Duringthe Curing of Melamine-Formaldehyde-Based Coatings1This standard is issued under the fixed designation D6902; the number immediately following the designation indicates the year oforig

2、inal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is for the determination of formalde-hyde evol

3、ved from melamine-formaldehyde-based coatingsduring the cure step. The results may be used to determine the“cure formaldehyde” evolved from a sample under controlledlaboratory conditions.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for info

4、rmationonly.1.3 This test method is capable of measuring from 500 g/gto 22 000 g formaldehyde/g dry coating under the testconditions specified (3 000 ml/min total flow, 50 ml/minDNPH tube flow). The ratio of total flow to DNPH tube flowcould be adjusted to extend the range of the method.1.4 This sta

5、ndard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1

6、ASTM Standards:2D362 Specification for Industrial Grade Toluene3D1979 Test Method for Free Formaldehyde Content ofAmino Resins3D6191 Test Method for Measurement of Evolved Formal-dehyde from Water Reducible Air-Dry CoatingsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precisi

7、on of a Test Method3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 cure formaldehyde, nthe formaldehyde generated asthe result of a chemical reaction during coating curing.3.1.2 free formaldehyde, nthe residual formaldehyde in acoating due to the raw materials.4. Summary of Te

8、st Method4.1 Approximately 0.2 g of coating formulation is placed inan aluminum foil pan, dried in a vacuum oven at 40C (toremove free formaldehyde and solvents) and then baked at theoptimum process cure temperature for 30 min. Formaldehydeemissions are collected from the cure chamber on a DNPH/Sili

9、ca tube, which is then extracted and the extract analyzed byHPLC/UV. The amount of formaldehyde evolved from thecoating during the cure step is calculated on both a wet-weightand dry-weight basis. The test is run in triplicate plus a blankand system standard.5. Significance and Use5.1 This test meth

10、od measures the amount of formaldehydethat is evolved from a coating containing melamine-formaldehyde resin(s) during cure at elevated temperature.Cure formaldehyde results from a side-reaction during cross-linking of functionalized polymers with melamine-formaldehyde resins. Cure formaldehyde is ev

11、olved in the finalbake or cure oven, when the coating temperature is highenough to initiate cross-linking. Formaldehyde can be releasedfrom a coating during application, solvent flash-off and cure.Free formaldehyde is primarily evolved during coating appli-cation and solvent flash-off. Test Method D

12、1979 measures“free formaldehyde” in amino resins and Test Method D6191measures formaldehyde evolved from coatings at ambienttemperature. This method measures only the formaldehydereleased during heat cure, which is primarily “cure formalde-hyde.”1This test method is under the jurisdiction of ASTM Co

13、mmittee D01 on Paintand Related Coatings, Materials, and Applications and is the direct responsibility ofSubcommittee D01.21 on Chemical Analysis of Paints and Paint Materials.Current edition approved June 1, 2011. Published June 2011. Originallyapproved in 2003. Last previous edition approved in 20

14、04 as D6902 041. DOI:10.1520/D6902-04R11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last

15、 approved version of this historical standard is referencedon www.astm.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.2 This test method is not intended to duplicate the evolvedformaldehyde from an industrial process, but serv

16、es as areproducible comparative laboratory evaluation.5.3 This test method has not been evaluated with catalyzedcoating systems that cure at or below 40C, such as those usedby the wood-finishing industry, and would likely requirespecial adaptation for this application.6. Apparatus6.1 High Pressure L

17、iquid Chromatograph (HPLC), either agradient or isocratic system. A gradient system is preferredwhen other aldehydes or ketones are present.NOTE 1The system shall be equipped with a temperature-controlledcolumn oven. A liquid autosampler is optional.6.2 Column,aC18ODS packed with 5-m pellicular bead

18、swith the dimensions of approximately 4 mm by 75 or 150 mm.A 2-cm guard column packed with the same material isrecommended to protect the analytical column.6.3 Detector, UV/VIS detector capable of measuring absor-bance at 360 nm.6.4 Integrator, peak integration system.6.5 Air Sampling Pump, an air s

19、ampling pump with thecapability of maintaining a constant flow rate between 3 and 4L/min. Both an inlet and outlet port must be available formeasuring flow. An SKC AirCheck Sampler Model 224-PCXR8 has been found suitable.6.6 Flow MetersAn in-line mass flow meter or flowsensor capable of measuring 30

20、 to 120 mL/min with at least3 % accuracy. A flow meter or bubble meter capable ofmeasuring 3 to 4 L/min with at least 5 % accuracy.6.7 Glass Purge ChamberA glass purge chamber with amouth at least 60 mm wide and a lid with an air-tight gasketseal. One liter reaction flask, reaction flask head with t

21、wothreads, two 5029 tetrafluorethylene polymer bushings andFETFE O-Ring and 124 mm anodized 2 piece clamp, AceGlass part numbers 6511-53, 6513-SP, and 6508-6.6.8 Valves Two metering valves to adjust split flow rate.One valve must be constructed of stainless steel. A Swagelok506-1-316 has been found

22、suitable.6.9 Aluminum Foil Dishes, 58 mm in diameter by 18 mmhigh with a smooth (planar) bottom surface.6.10 Forced Draft Oven, oven, capable of maintaining160C (320F), of adequate size to accommodate one or morepurge chambers.6.11 Vacuum Oven, capable of maintaining 40C and avacuum of 0.1 to 0.2 Ba

23、rr (100 mm Hg).6.12 Volumetric Glassware, various volumetric flasks andpipettes for preparation of calibration standards. Also, 5-mLvolumetric flasks for sample elution.6.13 Analytical BalanceFour-place analytical balance ca-pable of measuring to 60.1mg (0.0001 g).6.14 Sherer Impinger Diffuser, A 25

24、 mm dia, 275 mL withimpinger stopper, Ace Glass part number 7538-29 has beenfound suitable.6.15 Water Trap, 1000 mL vacuum flask with stopper.6.16 Thermometer, thermocouple with temperature readoutcalibrated in range of 50F to 400F.7. Reagents and Materials7.1 Purity of ReagentsUse reagent grade che

25、micals in alltests, unless otherwise specified. Other grades may be used,provided it is first ascertained that the reagent is sufficientlyhigh purity to permit its use without lessening the accuracy ofthe determination.7.2 Toluene, technical grade, Specification D362.7.3 Tetrahydrofuran, HPLC Grade.

26、7.4 Water, HPLC Grade.7.5 Acetonitrile, HPLC Grade.7.6 DNPH-Silica Cartridge, Waters Sep-Pak Cartridges,Part # WAT037500.7.7 Formaldehyde/2,4-dinitrophenylhydrazone (DNPH)Complex, may be purchased or prepared in the laboratory.7.8 Calcium Nitrate Tetrahydrate, reagent grade.7.9 Paraformaldehyde, rea

27、gent grade.8. Hazards8.1 Check the suppliers Material Safety Data Sheet(MSDS) on all chemicals before use.9. Preparation of Apparatus9.1 Install the column in the chromatograph following themanufacturers directions and establish the operating condi-tions required to give the desired separation (see

28、Table 1).Allow sufficient time for the instrument to reach equilibrium asindicated by a stable baseline.9.2 Purge Chamber Set Up:9.2.1 Assemble apparatus (empty purge chamber, impinger,pump, flow meters and valving) as shown in Fig. 1 with aDNPH cartridge in line (use two DNPH cartridges for water-b

29、orne coatings and paraformaldehyde calibration check).9.2.2 Add 500 g of calcium nitrate tetrahydrate to 250 mLofreagent grade water to form a near saturated solution. Place thismixture in the constant humidity Insert the Sherer Impinger sothat the solution is 8 in. above the bottom of the impinger

30、tip.Mark the solution level on the impinger.NOTE 2This calcium nitrate tetrahydrate solution ensures a constanthumidity of 55 %.Add water when the solution level falls below the mark.9.2.3 Adjust the forced draft oven so that the pan tempera-ture is set at the coating manufacturers recommended optim

31、umprocess cure temperature 62F (usually with the range of 260TABLE 1 Instrument ConditionsDetector UV/VIS Absorbance 360 nmColumn (Isocratic) C18ODS4by75mmMobile Phase (Isocratic) Water/Acetonitrile/Tetrahydrofuran65/30/5 volume/volumeColumn (Gradient) C18ODS 4 by 150 mmMobile Phase (Gradient) Water

32、/Acetonitrile/TetrahydrofuranA: 65/30/10 volume/volumeB: 40/60/0 volume/volume100%Afor1minthenlinear gradientto100%Bin10minFlow Rate 1.5 mL/minColumn Temperature 40CRun Time (Isocratic) 10 minRun Time (Gradient) 15 minInjection Volume 10 to 20 LD6902 04 (2011)2to 310F for automotive coatings). Use a

33、 thermocouple tapedto the bottom of the pan to measure pan temperature.9.2.4 Adjust pump flow rate to 3.0 to 3.5 L/min.9.2.5 Adjust valves A and B until the DNPH Cartridge hasa flow of 50 mL/min.9.2.6 Check pump flow rate to ensure it is still in the properrange. Recommended starting flows; Pump 3.0

34、 L/min, DNPHCartridge 50 mL/min (1:60 split).10. Calibration10.1 Use the information in Table 1 as a guide to select theconditions that give the necessary resolution of formaldehyde-DNPH derivative from interferences in the samples.10.2 Determination of Relative Response FactorsThe re-sponse factor

35、relative to the standard is determined by means ofthe following procedure. It is good practice to determine therelative retention time daily or with each series of determina-tions.10.2.1 Prepare a minimum four-point standard curve ofFormaldehyde-DNPH derivative in acetonitrile, ranging from0.1 to 10

36、 g/mL as formaldehyde. Recommended curve 0.1,1.0, 5.0 and 10 g/mL.10.2.2 Inject a 10 to 20 L aliquot of the standard mixtureinto the HPLC. At the end of the chromatographic run,calibrate the integrator by following the manufacturers proce-dure for external standard calibration. If this capability is

37、 notavailable, refer to the following calculations. See Figs. 2 and 3for typical chromatograms using the three listed columns.FIG. 1 Page Chamber Set-UpD6902 04 (2011)310.2.3 The response factor of each analyte is calculated asfollows:Ranalyte5AanalyteCanalyte(1)where:Ranalyte= response factor for t

38、he analyte being calibrated,Canalyte= concentration of formaldehyde in mg/mL, andAanalyte= peak area for the analyte being calibrated.10.2.4 Calculate the average response factor for all concen-trations and the correlation coefficient for calibration curve. Ifthe correlation coefficient is not 0.999

39、9 or greater, repeatcalibration process.10.3 System Integrity:FIG. 2 Isocratic Separation of C1-C3Aldehyde and Ketone DerivativesFIG. 3 Gradient Separation of C1-C9Aldehyde and Ketone DerivativesD6902 04 (2011)410.3.1 System BlankFollow procedure (Section 11) belowonly using a blank aluminum foil di

40、sh. Result should be belowdetection for formaldehyde.10.3.2 System StandardFollow procedure beginning at10.2, using two DNPH cartridges and an oven temperature of150C.Add 4.0 6 0.5 mg of paraformaldehyde to a cool emptypan and record weight to nearest 0.1 mg. Total formaldehydemeasured should be equ

41、al to the amount of paraformaldehydeused 65 %, with less than a 1 % breakthrough to the secondcartridge. Analyze system standard on a minimum daily basis.11. Procedure11.1 Prepare Coating Specimens:11.1.1 Mix the coating sample, preferably on a mechanicalshaker or roller for solventborne and by hand

42、 for waterbornecoatings, until homogeneous. If air bubbles become entrapped,stir by hand until air has been removed.11.1.2 Rinse aluminum foil dishes (6.9) with toluene, wipedry with a lint-free cloth then bake at cure temperature andtime. Place dishes in a desiccator to cool after baking.11.1.3 Rec

43、ord the weight of three dry aluminum foil dishes.11.1.4 Measure 0.2 6 0.05 g of coating formulation into atared aluminum foil dish using a syringe by measuring theweight of the syringe before and after dispensing the coating.Record weight of the dispensed coating on Bench Data Sheet(Fig. 4).FIG. 4 B

44、ench Data SheetD6902 04 (2011)511.1.4.1 For solventborne coatings add 1.5 mL of toluene todisperse the coating evenly on the bottom of the dish.11.1.4.2 For waterborne coatings add one mL of distilledwater, swirling pan until the coating formulation is fullywetted. Add one mL of ethanol again swirli

45、ng the pan until thecoating is fully dispersed.11.1.5 Place dish immediately into a level vacuum oven setat 40C.11.1.6 Repeat steps 11.1.3-11.1.5 two more times. Thenevacuate the oven to 0.1 to 0.2 Barr (100 mm Hg).11.1.7 Allow specimens to dry in vacuum oven for1hat40C.11.1.8 Remove the dishes from

46、 the vacuum oven and placein a covered container at room temperature. Specimens shouldnot stand for more than 72 h between solvent evaporation andcuring.NOTE 3For applications where a clearcoat is applied on top of abasecoat, it is recommended that the procedure be followed through step11.1.8 for th

47、e basecoat then return to step 11.1.4 and apply the clearcoat.11.2 Cure Coating Specimens:11.2.1 Assemble apparatus as described in 9.2 with a freshDNPH Cartridge (two cartridges for waterborne coatings).11.2.2 Place one dish containing specimen in a cool (roomtemp) purge chamber.11.2.3 Replace hot

48、empty purge chamber (using insulatedgloves) with chamber containing specimen, attaching the coveras quickly as possible.11.2.4 Record initial flows (Total Flow and Tube Flow) andstart time on Bench Data Sheet.11.2.5 Allow coating to cure for 30 min then record finalflows (Total Flow and Tube Flow) a

49、nd end time on Bench DataSheet.11.2.6 Disconnect, cap and label the DNPH Cartridge(s).11.2.7 Remove purge chamber from oven (using insulatedgloves), remove aluminum foil dish from purge chamber withtongs and place into a desiccator to cool.11.2.8 Repeat steps 11.2.1-11.2.7 for other two replicatesand one blank run with empty foil dish.NOTE 4An alternative to running a purge chamber blank would be toattach a DNPH cartridge at the inlet to the purge chamber (outside of theoven) and analyze this cartridge every 20 runs to demonstrate thatfor

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1