ASTM D7343-2018 3750 Standard Practice for Optimization Sample Handling Calibration and Validation of X-ray Fluorescence Spectrometry Methods for Elemental Analysis of Petroleum Pr.pdf

上传人:feelhesitate105 文档编号:525221 上传时间:2018-12-04 格式:PDF 页数:7 大小:111.09KB
下载 相关 举报
ASTM D7343-2018 3750 Standard Practice for Optimization Sample Handling Calibration and Validation of X-ray Fluorescence Spectrometry Methods for Elemental Analysis of Petroleum Pr.pdf_第1页
第1页 / 共7页
ASTM D7343-2018 3750 Standard Practice for Optimization Sample Handling Calibration and Validation of X-ray Fluorescence Spectrometry Methods for Elemental Analysis of Petroleum Pr.pdf_第2页
第2页 / 共7页
ASTM D7343-2018 3750 Standard Practice for Optimization Sample Handling Calibration and Validation of X-ray Fluorescence Spectrometry Methods for Elemental Analysis of Petroleum Pr.pdf_第3页
第3页 / 共7页
ASTM D7343-2018 3750 Standard Practice for Optimization Sample Handling Calibration and Validation of X-ray Fluorescence Spectrometry Methods for Elemental Analysis of Petroleum Pr.pdf_第4页
第4页 / 共7页
ASTM D7343-2018 3750 Standard Practice for Optimization Sample Handling Calibration and Validation of X-ray Fluorescence Spectrometry Methods for Elemental Analysis of Petroleum Pr.pdf_第5页
第5页 / 共7页
亲,该文档总共7页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: D7343 18Designation: 558/07Standard Practice forOptimization, Sample Handling, Calibration, and Validationof X-ray Fluorescence Spectrometry Methods for ElementalAnalysis of Petroleum Products and Lubricants1This standard is issued under the fixed designation D7343; the number immediate

2、ly following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This pra

3、ctice covers information relating to sampling,calibration and validation of X-ray fluorescence instrumentsfor elemental analysis, including all kinds of wavelengthdispersive (WDXRF) and energy dispersive (EDXRF) tech-niques. This practice includes sampling issues such as theselection of storage vess

4、els, transportation, and sub-sampling.Treatment, assembly, and handling of technique-specificsample holders and cups are also included. Technique-specificrequirements during analytical measurement and validation ofmeasurement for the determination of trace elements insamples of petroleum and petrole

5、um products are described.For sample mixing, refer to Practice D5854. Petroleum prod-ucts covered in this practice are considered to be a single phaseand exhibit Newtonian characteristics at the point of sampling.1.2 Applicable Test MethodsThis practice is applicable tothe XRF methods under the juri

6、sdiction of ASTM Subcommit-tee D02.03 on Elemental Analysis, and those under thejurisdiction of the Energy Institutes Test Method Standardiza-tion Committee (Table 1). Some of these methods are techni-cally equivalent though they may differ in details (Table 2).1.3 Applicable FluidsThis practice is

7、applicable to petro-leum and petroleum products with vapor pressures at samplingand storage temperatures less than or equal to 101 kPa(14.7 psi). Use Practice D4057 or IP 475 to sample thesematerials. Refer to Practice D5842 when sampling materialsthat also require Reid vapor pressure (RVP) determin

8、ation.1.4 Non-applicable FluidsPetroleum products whose va-por pressure at sampling and sample storage conditions areabove 101 kPa (14.7 psi) and liquefied gases (that is, LNG,LPG, etc.) are not covered by this practice.1.5 Sampling MethodsThe physical sampling and meth-ods of sampling from a primar

9、y source are not covered by thisguide. It is assumed that samples covered by this practice area representative sample of the primary source liquid. Refer toPractice D4057 or IP 475 for detailed sampling procedures.1.6 The values stated in SI units are to be regarded asstandard. The values given in p

10、arentheses after SI units areprovided for information only and are not considered standard.1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and envi

11、ronmental practices and deter-mine the applicability of regulatory limitations prior to use.1This practice is under the jurisdiction of ASTM Committee D02 on PetroleumProducts, Liquid Fuels, and Lubricants and is the direct responsibility of Subcom-mittee D02.03 on Elemental Analysis.Current edition

12、 approved June 1, 2018. Published June 2018. Originallyapproved in 2007. Last previous edition approved in 2017 as D7343 12 (2017).DOI: 10.1520/D7343-18.This practice was jointly prepared by ASTM International and the EnergyInstitute.*A Summary of Changes section appears at the end of this standardC

13、opyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of Intern

14、ational Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.11.8 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for

15、theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D2622 Test Method for Sulfur in Petroleum Products byWavelength Dispersive X-ray Fluorescence Spectromet

16、ryD4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD4294 Test Method for Sulfur in Petroleum and PetroleumProducts by Energy Dispersive X-ray Fluorescence Spec-trometryD4927 Test Methods for Elemental Analysis of Lubricantand Additive ComponentsBarium, Calcium,Phosphorus, Sulfur,

17、 and Zinc by Wavelength-DispersiveX-Ray Fluorescence SpectroscopyD4929 Test Method for Determination of Organic ChlorideContent in Crude OilD5059 Test Methods for Lead in Gasoline by X-Ray Spec-troscopyD5842 Practice for Sampling and Handling of Fuels forVolatility MeasurementD5854 Practice for Mixi

18、ng and Handling of Liquid Samplesof Petroleum and Petroleum ProductsD6299 Practice for Applying Statistical Quality Assuranceand Control Charting Techniques to Evaluate AnalyticalMeasurement System PerformanceD6334 Test Method for Sulfur in Gasoline by WavelengthDispersive X-Ray FluorescenceD6443 Te

19、st Method for Determination of Calcium, Chlorine,Copper, Magnesium, Phosphorus, Sulfur, and Zinc inUnused Lubricating Oils and Additives by WavelengthDispersive X-ray Fluorescence Spectrometry (Mathemati-cal Correction Procedure)D6445 Test Method for Sulfur in Gasoline by Energy-Dispersive X-ray Flu

20、orescence Spectrometry (Withdrawn2009)3D6481 Test Method for Determination of Phosphorus,Sulfur, Calcium, and Zinc in Lubrication Oils by EnergyDispersive X-ray Fluorescence SpectroscopyD7039 Test Method for Sulfur in Gasoline, Diesel Fuel, JetFuel, Kerosine, Biodiesel, Biodiesel Blends, andGasoline

21、-Ethanol Blends by Monochromatic WavelengthDispersive X-ray Fluorescence SpectrometryD7212 Test Method for Low Sulfur in Automotive Fuels byEnergy-Dispersive X-ray Fluorescence Spectrometry Us-ing a Low-Background Proportional CounterD7220 Test Method for Sulfur in Automotive, Heating, andJet Fuels

22、by Monochromatic Energy Dispersive X-rayFluorescence SpectrometryD7751 Test Method for Determination of Additive Elementsin Lubricating Oils by EDXRF AnalysisD7757 Test Method for Silicon in Gasoline and RelatedProducts by Monochromatic Wavelength DispersiveX-ray Fluorescence SpectrometryD8127 Test

23、Method for Coupled Particulate and ElementalAnalysis using X-ray Fluorescence (XRF) for In-ServiceLubricants2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the stan

24、dards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.TABLE 1 XRF Standard Test Methods for Analysis of PetroleumProducts and LubricantsTechnique Analysis ASTM EIWD-XRF Sulfur in Petroleum Products D2622Additive Elements in

25、 LubricatingOils and AdditivesD4927 IP 407Lead in Gasoline D5059 IP 228Lead in Gasoline IP 489Sulfur in Gasoline D6334Additive Elements in Lube Oils andAdditivesD6443Vanadium and Nickel IP 433Sulfur IP 447Sulfur in Automotive Fuels IP 497Chlorine and Bromine IP 503Sulfur in Ethanol as BlendingAgentI

26、P 553Si, Cr, Ni, Fe, and Cu in UsedGreasesIP 560Several Metals in Burner FuelsDerived from Waste Mineral OilsIP 593MWD-XRF Sulfur in Gasoline and Diesel D7039Silicon in Gasoline and Naphtha D7757Organic Chloride in Crude Oil D4929 CED-XRF Sulfur in Petroleum Products D4294 IP 336Sulfur in Gasoline D

27、6445Additive Elements in LubricatingOilsD6481Sulfur in Automotive Fuels D7212 IP 531Sulfur in Automotive Fuels D7220 IP 532Additive Elements in LubricatingOilsD7751Lead in Gasoline IP 352Sulfur in Automotive Fuels IP 496Low Sulfur in Automotive Fuels IP 600MED-XRF Organic Chloride in Crude Oil D4929

28、 CED-XRF Organic Chloride in Crude Oil D4929 CTABLE 2 Technically Equivalent XRF Test Methods for PetroleumProducts and LubricantsAAnalysis ASTM EI OtherSulfur by WD-XRF D2622 DIN 51400T6;JIS K3541Additive Elements by WE-XRFD4927 IP 407 DIN 51391T2Lead in Gasoline D5059 IP 228Sulfur by ED-XRF D4294

29、IP 336 ISO 8754Sulfur in Automotive Fuels D7212 IP 531Sulfur in Automotive Fuels D7220 IP 532ANadkarni, R. A., Guide to ASTM Test Methods for the Analysis of PetroleumProducts and Lubricants, 2nd edition, ASTM International, West Conshohocken,PA, 2007.D7343 1822.2 Energy Institute Standards:4IP 228

30、Determination of lead content of gasolineX-rayspectrometric methodIP 336 Determination of sulfur contentEnergy-dispersiveX-ray fluorescence methodIP 352 Determination of lead content of automotivegasolineEnergy-dispersive X-ray fluorescence spec-trometry methodIP407 Determination of barium, calcium,

31、 phosphorus, sulfurand zinc by wavelength dispersive X-ray fluorescencespectrometryIP 433 Determination of vanadium and nickel contentWavelength dispersive X-ray fluorescence spectrometryIP 447 Determination of sulfur contentWavelength disper-sive X-ray fluorescence spectrometryIP 475 Methods of tes

32、t for petroleum and its productsIP 489 Determination of low lead contents in gasolinesWavelength dispersive X-ray fluorescence spectrometryIP 496 Determination of sulfur content of automotivefuelsEnergy-dispersive X-ray fluorescence spectrom-etryIP 497 Determination of sulfur content of automotivefu

33、elsWavelength dispersive X-ray fluorescence spec-trometryIP 503 Determination of chlorine and bromine contentWavelength dispersive X-ray fluorescence spectrometryIP 531 Determination of sulfur content of automotivefuelsLow-background proportional counter energy-dispersive X-ray fluorescence spectrom

34、etry methodIP 532 Determination of the sulfur content of automotivefuelsPolarized X-ray fluorescence spectrometryIP 553 Ethanol as a Blending Component for PetrolDetermination of Sulfur ContentWDXRF MethodIP 560 Determination of Silicon, Chromium, nickel, Iron,and Copper in Used GreasesWDXRF MethodI

35、P 593 Determination of Pb, Ni, Cr, Cu, Zn, As, Cd, Tl, Sb,Co, Mn, and V in Burner Fuels derived from WasteMineral OilsWDXRF MethodIP 600 Petroleum ProductsDetermination of Low SulfurContent of Automotive FuelsEDXRF Spectrometry3. Significance and Use3.1 Accurate elemental analyses of samples of petr

36、oleumand petroleum products are required for the determination ofchemical properties, which are in turn used to establishcompliance with commercial and regulatory specifications.4. Sample Handling4.1 It is necessary to use precautions to minimize thepossibility of contamination of trace elemental an

37、alysissamples. Good laboratory practices in this area include:4.1.1 Samples received by the laboratory and required fortrace element analysis should be stored in a designated specificlocation for storage while awaiting analysis. This area, when-ever possible, should not contain samples that could co

38、ntami-nate those requiring trace element analysis.4.1.2 All laboratory equipment used specifically for traceelement analysis should be free of any source of contamina-tion. This may require that specific equipment be used only fortrace element analysis.4.1.3 Analyses of blank samples are highly reco

39、mmended.4.1.4 Sample preparation should be carried out in a cleanarea. This area should use surfaces that can be decontaminatedeasily if a spillage occurs.4.1.5 Operators should wear clean, fresh, protective glovesfor sample preparation for trace element analysis. Tests shouldbe run to confirm that

40、the gloves do not contain interferingelements or elements of interest, since they may cause con-tamination. The development of clean area sample handlingprotocols is encouraged.5. Sample PreparationNOTE 1In Test Method D4929 C, the sample is distilled to obtain anaphtha cut, which is washed with cau

41、stic and then water. The washedfraction is then used for alternate XRF measurements.5.1 Choice of Sample CarrierXRF testing requires asample cell and a support film to hold the liquid sample inplace during analysis. The choice of the sample cell or cup, thematerial in which it is held, and the type

42、of support film usedcan all influence the result.5.1.1 Sample CellThe most common cell is a plastic cup,of which various designs are available. These designs allow fora variety of sample types to be measured either in a liquid orpowder form. It is important to check that the cup type used isbest sui

43、ted for the compositions of samples to be analyzed.Liquid sample cups usually have a seal that ensures the film issealed to a level above that of the liquid in the cell and that thefilm is taut with no wrinkles.5.1.1.1 Within XRF spectrometers heat is produced, bothfrom the spectrometer components t

44、hemselves and from theinteraction of X-rays with the sample. Petroleum products thatare not stable due to volatility should only be placed intovented sample cups or special sealed sample cups specificallydesigned for volatile samples (see 8.3).5.1.1.2 The cup size may be important. Depending on thef

45、ilm type used to support the liquid, different films will sag dueto the weight of sample and relax due to chemical interaction,or heat, or both. To reduce this sagging effect, the smallestdiameter sample cups should be used. Cups with diameterswell in excess of the area detected by the spectrometer

46、arelikely to increase errors due to sagging.5.1.1.3 A number of petroleum products require heating toensure homogenization prior to analysis or to enable transfer tothe sample cell; examples include fuel oils and wax products.The sample cup should be able to withstand the temperatureused in this pro

47、cess. In general, most plastic sample cellsshould withstand temperatures up to 70 C.5.1.2 Sample Cell HolderMany manufacturers recom-mend metal holders to hold sample cups while they aretransferred into the XRF instrument. These holders can bemade from aluminum, stainless steel, or other materials.

48、It isimportant to recognize that these represent a potential spectralcontamination to the analysis either if the spectrometer is to4Available from Energy Institute, 61 New Cavendish St., London, WIG 7AR,U.K., http:/www.energyinst.org.uk.D7343 183determine an analyte that the holder is made from or i

49、f thematerial from the holder causes an interference with theanalyte. Generally, this is not a problem for elements withatomic number 30 itis advisable to check the potential contamination from thesample cup holder using a blank.5.1.3 Sample Support FilmsMany support films are avail-able from both XRF instrument manufacturers and accessorysuppliers. It is important to examine the film types specified inany method being used. There are four criteria that should beconsidered when selecting a X-ray transmission sample sup-port film:(1) Thickness of film,