资源描述

1、Designation: E 1817 03Standard Practice forControlling Quality of Radiological Examination by UsingRepresentative Quality Indicators (RQIs)1This standard is issued under the fixed designation E 1817; the number immediately following the designation indicates the year oforiginal adoption or, in the c

2、ase of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the radiological examination ofunique materials or processes, or bo

3、th, for which convention-ally designed image quality indicators (IQIs), such as thosedescribed in Practices E 747 and E 1025, may be inadequate incontrolling the quality and repeatability of the radiologicalimage.1.2 Where appropriate, representative image quality indica-tors (RQIs) may also represe

4、nt criteria levels of the acceptanceor rejection of images of discontinuities.1.3 This practice is applicable to most radiological methodsof examination.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of th

5、is standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:E 543 Practice for Evaluating Agencies that Perform Non-destructive Testing2E 747 Practice for Design, Manufacture, and

6、MaterialGrouping Classification of Wire Image Quality Indicators(IQI) Used for Radiology2E 1000 Guide for Radioscopy2E 1025 Practice for Design, Manufacture, and MaterialGrouping Classification of Hole-Type Image Quality Indi-cators (IQI) Used for Radiology2E 1316 Terminology for Nondestructive Exam

7、inations2E 1441 Guide for Computed Tomography (CT) Imaging22.2 ASNT Standards:3SNT-TC-1A Recommended Practice for Personnel Qualifi-cation in Nondestructive TestingANSI/ASNT CP-189 Standard for Qualification and Certi-fication of Nondestructive Testing Personnel2.3 Aerospace Industries Association D

8、ocument:NAS 410 Certification and Qualification of NondestructiveTesting Personnel43. Terminology3.1 DefinitionsFor definitions of terms used in this prac-tice, refer to Terminology E 1316.3.2 Definitions of Terms Specific to This Standard:3.2.1 representative quality indicator (RQI)a real part, ora

9、 fabrication of similar geometry in radiologically similarmaterial to a real part, that has features of known characteris-tics that represent all of the features for which the parts to bepurchased are being examined.4. Summary of Practice4.1 The information from an RQI image may be used tocontrol al

10、l of the parameters necessary for production exami-nation images (which look essentially like the RQI images) andis particularly effective in the practice of radioscopic andtomographic techniques. Refer to Guides E 1000 and E 1441,respectively.4.2 The designer may also use the RQI, when in complianc

11、ewith the requirements set out in this practice, to set accept orreject criteria, as applicable, to that part design.5. Significance and Use5.1 The use of RQIs is a significant departure from normalpractice in industrial radiology because it is not a standarddesign and is dependent on the applicatio

12、n, material, andprocess and therefore cannot be a simple plaque or wire. Theuse of an RQI provides documented evidence that radiologicimages have the level of quality necessary to reveal thosenonconformances for which the parts are being examined byensuring adequate spatial resolution and contrast s

13、ensitivity inthe areas of interest.1This practice is under the jurisdiction of ASTM Committee E07 on Nonde-structive Testing and is the direct responsibility of Subcommittee E07.01 onRadiology (X and Gamma) Method.Current edition approved March 10, 2003. Published May 2003. Originallyapproved in 199

14、6. Last previous edition approved in 1996 as E 1817 - 96.2Annual Book of ASTM Standards, Vol 03.03.3Available from American Society for Nondestructive Testing, 1711 ArlingatePlaza, P.O. Box 28518, Columbus, OH 43228-0518.4Available from Aerospace Industries Association of America, Inc., 1250 EyeSt.,

15、 NW, Washington, DC 20005.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.2 Where conventional IQIs conforming to Practice E 747or E 1025 can be used effectively, those practices should befollowed.6. Basis of Application6.1 The fol

16、lowing items shall be agreed upon between thepurchaser and the supplier and specified in the contract or joborder:6.1.1 Nondestructive testing (NDT) personnel shall bequalified in accordance with a nationally or internationallyrecognized NDT personnel qualification practice or standardsuch as ANSI/A

17、SNT CP-189, SNT-TC-1A, NAS 410, or asimilar document. The practice or standard used and itsapplicable revision shall be specified in the contractual agree-ment between the using parties.6.1.2 Nondestructive Testing Agency EvaluationIf a sys-tematic assessment of the capability of an NDT agency isspe

18、cified, a documented procedure such as that described inPractice E 543 shall be used as the basis for evaluation.6.1.3 Quality LevelsQuality levels to be used shall bespecified in accordance with 7.1 and 7.2.6.1.4 System Performance Using RQIsNonconformancesin RQIs used to determine system performan

19、ce shall bespecified in accordance with 8.1.1-8.1.3.6.1.5 RQI FabricationThe design and manufacture ofRQIs shall be specified in accordance with 8.3.1 and 8.3.2.6.1.6 Frequency of RQI UsageIf not in accordance with8.7.1, the frequency of RQI usage shall be specified inaccordance with 8.7.2.6.1.7 Acc

20、ept and Reject CriteriaIf used, acceptance levelsshall be specified in accordance with 8.8.1 and 8.8.2.7. Quality Levels7.1 There is no standard table of image quality levelsassociated with RQI images.7.2 Quality levels using RQIs shall be determined byagreement between the purchaser and the supplie

21、r and shall bespecified in the applicable job order or contract.8. Requirements8.1 System Performance Using RQIs:8.1.1 The manufacturing development of unique materialsor processes, or both, may produce a wide range of noncon-formances. The radiologic system should be capable of reveal-ing examples

22、of the smallest deviations from the engineeringdrawing requirements in images of examined parts.8.1.2 The cognizant design authority for the parts beingexamined shall agree that the RQI (whether actual parts orfabricated) can be used to assess and verify image quality withregard to detection of all

23、of the nonconformances of concern.8.1.3 The choice of known nonconformances that the sys-tem should have the capability of revealing in the images shallbe determined between the purchaser and the supplier and shallbe specified in the applicable job order or contract.8.2 RQI RequirementsRadiologic im

24、age quality require-ments shall be determined by RQIs that conform to thefollowing conditions:8.2.1 The geometry of the RQI must be as near as possible(65 %) to that of the parts to be examined.8.2.2 The RQIs shall be identified permanently and referredto in the examination scanplan.8.2.3 It shall b

25、e a requirement to keep an RQI register, ascanplan describing all of the parameters used to make theimages, and a precise technical description (including refer-ence images) of all of the imperfections or characteristics forwhich the RQI is being used.8.3 RQI Fabrication:8.3.1 The RQIs shall be fabr

26、icated (where they are notactual parts or sections from actual parts) from radiologicallysimilar material and from manufacturing process parameterssimilar to those of the parts to be examined.8.3.2 Large structures can be sectioned into smaller piecesto provide examples of nonconformances, provided

27、that theyare contained within a relevant geometry that produces aradiologic image similar to the original. Scatter radiation due topart geometric configuration can influence radiologic imagequality significantly.8.4 Number of RQIsThere is no limit to the number ofRQIs for the parts to be examined, p

28、rovided that each RQI isin compliance with the requirements stated in 8.1-8.3.8.5 RQI PlacementRQIs shall be exposed in strict com-pliance with the scanplan or shooting sketch. Unlike conven-tional IQIs, RQIs should be in the same position relative to thesource and detector as the part to be examine

29、d to represent thequality level accurately. When the RQI cannot be placed in thesame position relative to the source and detector as theexamination part, place the examination part in the directcenter of where the radiation beam is normal to the detector,and place the RQI further away from this cent

30、er.8.6 RQI Imaging:8.6.1 The RQI images with artifacts in the areas of interestshall be reimaged.8.6.2 The RQI image shall be provided, along with theexamination images, as part of the examination record.8.6.3 The complete set of imaging conditions shall berecorded and used when reviewing the refere

31、nce images of thefeatures in the RQI or the part being examined, or both.8.7 Frequency of Use:8.7.1 In most applications, it is not practical to image theRQI with each exposure of the part(s) being examined, but itshould as a minimum be imaged before the commencementand at the conclusion of the exam

32、ination. This is applicablewhether the examination involves a single item or a batch ofsimilar items.8.7.2 Other frequencies of use shall be determined betweenthe purchaser and the supplier and shall be specified in theapplicable job order or contract.8.8 Acceptance Levels:8.8.1 The cognizant design

33、 authority for the parts beingexamined may also choose to use the RQI images as referenceimages for indicating acceptable or rejectable conditions in theparts to be examined, provided that the original set of referenceimages is kept for reference during subsequent use of theRQI(s).8.8.2 The choice o

34、f known and quantified image(s) offeatures in the RQI to be used as accept or reject criteria shallE1817032be determined between the purchaser and the supplier and shallbe specified in the applicable job order or contract.9. Precision and Bias9.1 No statement is made about either the precision or bi

35、asof this practice for controlling the radiologic quality of imagesmade from the examination of unique materials or processes,or both, since the result indicates merely whether there isconformance to the criteria for success specified in thispractice.10. Keywords10.1 radiologic images; representativ

36、e quality indicator;RQIASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringem

37、ent of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or

38、 for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views kn

39、own to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).E1817033

展开阅读全文
相关资源
猜你喜欢
  • ASTM A690 A690M-2013 Standard Specification for High-Strength Low-Alloy Nickel Copper Phosphorus Steel H-Piles and Sheet Piling with Atmospheric Corrosion Resistance for Use in Mar.pdf ASTM A690 A690M-2013 Standard Specification for High-Strength Low-Alloy Nickel Copper Phosphorus Steel H-Piles and Sheet Piling with Atmospheric Corrosion Resistance for Use in Mar.pdf
  • ASTM A690 A690M-2013a Standard Specification for High-Strength Low-Alloy Nickel Copper Phosphorus Steel H-Piles and Sheet Piling with Atmospheric Corrosion Resistance for Use in Ma.pdf ASTM A690 A690M-2013a Standard Specification for High-Strength Low-Alloy Nickel Copper Phosphorus Steel H-Piles and Sheet Piling with Atmospheric Corrosion Resistance for Use in Ma.pdf
  • ASTM A690 A690M-2013a(2018) Standard Specification for High-Strength Low-Alloy Nickel Copper Phosphorus Steel H-Piles and Sheet Piling with Atmospheric Corrosion Resistance for Use.pdf ASTM A690 A690M-2013a(2018) Standard Specification for High-Strength Low-Alloy Nickel Copper Phosphorus Steel H-Piles and Sheet Piling with Atmospheric Corrosion Resistance for Use.pdf
  • ASTM A691 A691M-2009 Standard Specification for Carbon and Alloy Steel Pipe Electric-Fusion-Welded for High-Pressure Service at High Temperatures《高温高压条件下电融焊碳钢管和合金钢管用标准规范》.pdf ASTM A691 A691M-2009 Standard Specification for Carbon and Alloy Steel Pipe Electric-Fusion-Welded for High-Pressure Service at High Temperatures《高温高压条件下电融焊碳钢管和合金钢管用标准规范》.pdf
  • ASTM A691 A691M-2009(2014) Standard Specification for Carbon and Alloy Steel Pipe Electric-Fusion-Welded for High-Pressure Service at High Temperatures《高温高压条件下电融焊碳钢管和合金钢管用标准规格》.pdf ASTM A691 A691M-2009(2014) Standard Specification for Carbon and Alloy Steel Pipe Electric-Fusion-Welded for High-Pressure Service at High Temperatures《高温高压条件下电融焊碳钢管和合金钢管用标准规格》.pdf
  • ASTM A691 A691M-2009e1 Standard Specification for Carbon and Alloy Steel Pipe Electric-Fusion-Welded for High-Pressure Service at High Temperatures《高温高压条件下电融焊碳钢管和合金钢管用标准规格》.pdf ASTM A691 A691M-2009e1 Standard Specification for Carbon and Alloy Steel Pipe Electric-Fusion-Welded for High-Pressure Service at High Temperatures《高温高压条件下电融焊碳钢管和合金钢管用标准规格》.pdf
  • ASTM A691 A691M-2018 Standard Specification for Carbon and Alloy Steel Pipe Electric-Fusion-Welded for High-Pressure Service at High Temperatures《高温高压用电熔焊碳和合金钢管标准规范》.pdf ASTM A691 A691M-2018 Standard Specification for Carbon and Alloy Steel Pipe Electric-Fusion-Welded for High-Pressure Service at High Temperatures《高温高压用电熔焊碳和合金钢管标准规范》.pdf
  • ASTM A691-1998(2002) Standard Specification for Carbon and Alloy Steel Pipe Electric-Fusion-Welded for High-Pressure Service at High Temperatures《高温下高压装置用电熔焊碳素钢和合金钢管的标准规范》.pdf ASTM A691-1998(2002) Standard Specification for Carbon and Alloy Steel Pipe Electric-Fusion-Welded for High-Pressure Service at High Temperatures《高温下高压装置用电熔焊碳素钢和合金钢管的标准规范》.pdf
  • ASTM A691-1998(2007) Standard Specification for Carbon and Alloy Steel Pipe Electric-Fusion-Welded for High-Pressure Service at High Temperatures.pdf ASTM A691-1998(2007) Standard Specification for Carbon and Alloy Steel Pipe Electric-Fusion-Welded for High-Pressure Service at High Temperatures.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ASTM

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1