ASTM E2214-2017 Standard Practice for Specifying and Verifying the Performance of Color-Measuring Instruments《说明和鉴定颜色测定仪性能的标准实施规程》.pdf

上传人:刘芸 文档编号:530581 上传时间:2018-12-05 格式:PDF 页数:12 大小:259.65KB
下载 相关 举报
ASTM E2214-2017 Standard Practice for Specifying and Verifying the Performance of Color-Measuring Instruments《说明和鉴定颜色测定仪性能的标准实施规程》.pdf_第1页
第1页 / 共12页
ASTM E2214-2017 Standard Practice for Specifying and Verifying the Performance of Color-Measuring Instruments《说明和鉴定颜色测定仪性能的标准实施规程》.pdf_第2页
第2页 / 共12页
ASTM E2214-2017 Standard Practice for Specifying and Verifying the Performance of Color-Measuring Instruments《说明和鉴定颜色测定仪性能的标准实施规程》.pdf_第3页
第3页 / 共12页
ASTM E2214-2017 Standard Practice for Specifying and Verifying the Performance of Color-Measuring Instruments《说明和鉴定颜色测定仪性能的标准实施规程》.pdf_第4页
第4页 / 共12页
ASTM E2214-2017 Standard Practice for Specifying and Verifying the Performance of Color-Measuring Instruments《说明和鉴定颜色测定仪性能的标准实施规程》.pdf_第5页
第5页 / 共12页
亲,该文档总共12页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: E2214 16E2214 17Standard Practice forSpecifying and Verifying the Performance of Color-Measuring Instruments1This standard is issued under the fixed designation E2214; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, th

2、e year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONRecent advances in optics, electronics and documentary standard have resulted in a proliferation ofinstrumen

3、ts for the measurement of color and appearance of materials and objects. These instrumentspossess very good performance but there has been little progress toward standardizing the terminologyand procedures to quantify that performance. Therefore, the commercial literature and even somedocumentary st

4、andards are a mass of confusing terms, numbers and specifications that are impossibleto compare or interpret.Two recent papers in the literature, have proposed terms and procedures to standardize thespecification, comparison and verification of the level of performance of a color-measuringinstrument

5、.2,3 Following those procedures, those specifications can be compared to product tolerances.This becomes important so that instrument users and instrument makers can agree on how to compareor verify, or both, that their instruments are performing in the field as they were designed and testedin the f

6、actory.1. Scope1.1 This practice provides standard terms and procedures for describing and characterizing the performance of spectral and filterbased instruments designed to measure and compute the colorimetric properties of materials and objects. It does not set thespecifications but rather gives t

7、he format and process by which specifications can be determined, communicated and verified.1.2 This practice does not describe methods that are generally applicable to visible-range spectroscopic instruments used foranalytical chemistry (UV-VIS spectrophotometers). ASTM Committee E13 on Molecular Sp

8、ectroscopy and Chromatographyincludes such procedures in standards under their jurisdiction.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health pract

9、ices and determine the applicability of regulatorylimitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Rec

10、ommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:4D2244 Practice for Calculation of Color Tolerances and Color Differences from Instrumentally Measured Color CoordinatesE284 Terminology of AppearanceE1164 Practic

11、e for Obtaining Spectrometric Data for Object-Color Evaluation1 This practice is under the jurisdiction of ASTM Committee E12 on Color and Appearance and is the direct responsibility of Subcommittee E12.04 on Color andAppearance Analysis.Current edition approved Nov. 1, 2016May 1, 2017. Published No

12、vember 2016July 2017. Originally approved in 2002. Last previous edition approved in 20122016 asE2214 12E2214 16.1. DOI: 10.1520/E2214-16.10.1520/E2214-17.2 Ladson, J., “Colorimetric Data Comparison of Bench-Top and Portable Instruments,” AIC Interim Meeting, Colorimetry, Berlin, 1995.3 Rich, D., “S

13、tandardized Terminology and Procedures for Specifying and Verifying the Performance of Spectrocolorimeters,” AIC Color 97 Kyoto, Kyoto, 1997.4 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolum

14、e information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequa

15、tely depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocke

16、n, PA 19428-2959. United States12.2 Other Documents:ISO VIM International Vocabulary of Basic and General Terms in Metrology (VIM)5NIST Technical Note 1297 Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results63. Terminology3.1 Definitions of appearance terms in Termin

17、ology E284 are applicable to this practice.3.2 Definitions of metrology terms in ISO, International Vocabulary of Basic and General Terms in Metrology (VIM) areapplicable to this practice.3.3 Definitions of Terms Specific to This Standard:3.3.1 colorimetric spectrometer, nspectrometer, one component

18、 of which is a dispersive element (such as a prism, grating orinterference filter or wedge or tunable or discrete series of monochromatic sources), that is normally capable of producing as outputcolorimetric data (such as tristimulus values and derived color coordinates or indices of appearance attr

19、ibutes) as well as theunderlying spectral data from which the colorimetric data are derived.3.3.2 inter-instrument agreement, nthe closeness of agreement between the results of measurements in which two or moreinstruments from the same manufacturer and model are compared.3.3.3 inter-model agreement,

20、 nthe closeness of agreement between the results of measurements in which two or moreinstruments from different manufacturers, or of different but equivalent design, are compared.3.3.3.1 DiscussionModern instruments have such high precision that small differences in geometric and spectral design can

21、 result in significantdifferences in the performance of two instruments. This can occur even though both instruments exhibit design and performancebias which are well within the expected combined uncertainty of the instrument and within the requirements of any internationalstandard.3.3.4 mean color

22、difference from the mean, MCDM, na measure of expectation value of the performance of a color-measuringinstrument.3.3.4.1 DiscussionMCDM calculates the average color difference between a set of readings and the average of that set of readings. MCDM =average(Ei(average(Lab) Labi), for i = 1 to N read

23、ings. Any standard color difference or color tolerance equation can be usedas long as the report clearly identifies the equation being used (see Practice D2244).4. Summary of Practice4.1 This practice defines standardized terms for the most common instrument measurement performance parameters(repeat

24、ability, reproducibility, inter-instrument agreement, inter-model instrument agreement, accuracy) and describes a set ofmeasurements and artifacts, with which both the producers and users of color-measuring instruments verify or certify thespecification and performance of color-measuring instruments

25、. Following this practice can improve communications betweeninstrument manufacturers and instrument users and between suppliers and purchasers of colored materials.5. Significance and Use5.1 In todays commerce, instrument makers and instrument users must deal with a large array of bench-top and port

26、ablecolor-measuring instruments, many with different geometric and spectral characteristics. At the same time, manufacturers ofcolored goods are adopting quality management systems that require periodic verification of the performance of the instrumentsthat are critical to the quality of the final p

27、roduct. The technology involved in optics and electro-optics has progressed greatly overthe last decade. The result has been a generation of instruments that are both more affordable and higher in performance. Whathad been a tool for the research laboratory is now available to the retail point of sa

28、le, to manufacturing, to design and to corporatecommunications. New documentary standards have been published that encourage the use of colorimeters, spectrocolorimeters,and colorimetric spetrometers in applications previously dominated by visual expertise or by filter densitometers.7 Therefore, it

29、isnecessary to determine if an instrument is suitable to the application and to verify that an instrument or instruments are workingwithin the required operating parameters.5 ISO/IDE/OIML/BIPM, International Vocabulary of Basic and General Terms in MetrologyInternational Organization for Standardiza

30、tion, Geneva, Switzerland, 1984.6 TaylorBarry N., and Kuyatt, Chris E., Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results, NIST Technical Note 1297, U. S.Government Printing Office, Washington, D. C., 1984.7 ISO 13655 Spectral Measurement and Colorimetric Computati

31、on for Graphic Arts Images, International Organization for Standardization, Geneva, Switzerland.E2214 1725.2 This practice provides descriptions of some common instrumental parameters that relate to the way an instrument willcontribute to the quality and consistency of the production of colored good

32、s. It also describes some of the material standardsrequired to assess the performance of a color-measuring instrument and suggests some tests and test reports to aid in verifying theperformance of the instrument relative to its intended application.6. Instrument Performance Parameters6.1 Repeatabili

33、tyis generally the most important specification in a color-measuring instrument. Colorimetry is primarily arelative or differential measurement, not an absolute measurement. In colorimetry, there is always a standard and a trial specimen.The standard may be a real physical specimen or it may be a se

34、t of theoretical target values. The trial is usually similar to thestandard in both appearance and spectral nature. Thus, industrial colorimetry is generally a test of how well the instrument repeatsits readings of the same or nearly the same specimen over a period of minutes, hours, days, and weeks

35、.6.1.1 The ISO VIM defines repeatability as a measure of the random error of a reading and assumes that the sample standarddeviation is an estimate of repeatability. Repeatability is further defined as the standard deviation of a set of measurements takenover a specified time period by a single oper

36、ator, on a single instrument with a single specimen. This definition is similar to thatin Terminology E284, except that the ISO explicitly defines the metric of “closeness of agreement” as the sample standarddeviation. Since color is a multidimensional property of a material, repeatability should be

37、 reported in terms of themultidimensional variancecovariance matrix.6.1.2 The time period over which the readings are collected must be specified and is often qualitatively described as “short,”“medium,” or “long.” The definitions of these time frames do not overlap. This is intentional, providing c

38、learly defined milestonesin the temporal stability of test results.6.1.2.1 For the purposes of colorimetry, “short” is normally the time required to collect a set of 30 readings, taken as fast asthe instrument will allow. The actual time will vary as a function of lamp and power supply characteristi

39、cs but should be less thanone hour.6.1.2.2 “Medium” term is normally defined as, at least the period of one work shift (8 h) but less than three work shifts (oneday).6.1.2.3 “Long” term is open ended but is often described as any set readings taken over a period of at least 4 to 8 weeks. Thelongest

40、known reported study described readings taken over a period of 314 years.86.2 Reproducibility is the second most important specification in a color-measuring instrument. According to TerminologyE284, reproducibility is the closeness of agreement of the results of measurements in which one or more of

41、 the measurementparameters have been systematically changed. Thus the sample is different, the procedures or instrument are different, or the timeframe is very long. The increase of disorder over a very long time changes the instrument systematically and the set of readingsreally compares a “young”

42、instrument with an “old” instrument.6.2.1 The ISO VIM defines reproducibility as the closeness of agreement of the results of measurements in which either the timeframe is very long, in which the operator changes, the instrument changes, or the measurement conditions change. ISO againrecommends esti

43、mating this with a standard deviation. Reproducibility is further defined as the standard deviation of a set ofmeasurements taken over a specified period of time by a single operator, on a single instrument with a single specimen. Thisdefinition is similar to that in Terminology E284, except that th

44、e ISO again, explicitly defines the metric of “closeness ofagreement” as the sample standard deviation. Again, since color is a multidimensional property of a material, reproducibilityshould be reported in terms of the multidimensional variancecovariance matrix.6.2.2 The time period over which the r

45、eadings are collected must be specified. For the purposes of colorimetry, “long” termrepeatability is the most common and important type of reproducibility. Repeatability and reproducibility have traditionally beenevaluated in colorimetry by comparing the color differences of a set of readings to a

46、single reading or to the average of the set ofreadings.6.3 Inter-Instrument Agreement, as defined in 3.3.2, describes the reproducibility between two or more instruments, of identicaldesign. The ISO has no definition or description of such a concept. This is because in most test results, a method or

47、 instrumentdependent bias can be assessed. In this situation, such a test measures the consistency of the design and manufacturing process.Within the technical description of the standard geometric and spectral parameters for the measurement of diffuse reflectance factorand color, a significant amou

48、nt of latitude exists. This latitude results in a random amount of bias. For a given design, amanufacturer may reduce the random bias, often to a level less than the stability of reference materials. The most common formof test for inter-model instrument agreement is pairwise color difference assess

49、ment of a series of specimens. Various parametersare reported in the literature including the average color difference, the maximum color difference, the typical color difference, theRMS color difference or the MCDM mean color difference from the mean, taking the average of all instruments as the standardand the other as the test instrument. Using pairs of instruments and materials one can derive a multivariate confidence intervalagainst the value 0.0 difference and then test individual components to determine which attribute (lightness, chroma, hue) are the8 Ric

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1