ASTM E580 E580M-2010a 3750 Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions《在遭受地.pdf

上传人:deputyduring120 文档编号:533087 上传时间:2018-12-06 格式:PDF 页数:10 大小:370.56KB
下载 相关 举报
ASTM E580 E580M-2010a 3750 Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions《在遭受地.pdf_第1页
第1页 / 共10页
ASTM E580 E580M-2010a 3750 Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions《在遭受地.pdf_第2页
第2页 / 共10页
ASTM E580 E580M-2010a 3750 Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions《在遭受地.pdf_第3页
第3页 / 共10页
ASTM E580 E580M-2010a 3750 Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions《在遭受地.pdf_第4页
第4页 / 共10页
ASTM E580 E580M-2010a 3750 Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions《在遭受地.pdf_第5页
第5页 / 共10页
亲,该文档总共10页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: E580/E580M 10aStandard Practice forInstallation of Ceiling Suspension Systems for AcousticalTile and Lay-in Panels in Areas Subject to EarthquakeGround Motions1This standard is issued under the fixed designation E580/E580M; the number immediately following the designation indicates the

2、yearof original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Depar

3、tment of Defense.1. Scope*1.1 This practice covers the installation of suspended sys-tems for acoustical tile and lay-in panels and their additionalrequirements for two groups of buildings that are constructedto resist the effects of earthquake motions as defined byASCE 7 and the International Build

4、ing Code. These groupingsare for Seismic Design Category C and Seismic DesignCategories D, E and F.1.2 The authority having jurisdiction shall determine theapplicability of this practice.1.3 Specification C635 and Practice C636 cover suspensionsystems and their installation without special regard to

5、 seismiclateral restraint needs. They remain applicable and shall befollowed when this practice is specified.1.4 Ceilings less than or equal to 144 square feet andsurrounded by walls connected to the structure above areexempt from the requirements of this practice.1.5 This practice is not intended t

6、o stifle research anddevelopment of new products or methods. This practice is notintended to prevent the installation of any material or prohibitany design or method of construction not prescribed in thispractice, provided that any such alternative has been substan-tiated by verifiable engineering d

7、ata or full-scale dynamictesting that is acceptable to the authority having jurisdiction.1.6 Ceiling areas of 1000 ft292.9 m2 or less shall beexempt from the lateral force bracing requirements of 5.2.8.1.7 Ceilings constructed of gypsum board which is screw ornail attached to suspended members that

8、support a ceiling onone level extending from wall to wall shall be exempt from therequirements of this practice.1.8 Free floating ceilings (those not attached directly to anystructural walls) supported by chains or cables from thestructure are not required to satisfy the seismic force require-ments

9、provided they meet the following requirements:1.8.1 The design load for such items shall equal 1.4 timesthe vertical operating weight.1.8.2 Seismic interaction effects shall be considered inaccordance with 5.7.1.8.3 The connection to the structure shall allow a 360range of motion in the horizontal p

10、lane.1.9 The values stated in either inch-pound or SI units are tobe regarded as standard. Within the text, the SI units are shownin brackets. The values stated in each system are not exactequivalents; therefore, each system shall be used independentlyof the other. Combining values from the two syst

11、ems result innonconformance with the specification.1.10 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of

12、 regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C635 Specification for the Manufacture, Performance, andTesting of Metal Suspension Systems for Acoustical Tileand Lay-in Panel CeilingsC636 Practice for Installation of Metal Ceiling SuspensionSystems for Acoustical Til

13、e and Lay-In Panels2.2 Other Standards:ASCE 7 Minimum Design Loads for Buildings and OtherStructures31This practice is under the jurisdiction of ASTM Committee E33 on Buildingand Environmental Acoustics and is the direct responsibility of SubcommitteeE33.04 on Application of Acoustical Materials and

14、 Systems.Current edition approved Oct. 1, 2010. Published October 2010. Originallyapproved in 1976. Last previous edition approved in 2010 as E580 10. DOI:10.1520/E0580_E0580M-10A.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org

15、. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American Society of Civil Engineers (ASCE), 1801 AlexanderBell Drive, Reston, VA 20191 or www.pubs.asce.org.1*A Summary of Changes section appears at the end of this

16、 standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.CISCA Recommendations for Direct-hung Acoustical Tileand Lay-in Ceilings, Seismic Zones 0-24CISCA Guidelines for Seismic Restraint for Direct HungSuspended Ceiling Assemblies,

17、Seismic Zones3 earthquake; seismic; seismic re-straint; suspended ceilingFIG. 5 Supplemental Hanger Wires at Light Fixtures (continued)E580/E580M 10a9APPENDIX(Nonmandatory Information)X1. COMMENTARYX1.1 Recommendations in previous versions of this prac-tice were based in part on testing done in the

18、1980s. This,coupled with general observations from the earthquake proneareas in California have lead to the original practice.X1.2 Actual earthquake experience (most notablyNorthridge and Loma Prieta earthquakes) has shown that threemain things are critical for good performance of ceilingsystems dur

19、ing earthquakes which are:X1.2.1 Independent safety wires on light fixtures to preventdropout,X1.2.2 Minimum strength requirements for splices andcross/runner/main runner intersections, andX1.2.3 Spreader bars and independent support of suspen-sion member terminal ends at wall closures which prevent

20、panel dropout if the perimeter suspension terminal end slips offof the closure support ledge.X1.3 These observations have lead to the requirement forsafety wires on light fixtures and minimum connectionstrengths in Practice E580/E580M. This also led to the require-ment for 2-in. 50 mm perimeter supp

21、ort ledger and therequirement for independent support of terminal ends ofsuspension members.X1.4 Advent of International Building Code has raised theawareness of seismic installation requirements in areas withinthe United States where these requirements traditionally werenot a concern.X1.5 The intro

22、duction of non-traditional ceiling made ofwood and metal, as well as ceilings that do not use traditionaltee bar suspension systems, has lead to a need for an expansionof the prescriptive installation requirements. There has beenalso a general concern over the interaction of the ceiling systemwith H

23、VAC components, lights and sprinklers. This coupledwith the coming of next generation of performance basedseismic codes has lead to new interest in clear and conciserequirements for installation of ceiling systems. The result isthis current rewrite of this practice.SUMMARY OF CHANGESCommittee E33 ha

24、s identified the location of selected changes to this standard since the last issue ( E580/10)that may impact the use of this standard.(1) Added 1.4 and renumbered existing 1.41.9 to 1.5-1.10and renumbered existing 1.7.1, 1.7.2, and 1.7.3 to 1.8.1, 1.8.2,and 1.8.3.ASTM International takes no positio

25、n respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.

26、This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM I

27、nternational Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address sho

28、wn below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the ASTM website (www.astm.org/COPYRIGHT/).E580/E580M 10a10

展开阅读全文
相关资源
猜你喜欢
  • BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf
  • BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf
  • BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf
  • BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf
  • BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf
  • BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf
  • BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf
  • BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf
  • BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ASTM

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1