ASTM E906 E906M-2017 0625 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using a Thermopile Method《采用热电堆法的材料与产品热和可视烟雾释放率的标准试验方法》.pdf

上传人:cleanass300 文档编号:533752 上传时间:2018-12-06 格式:PDF 页数:27 大小:1.20MB
下载 相关 举报
ASTM E906 E906M-2017 0625 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using a Thermopile Method《采用热电堆法的材料与产品热和可视烟雾释放率的标准试验方法》.pdf_第1页
第1页 / 共27页
ASTM E906 E906M-2017 0625 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using a Thermopile Method《采用热电堆法的材料与产品热和可视烟雾释放率的标准试验方法》.pdf_第2页
第2页 / 共27页
ASTM E906 E906M-2017 0625 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using a Thermopile Method《采用热电堆法的材料与产品热和可视烟雾释放率的标准试验方法》.pdf_第3页
第3页 / 共27页
ASTM E906 E906M-2017 0625 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using a Thermopile Method《采用热电堆法的材料与产品热和可视烟雾释放率的标准试验方法》.pdf_第4页
第4页 / 共27页
ASTM E906 E906M-2017 0625 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using a Thermopile Method《采用热电堆法的材料与产品热和可视烟雾释放率的标准试验方法》.pdf_第5页
第5页 / 共27页
亲,该文档总共27页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: E906/E906M 17 An American National StandardStandard Test Method forHeat and Visible Smoke Release Rates for Materials andProducts Using a Thermopile Method1This standard is issued under the fixed designation E906/E906M; the number immediately following the designation indicates the year

2、of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method provides for determining the releasera

3、tes of heat and visible smoke (Note 1) from materials,products, or assemblies when exposed to different levels ofradiant heat.NOTE 1Visible smoke is described in terms of the obscuration oftransmitted light caused by combustion products released during the tests(see 14.2.1).1.2 This fire-test-respon

4、se method assesses heat release by athermal method, thermopile, using a radiant heat sourcecomposed of an array of four electrical resistance elements.1.3 This test method provides for radiant thermal exposureof a specimen both with and without a pilot. Piloted ignitionresults from direct flame impi

5、ngement on the specimen(piloted, point ignition) or from use of the pilot to ignite gasesevolved by pyrolysis of the specimen.1.4 Heat and smoke release are measured from the momentthe specimen is injected into a controlled exposure chamber.The measurements are continued during the period of ignitio

6、n(and progressive flame involvement of the surface in the caseof point ignition), and to such a time that the test is terminated.1.5 The apparatus described in this test method is oftenreferred to as the Ohio State University (OSU) rate of heatrelease apparatus. ConfigurationsAand B are variations o

7、n theoriginal design.1.6 This test method is suitable for exposing essentiallyplanar materials, products or assemblies to a constant, imposedexternal heat flux that ranges from 0 to 80 kW/m2.1.7 The apparatus described in this test method has beenused in two configurations. Configuration A is that w

8、hich isused by the Federal Aviation Administration for assessingmaterials for aircraft use, at an external heat flux of 35 kW/m2(DOT/FAA/AR-00/12), while configuration B is suitable, atvarious incident heat fluxes, for research and developmentpurposes.1.8 This test method does not provide informatio

9、n on thefire performance of the test specimens under fire conditionsother than those conditions specified in this test method.Known limitations of this test method are described in 1.8.1 1.8.5.1.8.1 Heat and smoke release rates depend on a number offactors, including the formation of surface char, t

10、he formationof an adherent ash, sample thickness, and the method ofmounting.1.8.2 Heat release values are a function of the specificspecimen size (exposed area) tested. Results are not directlyscaleable to different exposed surface areas for some products.1.8.3 The test method is limited to the spec

11、ified specimensizes of materials, products, or assemblies. If products are to betested, the test specimen shall be representative of the productin actual use. The test is limited to exposure of one surface; theoptions for exposed surface are vertical and horizontal facingup.1.8.4 At very high specim

12、en heat release rates, it is possiblethat flaming is observed above the stack, which makes the testinvalid.1.8.5 No general relationship has been established betweenheat release rate values obtained from horizontally and verti-cally oriented specimens. Specimens that melt and drip in thevertical ori

13、entation shall be tested horizontally.1.9 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two syst

14、ems may result in non-conformancewith the standard.1.10 Fire testing involves hazardous materials, operations,and equipment. See Section 6.1.11 This standard is used to measure and describe theresponse or materials, products, or assemblies to heat andflame under controlled conditions, but does not b

15、y itselfincorporate all factors required for fire hazard or fire risk1This test method is under the jurisdiction of ASTM Committee E05 on FireStandards and is the direct responsibility of Subcommittee E05.21 on Smoke andCombustion Products.Current edition approved Aug. 1, 2017. Published August 2017

16、. Originallyapproved in 1983. Last previous edition approved in 2014 as E906 14. DOI:10.1520/E0906-17.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international s

17、tandard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1as

18、sessment of the materials, products, or assemblies underactual fire conditions.1.12 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and det

19、ermine the applica-bility of regulatory limitations prior to use.1.13 Fire testing is inherently hazardous. Adequate safe-guards for personnel and property shall be employed inconducting these tests.1.14 This international standard was developed in accor-dance with internationally recognized princip

20、les on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D618 Practice for Conditioning Pla

21、stics for TestingE176 Terminology of Fire StandardsE1354 Test Method for Heat and Visible Smoke ReleaseRates for Materials and Products Using an Oxygen Con-sumption Calorimeter2.2 ISO Standard:ISO 13943 Fire Safety-Vocabulary32.3 Federal Aviation Administration Standard:Aircraft Material Fire Test H

22、andbook, DOT/FAA/AR-00/12, FAA Technical Center, April 200043. Terminology3.1 DefinitionsFor definitions of terms used in this testmethod refer to the terminology contained in TerminologyE176 and ISO 13943, Fire Safety-Vocabulary. In case ofconflict, the definitions given in Terminology E176 shallpr

23、evail.3.2 Definitions of Terms Specific to This Standard:3.2.1 continuous, as related to data acquisition, adjconducted at data collection intervals of5sorless.3.2.2 exposed surface, nthat surface of the specimensubjected to the incident heat.3.2.3 gas phase ignition, nignition of pyrolysis products

24、leaving a heated surface by a pilot flame or other ignitionsource that does not impinge on, nor significantly affect, forexample, by reradiation, the heated surface.3.2.4 orientation, nplane in which the exposed face of thespecimen is located during testing, either vertical or horizon-tally face upw

25、ards.3.2.5 SMOKE unitthe concentration of smoke particulatesin a cubic metre of air that reduces the percent transmission oflight through a 1-m path to 10 %. SMOKE = Standard MetricOptical Kinetic Emission.3.2.6 time to ignition, ntime between the start of the testand the presence of a flame on or o

26、ver most of the specimensurface for a period of at least 4 s.4. Summary of Test Method4.1 The specimen to be tested is injected into an environ-mental chamber through which a constant flow of air passes.The specimens exposure is determined by a radiant heatsource adjusted to produce the desired tota

27、l heat flux on thespecimen. Exposure options include: horizontal or verticalorientations; nonpiloted ignition, piloted ignition of evolvedgases, or point ignition of the surface. The changes in tempera-ture and optical density of the gas leaving the chamber aremonitored, and from this data the relea

28、se rates of heat andvisible smoke (see 14.2.1) are calculated.5. Significance and Use5.1 This test method provides a description of the behaviorof material specimens under a specified fire exposure in termsof the release rate of heat and visible smoke. It is possible todetermine the change in behavi

29、or of materials and productswith change in heat-flux exposure by testing specimens in aseries of exposures that cover a range of heat fluxes.5.2 The data obtained for a specific test describe the rate ofheat and smoke release of the specimen when exposed to thespecific environmental conditions and p

30、rocedures used inperforming that test.5.3 The entire exposed surface of the specimen will not beburning during the progressive involvement phase whenpiloted, point ignition (impingement) procedures are used.During the period of progressive surface involvement, releaserates of heat and smoke are “per

31、 square metre of originalexposed surface area” not “per square metre of flame involvedsurface.”5.4 The rates of both heat and smoke release are calculatedper square metre of original surface area exposed. If aspecimen swells, sags, delaminates, or otherwise deforms sothat the exposed surface area ch

32、anges, calculated release ratescorrespond to the original area, not to the new surface area.5.5 Heat-release values depend on mode of ignition. Gasphase ignition gives a more dimensionally consistent measureof release rate when very rapid or immediate flame involve-ment of the specimen surface occur

33、s. However, piloted, pointignition allows release-rate information to be obtained atexternal heat flux from zero up to that required for satisfactorygas-phase ignition, usually over 20 kW/m2external exposure.No correlation between the two modes of piloted ignition hasbeen established.5.6 Release rat

34、es depend on many factors, some of whichcannot be controlled. It is possible that samples that produce asurface char, a layer of adherent ash, or those that arecomposites or laminates do not attain a steady-state releaserate. Thermally thin specimens, that is, specimens whose2For referenced ASTM sta

35、ndards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from International Standardization Organization, P.O. Box 56,CH-1211, Gene

36、va 20, Switzerland.4Available from NationalTechnical Information Service (NTIS), Springfield,VA22161. An electronic version of the handbook with the latest revisions can be foundat the FAA website: http:/www.fire.tc.faa.gov/handbook.stm.E906/E906M 172unexposed surface changes temperature during peri

37、od of test,will not attain a steady-state release rate. Therefore, releaserates for a given material will depend, for example, on how thematerial is used, its thickness, and the method of mounting.5.7 Heat-release values are for the specific specimen size(exposed area) tested. Results are not direct

38、ly scalable todifferent exposed surface areas for some products.5.8 The method is limited to specimen sizes of materials inaccordance with 7.1 and to products from which it is possibleto obtain a test specimen representative of the product in actualuse.The test is limited to exposure of one surface;

39、 there are twooptions for exposure orientation: either vertical or horizontal. Ifa heat release rate of 8 kW, which is equivalent to 355 kW/m2for 150-mm 6-in. by 150-mm 6 in. vertical specimens, or533 kW/m2for 100-mm 4-in. by 150-mm 6-in. horizontalspecimens is exceeded, there is danger of combustio

40、n occur-ring above the stack.5.9 No general relationship between release rate valuesobtained from horizontally and vertically oriented specimenshas been established. Conduct tests on specimens in the form inwhich the material is oriented in end use conditions. To provideadditional information, condu

41、ct tests in the horizontal orienta-tion for those specimens that melt and drip in the verticalorientation.5.10 Release rate measurements provide useful informationfor product development by giving a quantitative measure ofspecific changes in fire test performance caused by productmodifications.5.11

42、This test method differs in both the method of exposureand the calculation procedure from the techniques used in TestMethod E1354, the cone calorimeter, which assesses heatrelease by oxygen consumption calorimetry, using a truncatedcone as a radiant source.6. Operator Safety6.1 The test procedure in

43、volves high temperatures, andcombustion processes. Therefore, it is possible for eye injuries,burns, ignition of extraneous objects or clothing, and inhalationof smoke or combustion products to occur, unless properprecautions are taken. To avoid accidental leakage of toxiccombustion products into th

44、e surrounding atmosphere, it isadvisable to evacuate the chamber, at the end of a test, into anexhaust system with adequate capacity. The operator must useheavy gloves, safety tongs or other suitable protection forremoval of the specimen holder. The venting must be checkedperiodically for proper ope

45、ration. Care shall be takne not totouch the spark igniter during operation, if used, since it carriesa substantial potential. The exhaust system of the apparatusshall be checked for proper operation before testing and shalldischarge into a building exhaust system with adequate capac-ity. The possibi

46、lity of the violent ejection of molten hotmaterial or sharp fragments from some kinds of specimenswhen irradiated must be taken into account.7. Sample Preparation7.1 The standard size for vertically mounted specimens is150 6 2mmby1506 2 mm 5.94 + 0, 0.06 in. by 5.94 + 0,0.06 in. exposed surface with

47、 thickness up to 100 mm 4.0in. The standard size for horizontally mounted specimens is150 6 2mmby1506 2 mm 5.94 + 0, 0.06 in. by 5.94 + 0,0.06 in. exposed surface, up to 45 mm 1.75 in. thick. Mountthin specimens, such as wall or floor coverings, in the samemanner as used. For example, test a wall co

48、vering to be gluedto gypsum wall board when glued to a section of gypsum boardusing the same type of adhesive. The assembly shall beconsidered the specimen to be tested. Applications requiringthicknesses greater than 45 mm 1.75 in. shall be tested at 45mm 1.75 in. thicknesses.7.2 ConditioningConditi

49、on the specimens at 23 6 3C70 6 5F and 50 6 5 % relative humidity for a minimum of24 h prior to test, or as described by Procedure A of PracticeD618, if appropriate.7.3 MountingExpose only one surface of a specimenduring a test. Insulate, on five sides, specimens that have a slabgeometry. A single layer of 0.03 6 0.01-mm 0.0012 60.005-in. aluminum foil shall be wrapped tightly on allunexposed sides with the dull side of the foil facing thespecimen surface. For products whose exposed surface is not aplane, describe mounting and method of ca

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1