ASTM F1326-2002(2006) Standard Test Method for Measuring Maximum Dry Volume of Utility Vacuum Cleaners《测量通用真空吸尘器的最大干燥空间的标准试验方法》.pdf

上传人:explodesoak291 文档编号:534661 上传时间:2018-12-06 格式:PDF 页数:5 大小:99.34KB
下载 相关 举报
ASTM F1326-2002(2006) Standard Test Method for Measuring Maximum Dry Volume of Utility Vacuum Cleaners《测量通用真空吸尘器的最大干燥空间的标准试验方法》.pdf_第1页
第1页 / 共5页
ASTM F1326-2002(2006) Standard Test Method for Measuring Maximum Dry Volume of Utility Vacuum Cleaners《测量通用真空吸尘器的最大干燥空间的标准试验方法》.pdf_第2页
第2页 / 共5页
ASTM F1326-2002(2006) Standard Test Method for Measuring Maximum Dry Volume of Utility Vacuum Cleaners《测量通用真空吸尘器的最大干燥空间的标准试验方法》.pdf_第3页
第3页 / 共5页
ASTM F1326-2002(2006) Standard Test Method for Measuring Maximum Dry Volume of Utility Vacuum Cleaners《测量通用真空吸尘器的最大干燥空间的标准试验方法》.pdf_第4页
第4页 / 共5页
ASTM F1326-2002(2006) Standard Test Method for Measuring Maximum Dry Volume of Utility Vacuum Cleaners《测量通用真空吸尘器的最大干燥空间的标准试验方法》.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: F 1326 02 (Reapproved 2006)An American National StandardStandard Test Method forMeasuring Maximum Dry Volume of Utility VacuumCleaners1This standard is issued under the fixed designation F 1326; the number immediately following the designation indicates the year oforiginal adoption or,

2、in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is applicable to any vacuum cleanerthat is classified as a util

3、ity vac.1.2 The values stated in inch-pound units are to be regardedas standard. The values in parentheses are for information only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establ

4、ish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E 177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE 691 Practice for Conducting an Interlaboratory Study toDetermine

5、 the Precision of a Test Method3. Significance and Use3.1 This test method describes a procedure to determine themaximum functional dry volume that the utility vac is capableof collecting.4. Apparatus4.1 Temperature and humidity indicators, to provide tem-perature measurements accurate to within 61F

6、 (612 C) andhumidity measurements accurate to within 62 % relativehumidity.4.2 Weighing Scale, the scale shall be accurate to 4 oz (114g) and have a weighing capacity of at least 120 lbs (54.4 kg).5. Materials5.1 Water.6. Sampling6.1 A minimum of three units of the same model vacuumcleaner selected

7、at random in accordance with good statisticalpractice shall constitute the population sample.6.1.1 To determine the best estimate of maximum dryvolume for the population of the vacuum cleaner model beingtested, the arithmetic mean of the maximum dry volume of thesample from the population shall be e

8、stablished by testing it toa 90 % confidence level within 65 % of the mean value of themaximum dry volume.6.1.2 Annex A1 provides a procedural example for deter-mining the 90 % confidence level and when the sample sizeshall be increased.NOTE 1See Annex A1 for a method for determining 90 % confidence

9、level.7. Conditioning7.1 Test RoomThe test room should be maintained at 70F6 5F (21C 6 3C) and 45 to 55 % relative humidity.7.2 Condition the water in accordance with 7.1.8. Procedure8.1 Dry Pick Up Capacity:8.1.1 Calculate the volume in gallons of the dust drum usingthe appropriate formulas, neglec

10、ting all projections into thedrum.8.1.2 Calculate all projections into the drum using theappropriate formulas in gallons.8.1.3 Subtract the total projection volumes from the dirtdrum volume to arrive at the maximum dry volume. Rounddown to the nearest14 gal (0.936 L).8.1.4 Record the maximum functio

11、nal volume in gallons(litres) within14 gal (0.936 L).9. Procedure9.1 Dry Pick Up Capacity (Alternative Method):1This test method is under the jurisdiction ofASTM Committee F11 on VacuumCleaners and is the direct responsibility of Subcommittee F11.23 on Filtration.Current edition approved July 1, 200

12、6. Published July 2006. Originally approvedin 1991. Last previous edition approved in 2002 as F 1326 02.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standard

13、s Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.9.1.1 An alternative method is allowed when the shape ofthe vacuum cleaner is irregular, and the calculations of Section8 become complex.9.1.1

14、.1 Block the inlet of the dust drum and fill it with water.9.1.1.2 Line the projections into the drum with an appropri-ate water-proof material and submerse into the dust drum.9.1.1.3 Allow the excess water to flow out of the dust drumand then measure the volume of the water remaining in the dustdru

15、m. Round down to the nearest14 gal.9.1.1.4 Record the maximum functional volume in gallons(litres) within14 gal (0.936 L).9.1.1.5 Repeat steps 9.1.1-9.1.1.4 two more times. Theaverage of the three tests represents the maximum dry func-tional volume that the utility vacuum is capable of collecting.10

16、. Precision and Bias310.1 PrecisionThese precision statements are based on aninterlaboratory test involving six (6) laboratories and four (4)units. The range of maximum functional volume of the unitswas from 4.8 to 14.6 gal.10.2 The statistics have been calculated as recommended inPractice E 691.10.

17、3 The following statements regarding repeatability limitand reproducibility limit are used as directed in Practice E 177.10.4 Repeatability (Single-Operator-and Laboratory;Multi-Day Testing)The ability of a single analyst to repeatthe test within a single laboratory.10.4.1 The expected standard devi

18、ation of repeatability ofthe measured results within a laboratory srhas been found to bethe respective values listed in Table 1.10.4.2 The 95 % repeatability limit within a laboratory, r,has been found to be the respective values listed on Table 1,where r = 2.8 (Sr).10.4.3 With 95 % confidence, it c

19、an be stated that within alaboratory a set of measured results derived from testing a unitshould be considered suspect if the difference between any twoof the three values is greater than the respective value of therepeatability limit r, listed in Table 1.10.4.4 If the absolute value of the differen

20、ce of any pair ofmeasured results from three test runs performed within a singlelaboratory is not equal to or less than the respective repeatabil-ity limit listed in Table 1, that set of test results shall beconsidered suspect.10.5 Reproducibility (Multi-day Testing and Single Opera-tor within Multi

21、ple Laboratories)The ability to repeat thetest within laboratories.10.5.1 The expected standard deviation of reproducibility ofthe average of a set of measured results between multiplelaboratories, SRhas been found to be the respective valueslisted in Table 1.10.5.2 The 95 % reproducibility limit wi

22、thin a laboratory, R,has been found to be the respective values listed in Table 1,where R = 2.8(SR).10.5.3 With 95 % confidence, it can be stated that theaverage of the measured results from a set of three test runsperformed in one laboratory, as compared to a second labora-tory, should be considere

23、d suspect if the difference betweenthose two values is greater than the respective values of thereproducibility limit, R, listed in Table 1.10.5.4 If the absolute value of the difference between theaverage of the measured results from the two laboratories is notequal to or less than the respective r

24、eproducibility limit listedin Table 1, the set of results from both laboratories shall beconsidered suspect.10.6 BiasNo justifiable statement can be made on the biasof the method to evaluate maximum dry volume of utilityvacuum cleaners. Since the true value of the property cannot beestablished by an

25、 acceptable referee method.11. Keywords11.1 dry volume; filtration; utility vacuum cleaner3Supporting data have been filed at ASTM International Headquarters and maybe obtained by requesting Research Report RR: F11-1009.TABLE 1 Repeatability and ReproducibilityMax. FunctionalVolume (gallons)Standard

26、 Deviation ofRepeatability,SrRepeatability Limit,rStandard Deviation ofReproducibility,SRReproducibility Limit,R5 gal. and less 0.068 0.190 0.380 1.063Over 5 gal. 0.118 0.3297 0.468 1.3116F 1326 02 (2006)2ANNEX(Mandatory Information)A1. DETERMINATION OF THE POPULATION MEAN HAVING 90 % CONFIDENCE INT

27、ERVALA1.1 TheoryA1.1.1 The most common and ordinarily the best singleestimate of the population mean, , is simply the arithmeticmean, X , of the individual scores (measurements) of the unitscomprising a sample taken from the population. The averagescore of these units will seldom be exactly the same

28、 as thepopulation mean; however, it is expected to be fairly close sothat in using the following procedure it can be stated with 90 %confidence that the true mean of the population, , lies within5 % of the calculated mean, X , of the sample taken from thepopulation.A1.1.2 The following procedure pro

29、vides a confidence in-terval about the sample mean that is expected to bracket , thetrue population mean, 100(1 a) % of the time where a is thechance of being wrong. Therefore, 1 a is the probability orlevel of confidence of being correct.A1.1.3 The desired level of confidence is 1 a = 0.90 or90 % a

30、s stated in Section 6. Therefore a = 0.10 or 10 %.A1.1.4 Compute the mean X , and the standard deviation, s,of the individual scores of the sample taken from the popula-tion:X51n(i 5 1nXi(A1.1)s 5n(i 5 1nXi22 (i 5 1nXi!2nn 2 1!where:n = number of units tested, andXi= the value of the individual test

31、 unit score of the ith testunit. As will be seen in the procedural example tofollow, this is the average value of the results fromthree test runs performed on an individual test unitwith the resulting set of data meeting the repeatabilityrequirements of Section 10.A1.1.5 Determine the value of the t

32、 statistic for n 1degrees of freedom (df) from Table A1.1 at a 95 % confidencelevel.NOTE A1.1The value of t is defined at t1-a/2and is read as “t at 95 %confidence”.t statistic 5 t12a/25 t0.95(A1.2)where:1a/2 = 1 0.10/2=10.05 = 0.95, or 95 %.A1.1.6 The following equations establish the upper andlowe

33、r limits of an interval centered about X that will providethe level of confidence required to assert that the true popula-tion mean lies within this interval:CIU5 X 1 ts/=n (A1.3)CIL5 X 1 ts/ =n (A1.4)where:CI = confidence interval (U upper limit; L lower limit),X = mean score of the sample taken fr

34、om the population,t = t statistic from Table A1.1 at 95 % confidence level,s = standard deviation of the sample taken from thepopulation, andn = number of units tested.A1.1.7 It is desired to assert with 90 % confidence that thetrue population mean, , lies within the interval, CIUto CIL,centered abo

35、ut the sample mean, X . Therefore, the quantityts/=n shall be less than some value, A, which shall be 5 % ofX in accordance with the sampling statement of 6.1.A1.1.8 As n , ts/=n 0. As this relationshipindicates, a numerically smaller confidence interval may beobtained by using a larger number of te

36、st units, n, for thesample. Therefore, when the standard deviation, s,ofthesample is large and the level of confidence is not reached aftertesting three units, a larger sample size, n, shall be used.A1.2 ProcedureA1.2.1 Agraphical flow chart for the following procedure isshown in Fig. A1.1.A1.2.2 Se

37、lect three units from the population for testing asthe minimum sample size.A1.2.3 Obtain individual test unit scores by averaging theresults of three test runs performed on each of the threeindividual test units. The data set resulting from the three testruns performed on each individual test unit s

38、hall meet therespective repeatability requirement found in Section 10.A1.2.4 Compute X and s of the sample.TABLE A1.1 Percentiles of the t Distributiondf t0.951 6.3142 2.9203 2.3534 2.1325 2.0156 1.9437 1.8958 1.8609 1.83310 1.81211 1.79612 1.78213 1.77114 1.76115 1.753F 1326 02 (2006)3A1.2.5 Comput

39、e the value of A where A = 0.05 ( X ).A1.2.6 Determine the statistic t for n - 1 degrees of freedomfrom Table A1.1 where n = the number of test units.A1.2.7 Compute ts/=n for the sample and compare it to thevalue to A.A1.2.8 If the value of ts/=n . A , an additional unit fromthe population shall be

40、selected and tested, and the computa-tions of A1.2.3-A1.2.7 repeated.A1.2.9 If the value of ts/=n , A , the desired 90 %confidence level has been obtained. The value of the final Xmay be used as the best estimate of the maximum dry volumefor the population.A1.3 ExampleA1.3.1 The following data are c

41、hosen to illustrate how thevalue of maximum functional volume for the population ofutility vacuum cleaners is derived. For this particular example,the measured volume test results from three test runs on eachunit are required to have a repeatability limit not exceeding0.190 as indicated in Table 1 f

42、or units of 5 gal and less.A1.3.2 Select three test units from the vacuum cleanermodel population. A minimum of three test runs shall beperformed using each test unit.A1.3.3 Test run scores for test unit No. 1:FIG. A1.1 Testing Procedure FlowchartF 1326 02 (2006)4Test run No. 1 = 4.9Test run No. 2 =

43、 5.2Test run No. 3 = 4.8A1.3.4 Maximum spread = 5.2 4.8 = 0.4. This value isgreater than the repeatability limit required in Table 1. Theresults shall be discarded and three additional test runs per-formed.A1.3.5 Test run scores for test unit No. 1:Test run No. 4 = 4.9Test run No. 5 = 5.1Test run No

44、. 6 = 5.1A1.3.6 Maximum spread = 5.1 4.9 = 0.1. This value is lessthan the repeatability limit requirement of Table 1.A1.3.7 Unit No. 1 score (4.9 + 5.1 + 5.1)/3 = 5.0.NOTE A1.2If it is necessary to continue repeated test run sets (7, 8,910, 11, 12-etc.) because the spread of data within a data set

45、is not lessthan the repeatability limit requirement stated in Table 1, there may be aproblem with the test equipment, the execution of the test procedure, orany of the other factors involved in the test procedure. Considerationshould be given to re-evaluating all aspects of the test procedure for th

46、ecause(s).A1.3.8 A minimum of two additional test units must betested, each meeting the repeatability limit requirement. Forthis procedural example, assume those units met the repeat-ability requirement and the individual unit scores area:Score of test unit No.1=5.0Score of test unit No.2=5.1Score o

47、f test unit No.3=4.9A1.3.9 X = 1/3 (5.0 + 5.1 + 4.9) = 5.0A1.3.10s 5=35.0!31 5.1!21 4.9!2# 2 5.0 1 5.1 1 4.9233 2 1!(A1.5)s = 0.1A1.3.11 A = 0.05 (5.0) = 0.25.A1.3.12 Degrees of freedom, n 1=31=2;t0.95statistic= 2.920.A1.3.13 ts/=n = 1.920(0.1)/=3 = 0.168A1.3.14 The requirement that ts/=n , A has be

48、en metbecause A is larger.A1.4 Thus, the value of X , 5.0 gal represents the maximumfunctional volume of the utility vacuum and may be used as thebest estimate of the volume for the population mean.ASTM International takes no position respecting the validity of any patent rights asserted in connecti

49、on with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed t

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1