ASTM F1743-2017 Standard Practice for Rehabilitation of Existing Pipelines and Conduits by Pulled-in-Place Installation of Cured-in-Place Thermosetting Resin Pipe (CIPP)《通过现场硫化热固性树.pdf

上传人:wealthynice100 文档编号:535544 上传时间:2018-12-06 格式:PDF 页数:8 大小:156.09KB
下载 相关 举报
ASTM F1743-2017 Standard Practice for Rehabilitation of Existing Pipelines and Conduits by Pulled-in-Place Installation of Cured-in-Place Thermosetting Resin Pipe (CIPP)《通过现场硫化热固性树.pdf_第1页
第1页 / 共8页
ASTM F1743-2017 Standard Practice for Rehabilitation of Existing Pipelines and Conduits by Pulled-in-Place Installation of Cured-in-Place Thermosetting Resin Pipe (CIPP)《通过现场硫化热固性树.pdf_第2页
第2页 / 共8页
ASTM F1743-2017 Standard Practice for Rehabilitation of Existing Pipelines and Conduits by Pulled-in-Place Installation of Cured-in-Place Thermosetting Resin Pipe (CIPP)《通过现场硫化热固性树.pdf_第3页
第3页 / 共8页
ASTM F1743-2017 Standard Practice for Rehabilitation of Existing Pipelines and Conduits by Pulled-in-Place Installation of Cured-in-Place Thermosetting Resin Pipe (CIPP)《通过现场硫化热固性树.pdf_第4页
第4页 / 共8页
ASTM F1743-2017 Standard Practice for Rehabilitation of Existing Pipelines and Conduits by Pulled-in-Place Installation of Cured-in-Place Thermosetting Resin Pipe (CIPP)《通过现场硫化热固性树.pdf_第5页
第5页 / 共8页
亲,该文档总共8页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: F1743 17Standard Practice forRehabilitation of Existing Pipelines and Conduits by Pulled-in-Place Installation of Cured-in-Place Thermosetting ResinPipe (CIPP)1This standard is issued under the fixed designation F1743; the number immediately following the designation indicates the year

2、oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This practice describes the procedures for the recon-str

3、uction of pipelines and conduits (2 to 96 in. (5 to 244 cm)diameter) by the pulled-in-place installation of a resin-impregnated, flexible fabric tube into an existing conduit andsecondarily inflated through the inversion of a calibration hoseby the use of a hydrostatic head or air pressure (see Fig.

4、 1). Theresin is cured by circulating hot water or by the introduction ofcontrolled steam into the tube. When cured, the finishedcured-in-place pipe will be continuous and tight fitting. Thisreconstruction process may be used in a variety of gravity andpressure applications such as sanitary sewers,

5、storm sewers,process piping, electrical conduits, and ventilation systems.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.NOTE 1There

6、 are no ISO standards covering the primary subjectmatter of this practice.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine

7、 the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D543 Practices for Evaluating the Resistance of Plastics toChemical ReagentsD638 Test Method for Tensile Properties of PlasticsD790 Test Methods for Flexural Properties of Unreinforcedand Reinforced

8、 Plastics and Electrical Insulating Materi-alsD903 Test Method for Peel or Stripping Strength of Adhe-sive BondsD1600 Terminology forAbbreviated Terms Relating to Plas-ticsD1682 Test Method for Breaking Load and Elongation ofTextile Fabric (Withdrawn 1992)3D3039/D3039M Test Method for Tensile Proper

9、ties of Poly-mer Matrix Composite MaterialsD3567 Practice for Determining Dimensions of “Fiberglass”(Glass-Fiber-Reinforced Thermosetting Resin) Pipe andFittingsD4814 Specification for Automotive Spark-Ignition EngineFuelD5813 Specification for Cured-In-Place ThermosettingResin Sewer Piping SystemsE

10、797 Practice for Measuring Thickness by Manual Ultra-sonic Pulse-Echo Contact MethodF412 Terminology Relating to Plastic Piping SystemsF1216 Practice for Rehabilitation of Existing Pipelines andConduits by the Inversion and Curing of a Resin-Impregnated Tube2.2 AWWA Standard:4M28 Manual on Cleaning

11、and Lining Water Mains42.3 NASSCO Standard:5Recommended Specifications for Sewer Collection SystemRehabilitation3. Terminology3.1 GeneralDefinitions are in accordance with Terminol-ogy F412. Abbreviations are in accordance with TerminologyD1600, unless otherwise indicated.1This practice is under the

12、 jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.67 onTrenchless Plastic Pipeline Technology.Current edition approved Feb. 1, 2017. Published February 2017. Originallyapproved in 1996. Last previous edition approved in 2016 as F1743 08

13、(2016).DOI: 10.1520/F1743-17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of th

14、is historical standard is referenced onwww.astm.org.4Available from American Water Works Association (AWWA), 6666 W. QuincyAve., Denver, CO 80235, http:/www.awwa.org.5Available from the National Association of Sewer Service Companies,NASSCO 11521 Cronridge Drive, Suite J Owings Mills, MD 21117, http

15、:/www.nassco.org.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on sta

16、ndardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.13.2 Definitions of Terms Specific to This Standard:3.2.1 calibration hosean impermeable

17、 bladder which isinverted within the resin-impregnated fabric tube by hydro-static head or air pressure and may optionally be removed orremain in place as a permanent part of the installed cured-in-place pipe as described in 5.2.2.3.2.2 cured-in-place pipe (CIPP)a hollow cylinder con-sisting of a fa

18、bric tube with cured (cross-linked) thermosettingresin. Interior or exterior plastic coatings, or both, may beincluded. The CIPP is formed within an existing pipe and takesthe shape of and fits tightly to the pipe.3.2.3 delaminationseparation of layers of the CIPP.3.2.4 dry spotan area of fabric of

19、the finished CIPP whichis deficient or devoid of resin.3.2.5 fabric tubeflexible needled felt, or equivalent, wo-ven or nonwoven material(s), or both, formed into a tubularshape which during the installation process is saturated withresin and holds the resin in place during the installation andcurin

20、g process.3.2.6 inversionthe process of turning the calibration hoseinside out by the use of water pressure or air pressure.3.2.7 lifta portion of the CIPP that is a departure from theexisting conduit wall forming a section of reverse curvature inthe CIPP.4. Significance and Use4.1 This practice is

21、for use by designers and specifiers,regulatory agencies, owners, and inspection organizations whoare involved in the rehabilitation of conduits through the use ofa resin-impregnated fabric tube pulled-in-place through anexisting conduit and secondarily inflated through the inversionof a calibration

22、hose. Modifications may be required forspecific job conditions.5. Recommended Materials and Manufacture5.1 GeneralThe resins, fabric tube, tube coatings, or othermaterials, such as the permanent calibration hose when com-bined as a composite structure, shall produce CIPP that meetsthe requirements o

23、f this specification.5.2 CIPP Wall CompositionThe wall shall consist of aplastic coated fabric tube filled with a thermosetting (cross-linked) resin, and if used, a filler.5.2.1 Fabric TubeThe fabric tube should consist of one ormore layers of flexible needled felt, or equivalent, woven ornonwoven m

24、aterial(s), or both, capable of carrying resin,withstanding installation pressures, and curing temperatures.The material(s) of construction should be able to stretch to fitirregular pipe sections and negotiate bends. Longitudinal andcircumferential joints between multiple layers of fabric shouldbe s

25、taggered so as not to overlap. The outside layer of thefabric tube should have an impermeable flexible coating(s)whose function is to contain the resin during and after fabrictube impregnation. The outer coating(s) must facilitate moni-toring of resin saturation of the material(s) of construction of

26、the fabric tube. The fabric tube should be fabricated to a sizethat, when installed, will tightly fit the internal circumferenceand the length of the original conduit. Allowance should bemade for circumferential and longitudinal stretching of thefabric tube during installation. As required, the fabr

27、ic tubeshould meet minimum tensile strength requirements in thelongitudinal and transverse directions as specified in 7.1. Allthe material(s) of construction for the fabric tube should becompatible with the resin system used.5.2.2 Calibration Hose:5.2.2.1 Removable Calibration HoseThe removable cali

28、-bration hose should consist of an impermeable plastic, orimpermeable plastic coating(s) on flexible woven or nonwovenmaterial(s), or both, that do not absorb resin and are capable ofbeing removed from the CIPP.5.2.2.2 Permanent Calibration HoseThe permanent cali-bration hose should consist of an im

29、permeable plastic coatingon a flexible needled felt or equivalent woven or nonwovenmaterial(s), or both, that are capable of absorbing resin and areof a thickness to become fully saturated with resin. Thecalibration hose should be translucent to facilitate post-installation inspection. The calibrati

30、on hose should be fabri-cated to a size that, when installed, will tightly fit the internalcircumference and the length of the resin saturated fabric tube.Once inverted, the calibration hose becomes part of the fabrictube, and once properly cured, should bond permanently withthe fabric tube. The pro

31、perties of the calibration hose shouldmeet minimum tensile strength requirements in the longitudi-nal and transverse directions as specified in 7.1. All theFIG. 1 Cured-in-Place Pipe Installation MethodsF1743 172material(s) of construction for the calibration hose should becompatible with the resin

32、system used.5.2.3 ResinA chemically resistant isophthalic basedpolyester, or vinyl ester thermoset resin and catalyst system oran epoxy resin and hardener that is compatible with theinstallation process should be used. The resin should be able tocure in the presence of water and the initiation tempe

33、rature forcure should be less than 180F (82.2C). The cured resin/fabrictube system, with or without the calibration hose, shall beexpected to have as a minimum the initial structural propertiesgiven in Table 1. These physical properties should be deter-mined in accordance with Section 8. The cured r

34、esin/fabrictube system, with or without the calibration hose, should meetthe minimum chemical resistance requirements as specified in7.2.6. Installation Recommendations6.1 Cleaning and Pre-Inspection :6.1.1 Prior to entering access areas, such as manholes, andperforming inspection or cleaning operat

35、ions, an evaluation ofthe atmosphere to determine the presence of toxic or flammablevapors or lack of oxygen must be undertaken in accordancewith local, state, or federal safety regulations.6.1.2 Cleaning of PipelineAll internal debris should beremoved from the original pipeline. Gravity pipes shoul

36、d becleaned with hydraulically powered equipment, high-velocityjet cleaners, or mechanically powered equipment in accordancewith NASSCO Recommended Specifications for Sewer Col-lection System Rehabilitation. Pressure pipelines should becleaned with cable attached devices or fluid propelled devicesin

37、 accordance with AWWA M28.6.1.3 Inspection of PipelinesInspection of pipelinesshould be performed by experienced personnel trained inlocating breaks, obstacles, and service connections by closed-circuit television or man entry. The interior of the pipelineshould be carefully inspected to determine t

38、he location of anyconditions that may prevent proper installation of the impreg-nated tube, such as protruding service taps, collapsed orcrushed pipe, and reductions in the cross-sectional area of morethan 40 %. These conditions should be noted so that they canbe corrected.6.1.4 Line ObstructionsThe

39、 original pipeline should beclear of obstructions such as solids, dropped joints, protrudingservice connections, crushed or collapsed pipe, and reductionsin the cross-sectional area of more than 40 % that may hinderor prevent the installation of the resin-impregnated fabric tube.If inspection reveal

40、s an obstruction that cannot be removed byconventional sewer-cleaning equipment, then a point-repairexcavation should be made to uncover and remove or repair theobstruction.6.2 Resin ImpregnationThe fabric tube should be totallyimpregnated with resin (wet-out) and run through a set ofrollers separat

41、ed by a space, calibrated under controlled con-ditions to ensure proper distribution of resin. The volume ofresin used should be sufficient to fully saturate all the voids ofthe fabric tube material, as well as all resin-absorbing materialof the calibration hose at nominal thickness and diameter. Th

42、evolume should be adjusted by adding 3 to 15 % excess resin toallow for the change in resin volume due to polymerization, thechange in resin volume due to thermal expansion orcontraction, and resin migration through the perforations of thefabric tube and out onto the host pipe.6.3 BypassingIf bypass

43、ing of the flow is required aroundthe sections of pipe designated for reconstruction, the bypassshould be made by plugging the line at a point upstream of thepipe to be reconstructed and pumping the flow to a downstreampoint or adjacent system. The pump and bypass lines should beof adequate capacity

44、 and size to handle the flow. Serviceswithin this reach will be temporarily out of service.6.3.1 Public advisory services shall notify all parties whoseservice laterals will be out of commission and advise againstwater usage until the main line is back in service.6.4 Installation Methods:6.4.1 Perfo

45、ration of Resin-Impregnated TubePrior to pull-ing the resin-impregnated fabric tube in place, the outerimpermeable plastic coating may optionally be perforated.When the resin-impregnated fabric tube is perforated, thisshould allow resin to be forced through the perforations and outagainst the existi

46、ng conduit by the force of the hydrostatic heador air pressure against the inner wall of the calibration hose.The perforation should be done after fabric tube impregnationwith a perforating roller device at the point of manufacture orat the jobsite. Perforations should be made on both sides of thela

47、y-flat fabric tube covering the full circumference with aspacing no less than 1.5 in. (38.1 mm) apart. Perforating slitsshould be a minimum of 0.25 in. (6.4 mm) long.6.4.2 Pulling Resin-Impregnated Tube into PositionThewet-out fabric tube should be pulled into place using a powerwinch. The saturated

48、 fabric tube should be pulled through anexisting manhole or other approved access to fully extend tothe next designated manhole or termination point. Care shouldbe exercised not to damage the tube as a result of frictionduring pull-in, especially where curvilinear alignments, multi-linear alignments

49、, multiple offsets, protruding services, andother friction-producing host pipe conditions are present. Oncethe fabric tube is in place, it should be attached to a verticalstandpipe so that the calibration hose can invert into the centerof the resin-impregnated fabric tube. The vertical standpipeshould be of sufficient height of water head to hold the fabrictube tight to the existing pipe wall, producing dimples at sideconnections. A device such as a dynamometer or load cellshould be provided on the winch or cable to monitor the pullingforce. Measure the ove

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1