1、Designation: F969 11Standard Practice forConstruction of Chain-Link Tennis Court Fence1This standard is issued under the fixed designation F969; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year of last revision. A number in

2、 parentheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers fencing around tennis courts, builtfrom various types of chain-link fabric and framework mate-rials, and installation pract

3、ices for same.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 This standard does not purport to address all of thesafety concerns

4、, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2A392 Specification for Zinc-Coated Steel Ch

5、ain-LinkFence FabricA491 Specification for Aluminum-Coated Steel Chain-LinkFence FabricA824 Specification for Metallic-Coated Steel MarcelledTension Wire for Use With Chain Link FenceF552 Terminology Relating to Chain Link FencingF567 Practice for Installation of Chain-Link FenceF626 Specification f

6、or Fence FittingsF668 Specification for Polyvinyl Chloride (PVC) and OtherOrganic Polymer-Coated Steel Chain-Link Fence FabricF900 Specification for Industrial and Commercial SwingGatesF934 Specification for Colors for Polymer-Coated ChainLink Fence MaterialsF1043 Specification for Strength and Prot

7、ective Coatingson Steel Industrial Fence FrameworkF1083 Specification for Pipe, Steel, Hot-Dipped Zinc-Coated (Galvanized) Welded, for Fence StructuresF1345 Specification for Zinc-5 % Aluminum-MischmetalAlloy-Coated Steel Chain-Link Fence FabricF1664 Specification for Poly(Vinyl Chloride) (PVC) andO

8、ther Conforming Organic Polymer-Coated Steel TensionWire Used with Chain-Link Fence2.2 Chain Link Fence Manufacturers Institute:WLG 2445 Chain Link Fence Wind Load Guide for theSelection of Line Post and Line Post Spacing33. Terminology3.1 DefinitionsSee Definitions F552 for definitions ofterms used

9、 in this practice.4. Summary of Practice4.1 This practice is intended primarily to guide thoseresponsible for or concerned with the design and installation ofchain-link fencing around tennis courts.4.2 This practice does not intend to preclude any practicethat has proven equal to or given better per

10、formance undervarying conditions such as location, weather, intended use, etc.5. Significance and Use5.1 The intended use of this practice is for 10- or 12-ft (3050or 3660 mm) high chain-link fencing as complete enclosuresaround single or multiple tennis courts, or as backstops ateither end of tenni

11、s courts.5.2 This practice is not intended for applications wherefencing higher than 12 ft (3660 mm) is desired for a specialapplication.5.3 Caution Regarding Windscreens If wind screens areto be installed at the time of fence erection or at a later time, itis advisable to use stronger framework and

12、 parts and closerspacing of posts or back bracing depending upon the type ofscreening material to be used, area of fence to be covered, andlocal wind conditions. The Chain Link Fence ManufacturersInstitutes (CLFMI), Guide WLG 2445, provides the designerwith the process to select the post size and po

13、st spacing.6. Classification6.1 The four types of chain-link fencing described in thispractice are classified as follows:1This practice is under the jurisdiction of ASTM Committee F14 on Fences andis the direct responsibility of Subcommittee F14.10 on Specific Applications.Current edition approved J

14、une 1, 2011. Published June 2011. Originallyapproved in 1986. Last previous edition approved in 2007 as F969 - 07. DOI:10.1520/F0969-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume in

15、formation, refer to the standards Document Summary page onthe ASTM website.3Available from Chain Link Fence Manufacturers Institute, 10015 Old ColumbiaRoad, Suite B-215, Columbia, MD 21046, http:/www.chainlinkinfo.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohock

16、en, PA 19428-2959, United States.6.1.1 Type IBuilt with aluminum-coated steel chain-linkfence fabric as specified in Specification A491.6.1.2 Type IIBuilt with zinc-coated steel chain-link fencefabric as specified in Specification A392, Class 1 or Class 2coating, as selected.6.1.3 Type IIIBuilt with

17、 zinc-5% aluminum-mischmetalalloy-coated steel chain-link fence fabric as specified in Speci-fication F1345, in a choice of Class 1 or Class 2 coating, asselected.6.1.4 Type IVBuilt with polymer-coated steel chain-linkfence fabric as specified in Specification F668, in a choice ofClass 1, Class 2a,

18、or Class 2b coating, as selected.7. Ordering Information7.1 Purchase orders, construction specifications, or detaileddrawings should include the following information:7.1.1 Quantity or total measurements in lineal feet of fenceand gates.7.1.2 Type of fence fabric and gauge of wire; Type I, TypeII (s

19、ee 6.1.2), Type III (see 6.1.3), Type IV (see 6.1.4), gaugeof wire (see 8.1.3).7.1.3 Class of metallic-coated fence fabric Type II (Class 1or Class 2) (see 6.1.2), Type III (Class 1 or Class 2) (see 6.1.3).7.1.4 Class of Type IV polymer-coated fence fabric, Class 1,Class 2a or Class 2b (see 6.1.4) a

20、nd color (see 8.1.2).7.1.5 If framework, fittings and gates are to be color coated,select color from Specification F934.7.1.6 Height of fence (10 or 12 ft (3050 or 3660 mm).7.1.7 Number of horizontal rails and location.7.1.8 Bottom tension wire, if specified.7.1.9 Depth and diameter of concrete post

21、 footings, if otherthan as indicated in Practice F567.7.1.10 Spacing of line posts, if other than as indicated inPractice F567.7.1.11 Any details peculiar to the project, such as specialfinishing of tops of concrete post footings, setting of posts inconcrete curbs, etc. (see 9.2.2 and 9.2.3).NOTE 1A

22、 typical ordering description is as follows: 360 lineal ft(109.7 m) chain-link tennis court fence to make a full enclosure 60 by 120ft (18.3 by 36.6 m) with 3 ft (914 mm) gate at one corner, Type I, 12 ft(3660 mm) high, 3 horizontal rails (top, middle, and bottom), furnishedand erected as shown on t

23、he enclosed drawing, and in accordance withASTM F969.7.2 A detailed drawing or drawings showing the completelayout of the fence line, together with typical elevations, detailsof pavement around post footings, etc., should be a part of thepurchase order or construction contract.8. Materials8.1 Chain-

24、Link Fabric:8.1.1 If Type II or Type III is selected, indicate whetherClass 1 or 2 is desired.8.1.2 If Type IV is selected, indicate whether Class 1, 2a, or2b is desired, and select color of fabric coating in accordancewith Specification F934.8.1.3 Size of wire shall be 0.120 in. (3.05 mm) 11 gauge

25、or0.148 in. (3.76 mm) 9 gauge. If polymer-coated Type IV fabricis selected, the wire size gauge is the gauge of the metallic-coated core wire.8.1.4 Size of fabric mesh shall be 134 in. (44 mm).8.1.5 Height of fabric shall be 10 or 12 ft (3050 or 3660mm), as selected.8.1.6 Fabric selvage shall be knu

26、ckled top and bottom.8.2 Posts:8.2.1 Posts shall be as selected from Specifications F1043and F1083. If polymer-coated, specify type of coating andcolor.8.2.2 The posts shall not be splice-welded.8.3 Horizontal Rails:8.3.1 Horizontal rails shall be as selected from Specifica-tions F1043 and F1083. If

27、 polymer-coated, specify type ofcoating and color.8.3.2 All fences shall have a top rail. Fences 12 ft (3660mm) in height shall have a continuous middle rail. Additionalrails at mid-points or at the bottom of the fence may bespecified.8.4 Bottom Tension Wire:8.4.1 Bottom tension wire shall be used e

28、xcept wherecontinuous bottom rail is specified.8.4.2 Bottom tension wire shall be in accordance withSpecification A824 for metallic coated chain link fabric andSpecification F1664 for polymer-coated chain link fabric.8.5 Fittings:8.5.1 All fittings shall conform to Specification F626.IfType IV fabri

29、c is selected and polymer-coated posts and railsare also selected, all fittings shall be polymer coated asspecified in Specification F626, Section 11.8.6 Gates:8.6.1 All gates shall be fabricated in accordance withSpecification F900.8.6.2 Minimum width of gate opening shall be 3 ft (914mm).8.6.3 All

30、 single walk gates shall be 7 ft (2133 mm) highwith a transom panel above the gate extending to full height ofthe fence.8.6.4 Gates shall have hinges to provide a full 180 swingfrom the closed to the open position.8.6.5 Gate latch shall have provision for secure locking witha padlock.8.6.6 Gate latc

31、h shall have a built-in provision to permit thegate to open outward only.9. Installation9.1 Lay out the fence lines as shown in Fig. 1, Fig. 2,orFig.3.9.2 Installation shall be in accordance with Practice F567with the following additional provisions or exceptions:9.2.1 Unless otherwise specified, th

32、e chain-link fabric shallbe placed on the playing side of the fence enclosure orbackstops.9.2.2 If fence is installed in concrete curbs around theperimeter of the tennis court(s), provide sleeves in the curbs forthis purpose, then set the posts as indicated in Practice F567.9.2.3 Since in most cases

33、 it is impractical to pave the courtsafter setting the posts, it becomes necessary to cut through thefinished pavement and excavate the post holes. The contractspecifications shall indicate whether the concrete footingsaround the posts should be brought up to finished grade andF969 112trowelled to a

34、 crown, or whether they should be left 6 in. (152mm) below finished grade to allow for cover with black top asdescribed in Practice F567. If the latter method is selected, thecontract specifications shall stipulate who is responsible forinstalling the black top cover over the footings.9.2.4 Install

35、chain-link fabrics with bottom 1 in. (25 mm)maximum above finished pavement.9.2.5 Where bottom tension wire is used, it shall be attachedto the bottom diamond of the chain-link fabric.10. Keywords10.1 tennis court fence; chain link; tension wire; bottomrail; 134 in. (44 mm) chain link meshNOTESee Ta

36、ble 1 for SI equivalents.FIG. 1 Typical Fence Layout for Complete Enclosure of OneStandard 36 by 78 ft (11 m by 23.8 m) Doubles CourtF969 113NOTESee Table 1 for SI equivalents.FIG. 2 Typical Fence Layout for Backstops at Either End of One Standard 36 by 78 ft (11 m by 23.8 m) Doubles CourtF969 114AS

37、TM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are e

38、ntirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards

39、and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee

40、 on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or

41、 at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the ASTM website (www.astm.org/COPYRIGHT/).NOTESee Table 1 for SI equivalents.FIG. 3 Typical Fence Layout for Com

42、plete Enclosure of Two or More Standard 36 by 78 ft (11 m by 23.8 m) Doubles CourtsTABLE 1 SI Reference Chart12 ft 0 in. = 3.7 m (3 660 mm)21 ft 0 in. = 6.4 m (6 400 mm)48 ft 0 in. = 14.6 m (14 630 mm)60 ft 0 in. = 18.3 m (18 288 mm)108 in. 0 in. = 32.9 m (32 918 mm)120 ft 0 in. = 36.6 m (36 576 mm)156 ft. 0 in. = 47.5 m (47 540 mm)F969 115