1、Designation: F 2341 05Standard Practice forUser Requirements for Livestock, Meat, and PoultryEvaluation Devices or Systems1This standard is issued under the fixed designation F 2341; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,

2、the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the requirements for users oflivestock, meat, and poultry evaluation devices or syst

3、ems usedto measure and record composition or quality constituents oflive animals, carcasses, and individual cuts of meat, whenthose devices or systems provide data that is used to determineeconomic value. Areas covered include: installation, operatortraining, operation, verification, inspection and

4、maintenance ofthese evaluation devices or systems, and documentation ofprocedures for retention of original data.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate sa

5、fety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2F 2463 Terminology for Livestock, Meat, and PoultryEvaluation Systems3. Terminology3.1 For definitions relating to livestock, meat, and poultryevaluation syste

6、ms, see Terminology F 2463.3.2 Definitions:3.2.1 device operator, nany individual whose job respon-sibilities include the operation of an evaluation device orsystem.3.2.2 document, npermanent physical record, paper orelectronic.3.2.3 documentation, nuse of documents in authenticatingor substantiatin

7、g an act that may include users guides,technical manuals, setup and installation instructions, labeling,and procedures for retaining original data.3.2.4 original data, ninitial data recorded by the device orsystem.3.2.5 production day, nperiod not exceeding 24 consecu-tive hours beginning with the i

8、nitial production shift.3.2.6 user, nperson or entity that employs an evaluationsystem or device to determine value of live animals, carcasses,or individual cuts of meat or poultry.4. Significance and Use4.1 There are several live animal or carcass evaluationdevices or systems used or under developm

9、ent for use indetermination of economic value of live animals, carcasses, orindividual cuts of meat. The correct use of these devices orsystems may affect the reliability of the data.4.2 This practice provides user requirements for installation,operator training, operation, verification, inspection,

10、 mainte-nance, and retention of original data.5. Procedure5.1 InstallationAccurate and consistent results can onlybe obtained from a device or equipment that is properlyinstalled and operated. The user shall maintain documentationthat, at the time of installation, the measuring device wasproperly in

11、stalled according to design specifications and manu-facturers requirements.5.2 Operator Training:5.2.1 The user shall establish a documented training pro-gram which shall include an operator manual to ensure deviceoperators are familiar with the design and operating character-istics of the devices o

12、r systems that the user installs, maintains,and operates. The user shall properly train device operators andmaintain documentation that device operators are properlytrained. Assistance in operator training may be obtained fromseveral sources including, but not limited to, device manufac-turer, manuf

13、acturer device manuals, or trained service person-nel.5.2.2 For those devices or systems requiring an operator, theuser shall develop and maintain individual operator perfor-mance records, including individual operator error rates, whichshall be measured against standards established by the user.1Th

14、is practice is under the jurisdiction of ASTM Committee F10 on Livestock,Meat, and Poultry Evaluation Systems and is the direct responsibility of Subcom-mittee F10.30 on User Requirements.Current edition approved Oct. 1, 2005. Published October 2005. Originallyapproved in 2003. Last previous edition

15、 approved in 2003 as F 2341 03.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International,

16、 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.The user shall have a documented corrective action plan foridentifying and correcting potential sources of operator errorspecific to the evaluation device or system. The user shallmaintain records documenting when i

17、t has implemented itscorrective action plan.5.3 Operation:5.3.1 User shall ensure that the device or system is operatedas recommended by the manufacturer, consistent with themanufacturers current instruction manual, unless an alterna-tive method of use has been established by the user consistentwith

18、 ASTM Committee F10 standards and disclosed to theseller or appropriate government agency, or both, when re-quired by law or regulation as an alternate method.5.3.2 User shall develop, document and make available tothe seller and appropriate government agency, when requiredby law or regulation, a co

19、ntingency plan for any alternate valuedetermination process to be used in the event of equipmentfailure.5.3.3 User shall disclose to the seller and appropriategovernment agency, when required by law or regulation, aplanned change in the type of device or system used for valuedetermination prior to i

20、mplementation.5.4 VerificationUser shall verify and document the accu-racy of a device or system by the proper test method, prior tothe initial use of the device on each production day or morefrequently if recommended by the manufacturer. Re-verification of the accuracy of the device should occur wh

21、en-ever damage is suspected to have occurred, when significantrepairs have been made, or as circumstances warrant.5.5 InspectionThe user shall, utilizing manufacturersrecommendations, develop an inspection checklist and conductand document the inspection in conjunction with the produc-tion day verif

22、ication (see 5.4). The inspection shall include thedevice or system, all auxiliary equipment, and environmentalconditions that may affect the device or operator performance.5.6 Maintenance:5.6.1 User shall perform routine maintenance as needed oras recommended, or both, by the manufacturer.5.6.2 Ina

23、ccurate devices shall be corrected or removed fromuse by the user.5.7 Retention of Original Data:5.7.1 The user shall establish and document proceduresused for retention of original data.5.7.2 The user shall develop and implement procedures todocument the exclusion of original data or substitution o

24、f datafor original data. The user shall disclose to the seller any timethe user excludes original data or substitutes data for originaldata.6. Keywords6.1 evaluation devices or systems; livestock; meat; poultry;user requirementsASTM International takes no position respecting the validity of any pate

25、nt rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision

26、at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comme

27、nts will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted

28、 by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).F2341052