1、Designation: F2653 11 (Reapproved 2015)F2653 16 An American National StandardStandard Specification forPaintball Valve Male Threaded Connection for Use withApproved Cylinders1This standard is issued under the fixed designation F2653; the number immediately following the designation indicates the yea
2、r oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers the male threaded connection
3、used to connect a CO2 Control Valve or Compressed AirGasRegulator with an a normal working output pressure of 10 342 kPa (1800 psig) or less for use with a paintball marker to a DOTapproved cylinder.1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are
4、 for information only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to
5、 use.2. Referenced Documents2.1 ASTM Standards:2D2240 Test Method for Rubber PropertyDurometer HardnessF1750 Specification for Paintball Marker Threaded-Propellant Source InterfaceF2030 Specification for Paintball Cylinder Burst Disk Assemblies2.2 Military Standards:3AMS7277 O-Ring Dash SizesMS28775
6、 Packing, Preformed, Hydraulic, +275 Deg. F (“O”-Ring)2.3 CGA Standards:4CGA S-1.1 Pressure Relief Device Standards-Part 1-Cylinders for Compressed Gases2.4 Federal Standards:5FED-STD-H28/9A24 March 1989 Federal Standard Screw-Thread Standards for Federal Services Section 9 Gas Cylinder ValveOutlet
7、and Inlet ThreadsNBS Handbook H-282.5 Code of Federal Regulations:6DOT 49 CFR 173DOT 49 CFR 178DOT CFFC 4th Revision2.6 ANSI Standards:7ANSI Y14.5M1994 Dimensioning and Tolerancing3. Connector Gender Assignment3.1 The male connector is that connector which is configured as part of the CO2 control va
8、lve or compressed airgas regulatorfor use with a paintball marker.1 This specification is under the jurisdiction of ASTM Committee F08 on Sports Equipment, Playing Surfaces, and Facilities and is the direct responsibility ofSubcommittee F08.24 on Paintball and Equipment.Current edition approved Apri
9、l 1, 2015April 1, 2016. Published August 2015April 2016. Originally approved in 2007. Last previous edition approved in 20112015 asF2653 11.F2653 11 (2015). DOI: 10.1520/F2653-11R15.10.1520/F2653-16.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service
10、at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 Available from Standardization Documents Order Desk, DODSSP, Bldg. 4, Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098, http:/www.dodssp.daps.mil.4 Avai
11、lable from Compressed Gas Association (CGA), 4221 Walney Rd., 5th Floor, Chantilly, VA 20151-2923, http:/.5 Available from The National Conference on Weights and Measures, 15245 Shady Grove Road, Suite 130, Rockville, MD 20850.6 Available from U.S. Department of Transportation, 400 7th Street, SW, W
12、ashington, D.C. 20590.7 Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http:/www.ansi.org.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to th
13、e previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright A
14、STM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2 The female connector is that connector which is configured as part of the DOT approved cylinder.4. Materials and Manufacture4.1 The male connector shall be made from materials that are compatib
15、le with CO2, compressed air or gaseous nitrogen.4.2 The O-ring seal shall be made from an elastomer compatible with CO2, compressed air or gaseous nitrogen used to powerpaintball markers. The O-ring seal shall have a hardness that will register a Type A durometer reading of between 70 to 90 6 5.The
16、O-ring shall conform dimensionally to the requirements in AMS7277 or MS28775 based upon the size and materialrecommendations of the cylinder manufacturer.4.3 The O-ring seal shall be installed on the male connector in the groove described by Dimensions C and D on Fig. 1.4.4 The male connectors shall
17、 not have any sharp edges or hanging burrs. All sharp edges will be broken R.38 MAX (R.015MAX).4.5 The male connector shall have a gas passage allowing the contents of the bottle to flow at a rate not less than 170 sL/minat 689 kPa (6 S.C.F.M. at 100 psid).4.6 This male connector is most commonly us
18、ed in paintball marker propellant applications in conjunction with SpecificationF1750.5. Performance Requirements5.1 The male threaded connector is intended for use with CO2, compressed air, or gaseous nitrogen, or a combination thereof.5.2 The male threaded connector shall have a straight thread wi
19、th at least the number of engaged threads as shown in Table 1,a tight fit and a factor of safety in shear of at least 10 at the test pressure of the cylinder. The test pressure for a cylinder is specifiedin DOT 49 CFR 178 or DOT CFFC 4th Revision. Shear stress must be calculated by using the appropr
20、iate thread shear area inaccordance with NBS Handbook H-28.Dimension SI InchesA See Table 1 See Table 1B 11.11 min 0.438 minC 2.54 min 0.100 maxD 14.05 min 0.535 minE 5.56 min 0.219 minG R0.7925 min R0.0310 minFIG. 1 Male ConnectorF2653 1625.3 The male threaded connector may incorporate a unified ru
21、pture disk manufactured and tested in accordance with DOT 49CFR 173.301 and CGA S-1.1, as well as meeting Specification F2030. In a case where the male connector does not incorporatea unified rupture disk the cylinder shall contain this device.5.4 When installed in an approved cylinder the male conn
22、ector will require a minimum removal torque of 18 lbfft.5.5 The male threaded connector will be of a design such that if it is removed at a speed of 20 rpm from a fully charged paintballcylinder at SAP, with the cylinder being oriented at a downward angle of 45, the contents of the cylinder will ven
23、t with a resultantg load at impact of the cylinder to a fixed sensor at a distance of 2 ft, of no more than a like full cylinder allowed to drop unaidedthe same distance. All test samples will be as manufactured for sale.6. Physical Envelope6.1 The male connector shall conform to the physical envelo
24、pe described in Fig. 1.6.2 An example of the female connector is described in Fig. 2.FIG. 2 Example of a Female ConnectorTABLE 1 Minimum Valve Thread Requirements by DOT CylinderTypeDOT Cylinder Min. Valve Threads Test Pressure3AL Min. 6 full threads 5/3 Operating PressureFRP Min. 6 full threads 5/3
25、 Operating PressureCFFC 4th Rev. Min. 6 full threads 5/3 Operating Pressure3E Min. 4 full threads 5/3 Operating PressureF2653 1637. Keywords7.1 burst disc; paintball marker; paintball sportsASTM International takes no position respecting the validity of any patent rights asserted in connection with
26、any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technic
27、al committee and must be reviewed every five years andif not revised, either reapproved or withdrawn.Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration
28、at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor
29、 Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the Copyright Clearance Center, 222Rosewood Drive, Danvers, MA 01923, Tel: (978) 646-2600; http:/ 164