ASTM F2750-2008 Standard Test Method for Determining the Effects of Bending a Membrane Switch or Assembly.pdf

上传人:amazingpat195 文档编号:539386 上传时间:2018-12-07 格式:PDF 页数:3 大小:118.41KB
下载 相关 举报
ASTM F2750-2008 Standard Test Method for Determining the Effects of Bending a Membrane Switch or Assembly.pdf_第1页
第1页 / 共3页
ASTM F2750-2008 Standard Test Method for Determining the Effects of Bending a Membrane Switch or Assembly.pdf_第2页
第2页 / 共3页
ASTM F2750-2008 Standard Test Method for Determining the Effects of Bending a Membrane Switch or Assembly.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: F 2750 08Standard Test Method forDetermining the Effects of Bending a Membrane Switch orAssembly1This standard is issued under the fixed designation F 2750; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of l

2、ast revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method establishes a method for the bending ofany part of a membrane switch with conductive circuits.1.1.1 Th

3、e values given in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-pria

4、te safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Terminology2.1 Definitions:2.1.1 bendto force from a straight form into a differentand especially a curved one.2.1.1.1 DiscussionIn this case, no “hard” or angled creaseor fold is to occur. The

5、substrate will only be formed into aradius.2.1.2 bend cyclea bend of a sample around a specifiedmandrel which is “rolled” in one direction, followed by rollingin the opposite direction, returning the sample to its originalposition (see Fig. 1).2.1.3 mandrela cylindrically shaped metal rod, such as a

6、brazing or drill rod.2.1.4 membrane switcha momentary switching device inwhich at least one contact is on, or made of, a flexiblesubstrate.2.1.5 membrane switch taila flexible portion of a mem-brane switch used for input/output connection.3. Significance and Use3.1 Bending of membrane switches or th

7、eir components canaffect their visual appearance, mechanical integrity or electricalfunctionality. This test method simulates conditions that maybe seen during manufacture, installation or use.3.2 Bend testing may be destructive, therefore any samplestested should be considered unfit for future use.

8、3.3 Specific areas of testing include, but are not limited to:3.3.1 Membrane switch flex tails, and3.3.2 Any component of a membrane switch that may besubjected to bending.4. Interferences4.1 The following parameters may affect the results of thistest:4.1.1 temperature,4.1.2 humidity, and4.1.3 orien

9、tation of the conductor (either extension or com-pression) could have significant impact on the results.5. Apparatus5.1 Mandrel, allowed to rotate smoothly around its longitu-dinal axis, rigid, low friction smooth surface. Diameter to bespecified.5.2 Fixture to hold test sample securely in place in

10、a verticalmanner (refer to Fig. 1).5.3 Mechanism capable of providing a consistent force andrate of pull to the sample.5.4 Equipment for the monitoring and recording of resis-tance.6. Test Samples6.1 The test samples may be components, tail assembles orfinished switches. If the sample length is too

11、short for the testfixture, a sample coupon of the same construction (layer tolayer) must be provided (minimum; 250 mm length by 25 mmwidth).6.2 The width of the test sample must not exceed the lengthof the mandrel.7. Procedure7.1 Clamp one end of the test sample to the test fixture thisis the static

12、 end of the test sample.7.1.1 Compression Conductor Testingconductor side ofthe test sample faces the mandrel.7.1.2 Extension Conductor Testingconductor side of thetest sample faces away from the mandrel.1This test method is under the jurisdiction of ASTM Committee F01 onElectronics and is the direc

13、t responsibility of Subcommittee F01.18 on MembraneSwitches.Current edition approved Nov. 1, 2008. Published December 2008.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7.2 Loop the unsecured end of the test sample around themandre

14、l this later becomes the dynamic end of the testsample.7.3 Clamp the unsecured end of the test sample to the liftingmechanism (no tension).7.3.1 Ensure that both ends of the test sample remainparallel during motion of test.7.4 Connect to the test sample so that circuit resistance canbe monitored.NOT

15、E 1Experience has shown that some conductors recover theirconductive properties if allowed to stabilize after the dynamic portion ofthe test. Therefore continuous monitoring is recommended.7.4.1 Verify test sample is functional and being monitored.7.5 Apply the minimum tension load of sufficient mag

16、nitudesuch that the test sample contacts 50 % of the circumferencesurface of the mandrel. (Typically, this is a kg mass providingthe tension load.)7.6 Adjust the test fixture to achieve maximum travel of themandrel by pulling the unsecured end (dynamic end) of the testsample while maintaining 50 % c

17、ontact with the mandrel.7.7 Start test.7.7.1 Record the closed loop resistance (Ri) - measurementmade on the first test cycle. At the end of the test, the “Rmaximum” value, which is the largest value using a timeconstant chosen appropriately for the measurement, is re-corded.7.7.2 A cycle is defined

18、 as travel from maximum extensionto minimum extension and back to maximum extension.7.7.3 The linear speed of the dynamic end of the test sampleshould not exceed 25.4 mm/s.7.8 Repeat cycles until resistance increases by 30 % or moreof Ri for 10 consecutive cycles or the specified number ofcycles are

19、 completed. Resistance is to be continuously moni-tored or measured within3sofcycling. Time between cyclesshall not exceed 3 s.7.9 Remove test sample from test fixture.8. Report8.1 Report the following information:8.1.1 Temperature,8.1.2 Humidity,8.1.3 Resistance measurements, Ri, R maximum,8.1.4 Nu

20、mber of cycles per specimen,8.1.5 Part number or description of specimen,8.1.6 Date of test,8.1.7 Orientation of test sample (compression, extension, orboth),8.1.8 Diameter of mandrel, and8.1.9 Load weight.9. Keywords9.1 bend; mandrel; membrane switch; tail assemblyFIG. 1 Test Fixture SetupF2750082A

21、STM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are

22、entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standard

23、sand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committe

24、e on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).F2750083

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1