1、BRITISH STANDARD BS3041-12: 1981 IEC169-12: 1979 Radio-frequency connectors Part12: Specification for r.f.coaxial connectors with screw coupling, unmatched (type UHF) UDC621.315.683.029.5/.6:621.315.212112.83BS3041-12:1981 This British Standard, having been prepared under the directionof the Electro
2、nic Components Standards Committee, was published underthe authority of the Executive Board and comes intoeffect on 30 September1981 BSI10-1999 The following BSI references relate to the work on this standard: Committee referenceECL/6 Draft for comment80/26695DC ISBN 0 580 12296 4 Cooperating organi
3、zations The Electronic Components Standards Committee, under whose direction this British Standard was prepared, consists of representatives from the following: British Electrical and Allied Manufacturers Association (BEAMA) Department of Industry (Computers, Systems and Electronics) Electricity Sup
4、ply Industry in England and Wales Electronic Components Industry Federation* Electronic Engineering Association* Institution of Electronic and Radio Engineers Ministry of Defence* National Supervising Inspectorate* Society of British Aerospace Companies Limited* Telecommunication Engineering and Man
5、ufacturing Association (TEMA) The organizations marked with an asterisk in the above list, together with the following, were directly represented on the Technical Committee entrusted with the preparation of this British Standard: Association of Manufacturers Allied to the Electrical and Electronic I
6、ndustry(AMA) British Plastics Federation British Telecom United Kingdom Atomic Energy Authority Amendments issued since publication Amd. No. Date of issue CommentsBS3041-12:1981 BSI 10-1999 i Contents Page Cooperating organizations Inside front cover National foreword ii 1 Scope 1 2 IEC type designa
7、tion 1 3 Ratings 1 4 Climatic category 1 5 Dimensions Mating face details 1 6 Gauges 3 7 Survey of patterns 4 8 Outline dimensions 4 9 Schedule for type tests 4 Figure 1 1 Figure 2 2 Figure 2a Dimensional expansion along the circumference at the front of diameter d 2 Figure 2b 2 Figure 3 Gauge pins
8、for centre contact of socket connector 3 Publications referred to Inside back coverBS3041-12:1981 ii BSI 10-1999 National foreword This Part of this British Standard has been prepared under the direction of the Electronic Components Standards Committee. It is identical with IEC Publication169-12 “Ra
9、dio-frequency connectors” Part12 “R.F. coaxial connectors with screw coupling, unmatched (Type UHF)” published in1979 by the International Electrotechnical Commission (IEC). This Part is intended to be read in conjunction with BS3041-1 “Specification for general requirements and measuring methods”.
10、Terminology and conventions. The text of the International Standard has been approved as suitable for publication as a British Standard without deviation. Some terminology and certain conventions are not identical with those used in British Standards; attention is especially drawn to the following.
11、The comma has been used in some places as a decimal marker. In British Standards it is current practice to use a full point on the baseline as the decimal marker. There is no British Standard equivalent for ISO370 which is referred to in clause5 for information purposes only. A related British Stand
12、ard for this ISOstandard is BS2856 “Precise conversion of inch and metric sizes on engineering drawings”. Additional information. For the purposes of this standard clause2 should be read as follows. “2. BS/IEC type designation Connectors conforming to this standard shall be designated by: the refere
13、nce to this standard, BS3041-12169-12 IEC.” Clause6.1.1.2 b) gives the finish of the second steel test pin as0.44m(164in). These values should be understood as the acceptance level for the arithmetic mean deviation (R a ) as specified in BS1134-1. A British Standard does not purport to include all t
14、he necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Cross-references International Standard Corresponding British Standard ISO263:1973 BS1580 Uni
15、fied screw threads Parts1&2:1962 Diameters! in and larger Part3:1965 Diameters below! in (Technically equivalent) Summary of pages This document comprises a front cover, an inside front cover, pagesi andii, pages1 to4, an inside back cover and a back cover. This standard has been updated (see copyri
16、ght date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS3041-12:1981 BSI 10-1999 1 1 Scope This standard gives the mating face dimensions for an r.f. coaxial connector known commercially as the UHF connector. 2 IEC type designatio
17、n 1) Connectors conforming to this standard shall be designated by: the reference to this standard:169-12 IEC. 3 Ratings The r.f. connectors defined in this standard are not matched and no specification for reflection factor is given. Voltage: Current:10 A maximum. 4 Climatic category 5 Dimensions M
18、ating face details Inch dimensions are original dimensions. The millimetre dimensions are derived from original inch dimensions according to ISO Standard370 5.1 Connector with pin centre contact 1) See national foreword. Application Sea level Working (d.c. or a.c. peak) Proof 750V 2kV Category Tempe
19、rature range 25/70 Damp heat test notapplicable 25 C to+70 C Figure 1 BS3041-12:1981 2 BSI 10-1999 5.2 Connector with socket centre contact Ref. mm in Remarks Note Figure Min. Max. Min. Max. a 11,56 12,22 0,455 0,481 Diam. 5 Figure 1 b 5/824 UNEF2B 1 Figure 1 c d g j k l m r s u v w x y 16,00 13,92
20、0,00 1,19 8,76 3,912 0,38 0,6 1,3 4,27 9,91 11,10 3,35 4,013 0,89 0,64 0,89 0,75 1,55 0,630 0,548 0,000 0,047 0,345 0,154 0,015 0,0236 0,0512 0,168 0,390 0,437 0,132 0,158 0,035 0,025 0,035 0,0295 0,0610 Diam. Diam. Diam. Diam. Rad. 4/8 4/8 8 8 8 Figure 1 Figure 1 Figure 1 Figure 1 Figure 1 Figure 1
21、 Figure 1 Figure 1 Figure 1 Figure 1a Figure 1a Figure 1b Figure 1b Figure 1b NOTE 1Screw thread according to ISO Standard263. NOTE 2Mechanical and electrical reference plane. NOTE 3Form of inner conductor tip is optional. NOTE 4Shape of front end of the lug is optional. NOTE 5Entry chamfer up to12.
22、57mm(0.495in) diameter permissible on this dimension. NOTE 8Figure 1a and Figure 1b define alternative forms of lugs. Figure 2 Figure 2a Dimensional expansion alongthecircumference at the frontofdiameter d Figure 2b BS3041-12:1981 BSI 10-1999 3 6 Gauges 6.1 Mechanical gauges 6.1.1 Socket connector 6
23、.1.1.1 Centre contact Ref. mm in Remarks Note Figure Min. Max. Min. Max. a 11,56 12,22 0,455 0,481 Diam. Figure 2 b 5/824 UNEF2A 1 Figure 2 d e f g k l m n p q s v w x y 14,00 1,19 1,02 0,03 7,87 11,10 11,76 4,039 0 0,89 0,41 1,04 14,25 1,96 0,64 Z 0,6 1,3 0,551 0,047 0,040 0,001 0,310 0,437 0,463 0
24、,159 0 0,035 0,016 0,041 0,561 0,077 0,025 Z 0,024 0,051 Diam. Rad. Diam. Rad. 2/6 2/6 7/6 5 Figure 2 Figure 2 Figure 2 Figure 2 Figure 2 Figure 2 Figure 2b Figure 2b Figure 2a Figure 2b Figure 2b Figure 2a Figure 2a Figure 2a Figure 2a NOTE 1Screw thread according to ISO Standard263. NOTE 2Method o
25、f slotting and number of slots optional. NOTE 3Mechanical and electrical reference plane. NOTE 4Chamfer to achieve insertion of pin contact. NOTE 5Position of centre of radius v is not specified. It depends on the other dimensional conditions. NOTE 6To meet the requirements of Sub-clause6.1.1.2. NOT
26、E 7Before slotting and closing. Figure 3 Gauge pins for centre contact of socket connectorBS3041-12:1981 4 BSI 10-1999 6.1.1.2 Test sequence a) A steel test pin (Figure 3) with a diameter a ofmm(in) shall be inserted once into the centre contact a minimum distance of11mm(0.433in). b) A second steel
27、test pin (Figure 3) with a diameter a of3.912 0.005mm(0.1540 0.0002in) and a0.44m(164in) finish shall have a withdrawal force of1.1N minimum/6.8N maximum after insertion into the centre contact 2) . It is recommended that this gauge should have a mass (weight) of112g, which must be held by the socke
28、t contact. 7 Survey of patterns No particular patterns for this type of connector are standardized for the time being. 8 Outline dimensions No dimensions are standardized for the time being. 9 Schedule for type tests All connectors shall be subjected to the following test sequence: 2) See national f
29、oreword. Test Clause or sub-clause of IEC Publication169-1 Conditions of test Requirements Visual inspection Dimensions Gauge retention force Contact resistance Insulation resistance Temperature Repeat insulation resistance 12 13 15.2.3 14.3.2 14.5 16.2.3 16.2.1 14.5 To be tested in accordance with
30、Sub-clauses6.1.1.1 and6.1.1.2 For inner contacts (matedset) For outer contacts (matedset) 25 C low +70 C high Shall conform to the requirements specified Shall conform to the requirements specified in Clause5 of this standard 5.0m7 max. 5.0m7 max. 5G7 min. 5G7 min. 4.016 +0.005 0 0.1581 +0.0002 0BS3
31、041-12:1981 BSI 10-1999 Publications referred to See national foreword.BS3041-12: 1981 IEC169-12: 1979 BSI 389 Chiswick High Road London W4 4AL BSIBritishStandardsInstitution BSI is the independent national body responsible for preparing BritishStandards. It presents the UK view on standards in Euro
32、pe and at the international level. It is incorporated by Royal Charter. Revisions BritishStandards are updated by amendment or revision. Users of BritishStandards should make sure that they possess the latest amendments or editions. It is the constant aim of BSI to improve the quality of our product
33、s and services. We would be grateful if anyone finding an inaccuracy or ambiguity while using this BritishStandard would inform the Secretary of the technical committee responsible, the identity of which can be found on the inside front cover. Tel:02089969000. Fax:02089967400. BSI offers members an
34、individual updating service called PLUS which ensures that subscribers automatically receive the latest editions of standards. Buying standards Orders for all BSI, international and foreign standards publications should be addressed to Customer Services. Tel:02089969001. Fax:02089967001. In response
35、 to orders for international standards, it is BSI policy to supply the BSI implementation of those that have been published as BritishStandards, unless otherwise requested. Information on standards BSI provides a wide range of information on national, European and international standards through its
36、 Library and its Technical Help to Exporters Service. Various BSI electronic information services are also available which give details on all its products and services. Contact the Information Centre. Tel:02089967111. Fax:02089967048. Subscribing members of BSI are kept up to date with standards de
37、velopments and receive substantial discounts on the purchase price of standards. For details of these and other benefits contact Membership Administration. Tel:02089967002. Fax:02089967001. Copyright Copyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of the publicat
38、ions of the international standardization bodies. Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means electronic, photocopying, recording or otherwise without prior written permiss
39、ion from BSI. This does not preclude the free use, in the course of implementing the standard, of necessary details such as symbols, and size, type or grade designations. If these details are to be used for any other purpose than implementation then the prior written permission of BSI must be obtained. If permission is granted, the terms may include royalty payments or a licensing agreement. Details and advice can be obtained from the Copyright Manager. Tel:02089967070.