1、BRITISH STANDARD BS 469:1995 Incorporating Corrigendum No. 1 Specification for Railway signalling lamps ICS 29.140.99; 45.040 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBS 469:1995 This British Standard, having been prepared under the direction of the Electrotechnical Sect

2、or Board, was published under the authority of the Standards Board and comes into effect on 15 July 1995 BSI 18 January 2002 First published October 1932 Second edition January 1939 Third edition September 1952 Fourth edition December 1960 Fifth edition July 1995 The following BSI references relate

3、to the work on this standard: Committee reference CPL/34/1 Draft for comment 92/28352 DC ISBN 0 580 24250 1 Committees responsible for this British Standard The preparation of this British Standard was entrusted to Technical Committee CPL/34/1, Electric lamps, upon which the following bodies were re

4、presented: British Lighting Association for the Preparation of Standards (BRITLAPS) Chartered Institution of Building Services Engineers Consumer Policy Committee of BSI Electricity Association Engineering Equipment and Materials Users Association Institution of Lighting Engineers Lighting Industry

5、Federation Ltd. London Regional Transport Society of Motor Manufacturers and Traders Ltd. The following body was also represented in the drafting of the standard, through sub-committee CPL/34/1/9: British Railways Board Amendments issued since publication Amd. No. Date Comments 13457 Corr. No. 1 18

6、January 2002 Indicated by a sidelineBS 469:1995 BSI 18 January 2002 i Contents Page Committees responsible Inside front cover Foreword ii Section 1. General 1S c o p e 1 2 Normative references 1 3 Definitions 1 4 Requirements 2 Annex A (normative) Testing 14 Annex B (informative) Statistical basis o

7、f the test quantities and the acceptable non-conformity levels given in Annex A 17 Figure 1 Holder for torsion test for B.22 (3-pin) caps 3 Figure 2 Holder for torsion test for B.15 caps 4 Table A.1 Acceptable non-conformity level for mechanical and physical requirements 15 Table A.2 Acceptable non-

8、conformity level for lamps of an RTQ which are found to be inoperative at any time up to the end of the ageing period (see A.2.3)1 6 Table A.3 Acceptable non-conformity level for lamps with wattage above the specified maximum values 16 Table A.4 Acceptable non-conformity level for lamps with lumen v

9、alues below the specified minimum values 16 Table A.5 Acceptable non-conformity level for lamps with lumen values below the specified minimum values and wattage above the specified maximum values 16 Table A.6 Allowance for the average life of filaments, main filaments and auxiliary filaments of lamp

10、s in an LTQ 17 Table A.7 Acceptable non-conformity level for lamps in an LTQ in which the filament, main filament and auxiliary filament has a life shorter than 60 % of the specified life 17 Section 2. Standard data sheets for railway signalling lamps 5 List of references 18BS 469:1995 ii BSI 18 Jan

11、uary 2002 Foreword This British Standard has been prepared by Technical Committee CPL/34/1 and it supersedes BS 469:1960 which is withdrawn. This revision has taken the opportunity of changing the presentation of the information to reflect current international practice by the introduction of lamp d

12、ata sheets in Section 2, and of updating cross-references and drawings. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer im

13、munity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 18, an inside back cover and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. Sidelining in this docu

14、ment indicates the most recent changes by amendment.BS 469:1995 BSI 18 January 2002 1 Section 1. General 1 1 Scope This British Standard specifies the requirements for railway signalling lamps and gives the testing procedures required to establish conformity to the requirements, based upon statistic

15、al evaluation against an acceptable non-conformity level. 2 Normative references This British Standard incorporates, by reference, provisions from specific editions of other publications. These normative references are cited at the appropriate points in the text and the publications are listed on pa

16、ge 18. Subsequent amendments to, or revisions of, any of these publications apply to this British Standard only when incorporated in it by updating or revision. 3 Definitions For the purposes of this British Standard the following definitions apply. 3.1 rated value the value specified in the relevan

17、t lamp standard or assigned by the manufacturer or responsible supplier 3.2 double-pole lamp a double-filament lamp in which both filaments are connected permanently in parallel 3.3 triple-pole lamp a double-filament lamp in which one end of each filament is connected to the cap shell and the other

18、ends of the filaments are connected one to each contact plate 3.4 light centre the geometrical centre of the incandescent part of a filament (main or auxiliary) or, in the case of bow filaments, the centre of the enclosing rectangle 3.5 reference plane a plane defined with reference to the cap or ba

19、se and with respect to which the position of certain parts of the lamp are measured 3.6 reference axis an axis defined with reference to the cap or base and with respect to which the position of certain parts of the lamp are measured 3.7 light centre length the distance between the centre of the rec

20、tangle enclosing the luminous filament section or a defined point of the filament and the reference plane 3.8 axial error (lateral deviation) in lamps other than those with offset filaments, the perpendicular distance of the light centre from the axis of the cap 3.9 initial readings the photometric

21、and electrical values measured at the end of the ageing period 3.10 life the total time for which a lamp has been operated before it becomes useless, or, according to specific criteria, is considered to be soBS 469:1995 2 BSI 18 January 2002 Section 1 3.11 batch all the lamps of a single type manufa

22、ctured by a single manufacturer, within the same production time frame and under environmental and production conditions which can be considered to be uniform 3.12 inspection test quantity (ITQ) the sample of lamps required to be inspected for conformity to mechanical and physical requirements 3.13

23、rating test quantity (RTQ) the sample of lamps required to be tested for electrical and photometric values 3.14 life test quantity (LTQ) the sample of lamps required to be tested for conformity to the life requirement 3.15 reference number an identification number defining a type of lamp, with regar

24、d to the particular requirements of this specification 4 Requirements 4.1 General Lamps shall be so designed and constructed that in normal use they present no danger to the user or their surroundings. 4.2 Marking The following information shall be marked on the lamps, and shall remain legible when

25、tested in accordance with A.2.2: a) reference number; b) rated voltage; c) rated wattage; d) trade name or mark of the manufacturer or responsible vendor; e) month and year of manufacture 1) ; f) where specified on the lamp data sheet, the letter “M” shall also appear on the lamp cap adjacent to the

26、 main filament contact plate. Any additional marking shall be such as to allow no confusion with these markings. Where, on some types of lamps, limited space is available for marking, the reference number and month and year of manufacture shall appear on the immediate lamp wrapping or container. 4.3

27、 Dimensions and filament arrangements The dimensions and filament arrangements shall be as specified in the respective lamp data sheets (see Section 2). 4.4 Caps Where applicable, the dimensions of caps of finished lamps shall conform to BS EN 60061-1 or BS 1050. The shell of bayonet caps shall be o

28、f brass or nickel plated brass. Caps shall be so constructed and attached to the bulbs that during the inspection test and on completion of the life test they shall withstand a torsion of either 2.8 Nm in the case of B22 (3-pin) caps, or 1.1 Nm in the case of B15 caps, in both cases when these torsi

29、ons are applied using the holders shown in Figure 1 and Figure 2 respectively. 1) It is permissible to use an abbreviated code.BS 469:1995 BSI 18 January 2002 3 Section 1 4.5 Insulation resistance Except in the case of the triple-pole lamps, the insulation resistance between the contact plates and t

30、he shell of the cap shall be not less than 50 M in the case of B22 (3-pin) caps and 10 M in the case of B15 caps. 4.6 Cap solder The cap solder shall be applied in such quantity as to allow proper engagement of the cap in the lampholder. Contact plates shall be evenly soldered to ensure satisfactory

31、 electrical contact in the appropriate lampholder. If hard solder is used, it shall have a softening point in excess of 290 C. NOTE 1 The use of hard solder should be by agreement between the manufacturer or responsible vendor and the user. NOTE 2 It is not essential that the surface of the contact

32、plate should be completely covered with solder. 4.7 Initial readings The electrical and photometric ratings shall conform to the values given on the relevant data sheets (see Section 2). 4.8 Life The life shall conform to the values given on the relevant data sheets (see Section 2). Dimensions in mi

33、llimetres To be case hardened Dimensions to be within 0.33 mm unless otherwise stated Figure 1 Holder for torsion test for B.22 (3-pin) capsBS 469:1995 4 BSI 18 January 2002 Section 1 Dimensions in millimetres To be case hardened Dimensions to be within 0.33 mm unless otherwise stated Figure 2 Holde

34、r for torsion test for B.15 capsBS 469:1995 BSI 18 January 2002 5 Section 2. Standard data sheets for railway signalling lamps 5 Data sheet Reference number Use BS-469-01 BS-469-02 BS-469-03 BS-469-04 BS-469-03 BS-469-03 BS-469-05 BS-469-01 BS-469-06 BS-469-05 BS-469-07 BS-469-08 BS-469-08 SL 5 SL 1

35、3 SL 17 SL 18 SL 21 SL 22 SL 25 SL 29 SL 30 SL 32 SL 33 SL 34 SL 35 Repeaters and indicators Searchlight signals Multi-aspect colour-light signals Multi-aspect colour-light signals Multi-aspect colour-light signals Position light junction indicators Searchlight signals Repeaters and indicators Illum

36、inated diagrams and control panels Searchlight signals Position light junction indicators Multi-aspect colour-light signals Multi-aspect colour-light signalsBS 469:1995 6 BSI 18 January 2002 Railway signalling filament lamp SL 5, SL 29 SL code number Rated voltage Life test voltage Filament values R

37、ated wattage Maximum awattage Minimum aluminous flux Specified life Filament shape VVWW lm h S L 5 1 2 . 01 5 . 04 . 0 4 . 4 2 1 1 0 0 A n y SL 29 12.0 12.0 2.4 2.7 12 500 Any a Initial values The lamp drawings are intended only to indicate the dimensions to be checked Cap BA15d BS EN 60061-1 Sheet

38、7004-11A Dimensions Maximum Minimum mm mm C 35.0 30.0 D 19.0 17.0 Operating position: horizontal BS-469-01BS 469:1995 BSI 18 January 2002 7 Railway signalling filament lampSL 13 SL code number Rated voltage Life test voltage Filament values Rated wattage Maximum awattage Minimum aluminous flux Speci

39、fied life Filament shape VVWWl mh SL 13 6.0 6.0 12.0 13.0 108 1 000 Bow a Initial values The lamp drawings are intended only to indicate the dimensions to be checked Cap BA15s BS EN 60061-1 Sheet 7004-11A-8 Dimensions Maximum Minimum mm mm C 60 52 D 40 36 e 32.5 31.5 Lateral deviation 0.5 Operating

40、position: horizontal BS-469-02BS 469:1995 8 BSI 18 January 2002 Railway signalling filament lamp Double-pole SL 17, SL 21, SL 22 SL code number Filament Rating Life test Total values for main and auxiliary filaments in parallel Main Auxiliary Rated wattage Maximum awattage Minimum aluminous flux Spe

41、cified life VWVWV W W l m h SL 17 12 16 16 12 12.0 25.0 27.1 142 1 000 SL 21 12 24 16 12 12.0 33.0 35.7 218 1 000 SL 22 12 10 16 6 12.0 14.0 15.2 68 1 000 a Initial values The lamp drawings are intended only to indicate the dimensions to be checked Cap B22d-3 (90 /135 ) 25 25 BS EN 60061-1 Sheet 700

42、4-10A-2 Dimensions Maximum mm Minimum mm C 83 73 D 52 48 e 42.5 41.5 Z 3.5 2.5 Operating position: vertical cap down BS-469-03BS 469:1995 BSI 18 January 2002 9 Railway signalling filament lamp SL 18 SL code number Rated voltage Life test voltage Main filament Rated wattage Maximum awattage Minimum a

43、luminous flux Specified life Filament shape VVWW lm h SL 18 12.0 12.0 24.0 26.0 260 1 000 Transverse a Initial values The lamp drawings are intended only to indicate the dimensions to be checked Cap B22d-3 (90 /135 ) 25 26 BS EN 60061-1 Sheet 7004-10A-2 Dimensions Maximum mm Minimum mm C 83 73 D 52

44、48 e 42.5 41.5 Z 3.5 2.5 Lateral deviation 0.5 Operating position: vertical cap down BS-469-04BS 469:1995 10 BSI 18 January 2002 Section 2 Railway signalling filament lamp Triple-pole SL 32, SL 25 SL code number Rated voltage Life test voltage Main filament values Auxiliary filament values Rated wat

45、tage Maximum awattage Minimum aluminous flux Specified life Filament shape Rated wattage Maximum awattage Minimum aluminous flux Specified life VVWWl mh WW lm h SL 32 12.0 12.0 12.0 13.0 99 1 000 Bow 16.0 17.3 166 250 SL 25 6.0 6.0 6.0 6.5 34.5 1 000 Bow 9.0 9.7 72 250 a Initial values The lamp draw

46、ings are intended only to indicate the dimensions to be checked Cap B15d BS EN 60061-1 Sheet 7004-11A-8 Dimensions Maximum mm Minimum mm C 60 52 D 40 36 e ab 32.5 31.5 U2 . 4 V4 . 8 Lateral deviation 0.5 X 31 ab Main filaments only Operating position: horizontal BS-469-05BS 469:1995 BSI 18 January 2

47、002 11 Section 2 Railway signalling filament lamp SL 30 SL code number Cap type Rated voltage Life test voltage Main filament values Rated wattage Maximum awattage Minimum aluminous flux Specified life VVWWl mh SL 30 Red end piece 12.0 14.0 1.2 1.35 2.4 1 000 a Initial values For filament arrangemen

48、ts and dimensions see BS 1050 Operating position: horizontal BS-469-06BS 469:1995 12 BSI 18 January 2002 Section 2 Railway signalling filament lamp SL 33 SL code number Rated voltage Life test voltage Main filament values Rated wattage Maximum awattage Minimum aluminous flux Specified life Filament

49、shape V V WWl mh SL 33 110.0 110.0 25.0 27.1 122 1 000 Any a Initial values The lamp drawings are intended only to indicate the dimensions to be checked Cap B22d-3 (90 /135 ) 25 26 BS EN 60061-1 Sheet 7004-10A-2 Dimensions Maximum mm Minimum mm C 83 73 D 52 48 e 42.5 41.5 Lateral deviation 0.5 2.5 Operating position: vertical cap down BS-469-07BS 469:1995 BSI 18 January 2002 13 Section 2 Railway signalling filament lamp Triple-pole SL 34, SL 35 SL code number Rated voltage Life test voltage Main filament values Auxiliary f

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1