BS 6068-2 7-1984 Water quality - Physical chemical and biochemical methods - Determination of ammonium distillation and titration method《水质 第2部分 物理、化学和生物化学方法 第7节 铵含量测定 蒸馏和滴定法》.pdf

上传人:explodesoak291 文档编号:545664 上传时间:2018-12-09 格式:PDF 页数:8 大小:359.41KB
下载 相关 举报
BS 6068-2 7-1984 Water quality - Physical chemical and biochemical methods - Determination of ammonium distillation and titration method《水质 第2部分 物理、化学和生物化学方法 第7节 铵含量测定 蒸馏和滴定法》.pdf_第1页
第1页 / 共8页
BS 6068-2 7-1984 Water quality - Physical chemical and biochemical methods - Determination of ammonium distillation and titration method《水质 第2部分 物理、化学和生物化学方法 第7节 铵含量测定 蒸馏和滴定法》.pdf_第2页
第2页 / 共8页
BS 6068-2 7-1984 Water quality - Physical chemical and biochemical methods - Determination of ammonium distillation and titration method《水质 第2部分 物理、化学和生物化学方法 第7节 铵含量测定 蒸馏和滴定法》.pdf_第3页
第3页 / 共8页
BS 6068-2 7-1984 Water quality - Physical chemical and biochemical methods - Determination of ammonium distillation and titration method《水质 第2部分 物理、化学和生物化学方法 第7节 铵含量测定 蒸馏和滴定法》.pdf_第4页
第4页 / 共8页
BS 6068-2 7-1984 Water quality - Physical chemical and biochemical methods - Determination of ammonium distillation and titration method《水质 第2部分 物理、化学和生物化学方法 第7节 铵含量测定 蒸馏和滴定法》.pdf_第5页
第5页 / 共8页
亲,该文档总共8页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、BRITISH STANDARD BS 6068-2.7: 1984 ISO 5664:1984 Water quality Part 2: Physical, chemical and biochemical methods Section 2.7 Determination of ammonium: distillation and titration method ISO title: Water quality Determination of ammonium Distillation and titration method UDC 556:614.777:628.1/.3:663

2、.63:543.24:546.171.1BS6068-2.7:1984 This British Standard, having been prepared under the directionof the Environment andPollution Standards Committee, was published underthe authority of the BoardofBSI and comes into effect on 31 December 1984 BSI 10-1999 The following BSI references relate to the

3、work on this standard: Committee reference EPC/44 Draft for comment 83/50174 DC ISBN 0 580 14197 7 Amendments issued since publication Amd. No. Date of issue CommentsBS6068-2.7:1984 BSI 10-1999 i Contents Page National foreword ii 1 Scope 1 2 Field of application 1 3 Principle 1 4 Reagents 1 5 Appar

4、atus 2 6 Sampling and samples 2 7 Procedure 2 8 Expression of results 2 9 Test report 3 Table 1 2 Table 2 3 Table 3 3BS6068-2.7:1984 ii BSI 10-1999 National foreword This Section of this British Standard, which has been prepared under the direction of the Environment and Pollution Standards Committe

5、e, is identical with ISO5664:1984 “Water quality Determination of ammonium Distillation and titration method”. The International Standard was prepared by subcommittee2, Physical, chemical and biochemical methods, of Technical Committee147, Water quality, of the International Organization for Standar

6、dization (ISO) as a result of discussion in which the UK participated. This British Standard is being published in a series of Parts subdivided into Sections that will generally correspond to particular International Standards. Sections are being, or will be, published in Parts 1 to 6 which, togethe

7、r with Part0, are as follows. Part 0: Introduction; Part 1: Glossary; Part 2: Physical, chemical and biochemical methods; Part 3: Radiological methods; Part 4: Microbiological methods; Part 5: Biological methods; Part 6: Sampling. Terminology and conventions. The text of the International Standard h

8、as been approved as suitable for publication as a British Standard without deviation. Some terminology and certain conventions are not identical with those used in British Standards; attention is drawn especially to the following. The comma has been used as a decimal marker. In British Standards it

9、is current practice to use a full point on the baseline as the decimal marker. Wherever the words “International Standard” appear, referring to this standard, they should be read as “British Standard”. It is current practice in British Standards for the symbol “L” to be used for litre rather than “l

10、” and for the term “sulphur” to be used rather than “sulfur”. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity fro

11、m legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages1to3 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside fr

12、ont cover.BS6068-2.7:1984 BSI 10-1999 1 1 Scope This International Standard specifies a distillation and titration method for the determination of ammonium in raw, potable and waste water. 2 Field of application 2.1 Range An ammonium nitrogen content of up to10mg in the test portion may be determine

13、d. Using a10ml test portion, this corresponds to a sample concentration of up to A P N= 1000mg/l. 2.2 Limit of detection A practically determined (4degrees of freedom) limit of detection, using a250ml test portion, is cvA N= 0,2mg/l. 2.3 Sensitivity Using a100ml test portion1,0ml of0,02mol/l hydroch

14、loric acid is equivalent to A N= 2,8mg/l. 2.4 Interferences The main possible interference arises from urea which, under the conditions specified, will distil as ammonia thus causing high results. Interference will also arise from volatile amines which will distil and react with the acid during the

15、titration, thus causing high results. Chloramines present in chlorinated water samples will be determined in this manner. 3 Principle Adjustment of the pH of a test portion to within the range6,0to7,4. Addition of magnesium oxide to produce mildly alkaline conditions, distillation of the liberated a

16、mmonia and collection in a receiving flask containing boric acid solution. Titration of the ammonium in the distillate with standard volumetric acid solution using boric acid/indicator solution. 4 Reagents During the analysis, use only reagents of recognized analytical grade and only water prepared

17、as described in 4.1. 4.1 Water, ammonium-free, prepared by one of the following methods. 4.1.1 Ion exchange method Pass distilled water through a column of strongly acidic cation-exchange resin (in the hydrogen form) and collect the eluate in a glass bottle provided with a well-fitting glass stopper

18、. Add about10g of the same resin to each litre of eluate for storage purposes. 4.1.2 Distillation method Add0,10 0,01ml of sulfuric acid solution(A = 1,84g/ml) to 1000 10ml of distilled water and redistil in an all glass apparatus. Discard the first50ml of distillate, and then collect the distillate

19、 in a glass bottle provided with a well-fitting glass stopper. Add about10g of strongly acidic, cation exchange resin (in the hydrogen form), to each litre of collected distillate. 4.2 Hydrochloric acid, A = 1,18g/ml. 4.3 Hydrochloric acid, standard volumetric solution, c(HCl) = 0,10mol/l. Prepare t

20、his solution by diluting the hydrochloric acid (4.2). Standardize it by normal analytical procedures. Alternatively, commercial solutions of guaranteed concentration may be used. 4.4 Hydrochloric acid, standard volumetric solution, c(HCl) = 0,02mol/l. Prepare this solution by diluting the hydrochlor

21、ic acid (4.2). Standardize it by normal analytical procedures. Alternatively, commercial solutions of guaranteed concentration, or a diluted solution of the standard volumetric hydrochloric acid (4.3), may be used. 4.5 Boric acid/indicator, solution. 4.5.1 Dissolve0,5 0,1g of water-soluble methyl re

22、d in about800ml of water and dilute to1litre. 4.5.2 Dissolve1,5 0,1g of methylene blue in about800ml of water and dilute to1litre. 4.5.3 Dissolve20 1g of boric acid (H 3 BO 3 ) in warm water. Cool to room temperature. Add10 0,5ml of the methyl red indicator solution(4.5.1) and2,0 0,1ml of the methyl

23、ene blue solution (4.5.2) and dilute to1litre. 4.6 Bromothymol blue, 0,5g/l indicator solution. Dissolve0,5 0,02g of bromothymol blue in water and dilute to 1litre. 4.7 Hydrochloric acid, 1% (V/V) solution. Dilute10 1ml of the hydrochloric acid (4.2) to1litre with water. 4.8 Sodium hydroxide solutio

24、n, 1 mol/l Dissolve40 2g of sodium hydroxide in about500ml of water. Cool to room temperature and dilute to 1 litre. 4.9 Light magnesium oxide, carbonate-free. Heat the magnesium oxide at500 C to remove carbonate. 4.10 Anti-bumping granules 4.11 Anti-foaming agent, for example paraffin wax chips.BS6

25、068-2.7:1984 2 BSI 10-1999 5 Apparatus Ordinary laboratory apparatus, and Distillation apparatus, incorporating a distillation flask of capacity800 to1000ml attached to an anti-splash head and a vertical condenser arranged so that the outlet can be immersed in absorbent solution. NOTE ON PRELIMINARY

26、 CLEANING OF THE DISTILLATION APPARATUS Carry out this procedure whenever the apparatus has been out of use for more than a few days. Place about350ml of the ammonium-free water(4.1) in the distillation flask. Add a few anti-bumping granules (4.10), assemble the apparatus, and distil until at least1

27、00ml of the water has been collected. Discard the distillate and the residue in the distillation flask. 6 Sampling and samples Laboratory samples shall be collected in polyethylene or glass bottles. They should be analysed as quickly as possible, or else stored at between 2and5 C until analysed. Aci

28、dification with sulfuric acid to pH2may also be used as an aid to preservation, provided that possible contamination of the acidified sample by absorption of any atmospheric ammonia is avoided. 7 Procedure 7.1 Selection of volume of test portion If the approximate ammonium content of the sample is k

29、nown, select the volume of the test portion according to Table 1. Table 1 7.2 Determination 7.2.1 Transfer50 5ml of the boric acid/indicator solution (4.5) into the receiving flask of the distillation apparatus. Ensure that the delivery tip of the condenser is below the surface of the boric acid sol

30、ution. Measure the selected volume of test portion (see 7.1) into the distillation flask. NOTEIf chlorine is present in the test portion, a few small crystals of sodium thiosulfate should be added in order to remove it. Add a few drops of the bromothymol blue indicator solution (4.6) and, if necessa

31、ry, adjust the pH to within the range6,0 (indicator yellow) to7,4 (indicator blue) using the sodium hydroxide solution(4.8) or the hydrochloric acid (4.7), as appropriate. Then make up the total volume in distillation flask to about 350ml with the ammonium-free water(4.1). Add to the distillation fl

32、ask0,25 0,05g of the light magnesium oxide (4.9) and a few anti-bumping granules (4.10). The addition of anti-foaming agent(4.11) may be necessary with some waste water samples. Immediately attach the distillation flask to the apparatus. 7.2.2 Heat the distillation flask so that distillate collects

33、at a rate of about10ml/min. Stop the distillation when about200ml have been collected. 7.2.3 Titrate the distillate to the purple end-point using the standard volumetric hydrochloric acid(4.4) and record the volume used. NOTE 1The standard volumetric hydrochloric acid (4.3) may be used for titration

34、 of distillates from samples having high ammonium contents. NOTE 2Ammonia can be titrated as it distils into the receiving flask. If protracted collection of ammonia is thus revealed, it may indicate the presence of interfering substances which are undergoing slow hydrolysis to yield ammonia. 7.3 Bl

35、ank test Carry out a blank test by proceeding as described in7.2, but replacing the test portion with about250ml of the ammonium-free water (4.1). 8 Expression of results 8.1 Method of calculation The ammonium nitrogen concentration, A N , expressed in milligrams per litre, is given by the equation

36、where V 0 is the volume, in millilitres, of the test portion (see 7.1); V 1 is the volume, in millilitres, of the standard volumetric hydrochloric acid used for titration; V 2 is the volume, in millilitres, of the standard volumetric hydrochloric acid used for the titration in the blank test (see7.3

37、); c is the exact concentration, in moles per litre, of the hydrochloric acid used for the titration; 14,01is the atomic mass, in grams per mole, of nitrogen. Ammoniumconcentration, A N Volume of the test portion a mg/l ml up to 10 10 to20 20 to50 50 to 100 250 100 50 25 a When using the standard vo

38、lumetric hydrochloric acid (4.3) for the titration. N V 1 V 2 V 0 -c 1401 , 1 000 =BS6068-2.7:1984 BSI 10-1999 3 The result may be expressed as the mass concentration of nitrogen, A N , ammonia, , or ammonium ion, , in milligrams per litre, or as the amount of substance concentration of ammonium ion

39、, in micromoles per litre. The appropriate conversion factors are given in Table 2. Table 2 Example: An ammonium ion concentration, of 1 mg/l corresponds to a nitrogen concentration of0,777mg/l. 8.2 Reproducibility Reproducibility standard deviations have been determined as indicated in Table 3. 9 T

40、est report The test report shall include the following information: a) reference to this International Standard; b) all details required for the complete identification of the sample; c) details concerning the storage and preservation of the laboratory sample before analysis; d) a statement of the r

41、epeatability achieved by the laboratory when using this method; e) the result and the method of expression used; f) details of any deviation from the procedure specified in this International Standard or any other circumstance that may have influenced the result. Table 3 a A N mg/l mg/l mg/l 4mol/l

42、A N= 1 mg/l 1 1,216 1,288 71,4 = 1 mg/l 0,823 1 1,059 58,7 = 1 mg/l 0,777 0,944 1 55,4 = 1 4mol/l 0,014 0,017 0,018 1 NH 3 NH + 4 c(NH + 4) NH 3 NH + 4 c(NH + 4) NH 3 NH + 4 c(NH + 4) NH + 4 Sample Ammonium content, A N Volume of test portion Standard deviation Degrees of freedom mg/l ml mg/l Standa

43、rd solution 4,0 250 0,23 10 Standard solution 40 250 0,56 11 Settled sewage 35 100 0,70 16 Sewage effluent 1,8 25 0,16 11 a Information from the United Kingdom.BS 6068-2.7: 1984 ISO 5664:1984 BSI 389 Chiswick High Road London W4 4AL BSIBritishStandardsInstitution BSI is the independent national body

44、 responsible for preparing BritishStandards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter. Revisions BritishStandards are updated by amendment or revision. Users of BritishStandards should make sure that they possess the latest am

45、endments or editions. It is the constant aim of BSI to improve the quality of our products and services. We would be grateful if anyone finding an inaccuracy or ambiguity while using this BritishStandard would inform the Secretary of the technical committee responsible, the identity of which can be

46、found on the inside front cover. Tel:02089969000. Fax:02089967400. BSI offers members an individual updating service called PLUS which ensures that subscribers automatically receive the latest editions of standards. Buying standards Orders for all BSI, international and foreign standards publication

47、s should be addressed to Customer Services. Tel:02089969001. Fax:02089967001. In response to orders for international standards, it is BSI policy to supply the BSI implementation of those that have been published as BritishStandards, unless otherwise requested. Information on standards BSI provides

48、a wide range of information on national, European and international standards through its Library and its Technical Help to Exporters Service. Various BSI electronic information services are also available which give details on all its products and services. Contact the Information Centre. Tel:02089

49、967111. Fax:02089967048. Subscribing members of BSI are kept up to date with standards developments and receive substantial discounts on the purchase price of standards. For details of these and other benefits contact Membership Administration. Tel:02089967002. Fax:02089967001. Copyright Copyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of the publications of the internationalstandardization bodies. Except as permitted under the Copyright, Design

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1