BS EN 1074-6-2008 Valves for water nsupply — Fitness for npurpose requirements nand appropriate nverification tests nPart 6 Hydrants《供水用阀门 目的要求和适当检定试验的合理性 消防栓》.pdf

上传人:刘芸 文档编号:548577 上传时间:2018-12-09 格式:PDF 页数:24 大小:1.20MB
下载 相关 举报
BS EN 1074-6-2008 Valves for water nsupply — Fitness for npurpose requirements nand appropriate nverification tests nPart 6 Hydrants《供水用阀门 目的要求和适当检定试验的合理性 消防栓》.pdf_第1页
第1页 / 共24页
BS EN 1074-6-2008 Valves for water nsupply — Fitness for npurpose requirements nand appropriate nverification tests nPart 6 Hydrants《供水用阀门 目的要求和适当检定试验的合理性 消防栓》.pdf_第2页
第2页 / 共24页
BS EN 1074-6-2008 Valves for water nsupply — Fitness for npurpose requirements nand appropriate nverification tests nPart 6 Hydrants《供水用阀门 目的要求和适当检定试验的合理性 消防栓》.pdf_第3页
第3页 / 共24页
BS EN 1074-6-2008 Valves for water nsupply — Fitness for npurpose requirements nand appropriate nverification tests nPart 6 Hydrants《供水用阀门 目的要求和适当检定试验的合理性 消防栓》.pdf_第4页
第4页 / 共24页
BS EN 1074-6-2008 Valves for water nsupply — Fitness for npurpose requirements nand appropriate nverification tests nPart 6 Hydrants《供水用阀门 目的要求和适当检定试验的合理性 消防栓》.pdf_第5页
第5页 / 共24页
亲,该文档总共24页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、BS EN1074-6:2008ICS 23.060.99NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDValves for watersupply Fitness forpurpose requirementsand appropriateverification testsPart 6: HydrantsLicensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 03/06/2009 03:48, Uncontrol

2、led Copy, (c) BSIThis British Standardwas published under theauthority of the StandardsPolicy and StrategyCommittee on 31 January2009 BSI 2009ISBN 978 0 580 58744 3Amendments/corrigenda issued since publicationDate CommentsBS EN 1074-6:2008National forewordThis British Standard is the UK implementat

3、ion of EN 1074-6:2008. Itsupersedes BS EN 1074-6:2004 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee PSE/7/3, Cast iron, gate, globe and check valves.A list of organizations represented on this committee can be obtained onrequest to its secretary.This

4、publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunityfrom legal obligations.Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 03/06/2009 03:48, Uncontrolled C

5、opy, (c) BSIBS EN 1074-6:2008EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 1074-6November 2008ICS 23.060.99 Supersedes EN 1074-6:2004 English VersionValves for water supply - Fitness for purpose requirements andappropriate verification tests - Part 6: HydrantsRobinetterie pour lalimentation en e

6、au - Prescriptionsdaptitude lemploi et vrifications sy rapportant - Partie 6:Poteaux et bouchesArmaturen fr die Wasserversorgung - Anforderungen andie Gebrauchstauglichkeit und deren Prfung - Teil 6:HydrantenThis European Standard was approved by CEN on 25 September 2008.CEN members are bound to com

7、ply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Manageme

8、nt Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theoff

9、icial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slov

10、enia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2008 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN nati

11、onal Members.Ref. No. EN 1074-6:2008: ELicensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 03/06/2009 03:48, Uncontrolled Copy, (c) BSIBS EN 1074-6:2008EN 1074-6:2008 (E) 2 Contents page Foreword3 Introduction .4 1 Scope 5 2 Normative references 5 3 Terms and definitions .6 4 Design requirements

12、.6 5 Performance requirements .7 5.1 Mechanical strength 7 5.2 Leak-tightness8 5.3 Hydraulic characteristic 9 5.4 Resistance to disinfection products9 5.5 Endurance 10 5.6 Performance of the draining system .10 6 Conformity assessment 11 6.1 General11 6.2 Type tests .11 6.3 Control of production pro

13、cess and quality system .11 7 Marking .11 8 Packaging .11 Annex A (normative) Test method for the resistance of hydrants to bending .13 A.1 General13 A.2 Test procedure.13 Annex B (normative) Test method for the resistance of pillar hydrants to a force applied above ground level15 B.1 General15 B.2

14、Test procedure for pillar hydrants not equipped with a breaking system.15 B.3 Test procedure for pillar hydrants equipped with a breaking system .16 Annex C (normative) Test method for the operation of hydrants 17 C.1 General17 C.2 Test procedure.17 Annex D (normative) Test method for the endurance

15、of hydrants 18 D.1 General18 D.2 Test procedure.18 D.3 Final tests and acceptance criteria18 Annex E (normative) Test method for the performance of draining system 19 E.1 General19 E.2 Test procedure.19 Bibliography 20 Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 03/06/2009 03:48, Uncontro

16、lled Copy, (c) BSIBS EN 1074-6:2008EN 1074-6:2008 (E) 3 Foreword This document (EN 1074-6:2008) has been prepared by Technical Committee CEN/TC 69 “Industrial valves”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by public

17、ation of an identical text or by endorsement, at the latest by May 2009, and conflicting national standards shall be withdrawn at the latest by May 2009. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not

18、 be held responsible for identifying any or all such patent rights. This document supersedes EN 1074-6:2004. The following technical changes were made to take into account the publication of EN 14339:2005 and EN 14384:2005: Clause 1 : deletion of the sentence stating that EN 1074-6 is a priority sta

19、ndard; Clause 3: addition of the definition of draining system depth; Clause 4: addition of a requirement on sealing material; Subclauses 5.1.4 and 5.2.3: deletion of pillar hydrants from Table 2 and addition of a reference to EN 14384:2005; Table 3: addition of draining system depth Pv. EN 1074 con

20、sists of six parts: Part 1: General requirements; Part 2: Isolating valves; Part 3: Check valves; Part 4: Air valves; Part 5: Control valves; Part 6: Hydrants. Part 1, in conjunction with the subsequent parts, lays down the general requirements and test procedures to be carried out in production and

21、 during the assessment of conformity of these valves (type tests). The detailed requirements, which depend on the types of valves, are defined in parts 2 to 6 of this European Standard. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries

22、 are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, S

23、weden, Switzerland and the United Kingdom. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 03/06/2009 03:48, Uncontrolled Copy, (c) BSIBS EN 1074-6:2008EN 1074-6:2008 (E) 4 Introduction This update results from the publication of EN 14339:2005 and EN 14384:2005 which are harmonised under CPD.

24、 Thus EN 1074-6 cannot be a priority standard. As the test of EN 1074-6 are currently used by EN 14339:2005 and EN 14384:2005, the test values have been aligned with these European Standards to prevent any ambiguous interpretation. In respect of potential adverse effects on the quality of water inte

25、nded for human consumption caused by the product covered by this European Standard: 1) this European Standard provides no information as to whether the product can be used without restriction in any of the Member States of the EU or EFTA; 2) it should be noted that, while awaiting the adoption of ve

26、rifiable European criteria, existing national regulations concerning the use and/or the characteristics of this product remain in force. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 03/06/2009 03:48, Uncontrolled Copy, (c) BSIBS EN 1074-6:2008EN 1074-6:2008 (E) 5 1 Scope This European Stan

27、dard defines the minimum fitness for purpose requirements for hydrants to be used in, or connected to, water supply pipe systems, above or below ground (see EN 805), carrying water intended for human consumption. This European Standard specifies the design requirements, the performance requirements,

28、 and the conformity assessment method for hydrants, whatever their type, materials and functions. Where hydrants can be used for fire fighting, irrigation or other function, additional requirements can be given in other standards. This part of EN 1074 deals with the requirements applicable to both u

29、nderground and pillar hydrants, in sizes DN 65 to DN 150, and PFA up to 16 bar. This part of EN 1074 does not give requirements for the outlets or their interface with the hydrants, since they are subject to national standards. 2 Normative references The following referenced documents are indispensa

30、ble for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 558, Industrial valves Face-to-face and centre-to-face dimensions of metal valves for use in fl

31、anged pipe systems PN and Class designated valves EN 681-1, Elastomeric seals Materials requirements for pipe joint seals used in water and drainage applications Part 1: Vulcanized rubber EN 681-2, Elastomeric seals Materials requirements for pipe joint seals used in water and drainage applications

32、Part 2: Thermoplastic elastomers EN 681-3, Elastomeric seals Materials requirements for pipe joint seals used in water and drainage applications Part 3: Cellular material of vulcanized rubber EN 681-4, Elastomeric seals Materials requirements for pipe joint seals used in water and drainage applicati

33、ons Part 4: Cast polyurethane sealing elements EN 1074-1:2000, Valves for water supply Fitness for purpose requirements and appropriate verification tests Part 1: General requirements EN 1074-2:2000, Valves for water supply Fitness for purpose requirements and appropriate verification tests Part 2:

34、Isolating valves EN 1074-3:2000, Valves for water supply Fitness for purpose requirements and appropriate verification tests Part 3: Check valves EN 1092-2, Flanges and their joints Circular flanges for pipes, valves, fittings and accessories, PN designated Part 2: Cast iron flanges EN 1267:1999, Va

35、lves Test of flow resistance using water as test fluid EN 12266-1:2003, Industrial valves Testing of valves Part 1: Pressure tests, test procedures and acceptance criteria Mandatory requirements EN 14384:2005, Pillar fire hydrants Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 03/06/2009 03:

36、48, Uncontrolled Copy, (c) BSIBS EN 1074-6:2008EN 1074-6:2008 (E) 6 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 1074-1:2000 and the following apply. 3.1 hydrant connection to a water supply system including an isolating valve 3.2 pillar hydrant hy

37、drant with a connection point located above ground level, for use by water utilities or to supply water to fire fighting equipment 3.3 breakable pillar hydrant pillar hydrant equipped with a specific device allowing its above ground part to separate from its below ground part, when submitted to an i

38、mpact 3.4 underground hydrant hydrant with a connection point located under ground level, for use by water utilities or to supply water to fire fighting equipment 3.5 theoretical ground level limit between the above ground part and the underground part of the pillar hydrant as installed NOTE This po

39、int is used for pillar positioning on site, once the height of components of the above ground part, the depth of water supply pipeline axis and of the unfreezing device are defined. 3.6 draining system depth Pv distance between the theoretical ground level and the orifice of draining system when the

40、 hydrant is fitted with a draining system 4 Design requirements Hydrants shall be designed in accordance with the design requirements given in Clause 4 of EN 1074-1:2000, with the following additional or different requirements. Sealing material shall be in accordance with EN 681-1, EN 681-2, EN 681-

41、3 or EN 681-4 and shall meet the requirements of 4.9 of EN 1074-1:2000. The requirements of EN 558 (interchangeability) shall not apply to hydrants. When fitted with an inlet flange, it shall be in accordance with EN 1092-2. The outlets shall be in accordance with the national requirements. For hydr

42、ants manually operated, the preferred direction of closure is clockwise. Hydrants designed for anti-clockwise closure shall be marked to indicate the closing direction. If fitted, the breaking system shall be above the ground level and shall be replaceable in-situ. The manufacturer shall indicate in

43、 his technical documentation whether the hydrant is equipped with an automatic draining device. If fitted, such a device shall comply with the National Health and Safety Regulations. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 03/06/2009 03:48, Uncontrolled Copy, (c) BSIBS EN 1074-6:2008E

44、N 1074-6:2008 (E) 7 The manufacturers technical documentation shall indicate whether the hydrant is equipped with a non-return device. 5 Performance requirements 5.1 Mechanical strength 5.1.1 Resistance to internal pressure of the shell and of all pressure containing components Requirement and test

45、shall be in accordance with 5.1.1 of EN 1074-1:2000, except that leakage of an automatic draining device at a pressure less than 1 bar shall not be a reason for failure. To conduct this test the outlets of the hydrant and a drilled drain plug if fitted shall be blanked off with any suitable device.

46、5.1.2 Resistance of the obturator to differential pressure Requirement and test shall be in accordance with 5.1.2 of EN 1074-1:2000 and the test shall be performed in the direction of flow. 5.1.3 Resistance of hydrants to bending and to any force applied above the ground level 5.1.3.1 Resistance of

47、the hydrant to bending Requirements shall be in accordance with the first paragraph of 5.1.3 of EN 1074-1:2000. The test shall be performed in accordance with Annex A on any hydrant in its delivery condition. This test is not required for hydrants designed for installation in a chamber, as given in

48、the manufacturers documentation. The bending moments M to be applied during the test shall be in accordance with the values given in Table 1 of EN 1074-2:2000. 5.1.3.2 Resistance of the pillar hydrant to a force applied above ground level The test shall be performed in accordance with Annex B. If no

49、t equipped with a breaking system, the pillar hydrant shall withstand the force, F, given in the corresponding part of Table 1, remaining leak-tight during the test. If the hydrant is designed to break at ground level, the force to break the hydrant shall be as given in the corresponding part of Table 1. The pillar hydrant shall remain leak-tight after breaking, and all the parts below the breaking system shall be undamaged. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 03/06/2009 03:48, Uncon

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1