1、BSI Standards PublicationBS EN 2267-010:2013Aerospace series Cables,electrical, for general purpose Operating temperaturesbetween 55 C and 260 CPart 010: DR family, single UV laserprintable Product standardCopyright European Committee for Standardization Provided by IHS under license with CENNot for
2、 ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 2267-010:2013 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 2267-010:2013.It supersedes BS EN 2267-010:2005 which is withdrawn.The UK participation in its preparation was entrust
3、ed to TechnicalCommittee ACE/6, Aerospace avionic electrical and fibre optictechnology.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for it
4、s correctapplication. The British Standards Institution 2013. Published by BSI StandardsLimited 2013ISBN 978 0 580 83441 7ICS 49.060Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strat
5、egy Committee on 31 December 2013.Amendments issued since publicationDate Text affectedCopyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 2267-010:2013EUROPEAN STANDARD NORME
6、EUROPENNE EUROPISCHE NORM EN 2267-010 December 2013 ICS 49.060 English Version Aerospace series - Cables, electrical, for general purpose - Operating temperatures between - 55 C and 260 C - Part 010: DR family, single UV laser printable - Product standard Srie arospatiale - Cbles, lectriques, dusage
7、 gnral - Tempratures de fonctionnement comprises entre - 55 C et 260 C - Partie 010: Famille DR, fil simple marquable au laser UV - Norme de produit Luft- und Raumfahrt - Leitungen, elektrisch, fr allgemeine Verwendung - Betriebstemperaturen zwischen - 55 C und 260 C - Teil 010: DR-Familie Einadrige
8、 Leitungen UV-Laser bedruckbar - Produktnorm This European Standard was approved by CEN on 28 September 2013. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alter
9、ation. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made
10、 by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estoni
11、a, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDA
12、RDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 2267-010:2013 ECopyright European Committ
13、ee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 2267-010:2013EN 2267-010:2013 (E) 2 Contents Page Foreword 3 1 Scope 4 2 Normative references 4 3 Terms, definitions, symbols and abbreviations .4 4 M
14、aterials and construction .5 5 Required characteristics .6 6 Quality assurance 9 7 Designation 9 8 Identification and marking . 10 9 Packaging, labelling and delivery lengths . 10 10 Technical specification 10 Copyright European Committee for Standardization Provided by IHS under license with CENNot
15、 for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 2267-010:2013EN 2267-010:2013 (E) 3 Foreword This document (EN 2267-010:2013) has been prepared by the Aerospace and Defence Industries Association of Europe - Standardization (ASD-STAN). After enquiries and votes
16、carried out in accordance with the rules of this Association, this Standard has received the approval of the National Associations and the Official Services of the member countries of ASD, prior to its presentation to CEN. This European Standard shall be given the status of a national standard, eith
17、er by publication of an identical text or by endorsement, at the latest by June 2014, and conflicting national standards shall be withdrawn at the latest by June 2014. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CEN
18、ELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 2267-010:2005. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belg
19、ium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switze
20、rland, Turkey and the United Kingdom. Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 2267-010:2013EN 2267-010:2013 (E) 4 1 Scope This European Standard specifies the chara
21、cteristics of UV laser printable electrical lightweight wires DR family for use in the on-board 115 V (phase to neutral) or 200 V (phase to phase) AC electrical systems of aircraft at operating temperatures between 65 C and 260 C. These cables are demonstrated to be arc resistant in sizes 26 to 14 (
22、115/200 V AC). In addition, cables in sizes 12 AWG and larger may be suitable for use at 230/400 V AC in pressurised zones when installed to take account of possible short circuit effects (at the discretion of the user). It shall also be possible to mark these cables by qualified compatible marking.
23、 These markings shall satisfy the requirements of EN 3838. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the lat
24、est edition of the referenced document (including any amendments) applies. EN 2083, Aerospace series Copper or copper alloy conductors for electrical cables Product standard EN 2084, Aerospace series Cables, electric, single-core, general purpose, with conductors in copper or copper alloy Technical
25、specification EN 2267-002, Aerospace series Cables, electrical, for general purpose Operating temperatures between 55 C and 260 C Part 002: General EN 3475-100 (all parts), Aerospace series Cables, electrical, aircraft use Test methods Part 100: General EN 3838, Aerospace series Requirements and tes
26、ts on user-applied markings on aircraft electrical cables EN 4434, Aerospace series Copper or copper alloy lightweight conductors for electrical cables Product standard (Normal and tight tolerances) EN 9133, Aerospace series Quality management systems Qualification procedure for aerospace standard p
27、arts TR 6058, Aerospace series Cable code identification list 1)3 Terms, definitions, symbols and abbreviations For the purposes of this document, the terms, definitions, symbols and abbreviations given in EN 3475-100 apply. 1) Published as ASD-STAN Technical Report at the date of publication of thi
28、s standard. http:/www.asd-stan.org/ Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 2267-010:2013EN 2267-010:2013 (E) 5 4 Materials and construction 4.1 Materials Conductor
29、: These cable conductors shall be made of copper or copper alloy and nickel plated according to EN 4434 code D. Insulation: For all sizes codes shall be defined to satisfy all required characteristics of Clause 5. For single core, it shall be possible to mark the outer layer of the insulation by UV
30、laser printing. 4.2 Construction See EN 4434 and Table 1. Table 1 Code for nominal section Nominal section AWG aLinear resistance at 20 C External diameter Mass mm2/km mm kg/km max. min. max. max. 001 0,15 26 160,0 0,75 0,84 2,08 002 0,25 24 114,0 0,85 0,96 2,72 004 0,4 22 60,0 1,00 1,10 4,14 006 0,
31、6 20 33,2 1,22 1,34 6,85 010 1 18 21,1 1,46 1,61 10,43 012 1,2 16 14,5 1,76 1,92 14,61 020 2 14 10,9 2,04 2,24 19,78 030 3 12 6,8 2,50 2,70 31,33 051 5 10 4,1 3,13 3,33 49,85 090 9 8 2,3 4,10 4,40 90,00 140 14 6 1,58 5,30 5,70 135,00 220 22 4 0,97 6,71 7,41 222,00 340 34 2 0,61 8,28 9,16 347,00 aAWG
32、 = closest American Wire Gage. 4.3 Number of cores See EN 2267-002. Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 2267-010:2013EN 2267-010:2013 (E) 6 4.4 Colour coding of
33、 cores See EN 2267-002. 5 Required characteristics According to EN 2084 and EN 3475-100. See Table 2. Table 2 (1 of 4) EN 3475- Designation of the test Details 201 Visual examination Applicable including laser marked specimen 202 Mass Applicable; see Table 1. 203 Dimensions Applicable; see Table 1.
34、301 Ohmic resistance per unit length Applicable; see Table 1. 302 Voltage proof test Applicable 303 Insulation resistance Applicable 304 Surface resistance Applicable 305 Overload resistance Applicable T1= (310 5) C; T2= (450 5) C 306 Continuity of conductors Applicable 307 Corona extinction voltage
35、 Not applicable 401 Accelerated ageing Applicable including laser marked specimen Temperature (310 5) C 402 Shrinkage and delamination Applicable Temperature (290 5) C Maximum shrinkage at each end of cable: 0,15 mm2to 0,60 mm2: 0,80 mm; 1,00 mm2to 1,20 mm2: 1,00 mm; 2,00 mm2to 5,00 mm2: 1,20 mm; 9,
36、00 mm2: 1,50 mm; 14,00 mm2: 2,00 mm. 403 Delamination and blocking Applicable Temperature (310 5) C 404 Thermal shock Applicable Temperature (260 5) C and ( 65 2) C Maximum shrinkage at each end of cable: 0,15 mm2to 0,60 mm2: 0,80 mm; 1,00 mm2to 1,20 mm2: 1,00 mm; 2,00 mm2to 5,00 mm2: 1,20 mm; 9,00
37、mm2: 1,50 mm; 14,00 mm2: 2,00 mm. Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 2267-010:2013EN 2267-010:2013 (E) 7 Table 2 (2 of 4) EN 3475- Designation of the test Deta
38、ils 405 Bending at ambient temperature Applicable including laser marked specimen 406 Cold bend test Applicable Temperature ( 65 2) C 407 Flammability Applicable Extinguishing time: 3 s max. 408 Fire resistance Not applicable 409 Air-excluded ageing Not applicable 410 Thermal endurance Applicable 10
39、 000 h at 260 C with curve extrapolation 100 000 h at 200 C with curve reading 411 Resistance to fluids Applicable including laser marked specimens 412 Humidity resistance Applicable Method B Temperature (95 5) C Duration 360 h 413 Wrap back test Applicable 414 Differential scanning calorimeter (DSC
40、 test) Applicable (only if PTFE in the construction) 415 Rapid change of temperature Not applicable 416 Thermal stability Not applicable 501 Dynamic cut-through Applicable Temperatures (20 3) C and (260 5) C Nominal section mm2Cut-through force 20 C N 260 C N 0,15 70 15 0,25 85 30 0,40 110 45 0,60 1
41、40 55 1,00 140 70 1,20 150 85 2,00 150 95 3,00 165 105 5,00 180 120 9,00 195 135 14,00 210 150 Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 2267-010:2013EN 2267-010:2013
42、 (E) 8 Table 2 (3 of 4) EN 3475- Designation of the test Details 502 Notch propagation Applicable Notch depth: 40 m 503 Scrape abrasion Applicable Test force on needle for cables: 0,15 mm2= 5 N; 0,25 mm2to 0,60 mm2= 8 N; 1,00 mm2to 1,20 mm2= 10 N; 2,00 mm2to 9,00 mm2= 12 N; 14,00 mm2= 15 N. 504 Tors
43、ion Applicable T3= (260 5) C; T4 = (310 5) C 505 Tensile test on conductors and strands Applicable 506 Plating continuity Applicable 507 Adherence of plating Applicable 508 Plating thickness Applicable 509 Solderability Not applicable 510 Tensile strength and elongation of extruded insulation, sheat
44、h and jacket material Not applicable 511 Cable-to-cable abrasion Applicable code 006 0,6 mm2, weight 25 N 2 800 000 cycles 512 Flexure endurance Applicable code 006 0,6 mm2, mandrel diameter 15 mm Weight 9 N 1 000 cycles 513 Deformation resistance (Installation with plastic cable ties) Not applicabl
45、e 601 Smoke density Applicable 602 Toxicity Applicable 603 Resistance to wet arc tracking Applicable test size 006 Test voltage 115/200 V Wire damage maximum 70 mm 75 % of collateral wires must pass the wet dielectric voltage proof test EN 3475-302. 604 Resistance to dry arc propagation Applicable T
46、est voltage 115/200 V Wire damage maximum 70 mm 75 % of collateral wires must pass the wet dielectric voltage proof test EN 3475-302. 605 Wet short circuit test Applicable Test voltage 115/200 V Wire damage maximum 70 mm 701 Strippability and adherence of insulation to the conductor Applicable Copyr
47、ight European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 2267-010:2013EN 2267-010:2013 (E) 9 Table 2 (4 of 4) EN 3475- Designation of the test Details 702 Screen pushback capability Not
48、applicable 703 Permanence of manufacturers marking Applicable 704 Flexibility Applicable code 030 to code 140 Maximum force: 3,00 mm2: 8 N; 5,00 mm2: 9 N; 9 mm2: 10 N; 14 mm2: 11 N. 705 Contrast measurement Applicable K 50 % 706 Laser markability Applicable UV laser EN 3838 Subclause 6.2 “Permanence of markings“ Applicable Subclause 6.5 “Exposure to light“ Applicable 6 Quality assurance See EN 9133. 7 Designation 7.1 Identifi