1、BSI Standards PublicationBS EN 3660-064:2016Aerospace series Cableoutlet accessories for circularand rectangular electrical andoptical connectorsPart 064: Cable outlet, style K, straight, forheat shrinkable boot, shielded, sealed, self-locking for EN 2997 Product standardBS EN 3660-064:2016 BRITISH
2、STANDARDNational forewordThis British Standard is the UK implementation of EN 3660-064:2016. It supersedes BS EN 3660-064:2009 which is withdrawn. The UK participation in its preparation was entrusted to Technical Committee ACE/6, Aerospace avionic electrical and fibre optic technology.A list of org
3、anizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2016.Published by BSI Standards Limited 2
4、016ISBN 978 0 580 89595 1 ICS 49.060 Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 January 2016.Amendments/corrigenda issued since publicationDate T e x t a
5、 f f e c t e dBS EN 3660-064:2016EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 3660-064 January 2016 ICS 49.060 Supersedes EN 3660-064:2009English Version Aerospace series - Cable outlet accessories for circular and rectangular electrical and optical connectors - Part 064: Cable outlet, style
6、 K, straight, for heat shrinkable boot, shielded, sealed, self-locking for EN 2997 - Product standard Srie arospatiale - Accessoires arrire pour connecteurs circulaires et rectangulaires lectriques et optiques - Partie 064 : Raccord, type K, droit, blind, tanche, pour manchon thermortractable, auto-
7、frein pour EN 2997 - Norme de produit Luft- und Raumfahrt - Endgehuse fr elektrische und optische Rund- und Rechtecksteckverbinder - Teil 064: Endgehuse, Bauform K, gerade, fr wrmeschrumpfende Bauteile, Schirmanschlu, abgedichtet, selbstsichernd fr EN 2997 - Produktnorm This European Standard was ap
8、proved by CEN on 8 June 2015. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
9、standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language a
10、nd notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hung
11、ary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey andUnited Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENEL
12、EC Management Centre: Avenue Marnix 17, B-1000 Brussels 2016 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 3660-064:2016 EBS EN 3660-064:2016Contents Page European foreword 3 1 Scope 4 2 Normative references 4 3 Terms and definit
13、ions . 5 4 Characteristics . 5 5 Tests . 13 6 Designation . 20 7 Marking . 20 8 Technical specification . 20 EN 3660-064:2016BS EN 3660-064:2016European foreword This document (EN 3660-064:2016) has been prepared by the Aerospace and Defence Industries Association of Europe - Standardization (ASD-ST
14、AN). After enquiries and votes carried out in accordance with the rules of this Association, this European Standard has received the approval of the National Associations and the Official Services of the member countries of ASD, prior to its presentation to CEN. This European Standard shall be given
15、 the status of a national standard, either by publication of an identical text or by endorsement, at the latest by July 2016, and conflicting national standards shall be withdrawn at the latest by July 2016. Attention is drawn to the possibility that some of the elements of this document may be the
16、subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 3660-064:2009. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to impleme
17、nt this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, S
18、lovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. EN 3660-064:2016BS EN 3660-064:20161 Scope This European Standard defines a range of cable outlets, style K, straight, shielded, sealed, self-locking (anti-rotational) for heat shrinkable boot, and / or metallic band under
19、 the following conditions: The mating connectors are listed in EN 3660-002. NOTE Class N in EN 3660-001 cross refers to class F in EN 3660-064. Temperature range, Class F (N) : 65 C to 200 C (See note above); Class K : 65 C to 200 C; Class KE : 65 C to 260 C; Class W : 65 C to 175 C; Class T : 65 C
20、to 175 C (Nickel PTFE plating); Class Z : 65 C to 175 C (Zinc Nickel plating). Associated electrical accessories : EN 3660-033 Metallic band (for shield termination). These cable outlets are designed for termination of overall shielding braid and / or individual cable shields. They accommodate/permi
21、t the termination of heat shrinkable boots. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of
22、the referenced document (including any amendments) applies. EN 2591- 1), Aerospace series Elements of electrical and optical connection Test methods EN 2997 (series), Aerospace series Connectors, electrical, circular, coupled by threaded ring, fire-resistant or non fire-resistant, operating temperat
23、ures 65 C to 175 C continuous, 200 C continuous, 260 C peak EN 3660-001, Aerospace series Cable outlet accessories for circular and rectangular electrical and optical connectors Part 001: Technical specification EN 3660-002, Aerospace series Cable outlet accessories for circular and rectangular elec
24、trical and optical connectors Part 002: Index of product standards EN 3660-033, Aerospace series Cable outlet accessories for circular and rectangular electrical and optical connectors Part 033: Stainless steel banding band, style Z, for attachment of individual and/or overall screens to cable outle
25、ts Product standard 2)AS85049A, Connector accessories, electrical general specification for- 3)IEC 60529, Degrees of protection provided by enclosures (IP Code) DIN 82, Knurling 1) All its parts quoted in this European Standard. 2) In preparation at the date of publication of this European Standard.
26、 3) Published by: SAE National (US) Society of Automotive Engineers http:/www.sae.org/EN 3660-064:2016BS EN 3660-064:20163 Terms and definitions For the purposes of this document, the terms and definitions given in EN 3660-001 apply. (Self-locking / anti rotational definition) A self-locking or anti
27、 rotational mechanism provides a nut rotation with moderate torque in the mated direction and provides a greater torque in the unmated direction. 4 Characteristics 4.1 Dimensions and mass For dimensions and mass, see Figure 1 and Table 1 to Table 4. For cable entry dimensions, see 4.2. All dimension
28、s are in millimetres. Key 1 Thread C 2 Marking 3 Number of teeth N 4 Four tooling holes spaced 90 apart. 2,60, depth, 1,27 5 Straight knurl. Pitch manufacturers option. 6 RKV 08 DIN 82. Figure 2. (Please note there may be crossover dependent on diameter and pitch) 7 Clearance on thread C 8 Break edg
29、e NOTE 1 Cable outlets may be manufactured as cast, fabricated or machined (manufactures option) NOTE 2 No sharp edges / burrs permissible on internal or external surfaces / joints. Surface finish of on all internal surfaces Figure 1 1,6 m max. EN 3660-064:2016BS EN 3660-064:2016Table 1 Fixed dimens
30、ions of shell Dimensions in millimetres Shell size A B C E max. max. Thread max. 08 22,48 15,67 0,500-20UNF 15,3 10 25,65 18,64 0,625-24UNEF 15,3 12 28,83 21,79 0,750-20UNEF 15,3 14 32,00 24,99 0,875-20UNEF 15,3 16 35,18 28,24 1,000-20UNEF 15,3 18 38,55 30,94 1,0625-18UNEF 15,3 20 41,53 34,16 1,1875
31、-18UNEF 15,3 22 44,70 37,29 1,3125-18UNEF 15,3 24 47,89 40,46 1,4375-18UNEF 15,3 28 54,23 49,45 1,750-18UNS 15,3 Table 2 Variable dimensions of wiring chamber Dimensions in millimetres Length code wiring chamber H J max. max. A 27,5 8,57 B 35,5 16,57 C 40,5 21,60 D 50,5 31,60 The code and dimensions
32、 of the wiring chamber shall be valid for all sizes of cable outlet. Table 3 Mass for classes F (N), T, W and Z Nominal mass in grams Shell size code Cable entry size code Length code wiring chamber A B C D E F G H J K L M 08 10,7 11,3 A 11,4 12,0 B 11,9 12,5 C 12,7 13,3 D 10 12,4 13,1 13,7 14,3 A 1
33、3,4 14,1 14,7 15,3 B 14,0 14,7 15,3 15,9 C EN 3660-064:2016BS EN 3660-064:2016Shell size code Cable entry size code Length code wiring chamber A B C D E F G H J K L M 15,2 15,9 16,6 17,1 D 12 14,5 14,9 15,3 16,1 16,6 17,2 A 15,7 16,2 16,6 17,3 17,9 18,4 B 16,5 16,9 17,4 18,1 18,7 19,2 C 18,1 18,5 18
34、,9 19,6 20,2 20,7 D 14 17,8 18,2 18,6 19,0 19,2 20,0 21,2 A 19,3 19,7 20,1 20,5 20,8 21,6 22,7 B 20,3 20,7 21,1 21,4 21,7 22,5 23,7 C 22,2 22,6 23,0 23,3 23,6 24,4 25,6 D 16 20,0 20,5 20,9 21,2 21,5 21,8 23,0 24,0 A 21,8 22,3 22,7 23,0 23,3 23,6 24,8 25,8 B 23,0 23,4 23,8 24,1 24,4 24,7 25,9 27,0 C
35、25,2 25,6 26,0 26,4 26,7 27,0 28,1 29,2 D 18 21,2 21,6 22,0 22,4 22,6 22,9 23,5 24,9 x A 23,2 23,6 24,0 24,4 24,6 24,9 25,5 26,9 B 24,4 24,8 25,2 25,6 25,9 26,2 26,7 28,2 C 26,9 27,3 27,7 28,1 28,4 28,7 29,2 30,6 D 20 25,7 26,1 26,5 26,9 27,2 27,5 28,0 28,4 29,6 A 28,0 28,4 28,8 29,2 29,4 29,7 30,3
36、30,7 31,9 B 29,4 29,8 30,2 30,6 30,9 31,2 31,7 32,1 33,3 C 32,3 32,7 33,1 33,4 33,7 34,0 34,6 35,0 36,2 D 22 27,1 27,5 27,9 28,3 28,5 28,8 29,4 29,8 30,3 31,3 A 29,6 30,0 30,4 30,8 31,1 31,4 32,0 32,3 32,9 33,8 B 31,2 31,6 32,0 32,4 32,7 33,0 33,5 33,9 34,5 35,4 C 34,4 34,8 35,2 35,6 35,9 36,2 36,7
37、37,1 37,7 38,6 D 24 33,1 33,5 33,9 34,3 34,5 34,9 35,4 35,8 36,4 36,6 37,7 A 35,9 36,4 36,8 37,1 37,4 37,7 38,3 38,6 39,2 39,4 40,5 B 37,7 38,1 38,5 38,9 39,2 39,5 40,0 40,4 41,0 41,2 42,3 C 41,3 41,7 42,1 42,4 42,7 43,0 43,6 44,0 44,5 44,7 45,8 D 28 43,9 43,5 43,9 44,3 44,5 44,9 45,4 45,8 46,4 46,6
38、 47,0 48,0 A 46,2 46,7 47,1 47,4 47,7 48,0 48,6 48,9 49,5 49,7 50,1 51,1 B 48,2 48,6 49,0 49,4 49,7 50,0 50,5 50,9 51,5 51,7 52,1 53,1 C 52,3 52,7 53,1 53,4 53,7 54,0 54,6 55,0 55,5 55,7 56,8 58,8 D EN 3660-064:2016BS EN 3660-064:2016Table 4 Mass for classes K and KE Nominal mass in grams Shell size
39、 code Cable entry size code Length code wiring chamber A B C D E F G H J K L M 08 26,9 28,5 A 28,7 30,3 B 29,8 31,4 C 31,9 33,6 D 10 31,0 32,8 34,6 36,0 A 33,5 35,3 37,0 38,5 B 35,0 36,8 38,6 40,0 C 38,1 39,9 41,7 43,1 D 12 35,9 37,0 38,2 40,1 41,6 43,0 A 39,0 40,1 41,3 43,2 44,7 46,1 B 41,0 42,1 43
40、,2 45,1 46,7 48,1 C 44,9 46,0 47,1 49,0 50,6 51,9 D 14 42,9 44,0 45,1 46,0 46,8 48,9 52,0 A 46,7 47,8 48,9 49,8 50,6 52,7 55,8 B 49,1 50,2 51,3 52,2 53,0 55,1 58,2 C 53,9 55,0 56,0 57,0 57,7 59,9 63,0 D 16 48,2 49,3 50,4 51,4 52,1 52,9 56,1 58,8 A 52,8 53,9 55,0 55,9 56,6 57,4 60,6 63,4 B 55,6 56,7
41、57,8 58,7 59,4 60,3 63,4 66,2 C 61,3 62,4 63,4 64,4 65,1 65,9 69,1 71,9 D 18 52,1 53,2 54,3 55,2 55,9 56,8 58,3 62,1 A 57,1 58,2 59,3 60,3 60,9 61,8 63,3 67,1 B 60,2 61,4 62,4 63,4 64,1 64,9 66,4 70,2 C 66,5 67,6 68,7 69,7 70,3 71,2 72,7 76,5 D 20 62,0 63,2 64,2 65,2 65,9 66,7 68,2 69,2 72,4 A 67,8
42、68,9 70,0 70,9 71,6 72,4 74,0 74,9 78,1 B 71,4 72,5 73,5 74,5 75,2 76,0 77,5 78,5 81,7 C 78,5 79,6 80,7 81,7 82,3 83,2 84,7 85,7 88,8 D 22 66,1 67,2 68,3 69,2 69,9 70,8 72,3 73,3 74,7 77,0 A 72,5 73,6 74,7 75,6 76,3 77,2 78,7 79,7 81,1 83,4 B 76,5 77,6 78,7 79,7 80,3 81,2 82,7 83,7 85,1 87,5 C 84,5
43、85,6 86,7 87,7 88,4 89,2 90,7 91,7 93,1 95,5 D 24 78,6 79,8 80,8 81,8 82,5 83,3 84,8 85,8 87,3 87,7 90,7 A EN 3660-064:2016BS EN 3660-064:2016Shell size code Cable entry size code Length code wiring chamber A B C D E F G H J K L M 85,8 86,9 88,0 88,9 89,6 90,4 91,9 92,9 94,4 94,8 97,8 B 90,2 91,3 92
44、,4 93,4 94,1 94,9 96,4 97,4 98,8 99,3 102,3 C 99,1 100,2 101,3 102.3 103,0 103,8 105,3 106,3 107,7 108,2 111,2 D 28 103,6 104,8 105,8 106,8 107,5 108,3 109,8 110,8 112,3 112,7 113,7 116,7 A 111,8 112,9 114,0 114,9 115,6 116,4 117,9 118,9 120,4 120,8 121,8 124,8 B 116,7 117,8 118,9 119,9 120,6 121,4
45、122,9 123,9 125,3 125,8 126,8 129,8 C 126,7 127,8 128,9 129,9 130,6 131,4 132,9 133,9 135,3 135,8 136,8 139,8 D 4.2 Cable entry dimensions See Figure 2, Table 5. NOTE No burrs or sharp edges permitted Figure 2 Cable entry EN 3660-064:2016BS EN 3660-064:2016Table 5 Dimensions in millimetres Cable ent
46、ry size code A B C D Bundle/ Cable diameter 0,1 0,1 0,3 + 0,2 0 min. max. A 4,7 7,7 12,2 1,12 2,0 4,0 B 6,4 9,4 14,0 1,12 3,9 5,5 C 7,9 11,0 15,5 1,12 5,4 7,5 D 9,5 12,6 17,1 1,12 7,4 9,0 E 11,1 14,1 18,7 1,12 9,4 10,5 F 12,7 15,7 20,3 1,12 10,4 12,0 G 15,9 18,9 23,5 1,12 12,4 15,5 H 19,1 22,0 26,7
47、1,12 15,4 18,5 J 22,2 25,2 29,8 1,75 18,4 21,5 K 25,5 28,4 33,0 1,75 21,4 25,0 L 28,6 31,5 36,2 1,75 25,4 28,0 M 31,8 34,7 39,4 1,75 28,4 31,0 NOTE The cable outlet shall be selected in accordance with the diameter of the cable bundle. 4.3 Associated connectors See EN 3660-002. EN 3660-064:2016BS EN 3660-064:20164.4 Front interface 4.4.1 AS85049 interface all classes See Figure 3, Figure 4 a