BS EN 6059-504-2014 Aerospace series Electrical cables installation Protection sleeves Test methods Temperature rise within a loom due to self-heating when protected by a sleeve《航空.pdf

上传人:twoload295 文档编号:552076 上传时间:2018-12-09 格式:PDF 页数:12 大小:1,021.71KB
下载 相关 举报
BS EN 6059-504-2014 Aerospace series Electrical cables installation Protection sleeves Test methods Temperature rise within a loom due to self-heating when protected by a sleeve《航空.pdf_第1页
第1页 / 共12页
BS EN 6059-504-2014 Aerospace series Electrical cables installation Protection sleeves Test methods Temperature rise within a loom due to self-heating when protected by a sleeve《航空.pdf_第2页
第2页 / 共12页
BS EN 6059-504-2014 Aerospace series Electrical cables installation Protection sleeves Test methods Temperature rise within a loom due to self-heating when protected by a sleeve《航空.pdf_第3页
第3页 / 共12页
BS EN 6059-504-2014 Aerospace series Electrical cables installation Protection sleeves Test methods Temperature rise within a loom due to self-heating when protected by a sleeve《航空.pdf_第4页
第4页 / 共12页
BS EN 6059-504-2014 Aerospace series Electrical cables installation Protection sleeves Test methods Temperature rise within a loom due to self-heating when protected by a sleeve《航空.pdf_第5页
第5页 / 共12页
亲,该文档总共12页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、BSI Standards PublicationBS EN 6059-504:2014Aerospace series Electricalcables, installation Protection sleeves TestmethodsPart 504: Temperature rise within a loomdue to self-heating when protected by asleeveBS EN 6059-504:2014 BRITISH STANDARDNational forewordThis British Standard is the UK implemen

2、tation of EN 6059-504:2014.The UK participation in its preparation was entrusted to TechnicalCommittee ACE/6, Aerospace avionic electrical and fibre optictechnology.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to i

3、nclude all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2014. Published by BSI StandardsLimited 2014ISBN 978 0 580 84525 3ICS 49.060Compliance with a British Standard cannot confer immunity fromlegal obligations.This Briti

4、sh Standard was published under the authority of theStandards Policy and Strategy Committee on 31 July 2014.Amendments issued since publicationDate Text affectedBS EN 6059-504:2014EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 6059-504 July 2014 ICS 49.060 English Version Aerospace series - El

5、ectrical cables, installation - Protection sleeves - Test methods - Part 504: Temperature rise within a loom due to self-heating when protected by a sleeve Srie arospatiale - Cbles lectriques, installation - Gaines de protection - Mthodes dessais - Partie 504 : Augmentation de temperature due lauto-

6、chauffement dun faisceau de cbles avec gaine de protection Luft- und Raumfahrt - Elektrische Leitungen, Installation - Schutzschluche - Prfverfahren - Teil 504: Temperaturanstieg durch Selbsterwrmung eines Leitungsbndels in einem Schutzschlauch This European Standard was approved by CEN on 27 Decemb

7、er 2013. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obta

8、ined on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CE

9、N-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland

10、, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre

11、: Avenue Marnix 17, B-1000 Brussels 2014 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 6059-504:2014 EBS EN 6059-504:2014EN 6059-504:2014 (E) 2 Contents Page Foreword 3 1 Scope 4 2 Normative references 4 3 Equipment 4 4 Preparati

12、on of test specimens .4 5 Test methods 5 6 Acceptance criteria 7 BS EN 6059-504:2014EN 6059-504:2014 (E) 3 Foreword This document (EN 6059-504:2014) has been prepared by the Aerospace and Defence Industries Association of Europe - Standardization (ASD-STAN). After enquiries and votes carried out in

13、accordance with the rules of this Association, this Standard has received the approval of the National Associations and the Official Services of the member countries of ASD, prior to its presentation to CEN. This European Standard shall be given the status of a national standard, either by publicati

14、on of an identical text or by endorsement, at the latest by January 2015, and conflicting national standards shall be withdrawn at the latest by January 2015. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shal

15、l not be held responsible for identifying any or all such patent rights. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denm

16、ark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 6059-504

17、:2014EN 6059-504:2014 (E) 4 1 Scope This European Standard specifies methods of assessing the behaviour and temperature increase of cable loom when fitted with protection sleeves or conduits subject to normal and fault currents. It shall be used together with EN 6059-100. 2 Normative references The

18、following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 6059-100

19、, Aerospace series Electrical cables, installation Protection sleeves Test methods Part 100: General 3 Equipment The following equipment shall be required for these tests: a) The test shall be carried out at ambient temperature in a chamber where the whole unit shall be sheltered from draughts. An e

20、xtraction shall be provided but only operated after completion of the test. b) To identify the appearance of smoke, a screen with black and white horizontal bands or any other device shall be used. 4 Preparation of test specimens The test shall be carried out at ambient temperature Ta(typically 20 C

21、) in a chamber where the whole unit shall be sheltered from draughts. An extraction shall be provided but only operated after completion of the test. To identify the appearance of smoke, a screen with black and white horizontal bands or any other device shall be used. Means of electrical power conne

22、ction at both extremities shall not provide any risks of temperature increase. A 3 m long cable loom 1)shall be laid up using air frame cables, whos maximum temperature rating is at least that of the sleeve material being tested, so that it forms a concentric bundle. The looms conductors shall be wi

23、red in series so as to ensure that at the same current passes through each conductor. The resulting loom shall be of such a diameter that it fully fills the protective sleeve being tested. A means shall be provided so that the voltage drop across the centre conductor can be monitor over a length of

24、at least 1,5 m (the test zone). 1) The temperature rating of the cables insulation shall be at least as high as that of the sleeve being tested. BS EN 6059-504:2014EN 6059-504:2014 (E) 5 5 Test methods 5.1 Method 1 5.1.1 Principle Assessment of the increase in temperature caused by fitting a protect

25、ive sleeve over a cable loom (heat transfer ratio). 5.1.2 Procedure Suspend the cable loom (without the protective sleeve being fitted) so that at least the central 2 m section, including the test zone is horizontal and unsupported. Suspend a weight from the ends of the cable in order to reduce sagg

26、ing throughout the test Figure 1. Apply a small electric current 2)Isothe conductor and measure the voltage drop over test zone V20. Calculate the loom resistance R20.Now increase the current so as tisignificantly warm the loom by approximately 40C. Record the new current ITand voltage drop values V

27、t. Using these values calculate the resistance of the wire conductor RT. The temperature T (in C) of the wire conductor is determined from the change in resistance, using the following formula: += 112020tRRTwhere Rtis the resistance (in ) of the conductor at temperature T; R20is the resistance (in _

28、) of the conductor at 20 C; T is the temperature of the conductor (in C); see Table 1. Table 1 Base metal Copper alloy Copper Aluminium 0,003 5 0,004 0,004 Adjust the current so that the conductor temperature stabilizes at a temperature 40 C above ambient. Maintain this temperature TAfor 30 min. and

29、 record the current that is being applied IA to maintain it. 2) This current should not be so low that it does not increase the loom temperature. BS EN 6059-504:2014EN 6059-504:2014 (E) 6 The loom is now to be fitted with a length of over sleeve sufficiently long so as to completely cover the loom b

30、eyond the two voltage pick off points. The current IAis to be reapplied and after 30 min the loom temperature TBcalculated. The protective sleeves heat transfer ratio shall now be calculated using the following formula: Heat transfer ratio 100bA=TT5.2 Method 2 5.2.1 Principle Assessment of internal

31、overheating of a protective sleeve by the loom within. 5.2.2 Procedure Suspend the cable loom (without the protective sleeve being fitted, so that at least the central 2 m section, including the test zone is horizontal and unsupported. Suspend a weight from one end of the cable in order to reduce sa

32、gging throughout the test. Apply a small electric current 2)Isothe conductor and measure the voltage drop over test zone V20. Calculate the loom resistance R20.Now fit the protective sleeve with a length of over sleeve sufficiently long so as to completely cover the loom beyond the two voltage pick

33、off points. Raise the current within the loom so as to raise the temperature of the cable loom to value of the maximum rated temperature of the protective sleeve material T1. Record the new current ITand voltage drop values Vt. Using these values calculate the resistance of the wire conductor RT. Th

34、e temperature T (in C) of the wire conductor is determined from the change in resistance, using the following formula: += 112020tRRTwhere Rtis the resistance (in ) of the conductor at temperature T; R20is the resistance (in _) of the conductor at 20 C; T is the temperature of the conductor (in C); s

35、ee Table 1. Now raise the loom temperature to a value T2which is 30 C above the maximum rated temperature of the protective sleeve material. This temperature is to be maintained for 15 min. BS EN 6059-504:2014EN 6059-504:2014 (E) 7 6 Acceptance criteria 6.1 Method 1 The heat transfer ratio shall not

36、 exceed the value specified in the product standard. 6.2 Method 2 At temperature T1there shall be no indication of visible smoke, or smell or appreciable colour change to the protective sleeve. At temperature T2there shall be no indication of spontaneous combustion. After cooling from temperature T2

37、to ambient there shall be no indication of separation and/or embrittlement of the protective sleeve. Key 1 Test zone Figure 1 Test fixture This page deliberately left blankThis page deliberately left blankBSI is the national body responsible for preparing British Standards and other standards-relate

38、d publications, information and services.BSI is incorporated by Royal Charter. British Standards and other standardization products are published by BSI Standards Limited.British Standards Institution (BSI)BSI Group Headquarters389 Chiswick High Road London W4 4AL UKAbout usWe bring together busines

39、s, industry, government, consumers, innovators and others to shape their combined experience and expertise into standards -based solutions.The knowledge embodied in our standards has been carefully assembled in a dependable format and refined through our open consultation process. Organizations of a

40、ll sizes and across all sectors choose standards to help them achieve their goals.Information on standardsWe can provide you with the knowledge that your organization needs to succeed. Find out more about British Standards by visiting our website at or contacting our Customer Services team or Knowl

41、edge Centre.Buying standardsYou can buy and download PDF versions of BSI publications, including British and adopted European and international standards, through our website at where hard copies can also be purchased. If you need international and foreign standards from other Standards Development

42、 Organizations, hard copies can be ordered from our Customer Services team.SubscriptionsOur range of subscription services are designed to make using standards easier for you. For further information on our subscription products go to British Standards Online (BSOL) youll have instant access to ove

43、r 55,000 British and adopted European and international standards from your desktop. Its available 24/7 and is refreshed daily so youll always be up to date. You can keep in touch with standards developments and receive substantial discounts on the purchase price of standards, both in single copy an

44、d subscription format, by becoming a BSI Subscribing Member. PLUS is an updating service exclusive to BSI Subscribing Members. You will automatically receive the latest hard copy of your standards when theyre revised or replaced. To find out more about becoming a BSI Subscribing Member and the benef

45、its of membership, please visit a Multi-User Network Licence (MUNL) you are able to host standards publications on your intranet. Licences can cover as few or as many users as you wish. With updates supplied as soon as theyre available, you can be sure your documentation is current. For further inf

46、ormation, email .RevisionsOur British Standards and other publications are updated by amendment or revision. We continually improve the quality of our products and services to benefit your business. If you find an inaccuracy or ambiguity within a British Standard or other BSI publication please info

47、rm the Knowledge Centre.CopyrightAll the data, software and documentation set out in all British Standards and other BSI publications are the property of and copyrighted by BSI, or some person or entity that owns copyright in the information used (such as the international standardization bodies) an

48、d has formally licensed such information to BSI for commercial publication and use. Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means electronic, photocopying, recording or other

49、wise without prior written permission from BSI. Details and advice can be obtained from the Copyright & Licensing Department.Useful Contacts:Customer ServicesTel: +44 845 086 9001Email (orders): Email (enquiries): SubscriptionsTel: +44 845 086 9001Email: Knowledge CentreTel: +44 20 8996 7004Email: knowledgecentrebsigroup

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf