1、BSI BS*EN*329100 O3 3624669 0573677 802 BRITISH STANDARD Harmonized system of quality assessment for electronic components Sectional specification: Wirewound surface mounting inductors The European standard EN 129100 : 1993, together with its amendment Al : 1995, has the status of a British Standard
2、 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMIITED BY COPYILIGHT LAW BS EN 129100 : 1995 Incorporating AmendmentNo. 1 BSI BSmEN*3293OO O1 W 1624669 0573698 749 W under the authority of the stendards Board and comes into Amd. No. Date effect on, 15 April 1995 9141 November O BSI 1995 1996 The foi
3、lowing BI references relat to the work on this standard: Committee reference EPU51 Dmft for comment 9 i 133573 M= ISBN O 6?J 22674 O b 129100 : 1995 Issue 2. November 1996 hdirompanents.Gaeric -wRFRFndind- IEC 68 HD 143.3 S2 Bs 6062 Packaging of mztinwyustapes Compliance with a British Standard does
4、 not of itself confer immunity from legal obigations. BSI BS*EN*L27LOO EUROPEAN STANDARD NORME EUROPENNE EUROPBSCHE NORM i - O3 Lb2Ybb 0573702 TTT EN 129100 + Al February 1993 August 1995 Descrbrs: Quaiity, electronic components, inductors English version Sectional specification: Wirewound surface m
5、ounting inductors (iidudes amendment Ai : 1995) Spcification intermiaire: Rahmenspezifikation : (A prsent, cee spcincation nexiste pas en f=nInderunig Al : 1996) This European Standard was approved by CENELEC Electronic Components Committee (CECC) on 23 April 1992. CENELEC members are bound to compl
6、y with the CENKENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-taiate lists and bibliographical references concerning such nationai standards may be obtained on application to the Centrai Secret
7、ariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as th
8、e official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugai, Spain, Sweden, Switzerland and United Kingdom. The membership of the CECC is identical
9、, with the exception of the national electrotechnical committees of Greece, Iceland and Luxembourg. CENELEC European Committee for Eectechnicai Stanciaxdization Comit Europen de Nonnalisation Electrotechnique Europisches Komitee fi Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B
10、-1050 Brussels O 1993 Copyright reserved to CENELEC members Ref. No. EN 129100 : 1993 + Al : 1995 E BSI BS*EN*129100 O3 1624bb 0573703 936 Issue 2, November 1996 EN 129100 : 1993 Foreword The CENELEC Electmnic Components Committee (CJXC) is composed of those member countries of the European Conunitt
11、ee for Eltechnicai standardization (CENELEC) who wish to take part in a harmonized System for electronic components of assessed quality. The object of the System is to facilitate international trade by the harmoniztion of the slpecifications and quality assessment procedures for electxonic component
12、s, and by the grant of an internationally recognised Mark, or Certificate, of conformity. The components produced under the System ate thereby acceptable in ali member countries without further Wing. This specitcation was prepared by CECC WG 12, Magnetic components: Magnetic wound components. The te
13、xt of the draft based on document CECC (Secretariat) 2864 was submitted to the formal vote; together with the voting report, circulated as document CECC (Secretariat) 3057, it was approved by CECC as EN 129100 on 23 April 1992. “he following dates were fixed: - latestdateof announcement of the EN at
14、 national level - latest date of publication of an identicai national standard - latest date of declaration of natiomd standards obsolescence of confiicting national standards - latest date Of withdrawal (doa) 1993-06-17 (dop) 1993-12-17 1993-12-17 (dow) 2003-06-17 Foreword of amendment Al This amen
15、dment was prepared by Working Group CLCRU= CECcbwG DE. The text of the draR based on document CECC (secretaria) 3585 was submied to the formai vote; together with the voting report, chuMeci as document CECC (Secreu) 3634, it was approved as amendment Al to EN 129100 : 1993 on 1994-1223. The followin
16、g dates were ked: latest date by which the amendmenthastobe implemented at national level by pubiication of an identicai dona3 standard or by endorsement (dop) 1996-10-24 latest date by which the national standards conflicting with the amendment have to be withdrawn (dow) 1996-10-24 FOREWORD Clause
17、1.1 1.2 1.3 :,4 1.5 Issue 2, November 1996 CONTENTS SECTION 1 - GENERAL scope Related documents Information to be given in a detail specification Terminology Marking page 3 EN 129100 : 1993 SECTION 2 - PREFERRED RATINGS AND CHARACTERISTICS 2.1 Preferred climatic categories 2.2 Preferred values of ra
18、tings SECTION 3 - QUALITY ASSESSMENT PROCEDURES 3.1 Primary stage of manufacture 3.2 Structurally similar components 3.3 Certified test records 3.4 Qualification approval 3.5 Quality conformance inspection 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 SECTION 4 - TESTS AND MEASURING M
19、ETHODS Mounting Visual examination and check of dimensions Electrical tests Shear test Substrate bending test Resistance to soldering heat Solderability Rapid change of temperature Climatic sequence Damp heat, steady state Endurance Inductance change with current Solvent resistance Temperature rise
20、Passive flammability Active flammability 2 4 8 8 8 10 10 10 10 10 12 19 19 21 22 23 24 25 26 28 28 29 29 30 30 30 31 31 ANNEX A: Test schedue for Qualification Approval O BSI 1996 32 BSI BS*EN*129100 O1 1624669 0573705 709 = fige 4 EN 129100 : 1993 SECTION 1 - GENERAL 1.1 scope This specification ap
21、plies to wire wound fixed rectangular shaped surface mounting (SM) inductors with a magnetic or non-magnetic core for use in electronic equipment. These inductors are intended to be mounted directly onto substrates or boards by their terminations. It prescribes preferred ratings and characteristics
22、and selects from CECC 29 o00 (EN 129 000:1993) the appropriate quality assessment procedures and measuring methods and gives general performance requirements for this type of inductor. 1.2 Related documents IS0 3 IEC 51(Sec)257 IEC 63 Amendment No. 1 Amendment No. 2 Preferred numbers - Series of pre
23、ferred numbers Marking codes for inductors Preferred number series for resistors and capacitors IEC 68 Basic environmental testing procedures CECC 29 O00 IEC 410 IEC 286-3 Generic specification: Fixed RF wound inductors Sampling plana and procedures for inspection by attributes Packaging of componen
24、ts for automatic handling; Part 3: Packaging of leadless components on continuoue tapes. Note: The above references apply to the current edition8 except for IEC 68. 1.3 Information to be uiven in a detail eecification Detail specifications shall be derived from the relevant blank detail specificatio
25、n. - BSI BS*EN*L29100 O1 W Lb24bb 057170b 645 = Page 5 EN 12910 : 1993 Detail specifications shall not specify requirements inferior to those of the generic, sectional or blank detail specification. When more severe requirements are included, they shall be listed in 1.9 of the detail specification a
26、nd indicated in the test schedules, for example by an asterisk. Note: The information given in 1.3.1 may for convenience be presented in tabular form. The following information shall be given in each detail specification and the values quoted shall preferably be selected from those given in the appr
27、opriate clause of this sectional specification. 1.3.1 Outline drawinq and dimensions There shall be an illustration of the inductor as an aid to easy recognition and for comparison of the inductor with others. Dimensions and their associated tolerances, which affect interchangeability and mounting,
28、shall be given in the detail specification. All dimensions shall be stated in mm. Normally the numerical values shall be given for the length, the width and height of the body. When necessary, for example when a number of items (sizes and inductance ranges) is covered by a detail specification, the
29、dimensions and their associated tolerances shall be placed in a table below the drawing. When the configuration is other than described above, the detail specification shall state such dimensional information as will adequately describe the inductor. 1.3.2 Mount inq The detail specification shall gi
30、ve guidance on method of mounting for normal use. Mounting or test and measurement purposes (when required) shall be in accordance with 4.1. 1.3.3 Ratinss and characteristics The ratings and characteristics shall be in accordance with the relevant clauses of this specification, together with the fol
31、lowing: (1) Rated inductance ranqe See 2.2.1 Note: When products approved to the detail specification have different ranges, the following statement should be added: “The range of inductance values available in each size is given in the current CECC O0 200 (Register of Firms, Products and Services A
32、pproved under the CECC System) “ . BSI BS*EN*329300 O3 - 3b24bb 0573707 583 W Page 6 EN 129100 : 1993 (2) Particular characteristics Additional characteristics may be listed, when they are considered necessary to specify adequately the component for design and application purposes. 1.3.4 Markinq The
33、 detail specification shall specify the content of the marking on the inductor and on the package. Deviations from 1.5 shall be specifically stated. 1.4 Terminoloav In addition to the applicable terms and definitions of CECC 29 O00 (EN 129 000:1993) the following definitions apply: 1.4.1 Surface mou
34、ntina inductor An inductor whose small dimensions and nature or shape of terminations make it suitable for surface mounting on hybrid circuits or printed boards. 1.4.2 Performance made 1 inductors (long life) Inductors for long-life applications with stringent: requirements for the electrical parame
35、ters. 1.4.3 Performance arade 2 inductors (general purpose) Inductors for general application, where the stringent require- ments for grade 1 inductors are not necessary. 1.4.4 Rated current (IR) The maximum r.m.s. value of the current, at which an inductor may be operated continuously at the rated
36、temperature. Note: The current may consist of d.c. current only, a.c. current only or of a combination of both. For testing purposes d.c. current is mandatory. High frequencies require a reduction of current in regard to temperature rise by magnetic and skin effect losses. 1.4.5 Incremental current
37、(IcR) That value of polarising direct current which when superimposed on the alternating measuring current will cause a reduction in measured inductance value of 10 %. BSI BS*EN*L27LOO 01 = I1624667 0571708 418 W Page 7 EN 129100 : 1993 1.5 Markinq 1.5.1 The information given in the marking is norma
38、lly selected from the following list; the relative importance of each item is indicated by its position in the list: 1) Rated inductance (in clear or code) 2) Tolerance on rated inductance 3) Manufacturers name or trade mark 4) Manufacturers type designation 5) Year and month (or week) of manufactur
39、e 6) Rated current 7) Climatic category 8) Reference to the detail specification 9) CECC Mark 1.5.2 When the detail specification requires marking the inductors shall be clearly marked with as many as possible of the above items as is considered useful. Any duplication of information in the marking
40、on the inductor should be avoided. If coded marking is applied, the codes as given in IEC xxx (at present 51(Sec)257) shall be used. 1.5.3 The package containing the inductor(s) shall be clearly marked with all the information listed in 1.5.1. 1.5.4 Any additional marking shall be so applied that no
41、 confusion can arise. BSI BS*EN*1291OO O1 = 1624669 0573709 354 Page 8 EN 12910 : 1993 SECTION 2 - PREFERRED RATINGS AND CHARACTERISTICS 2.1 Preferred climatic cateuories The inductors covered by this specification are classified into climatic categories according to the general rules given in IEC 6
42、8-1. The lower and upper category temperature and the duration of the damp heat, steady state test shall be chosen from the following: Lower category temperature: - 55 OC, - 40 OC, - 25 OC upper category temperature: + 85 OC, + 100 OC, + 125 OC and + 150 OC Duration of the damp heat, steady state te
43、st: 4, 10, 21 and 56 days - Note: With continuous operation at 125 OC in excess of the endurance test time, accelerated ageing has to be considered (see detail specification) . The severities for the cold and dry heat tests are the lower and the upper category temperatures respectively. 2.2 Preferre
44、d values of ratinas 2.2.1 Rated inductance (LR) Preferred values of rated inductance are: 1 - 1,2 - 1,5 - 1,s - 2,2 - 2,7 - 3,3 - 3,9 - 4,7 - 5,6 - 6,s - and 8,2 and their decimal multiples. These values conform to the E 12 series of preferred values given in IEC 63: Preferred number series for resi
45、stors and capacitors. 2.2.2 Tolerance on rated inductance The preferred tolerance on rated inductance is I 10 %. If other.tolerances are required they shall be preferably either f 5 % or f 20 %. BSI BS*EN*129100 O1 Lb24667 0571710 O76 Page 9 EN 129100 : 1993 2.2.3 Rated temperature (TR) The standard
46、 value of rated temperature is 85 OC. If derating or uprating of current is permitted, the relevant specification shall give guidance e.g. by an appropriate illustration as given below which is not subject to testing. TR TUC Tamb Figure 1: Permissible current verBus temperature I : load current IR :
47、 rated current Tamb: ambient temperature TR : rated temperature TUC : upper category temperature Page 10 EN 129100 : 1993 SECTION 3 - OUALITY ASSESSMENT PROCEDURES 3.1 Primarv staae of manufacture The primary stage of manufacture is the winding of the inductor element. 3.2 Structurallv similar comDo
48、nents Inductors considered as being structurally similar are inductors produced with similar processes and materials, though they may be of different sizes and inductance and current values. 3.3 Certified test records The information required in 3.5.1 of CECC 29 O00 shall be made available when pres
49、cribed in the detail specification and when requested by a purchaser. After the endurance test the parameters for which variables information is required are the inductance, Q, resonant frequency and the d.c. resistance. 3.4 Qualification approval The procedures for qualification approval testing are given in 3.4 of CECC 29 000. The schedule to be used for qualification approval testing on the basis of lot-by-lot and periodic tests is given in 3.5 of this specification. The procedure using a fixed sample size schedule is given in 3.4.1 and 3.