1、Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 13/12/2007 02:43, Uncontrolled Copy, (c) BSIg49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58l
2、iners Part 1: Requirements and test methods for sootfire resistanceThe European Standard EN 13063-1:2005, incorporating amendment A1:2007, has the status of a British StandardICS 91.060.40Chimneys System chimneys with clay/ceramic flue BRITISH STANDARDBS EN 13063-1:2005Incorporating amendment no. 1B
3、S EN 13063-1:2005Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 13/12/2007 02:43, Uncontrolled Copy, (c) BSIThis British Standard was published under the authority of the Standards Policy and Strategy Committee on 22 February 2006 BSI 2007ISBN 978 0 580 60205 4Amendments issued since publica
4、tionAmd. No. Date Comments17364 28 September 2007 Implementation of CEN amendment A1:2007This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard cannot confer immunity from legal ob
5、ligations.National forewordThis British Standard is the UK implementation of EN 13063-1:2005, incorporating amendment A1:2007.The UK participation in its preparation was entrusted by Technical Committee B/506, Chimneys, to Subcommittee B/506/3, Chimneys and their components having inner linings of c
6、lay or ceramic.A list of organizations represented on this subcommittee can be obtained on request to its secretary.EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 13063-1:2005+A1 July 2007 ICS 91.060.40 Supersedes EN 13063-1:2005 English Version Chimneys - System chimneys with clay/ceramic flu
7、e liners - Part 1: Requirements and test methods for sootfire resistance Conduits de fumes - Conduits-systmes avec conduit intrieur en terre cuite/cramique - Partie 1: Exigences et mthodes dessai relatives la dtermination de la rsistance au feu de chemine Abgasanlagen - System-Abgasanlagen mit Keram
8、ik-Innenrohren - Teil 1: Anforderungen und Prfungen fr Rubrandbestndigkeit This European Standard was approved by CEN on 2 September 2005 and includes Amendment 1 approved by CEN on 14 June 2007. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions
9、 for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exists in three off
10、icial versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austri
11、a, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMIT
12、TEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2007 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13063-1:2005+A1:2007: ELicensed Copy:
13、 Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 13/12/2007 02:43, Uncontrolled Copy, (c) BSIEN 13063-1:2005+A1:2007 (E) 2 Contents page Foreword4 1 Scope 5 2 Normative references 5 3 Terms and definitions .6 4 Shapes, dimensions and tolerances8 4.1 Flue liners .8 4.2 Insulation 8 4.3 Outer wall elements.9
14、4.4 Cleaning and inspection doors 9 5 Material requirements .9 5.1 General requirements for components .9 5.2 Safety in use.11 5.3 Hygiene, health and environment 12 5.4 Cleaning and inspection doors 12 5.5 Freeze/thaw resistance .13 5.6 Temperature classes .13 5.7 Pressure classes13 6 Replacement o
15、f single components of the system chimney 13 6.1 Change of flue liner .13 6.2 Change of opening sections.13 6.3 Change of insulation .14 6.4 Change of jointing materials for inner liners 14 6.5 Change of outer wall elements.14 6.6 Change of cleaning and inspection doors 14 7 Designation 14 8 Product
16、 information.15 9 Marking and labelling 16 10 Evaluation of conformity.16 10.1 General16 10.2 Components.16 10.3 Initial type testing of soot fire resistant system chimneys .17 10.4 Exchange of components .17 10.5 Factory production control.18 Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 1
17、3/12/2007 02:43, Uncontrolled Copy, (c) BSIEN 13063-1:2005+A1:2007 (E) 3 Annex A (normative) Test methods19 Annex B (normative) Stainless steel outer walls 25 Annex C (normative) Thermal resistance of the system chimney 26 Annex D (normative) Sampling procedures for an AQL of 10 % and inspection lev
18、el S227 Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU Construction Product Directive .31 Bibliography38 Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 13/12/2007 02:43, Uncontrolled Copy, (c) BSIEN 13063-1:2005+A1:2007 (E) 4 Foreword This docume
19、nt (EN 13063-1:2005+A1:2007) has been prepared by Technical Committee CEN/TC 166 “Chimneys”, the secretariat of which is held by UNI. This document shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by January 2008 and confli
20、cting national standards shall be withdrawn at the latest by April 2009. This document includes Amendment 1 approved by CEN on 2007-06-14. This document supersedes EN 13063-1:2005. The start and finish of text introduced or altered by amendment is indicated in the text by tags ! “. This European Sta
21、ndard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA which is an integral part of this document. This standard i
22、s part 1 of a series of standards for system chimneys with clay/ceramic flue liners. Part 2 is for system chimneys working under wet conditions and part 3 is for system air flue chimneys. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countri
23、es are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
24、 Sweden, Switzerland and United Kingdom. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 13/12/2007 02:43, Uncontrolled Copy, (c) BSIEN 13063-1:2005+A1:2007 (E) 5 1 Scope This European Standard specifies the requirements and test methods for multiwall soot fire resistant system chimneys, work
25、ing under dry conditions, with corrosion resistance 3, with negative pressure (see EN 1443) in which the products of combustion are conveyed to the atmosphere through clay/ceramic flue liners. Marking and inspection are also covered by this standard. This standard does not apply to structurally inde
26、pendent (free standing or self-supporting) system chimneys. A soot fire resistant system chimney has the following items where appropriate: clay/ceramic flue liners; Insulation layer; outer walls; mortar for jointing flue liners; mortar for jointing outer walls; terminal; chimney base; cladding; ope
27、ning section; cleaning and inspection door; distance piece; reinforcement. The soot fire resistant chimney covers a combination of compatible chimney components, obtained or specified from one manufacturing source with product responsibility for the whole chimney. 2 Normative references The followin
28、g referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 998-2:2003, Specification for mortar for masonry Part 2: M
29、asonry mortar EN 1366-8, Fire resistance tests for service installations Part 8: Smoke extraction ducts EN 1443:2003, Chimneys General requirements EN 1457:1999, Chimneys Clay/ceramic flue liners Requirements and test methods !EN 1806:2006“, Chimneys Clay/ceramic flue blocks for single wall chimneys
30、 Requirements and test methods Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 13/12/2007 02:43, Uncontrolled Copy, (c) BSIEN 13063-1:2005+A1:2007 (E) 6 EN 1859, Chimneys Metal chimneys Test methods EN 12446:2003, Chimneys Components Concrete outer wall elements EN 13069:2005, Chimneys Clay/c
31、eramic outer walls for system chimneys Requirements and test methods EN 13162:2001, Thermal insulation products for buildings Factory made mineral wool (MW) products Specification EN 13216-1:2004, Chimneys Test methods for system chimneys Part 1: General test methods EN 13384-1, Chimneys - Thermal a
32、nd fluid dynamic calculation methods Part 1: Chimneys serving one appliance !EN 13501-2, Fire classification of construction products and building elements Part 2: Classification using data from fire resistance tests, excluding ventilation services“ EN 14297:2004, Chimneys Freeze-thaw resistance tes
33、t method for chimney products EN ISO 1182, Reaction to fire tests for building products Non-combustibility test (ISO 1182:2002) ISO 2859-1, Sampling procedures for inspection by attributes Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection 3 Terms and defini
34、tions For the purposes of this European Standard, the terms and definitions given in EN 1443:2003 and EN 13216-1:2004 and the following apply. 3.1 soot fire resistant multiwall system chimney multiwall construction, consisting mainly of an outer wall, an insulation layer and a sootfire resistant inn
35、er clay/ceramic flue liner. The combination of these components forms a sootfire resistant system chimney (see Figure 1) Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 13/12/2007 02:43, Uncontrolled Copy, (c) BSIEN 13063-1:2005+A1:2007 (E) 7 Key 1 Inner liner 2 !Insulation layer (insulation
36、or air gap)“ 3 Outer wall 4 Cavities for back ventilation 5 Cavities for structural reinforcement Figure 1 Construction of a soot fire resistant system chimney 3.2 chimney base section of the system chimney, situated at the bottom, which comprises an inspection opening with door 3.3 reinforced outer
37、 wall outer wall having reinforcement to assist handling (not for structural stability) 3.4 structural reinforcement additional strengthening for structural stability (in the outer wall) 3.5 freeze-thaw-resistance ability of the product to resist the effects of freezing and thawing 3.6 opening secti
38、on flue liner which has an opening for cleaning and inspection or connection for another flue (junction) 3.7 cleaning and inspection door door in outer wall element to allow cleaning and inspection of the chimney. There are two types of cleaning and inspection doors (see Figure 2): - a cleaning and
39、inspection door combined with an opening section with inner door - a cleaning and inspection door combined with an opening section without inner door Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 13/12/2007 02:43, Uncontrolled Copy, (c) BSIEN 13063-1:2005+A1:2007 (E) 8 Key 1 Cleaning and in
40、spection door 2 Inner door of the opening section 3 Opening section 4 Insulation layer 5 Outer wall Figure 2 - Examples of cleaning and inspection doors and the opening sections 3.8 distance piece spacer to keep distance between outer wall element and insulation or inner liner 4 Shapes, dimensions a
41、nd tolerances 4.1 Flue liners 4.1.1 General Flue liners shall meet the requirements on size and tolerance of dimensions given in 7.1, 7.2, 7.3, 7.4, 7.5, 7.6 and 7.7 of EN 1457:1999. 4.1.2 External dimensions of flue liner When tested in accordance with A.2.6, the external dimensions of flue liners
42、measured on any cross section shall not deviate more than 3 % of the manufacturers stated nominal external dimensions. 4.2 Insulation The insulation layer shall meet the requirements on tolerance of dimensions given in 4.2.2 (length and width) and 4.2.3 (thickness class T3) of EN 13162:2001. License
43、d Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 13/12/2007 02:43, Uncontrolled Copy, (c) BSIEN 13063-1:2005+A1:2007 (E) 9 4.3 Outer wall elements Outer wall elements shall fulfil the requirements on shapes and tolerances on dimensions given in: concrete outer wall elements: EN 12446:2003, Clause 7 c
44、lay/ceramic outer walls: EN 13069:2005, Clause 6 metal outer walls: Annex B 4.4 Cleaning and inspection doors Dimensions and tolerances shall be declared by the manufacturer. 5 Material requirements 5.1 General requirements for components 5.1.1 General All components of soot fire resistant system ch
45、imneys shall be non combustible in accordance to EN ISO 1182. 5.1.2 Clay/ceramic flue liners Flue liners shall meet the requirements of EN 1457 clauses: 8.1 Straight flue liners (proof load); 8.3 Minimum load for inspection opening sections (proof load); 9.1 Initial test (gas tightness, thermal shoc
46、k resistance and resistance to fire for straight flue liners); 9.2 Final gas tightness after thermal shock testing; 10 Acid resistance; 11 Water absorption and bulk density; 12 Sweeping resistance. 5.1.3 Maximum compressive strength for opening sections When tested as described in A.2.3, components
47、shall withstand a load of at least five times the manufacturers declared design load. F = ( H G)/100 (1) where F = minimum load (kN); = safety factor = 5; H = height of chimney (m); Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 13/12/2007 02:43, Uncontrolled Copy, (c) BSIEN 13063-1:2005+A1:
48、2007 (E) 10 G = Weight per metre (kg/m). NOTE The limiting factor of the maximum height of system chimneys is the compressive strength of the opening section. 5.1.4 Jointing material for flue liners 5.1.4.1 Density The density of jointing material shall not vary more than 10 % of the manufacturer de
49、clared value when tested in accordance to A.2.2.2. 5.1.4.2 Compressive strength The compressive strength shall be at least 10 N/mmwhen tested according to A.2.2.3. 5.1.5 Insulation 5.1.5.1 General The insulation shall be to the manufacturers specifications and shall be prefabricated and have an independent permanent shape before and after being exposed to heat in operating conditions (e.g. blocks or bonded loose material). 5.1.5.2 Density The manufacturer shall