BS EN 50378-3-2-2007 Passive components to be used in optical fibre communication systems - Product specifications - Type 4 8 channel CWDM module terminated on IEC 60793-2-50 categ.pdf

上传人:ideacase155 文档编号:574887 上传时间:2018-12-13 格式:PDF 页数:26 大小:554.49KB
下载 相关 举报
BS EN 50378-3-2-2007 Passive components to be used in optical fibre communication systems - Product specifications - Type 4 8 channel CWDM module terminated on IEC 60793-2-50 categ.pdf_第1页
第1页 / 共26页
BS EN 50378-3-2-2007 Passive components to be used in optical fibre communication systems - Product specifications - Type 4 8 channel CWDM module terminated on IEC 60793-2-50 categ.pdf_第2页
第2页 / 共26页
BS EN 50378-3-2-2007 Passive components to be used in optical fibre communication systems - Product specifications - Type 4 8 channel CWDM module terminated on IEC 60793-2-50 categ.pdf_第3页
第3页 / 共26页
BS EN 50378-3-2-2007 Passive components to be used in optical fibre communication systems - Product specifications - Type 4 8 channel CWDM module terminated on IEC 60793-2-50 categ.pdf_第4页
第4页 / 共26页
BS EN 50378-3-2-2007 Passive components to be used in optical fibre communication systems - Product specifications - Type 4 8 channel CWDM module terminated on IEC 60793-2-50 categ.pdf_第5页
第5页 / 共26页
亲,该文档总共26页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、 g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58systems Product specifications Part 3-2: Type 4 / 8 channel CWDM module terminated on IEC 60793-2-5

2、0 category B1.1 and B1.3 single mode fibreThe European Standard EN 50378-3-2:2007 has the status of a British StandardICS 33.180.20Passive components to be used in optical fibre communication BRITISH STANDARDBS EN 50378-3-2:2007BS EN 50378-3-2:2007This British Standard was published under the author

3、ity of the Standards Policy and Strategy Committee on 28 September 2007 BSI 2007ISBN 978 0 580 57545 7Amendments issued since publicationAmd. No. Date Commentscontract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.

4、National forewordThis British Standard is the UK implementation of EN 50378-3-2:2007.The UK participation in its preparation was entrusted by Technical Committee GEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre optic interconnecting devices and passive components.A list of organizations represe

5、nted on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a EUROPEAN STANDARD EN 50378-3-2 NORME EUROPENNE EUROPISCHE NORM August 2007 CENELEC European Committee for Electrotechnical Standardization Comit Europen d

6、e Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2007 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50378-3-2:2007 E ICS 33.180.20 Engli

7、sh version Passive components to be used in optical fibre communication systems - Product specifications - Part 3-2: Type 4 / 8 channel CWDM module terminated on IEC 60793-2-50 category B1.1 and B1.3 single mode fibre Composants passifs destins tre utiliss dans des systmes de communication fibres op

8、tiques - Spcifications de produit - Partie 3-2: Modules CWDM type 4 / 8 canaux cbls sur fibres unimodales de catgories B1.1 et B1.3 de la CEI 60793-2-50 Passive Bauteile zur Verwendung in Lichtwellenleiter-Kommunikationssystemen - Produktnormen - Teil 3-2: Bauart 4-/8-Kanal-CWDM-Module zum Anschluss

9、 an Einmodenfasern der Kategorien B1.1 und B1.3 nach IEC 60793-2-50 This European Standard was approved by CENELEC on 2007-06-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national st

10、andard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any o

11、ther language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Rep

12、ublic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 50378-3-2:2007 - 2 - Foreword This European

13、 Standard was prepared by the Technical Committee CENELEC TC 86BXA, Fibre optic interconnect, passive and connectorised components. The text of the draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC as EN 50378-3-2 on 2007-06-01. The following dates were fixed: - late

14、st date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2008-06-01 - latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2010-06-01 _ - 3 - EN 50378-3-2:2007 Passive components

15、 to be used in optical fibre communication systems - Product specifications Part 3-2: Type 4 / 8 channel CWDM module terminated on IEC 60793-2-50 category B1.1 and B1.3 single mode fibre Description Performance Application: For use in uncontrolled environment EN 61753-1 Category U Attenuation Mux/De

16、mux: 4 channel / 8 channel -35 dBm/nm Source stability: 2 m. Only the fundamental mode shall propagate at the CWDM module to be tested and at the detector. 1 Attenuation Mux/Demux: 4 channel: -35 dBm/nm Source stability: 2 m. Only the fundamental mode shall propagate at the module to be tested and a

17、t the detector. 2 0,5dB-bandwidth Centred at the operating wavelength): 15 nm For the attenuation measurement the worst case insertion loss values are noted for each channel. The peak in the spectral response inside the OWR of the selected channel is determined. Looking up and down from the peak wav

18、elength, the wavelengths + and - are determined, where the filter transfer function drops below 0,5 dB for the first time. Pre-conditioning procedure: EN 50378-3-2:2007 - 12 - Table 2 - Optical performance requirements (continued) No. Test Requirement Details Method: EN 61300-3-7 Peak wavelength: Th

19、e operating wavelength band. Source stability: -35 dBm/nm Detector linearity: Within 0,05 dB over the dynamic range to be measured. Launch fibre length: 2 m. Only the fundamental mode shall propagate at the CWDM module to be tested and at the detector. Directional coupler: 50/50 Type: Fused. Directi

20、vity: 60 dB 3 Return Loss 45 dB Spectral width during the measurement is 10 nm. Every CWDM port is tested at the OWR of all channnels over a wavelength of: (1 260 1 625) nm for the universal grade or (1 460 1 625) nm for the SCL band grade Pre-conditioning procedure: Terminate non reflective all fib

21、res which are not measured Method: EN 61300-3-5 Source type: Unpolarised light, spectral density -35 dBm/nm wavelength: The operating wavelength band Launch fibre length 2 m. 4 Adjacent and non-Adjacent channel Isolation : 4 + 8 Channel Mux / Demux: Every CWDM port is tested at the OWR of all channe

22、ls over a wavelength of: (1 260 1 625) nm for the universal grade or (1 460 1 625) nm for the SCL band grade Adjacent 30 dB Non Adjacent 50 dB Pre-conditioning procedure: Terminate non reflective all fibres which are not measured Method: EN 61300-3-12; Peak wavelength: The operating wavelength band.

23、 Source stability: -35 dBm/nm - 13 - EN 50378-3-2:2007 Table 2 - Optical performance requirements (continued) No. Test Requirement Details Method: IEC 61300-3-5 Source type: Unpolarised light, spectral density -35 dBm/nm Wavelength: The operating wavelength band Launch fibre length 2 m. 6 Directivit

24、y (Bi directional Near end cross talk) Minimum directivity 50 dB Only applicable to bi-directional CWDMs. The wavelengths used for the transmit direction are all different from the receive wavelengths. The directivity shall be determined as the worst case over all states of polarization. The measure

25、ment shall be performed over the OWR of the chosen transmit port and shall be repeated for all transmit ports. Pre-conditioning procedure: Terminate non reflective all fibres which are not measured 7 Wavelength temperature sensitivity 30 dB - Non-adjacent channel isolation shall be: 50 dB - return l

26、oss shall be: 45 dB During the test the : - change of attenuation shall be: 0,40 dB - 0,5 dB Bandwidth 15 nm - Wavelength temp. sensitivity shall be : 0,005 nm/C Recovery Procedure: 2 h at normal ambient conditions - 17 - EN 50378-3-2:2007 Table 4 - Environmental performance requirements (continued)

27、 No. Test Requirement Details Method: EN 61300-2-46 High Temperature: + 55 C Low Temperature: + 25 C Duration of cycle: 24 h Specimen optically functioning: Yes Number of cycles: 6 Measurements required: Before, during and after the test. Pre-conditioning procedure: Clean plug and adaptor according

28、to manufacturers instructions. 16 Damp heat cyclic Attenuation Initial and final attenuation for Mux and Demux shall be: 4 channels: 2,3 dB 8 channels: 3,9 dB Change in attenuation during the test: 0,4 dB Return loss: 45 dB Recovery procedure: 2 h at normal ambient conditions. Method: EN 61300-2-27D

29、ust Type: Talc Dust particle size: d 150 m Dust Concentration: 10,6 g/m3 0,7 g/m3Temperature: +35 C Relative Humidity: 30 % Duration of exposure: 10 min Specimen optically functioning: No Measurements required: Before and after the test. 17 Dust Attenuation Initial and final attenuation for Mux and

30、Demux shall be: 4 channels: 2,3 dB 8 channels: 3,9 dB Return loss: 45 dB Recovery procedure: 2 h at normal ambient conditions. Method: EN 61300-2-26Atmosphere: Salt solution 5% NaCl pH 6,5-7,2 Temperature: +35 C Duration of exposure: 96 h. Specimen optically functioning: No Measurements required: Be

31、fore and after the test. 18 Salt mist Attenuation Initial and final attenuation for Mux and Demux shall be: 4 channels: 2,3 dB 8 channels: 3,9 dB Return loss: 45 dB Recovery procedure: 2 h at normal ambient conditions. EN 50378-3-2:2007 - 18 - Annex A (normative) Sample size and product sourcing req

32、uirements No. Test Sample size Source n/a Dimensional 4 New 1 Attenuation 4 New 2 0,5 dB-bandwidth 4 1 3 Return loss 4 2 4 Adjacent and non-adjacent channel Isolation 4 3 5 PDL 4 4 6 Directivity (bi directional near end crosstalk) 4 5 7 Wavelength temperature sensitivity 4 6 8 Vibration (sinusoidal)

33、 4 9 Fibre/cable retention 4 10 Impact 4 11 Static side load 4 12 Torsion 4 13 Cold 4 14 Dry heat 4 15 Change of temperature 4 16 Damp heat cyclic 4 17 Dust 4 18 Salt mist 4 The above tests are intended to be performed individually on product source as defined although product from a previous test m

34、ay be used if desired. Tests 1 to 7 must be performed on all samples used for Tests 8 to 18. - 19 - EN 50378-3-2:2007 Annex B (informative) ITU-T centre wavelengths G 694.2 1 270, 1 290, 1 310, 1 330, 1 350, 1 370, 1 390, 1 410, 1 430, 1 450, 1 470, 1 490, 1 510, 1 530, 1 550, 1 570, 1 590, 1 610 EN

35、 50378-3-2:2007 - 20 - Annex C (informative) Optical parameters and definitions Loss (in dB)Center wavelengths (in nm)iMaximuminsertion lossi+2i+1i-1i-20Adjacent channel IsolationPassbandNon-adjacentchannel IsolationBandwidthat 0.5 dB0.5 dBLoss (in dB)Loss (in dB)Figure C.1 - Passband, isolation, in

36、sertion loss, ripple and center wavelength C.1 operating passband specified range of wavelengths around operating center wavelength C.2 insertion loss maximum optical loss measured over operating passband C.3 adjacent channel isolation dB difference of maximum insertion loss in passband and minimum

37、loss over wavelength ranges of the adjacent passbands C.4 non-adjacent channel isolation dB difference of maximum insertion loss in passband and minimum loss over wavelength ranges of the non-adjacent passbands C.5 ripple maximum peak to peak variation of the insertion loss over the passband - 21 -

38、EN 50378-3-2:2007 Bibliography EN 60793-2-50 Optical fibres - Part 2-50: Product specifications - Sectional specification for class B single-mode fibres (IEC 60793-2-50) EN 60794-2 Optical fibre cables - Part 2: Indoor cables - Sectional specification (IEC 60794-2) EN 61300-2-1 Fibre optic interconn

39、ecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal) (IEC 61300-2-1) EN 61300-2-2 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-2: Tests Mating durability (IEC 61300-2-2)

40、 EN 61300-2-4 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests Fibre/cable retention (IEC 61300-2-4) EN 61300-2-5 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-5: Tests T

41、orsion/twist (IEC 61300-2-5) EN 61300-2-6 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-6: Tests Tensile strength of coupling mechanism (IEC 61300-2-6) EN 61300-2-7 Fibre optic interconnecting devices and passive components - Basic test a

42、nd measurement procedures - Part 2-7: Tests Bending moment (IEC 61300-2-7) EN 61300-2-12 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-12: Tests Impact (IEC 61300-2-12) EN 61300-2-17 Fibre optic interconnecting devices and passive compone

43、nts - Basic test and measurement procedures - Part 2-17: Tests Cold (IEC 61300-2-17) EN 61300-2-18 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-18: Tests Dry heat High temperature endurance (IEC 61300-2-18) EN 61300-2-19 Fibre optic inte

44、rconnecting devices and passive components - Basic test and measurement procedures - Part 2-19: Tests Damp heat (steady state) (IEC 61300-2-19) EN 61300-2-22 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests Change of temperature (I

45、EC 61300-2-22) EN 61300-2-26 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-26: Tests Salt mist (IEC 61300-2-26) EN 61300-2-27 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-27:

46、Tests Dust - Laminar flow (IEC 61300-2-27) EN 61300-2-42 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-42: Tests Static side load for connectors (IEC 61300-2-42) EN 61300-2-46 Fibre optic interconnecting devices and passive components - B

47、asic test and measurement procedures - Part 2-46: Tests Damp heat (cyclic) (IEC 61300-2-46) EN 50378-3-2:2007 - 22 - EN 61300-3-4 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-4: Examinations and measurements Attenuation (IEC 61300-3-4) E

48、N 61300-3-6 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements Return loss (IEC 61300-3-6) EN 61300-3-10 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part

49、 3-10: Examinations and measurements Gauge retention force (IEC 61300-3-10) EN 61300-3-34 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-34: Examinations and measurements Attenuation of random mated connectors (IEC 61300-3-34) EN 186000-1 Generic Specification: Connector sets for optical fibres and cables - Part 1: Requirements, test methods and qualification approval procedures bl

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有