BS EN 50491-5-2-2010 General requirements for home and building electronic systems (HBES) and building automation and control systems (BACS) - EMC requirements for HBES BACS used ir.pdf

上传人:rimleave225 文档编号:574976 上传时间:2018-12-13 格式:PDF 页数:18 大小:1.25MB
下载 相关 举报
BS EN 50491-5-2-2010 General requirements for home and building electronic systems (HBES) and building automation and control systems (BACS) - EMC requirements for HBES BACS used ir.pdf_第1页
第1页 / 共18页
BS EN 50491-5-2-2010 General requirements for home and building electronic systems (HBES) and building automation and control systems (BACS) - EMC requirements for HBES BACS used ir.pdf_第2页
第2页 / 共18页
BS EN 50491-5-2-2010 General requirements for home and building electronic systems (HBES) and building automation and control systems (BACS) - EMC requirements for HBES BACS used ir.pdf_第3页
第3页 / 共18页
BS EN 50491-5-2-2010 General requirements for home and building electronic systems (HBES) and building automation and control systems (BACS) - EMC requirements for HBES BACS used ir.pdf_第4页
第4页 / 共18页
BS EN 50491-5-2-2010 General requirements for home and building electronic systems (HBES) and building automation and control systems (BACS) - EMC requirements for HBES BACS used ir.pdf_第5页
第5页 / 共18页
亲,该文档总共18页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationGeneral requirements for Homeand Building Electronic Systems(HBES)and Building Automationand Control Systems (BACS)Part 5-2: EMC requirements for HBES/BACS used in residential, c

2、ommercial and light industry environmentBS EN 50491-5-2:2010National forewordThis British Standard is the UK implementation of EN 50491-5-2:2010.Together with BS EN 50491-3:2010, BS EN 50491-5-1:2010 and BS EN 50491-5-3:2010, it partially supersedes BS EN 50090-2-2:1996+A2:2007.The UK participation

3、in its preparation was entrusted to Technical CommitteeIST/6, Data communications.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions of acontract. Users are responsible for its cor

4、rect application. BSI 2010ISBN 978 0 580 64030 8ICS 97.120Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the StandardsPolicy and Strategy Committee on 31 July 2010.Amendments issued since publicationAmd. No.

5、Date Text affectedBRITISH STANDARDBS EN 50491-5-2:2010EUROPEAN STANDARD EN 50491-5-2 NORME EUROPENNE EUROPISCHE NORM April 2010 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management

6、Centre: Avenue Marnix 17, B - 1000 Brussels 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50491-5-2:2010 E ICS 97.120 Supersedes EN 50090-2-2:1996 (partially) + corr. Mar.1997 (partially) + A1:2002 (partially) + A2:2007 (pa

7、rtially) English version General requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) - Part 5-2: EMC requirements for HBES/BACS used in residential, commercial and light industry environment Exigences gnrales relatives aux systmes lectroniq

8、ues pour les foyers domestiques et les btiments (HBES) et aux Systmes de Gestion Technique du Btiment (SGTB) - Partie 5-2: Exigences CEM relatives aux HBES/SGTB destins tre utiliss en environnement de locaux rsidentiels, commerciaux et de petites industries Allgemeine Anforderungen an die Elektrisch

9、e Systemtechnik fr Heim und Gebude (ESHG) und an Systeme der Gebudeautomation (GA) - Teil 5-2: EMV-Anforderungen an ESHG/GA fr den Gebrauch in Wohnbereichen, Geschfts- und Gewerbebereichen sowie in Kleinbetrieben This European Standard was approved by CENELEC on 2010-04-01. CENELEC members are bound

10、 to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Cen

11、tral Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same s

12、tatus as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands

13、, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 50491-5-2:2010 2 Foreword This European Standard was prepared by a joint working group of CLC/TC 205, Home and Building Electronic Systems (HBES) and CEN/TC 247, Building Automation, Contro

14、ls and Building Management (BACS). It was submitted to the formal vote and was approved by CENELEC as EN 50491-5-2 on 2010-04-01. This standard supersedes the relevant parts of EN 50090-2-2:1996 1); it is referenced by CEN/TC 247 and CLC/TC 205. Attention is drawn to the possibility that some of the

15、 elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national sta

16、ndard or by endorsement (dop) 2011-04-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2013-04-01 As a result of the discussions at the CLC/TC 205 meeting on 2004-10-5/6 concerning the structuring of their standards in general parts and open system pa

17、rts (see CLC/TC 205/Sec0413/INF) the following new parts of EN 50491 under the generic title “General requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS)“ under the task of the JWG CEN/TC 247CLC/TC 205 are proposed: Part 2 Environmental con

18、ditions; Part 3 Electrical safety requirements; Part 4-1 2)Functional safety requirements (for non safety related systems); Part 4-2 2)Functional safety requirements (for safety related systems); Part 5-1 EMC requirements, conditions and test set-up; Part 5-2 EMC requirements for HBES/BACS used in r

19、esidential, commercial and light industry environment; Part 5-3 EMC requirements for HBES/BACS used in industry environment. This European Standard has been prepared under a mandate given to CENELEC by the European Commission and the European Free Trade Association and covers essential requirements

20、of EC Directive EMC Directive 2004/108/EC. See Annex ZZ. 1)EN 50090-2-2:1996 + Corr. Mar 1997 + A1:2002 + A2:2007, Home and Building Electronic Systems (HBES) Part 2-2: System overview General technical requirements 2)Under consideration. BS EN 50491-5-2:2010 3 EN 50491-5-2:2010 Contents Introductio

21、n . 4 1 Scope . 5 2 Normative references . 5 3 Terms, definitions and abbreviations . 5 4 General requirements . 6 5 Performance criteria . 6 6 Standard test conditions 6 7 EMC requirements 7 7.1 Immunity requirements . 7 7.2 Emission requirements .11 Annex ZZ (informative) Coverage of Essential Req

22、uirements of EC Directives 12 Bibliography 13 Tables Table 1 EMC immunity requirements for enclosure . 7 Table 2 EMC immunity requirements for HBES/BACS network port . 8 Table 3 EMC immunity requirements for signal port 9 Table 4 EMC immunity requirements for DC power ports 10 Table 5 EMC immunity r

23、equirements for AC power ports 11 BS EN 50491-5-2:2010EN 50491-5-2:2010 4 Introduction EN 50491 series deals with developing and testing Home and Building Electronic Systems (HBES) and Building Automation and Control System (BACS). The expression HBES/BACS covers any combination of HBES and/or BACS

24、products including their separate connected/detachable devices linked together via one or more networks. Part 5 of this series applies to HBES/BACS devices to ensure a common level of EMC requirements. BS EN 50491-5-2:2010 5 EN 50491-5-2:2010 1 Scope The scope of EN 50491-5-1:2010 applies, with the

25、following modification: Replace the 3rdparagraph by the following ones: This is the specific part of EN 50491-5 for HBES/BACS used in residential, commercial and light industry environment. The environments covered by this standard are residential, commercial and light-industrial locations, accordin

26、g to the definition in EN 61000-6-1. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments

27、) applies. EN 50491-5-1 General requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) Part 5-1: EMC requirements, conditions and test set-up EN 61000-4-2 Electromagnetic compatibility (EMC) Part 4-2: Testing and measurement techniques Electro

28、static discharge immunity test (IEC 61000-4-2) EN 61000-4-3 Electromagnetic compatibility (EMC) Part 4-3: Testing and measurement techniques Radiated, radio-frequency, electromagnetic field immunity test (IEC 61000-4-3) EN 61000-4-4 Electromagnetic compatibility (EMC) Part 4-4: Testing and measureme

29、nt techniques Electrical fast transient/burst immunity test (IEC 61000-4-4) EN 61000-4-5 Electromagnetic compatibility (EMC) Part 4-5: Testing and measurement techniques Surge immunity test (IEC 61000-4-5) EN 61000-4-6 Electromagnetic compatibility (EMC) Part 4-6: Testing and measurement techniques

30、Immunity to conducted disturbances, induced by radio-frequency fields (IEC 61000-4-6) EN 61000-4-8 Electromagnetic compatibility (EMC) Part 4-8: Testing and measurement techniques Power frequency magnetic field immunity test (IEC 61000-4-8) EN 61000-4-11 Electromagnetic compatibility (EMC) Part 4-11

31、: Testing and measurement techniques Voltage dips, short interruptions and voltage variations immunity tests (IEC 61000-4-11) EN 61000-6-1 Electromagnetic compatibility (EMC) Part 6-1: Generic standards Immunity for residential, commercial and light-industrial environments (IEC 61000-6-1) EN 61000-6

32、-3 Electromagnetic compatibility (EMC) Part 6-3: Generic standards Emission standard for residential, commercial and light-industrial environments (IEC 61000-6-3) 3 Terms, definitions and abbreviations For the purposes of this document, the terms, definitions and abbreviations given in EN 50491-5-1:

33、2010 apply. BS EN 50491-5-2:2010EN 50491-5-2:2010 6 4 General requirements The general requirements of EN 50491-5-1:2010 apply. 5 Performance criteria The performance criteria of EN 50491-5-1:2010 apply. 6 Standard test conditions The standard test conditions of EN 50491-5-1:2010 apply. BS EN 50491-

34、5-2:2010 7 EN 50491-5-2:2010 7 EMC requirements 7.1 Immunity requirements 7.1.1 Enclosure Table 1 EMC immunity requirements for enclosure Phenomenon Basic standard Test specification Performance criterion Remarks Power-frequency magnetic fields EN 61000-4-8 50/60 Hz 3 A/m A a,b,cRadio-frequency elec

35、tromagnetic field Amplitude modulated EN 61000-4-3 d (80 to 1 000) MHz 80 % AM (1 kHz) 3 V/m 10 V/m A B g e,fRadio-frequency electromagnetic field Amplitude modulated EN 61000-4-3 d (1,4 to 2,0) GHz 80 % AM (1 kHz) 3 V/m eA hRadio-frequency electromagnetic field Amplitude modulated EN 61000-4-3 d (2

36、,0 to 2,7) GHz 80 % AM (1 kHz) 1 V/m A e,hElectrostatic discharge EN 61000-4-2 4 kV (contact) 8 kV (air) B B ia The test shall be carried out at the frequencies appropriate to the power supply frequency. Equipment intended for use in areas supplied only at one of these frequencies need only be teste

37、d at that frequency. bApplicable only to apparatus containing devices susceptible to magnetic fields. cFor CRTs, the acceptable jitter depends upon the character size and is calculated for a test level of 1 A/m as follows: ()4013 +=CJwhere jitter J and character size C are in millimetres. As jitter

38、is linearly proportional to the magnetic field strength, tests can be carried out at other test levels extrapolating the maximum jitter level appropriately. dEN 61000-4-20 may be used for small EUTs as defined in EN 61000-4-20:2003, 6.1. eThe test level specified is the r.m.s. value of the unmodulat

39、ed carrier. fIf the test is passed with the higher level and performance criteria A the test for the lower level is not necessary. gExcept for the ITU broadcast frequency bands 87 MHz to 108 MHz, 174 MHz to 230 MHz and 470 MHz to 790 MHz, where the level shall be 3 V/m and the performance criteria A

40、. hThe frequency range has been selected to cover the frequencies with the highest potential risk of disturbance. iSee basic standard for applicability of contact and/or air discharge tests. BS EN 50491-5-2:2010EN 50491-5-2:2010 8 7.1.2 HBES/BACS network port Table 2 EMC immunity requirements for HB

41、ES/BACS network port Phenomenon Basic standard Test specification Performance criterion Remarks Radio-frequency common mode EN 61000-4-6 (0,15 to 80) MHz 80 % AM (1 kHz) 3 V 10 V A B b a,c,d,e Fast transients (bursts) EN 61000-4-4 Tr/Th 5/50 ns 5 kHz Repetition 0,5 kV 1 kV A B c,eCapacitive clamp us

42、ed Transients (surge) Line to earth Line to line - balanced transmission - unbalanced transmission EN 61000-4-5 Tr/Th 1,2/50(8/20) s 2 kV No test 1 kV B B f,ga The test level can also be defined as the equivalent current into a 150 load. b Except for the ITU broadcast frequency band 47 MHz to 68 MHz

43、, where the level shall be 3 V and the performance criteria A. c Applicable only to communication interfaces with cables whose total length according to the manufacturers functional specification may exceed 3 m. d The test level specified is the r.m.s. value of the unmodulated carrier. e If the test

44、 is passed with the higher level and performance criteria A the test for the lower level is not necessary. f Applicable only to communication interfaces with cables whose total length according to the manufacturers functional specification may exceed 30 m. g Where normal functioning cannot be achiev

45、ed because of the impact of the CDN on the EUT, this test is not required. BS EN 50491-5-2:2010 9 EN 50491-5-2:2010 7.1.3 Signal port Table 3 EMC immunity requirements for signal port Phenomenon Basic standard Test specification Performance criterion Remarks Radio-frequency common mode EN 61000-4-6

46、(0,15 to 80) MHz 80 % AM (1 kHz) 3 V 10 V A B ba,c,d,eFast transients (bursts) EN 61000-4-4 Tr/Th 5/50 ns 5 kHz Repetition 0,5 kV 1 kV A B c,e Capacitive clamp used Transients (surge) Line to earth Line to line - balanced transmission - unbalanced transmission EN 61000-4-5 Tr/Th 1,2/50(8/20) s 2 kV

47、No test 0,5 kV B f B ga The test level can also be defined as the equivalent current into a 150 load. b Except for the ITU broadcast frequency band 47 MHz to 68 MHz, where the level shall be 3 V and the performance criteria A. c Applicable only to communication interfaces with cables whose total len

48、gth according to the manufacturers functional specification may exceed 3 m. d The test level specified is the r.m.s. value of the unmodulated carrier. e If the test is passed with the higher level and performance criteria A the test for the lower level is not necessary. f Applicable only to communic

49、ation interfaces with cables whose total length according to the manufacturers functional specification may exceed 30 m. g Where normal functioning cannot be achieved because of the impact of the CDN on the EUT, this test is not required. BS EN 50491-5-2:2010EN 50491-5-2:2010 10 7.1.4 DC power ports Table 4 EMC immunity requirements for DC power ports Phenomenon Basic standard Test specification Performance criterio

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf