1、Hollow metallic waveguidesPart 2: Relevant specifications for ordinary rectangular waveguidesBS EN 60153-2:2016Incorporating corrigendum February 2017(IEC 60153-2:2016)BSI Standards PublicationBS EN 60153-2:2016 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 60
2、153-2:2016, incorporating corrigendum February 2017. It is identical to IEC 60153-2:2016.The UK participation in its preparation was entrusted to Technical Committee EPL/46, Cables, wires and waveguides, radio frequency connectors and accessories for communication and signalling.A list of organizati
3、ons represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2017. Published by BSI Standards Limited 2017ISB
4、N 978 0 580 97921 7ICS 33.120.10Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 September 2016.Amendments/corrigenda issued since publicationDate Text affecte
5、d31 March 2017 Implementation of CENELEC corrigendum February 2017: Supersession details added to CENELEC cover page and forewordEUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 60153-2 September 2016 ICS 33.120.10 English Version Hollow metallic waveguides - Part 2: Relevant specifications for
6、ordinary rectangular waveguides (IEC 60153-2:2016) Guides dondes mtalliques creux - Partie 2: Spcifications applicables relatives aux guides dondes rectangulaires normaux (IEC 60153-2:2016) Metallische Hohlleiter - Teil 2: Einzelbestimmungen fr normale Rechteckhohlleiter (IEC 60153-2:2016) This Euro
7、pean Standard was approved by CENELEC on 2016-06-22. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical reference
8、s concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN
9、ELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugosla
10、v Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standar
11、dization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 60153-2:
12、2016 EBS EN 60153-2:2016Supersedes HD 123.2 S1:1977 2 EN 60153-2:2016 European foreword The text of document 46F/303/CDV, future edition 3 of IEC 60153-2, prepared by SC 46F “RF and microwave passive components“, of IEC/TC 46 “Cables, wires, waveguides, RF connectors, RF and microwave passive compon
13、ents and accessories“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 60153-2:2016. BS EN 60153-2:2016g120 latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2017-03-22 g120 l
14、atest date by which the national standards conflicting with the document have to be withdrawn (dow) 2019-06-22 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or
15、 all such patent rights. Endorsement notice The text of the International Standard IEC 60153-2:2016 was approved by CENELEC as a European Standard without any modification. This document supersedes HD 123.2 S1:1977.EN 60153-2:2016 3 Annex ZA (normative) Normative references to international publicat
16、ions with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced
17、document (including any amendments) applies. NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here: www.
18、cenelec.eu. Publication Year Title EN/HD Year IEC 60050 series International Electrotechnical Vocabulary (IEV) - - IEC 60153-1 2016 Hollow metallic waveguides - Part 1: General requirements and measuring methods EN 60153-1 2016 IEC 60261 - Sealing test for pressurized waveguide tubing and assemblies
19、 HD 138 S2 - BS EN 60153-2:2016 2 IEC 60153-2:2016 IEC 2016 CONTENTS FOREWORD . 3 INTRODUCTION . 5 1 Scope 6 2 Normative references. 6 3 Terms and definitions 6 4 General . 6 4.1 Standardized types . 6 4.2 Type designation . 6 4.3 Frequency range . 7 5 Mechanical requirements . 7 5.1 General . 7 5.2
20、 Dimensions . 7 5.2.1 General . 7 5.2.2 Inside dimensions 7 5.2.3 Wall thickness 8 5.2.4 Eccentricity 8 5.2.5 Outside dimensions 8 5.2.6 Rectangularity of cross-section . 8 5.3 Other mechanical requirements . 9 5.3.1 Bow . 9 5.3.2 Twist 10 5.3.3 Surface roughness . 10 5.3.4 Internal stresses 10 5.4
21、Electrical tests 10 5.4.1 Attenuation 10 5.5 Additional tests Gas tightness . 11 Table 1 Deviation of aperture dimension . 7 Table 2 Deviation of outside dimensions . 8 Table 3 Specification and attenuation constants (informative) . 12 BS EN 60153-2:2016IEC 60153-2:2016 IEC 2016 3 INTERNATIONAL ELEC
22、TROTECHNICAL COMMISSION _ HOLLOW METALLIC WAVEGUIDES Part 2: Relevant specifications for ordinary rectangular waveguides FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National C
23、ommittees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Av
24、ailable Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental
25、organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on techni
26、cal matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC
27、 National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniform
28、ity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IE
29、C itself does not provide any attestation of conformity. Independent certification bodies provide conformity assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any services carried out by independent certification bodies. 6) All users should ensure
30、that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any
31、nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use of the refere
32、nced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. Interna
33、tional Standard IEC 60153-2 has been prepared by subcommittee 46F: RF and microwave passive components, of IEC technical committee 46: Cables, wires, waveguides, RF connectors, RF and microwave passive components and accessories. This third edition cancels and replaces the second edition published i
34、n 1974. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) expand and revise the operation frequency range for waveguides; b) revise the allowance of aperture dimensions; c) revise the test method
35、for aperture dimensions; d) revise the equation of attenuation. BS EN 60153-2:2016 4 IEC 60153-2:2016 IEC 2016 The text of this standard is based on the following documents: CDV Report on voting 46F/303/CDV 46F/317/RVCFull information on the voting for the approval of this standard can be found in t
36、he report on voting indicated in the above table. This publication has been drafted in accordance with the ISO/IEC Directives, Part 2. A list of all parts in the IEC 60153 series, published under the general title Hollow metallic waveguides, can be found on the IEC website. The committee has decided
37、 that the contents of this publication will remain unchanged until the stability date indicated on the IEC website under “http:/webstore.iec.ch“ in the data related to the specific publication. At this date, the publication will be g120 reconfirmed, g120 withdrawn, g120 replaced by a revised edition
38、, or g120 amended. IMPORTANT The colour inside logo on the cover page of this publication indicates that it contains colours which are considered to be useful for the correct understanding of its contents. Users should therefore print this document using a colour printer. BS EN 60153-2:2016IEC 60153
39、-2:2016 IEC 2016 5 INTRODUCTION This International Standard relates to straight hollow metallic tubing for use as waveguides in electronic equipment. In recent year the operation frequency of waveguide components and system has been extended to 1 THz and above. However, the first edition of the IEC
40、60153 series of standards only specified the aperture dimensions for ordinary rectangular waveguide for frequencies up to 325 GHz. In addition, the first edition of the IEC 60153 series of standards, dating from the 1960s, does not cover current applications. This new edition of IEC 60153-2 addresse
41、s these two issues by extending the frequency coverage to 3 300 GHz and by addressing current applications for this type of waveguide. BS EN 60153-2:2016 6 IEC 60153-2:2016 IEC 2016 HOLLOW METALLIC WAVEGUIDES Part 2: Relevant specifications for ordinary rectangular waveguides 1 Scope This part of IE
42、C 60153 specifies straight hollow metallic tubing of ordinary rectangular waveguide for use as waveguides in electronic equipment. The aim of this standard is to specify for hollow metallic waveguides: a) the details necessary to ensure compatibility and, as far as essential, interchangeability; b)
43、test methods; c) uniform requirements for the electrical and mechanical properties. It should be noted that no recommendations are made for the materials to be used for waveguides. The choice of material is agreed between customer and manufacturer. This document should be read in conjunction with IE
44、C 60153-1, which gives general requirements and test methods. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the
45、latest edition of the referenced document (including any amendments) applies. IEC 60050 (all parts), International Electrotechnical Vocabulary (available at g31http:/www.electropedia.org/) IEC 60153-1:2016, Hollow metallic waveguides General requirements and measuring methods IEC 60261, Sealing test
46、 for pressurized waveguide tubing and assemblies 3 Terms and definitions For the purposes of this document, the terms and definitions given in IEC 60050-726 apply. 4 General 4.1 Standardized types The series of ordinary rectangular waveguides covered by this publication are shown in Table 1. 4.2 Typ
47、e designation For these waveguides, the type designation comprises: a) the code: 60153 IEC-R BS EN 60153-2:2016IEC 60153-2:2016 IEC 2016 7 b) a number characterizing a particular size of waveguide. This number expresses approximately in multiples of 100 MHz the geometric mean frequency of the recomm
48、ended frequency range; c) if the symbol “K” is being used to indicate a factor of 1 000 (which it is suspected that it is), then the symbol needs to be in lower case (i.e. “k”), which stands for “kilo” in the SI system. This affects many waveguide names given in Table 3 and elsewhere in this standar
49、d. Example: “60153 IEC-R 100“ denotes a 22,860 mm g117 10,160 mm (0,900 in g117 0,400 in) ordinary rectangular waveguide for general purposes with a centre frequency of approximately 10 GHz in the dominant mode. 4.3 Frequency range The frequency range indicated in Table 1 is from approximately 1,25 to 1,9 times the cut-off frequency in the dominant mode. For any particular type of application, the working frequency range may be smaller or greater than the frequency range given in the table. 5 Mechanical requirem