1、BRITISH STANDARDBS EN 60512-15-4:2008Connectors for electronic equipment Tests and measurements Part 15-4: Connector tests (mechanical) Test 15d: Contact insertion, release and extraction force ICS 31.220.10g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g
2、49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 60512-15-4:2008This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 September 2008 BSI 2008ISBN 978 0 580 55902 0National forewordT
3、his British Standard is the UK implementation of EN 60512-15-4:2008. It is identical to IEC 60512-15-4:2008.The UK participation in its preparation was entrusted to Technical Committee EPL/48, Electromechanical components and mechanical structures for electronic equipment.A list of organizations rep
4、resented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Amendment
5、s/corrigenda issued since publicationDate CommentsEUROPEAN STANDARD EN 60512-15-4 NORME EUROPENNE EUROPISCHE NORM July 2008 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secreta
6、riat: rue de Stassart 35, B - 1050 Brussels 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60512-15-4:2008 E ICS 31.220.10 English version Connectors for electronic equipment - Tests and measurements - Part 15-4: Connector t
7、ests (mechanical) - Test 15d: Contact insertion, release and extraction force (IEC 60512-15-4:2008) Connecteurs pour quipements lectroniques - Essais et mesures - Partie 15-4: Essais (mcaniques) des connecteurs - Essai 15d: Force dinsertion, de dverrouillage et dextraction des contacts (CEI 60512-15
8、-4:2008) Steckverbinder fr elektronische Einrichtungen - Mess- und Prfverfahren - Teil 15-4: Mechanische Prfungen an Steckverbindern - Prfung 15d: Kontakteinsetz- und -lsekraft (IEC 60512-15-4:2008) This European Standard was approved by CENELEC on 2008-07-01. CENELEC members are bound to comply wit
9、h the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretari
10、at or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the o
11、fficial versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portu
12、gal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Foreword The text of document 48B/1846/FDIS, future edition 1 of IEC 60512-15-4, prepared by SC 48B, Connectors, of IEC TC 48, Electromechanical components and mechanical structures for electronic equipment, was sub
13、mitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60512-15-4 on 2008-07-01. This standard is to be read in conjunction with EN 60512-1 and EN 60512-1-100 which explains the structure of the EN 60512 series. The following dates were fixed: latest date by which the EN has to be
14、 implemented at national level by publication of an identical national standard or by endorsement (dop) 2009-04-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2011-07-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the Intern
15、ational Standard IEC 60512-15-4:2008 was approved by CENELEC as a European Standard without any modification. _ BS EN 60512-15-4:2008 2 CONNECTORS FOR ELECTRONIC EQUIPMENT TESTS AND MEASUREMENTS Part 15-4: Connector tests (mechanical) Test 15d: Contact insertion, release and extraction force 1 Scope
16、 and object This part of IEC 60512, when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this document is to detail a standard test method
17、to determine the forces required to insert contact into, and extract them from, their normal position in the intended connector. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For
18、 undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60512-1-1, Connectors for electronic equipment Tests and measurements Part 1-1: General examination Test 1a: Visual examination 3 Preparations 3.1 Preparation of specimen The specimen shall con
19、sist of a connector with its terminations, wired as specified in the detail specification. Any accessories, which do not form part of the contact system, may be removed. Any preconditioning given in the detail specification shall be applied. Any contact retention device shall be placed in such a pos
20、ition as not to influence the test, except where the use of such devices is part of the normal insertion and extraction process. All contacts shall be installed except for those to be used for the test. 3.2 Lubricant or sealing substance For the application and measurement of the forces a suitable d
21、evice able to provide the controls on the loads shall be required (e.g.: a universal materials testing machine). NOTE If the detail specification requires special preconditioning of the specimen, all the necessary equipment detailed in the relevant documents describing such conditioning would also b
22、e required. 3.3 Equipment Insertion and extraction tools, when specified by the detail specification, shall be provided. 3.4 Mounting If mounting of the specimen is appropriate, it shall be as specified in the detail specification. BS EN 60512-15-4:2008 3 4 Test method 4.1 Procedure Unless otherwise
23、 stated in the detail specification, 3 connectors shall be tested. 4.1.1 Selection of contact for test 20 % of the contacts, but not less than 6, shall be selected at random provided that at least one contact is near the periphery, and one near the centre of the connector. For connectors having six
24、or less contacts, all contacts shall be used. 4.1.2 Insertion A contact shall be inserted into its cavity using the insertion tool, lubricant and any other aid specified in the detail specification. Instructions for this procedure given, or referred to, in the detail specification, shall be followed
25、. It shall be ascertained that the contacts are in the intended position and are latched or locked into place. The foregoing procedure shall be applied to the selected contacts in turn. 4.1.3 Extraction In a similar manner to the insertion, the selected contacts shall be removed. In the case of non-
26、removable contacts, this part of the test shall not apply. 4.1.4 Repeated insertion and extraction The foregoing constitutes one insertion and extraction cycle. If specified in the detail specification, it shall be repeated a specified number of times. 4.2 Measurements 4.2.1 Before testing Visual ex
27、amination according to IEC 60512-1-1 shall be done. 4.2.2 During testing The forces required to achieve insertion and extraction (release) of the contact shall be measured and recorded. The insertion and extraction forces shall not exceed those given in the detail specification. 4.2.3 After testing
28、Visual examination according to IEC 60512-1-1 shall be done. 5 Details to be specified When this test is required by a detail specification, the following shall be given therein: a) the number of connectors to test if other than 3; b) preconditioning required; c) wiring of the specimen; d) mounting
29、of the specimen, if required; e) specification and application method of any lubricant or sealant to be used; BS EN 60512-15-4:2008 4 f) maximum insertion and extraction forces; g) number of insertion and extraction, if other than one; h) if the contact is non-removable; i) any deviation from the st
30、andard test method. _ BS EN 60512-15-4:2008 5 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited
31、 applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60512-1-1 -1)Con
32、nectors for electronic equipment - Tests and measurements - Part 1-1: General examination - Test 1a: Visual examination EN 60512-1-1 20022)1)Undated reference. 2)Valid edition at date of issue. BS EN 60512-15-4:2008 6 blankBS EN 60512-15-4:2008BSI Group Headquarters389 Chiswick High Road,London W4 4
33、AL, UKTel +44 (0)20 8996 9001Fax +44 (0)20 8996 Standards Institution (BSI)BSI is the independent national body responsible for preparing British Standards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter.RevisionsBritish Standards
34、are updated by amendment or revision. Users of British Standards should make sure that they possess the latest amendments or editions.It is the constant aim of BSI to improve the quality of our products and services. We would be grateful if anyone finding an inaccuracy or ambiguity while using this
35、British Standard would inform the Secretary of the technical committee responsible, the identity of which can be found on the inside front cover. Tel: +44 (0)20 8996 9000 Fax: +44 (0)20 8996 7400BSI offers members an individual updating service called PLUS which ensures that subscribers automaticall
36、y receive the latest editions of standards.Buying standardsOrders for all BSI, international and foreign standards publications should be addressed to Customer Services. Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001 Email: You may also buy directly using a debit/credit card from the BSI Shop on
37、the Website http:/ response to orders for international standards, it is BSI policy to supply the BSI implementation of those that have been published as British Standards, unless otherwise requested.Information on standardsBSI provides a wide range of information on national, European and internati
38、onal standards through its Library and its Technical Help to Exporters Service. Various BSI electronic information services are also available which give details on all its products and services. Contact the Information Centre. Tel: +44 (0)20 8996 7111 Fax: +44 (0)20 8996 7048 Email: Subscribing mem
39、bers of BSI are kept up to date with standards developments and receive substantial discounts on the purchase price of standards. For details of these and other benefits contact Membership Administration. Tel: +44 (0)20 8996 7002 Fax: +44 (0)20 8996 7001 Email: Information regarding online access to
40、 British Standards via British Standards Online can be found at http:/ information about BSI is available on the BSI website at http:/.CopyrightCopyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of the publications of the international standardization bodies. Except
41、 as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means electronic, photocopying, recording or otherwise without prior written permission from BSI. This does not preclude the free use, in th
42、e course of implementing the standard, of necessary details such as symbols, and size, type or grade designations. If these details are to be used for any other purpose than implementation then the prior written permission of BSI must be obtained. Details and advice can be obtained from the Copyright & Licensing Manager. Tel: +44 (0)20 8996 7070 Email: