BS EN 61169-2-2007 Radio-frequency connectors - Sectional specification - Radio frequency coaxial connectors of type 9 52《射频连接器 分规范 9 52型射频同轴连接器》.pdf

上传人:figureissue185 文档编号:577007 上传时间:2018-12-13 格式:PDF 页数:24 大小:426.88KB
下载 相关 举报
BS EN 61169-2-2007 Radio-frequency connectors - Sectional specification - Radio frequency coaxial connectors of type 9 52《射频连接器 分规范 9 52型射频同轴连接器》.pdf_第1页
第1页 / 共24页
BS EN 61169-2-2007 Radio-frequency connectors - Sectional specification - Radio frequency coaxial connectors of type 9 52《射频连接器 分规范 9 52型射频同轴连接器》.pdf_第2页
第2页 / 共24页
BS EN 61169-2-2007 Radio-frequency connectors - Sectional specification - Radio frequency coaxial connectors of type 9 52《射频连接器 分规范 9 52型射频同轴连接器》.pdf_第3页
第3页 / 共24页
BS EN 61169-2-2007 Radio-frequency connectors - Sectional specification - Radio frequency coaxial connectors of type 9 52《射频连接器 分规范 9 52型射频同轴连接器》.pdf_第4页
第4页 / 共24页
BS EN 61169-2-2007 Radio-frequency connectors - Sectional specification - Radio frequency coaxial connectors of type 9 52《射频连接器 分规范 9 52型射频同轴连接器》.pdf_第5页
第5页 / 共24页
亲,该文档总共24页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、 g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58Radio frequency coaxial connectors of type 9,52The European Standard EN 61169-2:2007 has the status

2、 of a British StandardICS 31.220.10Radio-frequency connectors Part 2: Sectional specification BRITISH STANDARDBS EN 61169-2:2007BS EN 61169-2:2007This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 May 2007 BSI 2007ISBN 978 0 580 50821 9Amendm

3、ents issued since publicationAmd. No. Date CommentsA list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance w

4、ith a British Standard cannot confer immunity from legal obligations.National forewordThis British Standard was published by BSI. It is the UK implementation of EN 61169-2:2007. It is identical with IEC 61169-2:2007. It supersedes BS EN 61169-2:2002 which is withdrawn. The UK participation in its pr

5、eparation was entrusted by Technical Committee EPL/46, Cables, wires and waveguides, radio frequency connectors and accessories for communication and signalling, to Subcommittee EPL/46/2, Radio frequency connectors and waveguides.EUROPEAN STANDARD EN 61169-2 NORME EUROPENNE EUROPISCHE NORM March 200

6、7 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2007 CENELEC - All rights of exploitation in any form and by any means reserve

7、d worldwide for CENELEC members. Ref. No. EN 61169-2:2007 E ICS 31.220.10 Supersedes EN 61169-2:2001English version Radio-frequency connectors - Part 2: Sectional specification - Radio frequency coaxial connectors of type 9,52 (IEC 61169-2:2007) Connecteurs pour frquences radiolectriques - Partie 2:

8、 Spcification intermdiaire - Connecteurs pour frquences radiolectriques de srie 9,52 (CEI 61169-2:2007) Hochfrequenz-Steckverbinder - Teil 2: Rahmenspezifikation - Koaxiale Hochfrequenzsteckverbinder Typ 9,52 (IEC 61169-2:2007) This European Standard was approved by CENELEC on 2007-03-01. CENELEC me

9、mbers are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on applica

10、tion to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat

11、 has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Nethe

12、rlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Foreword The text of document 46F/56/FDIS, future edition 2 of IEC 61169-2, prepared by SC 46F, R.F. and microwave passive components, of IEC TC 46, Cables, wires, waveguides, R.F. conne

13、ctors, R.F. and microwave passive components and accessories, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61169-2 on 2007-03-01. This European Standard supersedes EN 61169-2:2001. The main change introduced in EN 61169-2:2007 is that the maximum frequency is now

14、3 GHz. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2007-12-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2010-03-01 Ann

15、ex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 61169-2:2007 was approved by CENELEC as a European Standard without any modification. _ 2 EN 61169-2:2007CONTENTS 1 Scope.4 2 Normative references .4 3 Interface dimensions 4 3.1 Interface4 3.2 Mechanica

16、l gauges8 4 Quality assessment procedures9 4.1 General .9 4.2 Ratings and characteristics .9 4.3 Test schedule and inspection requirements .11 4.4 Procedures13 5 Instructions for preparation of detail specifications .13 5.1 General .13 5.2 Identification of the detail specification 13 5.3 Identifica

17、tion of the component14 5.4 Performance14 5.5 Marking, ordering information and related matters.14 5.6 Selection of tests, test conditions and severities14 5.7 Blank detail specification pro-forma for type 9,52 connector 15 Figure 1a Sliding male connector.5 Figure 1b Sliding female connector 5 Figu

18、re 1 Sliding connector .5 Figure 2a Screw coupling male connector6 Figure 2b Screw coupling female connector .6 Figure 2 Screw coupling connector 6 Figure 3a Standard test male connector.7Figure 3b Standard test female connector7 Figure 3 Standard test connectors .7 Figure 4 Gauge pins for outer con

19、tact of socket connector.8 Figure 5 Gauge pins for centre contact of socket connector .9 Table 1 Ratings and characteristics .10 Table 2 Acceptance tests.11 Table 3 Periodic tests 12 3 EN 61169-2:2007Annex ZA (normative) Normative references to international publications with their corresponding Eur

20、opean publications 20RADIO-FREQUENCY CONNECTORS Part 2: Sectional specification Radio frequency coaxial connectors type 9,52 1 Scope This part of IEC 61169, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for RF coaxial connec

21、tors of type 9,52. It describes the interface dimensions for general purpose grade 2 connectors, dimensional details for standard test connectors, grade 0, together with gauging information and the mandatory tests selected from IEC 61169-1, applicable to all DS relating to type 9,52 connectors. This

22、 specification indicates the recommended performance characteristics to be considered when writing a DS and covers test schedules and inspection requirements. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only

23、the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 61169-1:1992, Radio-frequency connectors Part 1: Generic specification General requirements and measuring methods 3 Interface dimensions 3.1 Interface 3.1.1 Genera

24、l All dimensions are in millimetres. All undimensioned pictorial configurations are for reference purposes only. 3.1.2 Dimensions Figures 1, 2 and 3 provide dimensions for sliding connectors, screw coupling connectors and standard test connectors respectively. 4 EN 61169-2:2007 5 9,1 min.7,11+0,4300

25、,8 0,42 max.1 +0,30,12,35+0,030,088,5 min.9,525 0,05 Cone or radiusIEC 105/07 Figure 1a Sliding male connector 7,54 min.0,5+1,50IEC 106/07Figure 1b Sliding female connector Figure 1 Sliding connector EN 61169-2:2007 6 7,11+0,4304 0,54 min.M14 1Optional sealing gasket IEC 107/07Figure 2a Screw coupli

26、ng male connector 5 min.M14 1IEC 108/07Figure 2b Screw coupling female connector Figure 2 Screw coupling connector EN 61169-2:2007 7 9,1 min.7,11 +0,430 0,8 0,42 max.1 +0,30,12,35 0,018,5 0,029,525 0,05 4 min. M141IEC 109/07 Figure 3a Standard test male connector 4 slots width 0,3 mmlenght 4,5 mmM14

27、 10,5+0,205 min.7,2 min.7,54 min.3,2 0,02 IEC 110/07 Figure 3b Standard test female connector Figure 3 Standard test connectors EN 61169-2:2007 8 3.2 Mechanical gauges 3.2.1 General All dimensions are in millimetres. All undimensioned pictorial configurations are for reference purposes only. 3.2.2 S

28、ocket connectors Gauges for the resilient outer contact Figure 4 illustrates gauge pins for outer contacts of socket connectors. b 7 0,5aIEC 111/07 Surface finish: Ra 1 G after conditioning 1 M Proof voltage at sea level bc.9.2.6 750 V 86 kPa - 106 kPa Screening effectiveness .9.2.8 as 90 dB Zt Disc

29、harge test (Corona) .9.2.9 na Mechanical Gauge retention force (resilient contacts) 9.3.4 See 3.2 of IEC 61169-1 Contact captivation axial force torque 9.3.5 30 N na Captivated contacts only Engagement and separation Coupling torque friction coupling proof 9.3.6 0,066 Nm max. 0,46 Nm to 0,69 Nm 1,7

30、Nm Screw coupling connectors To overcome friction of a coupling nut Mechanical tests on cable cable pulling cable torsion 9.3.8 9.3.10 120 N 0,1 Nm Tensile strength of coupling mechanism 9.3.11 300 N Bending moment 9.3.12 2 Nm Relative to reference plane Environmental Vibration 9.3.3 98 m/s 10 Hz to

31、 500 Hz 10 g acceleration Climatic sequence 9.4.2 40/70/21 Sealing 9.4.5 1 cm3/h max 100 kPa - 110 kPa pressure Salt mist 9.4.6 48 h Endurance Mechanical 0,19.57.10 1 000 cycles High temperature 9.60 1 000 h aThese values apply to basic connectors. They depend on the cable used. Relevant values are

32、given in the DS. bVoltage values are r.m.s. values at 50 Hz 60 Hz, unless otherwise specified. cCables used with these connectors may have values of lower performance than those given in this table. EN 61169-2:2007 11 4.3 Test schedule and inspection requirements 4.3.1 Acceptance tests Table 2 indic

33、ates the various acceptance tests, methods and assessment criteria involved. Table 2 Acceptance tests Assessment level M (higher) Assessment level H (lower) Test method IEC 61169-1 subclause Test Required IL AQL % PeriodTest Required IL AQL % PeriodGroup A1 Visual examination 9.1.2 a II 1,0 A S3 1,5

34、 Group B1 Outline dimensions 9.1.3.1 a S4 0,4 A S3 4,0 Mechanical compatibility 9.1.3.3 a II 1,0 A S3 1,5 Engagement and separation 9.3.6 a S4 0,40 Lot A S3 1,5 Lot Gauge retention (resilient contact) 9.3.4 ia II 1,0 Ia S3 1,5 Sealing, non-hermetic 9.4.5.1 ia II 0,65 by ia S3 1,0 by Sealing, hermeti

35、c 9.4.5.2 ia II 0,015 ia S3 0,025 Voltage proof 9.2.6 a S4 0,40 lot a II 4,0 lot Solderability piece parts 9.3.2.1.1 ia S4 0,40 ia S3 4,0 Insulation resistance 9.2.5 a S4 0,40 a S3 4,0 NOTE Details of symbols, abbreviations and procedures: a = suggested as applicable ia = test suggested (if technica

36、lly applicable) IL = Inspection Level AQL = Acceptable Quality Level (d) = destructive tests specimens shall not be returned to stock 4.3.2 Periodic tests Table 3 indicates the various periodic tests, methods and assessment criteria involved. There are no group C tests for levels H and M. EN 61169-2

37、:2007 12 Table 3 Periodic tests Assessment level M (higher) Assessment level H (lower) Test method IEC 61169-1 subclause Test required Number of speci-mens Permitted failures per group# Period Test required Number of speci-mens Permitted failures per group# Period Group D1 (d) 6 1 3 years 3 1 3 year

38、s Solderability connector assemblies 9.3.2.1.1 ia ia Resistance to soldering heat 9.3.2.1.2 ia ia Mechanical tests on cable fixing cable rotation (nutation) 9.3.7.2 ia ia cable pulling 9.3.8 ia ia cable bending 9.3.9 ia ia cable torsion 9.3.10 ia ia Group D2 (d) 6 1 3 years 3 1 3 years Contact resis

39、tance, outer conductor and screen continuity centre conductor continuity 9.2.3 a a Vibration 9.3.3 a Damp heat, steady state 9.4.3 a a Group D3 (d) 1* 1 3 years 1* 1 3 years Dimensions piece-parts and materials 9.1.3.2 a a Group D4 (d) 6 1 3 years 3 1 3 years Mechanical endurance 9.5 a a High temper

40、ature endurance 9.6 a a Sulphur dioxide 9.4.8 na na Group D5 (d) 6 1 3 years 3 1 3 years Reflection factor 9.2.1 a a Screening effectiveness 9.2.8 a a Water immersion 9.2.7 ia ia Group D6 (d) 6 1 3 years 3 1 3 years Contact captivation 9.3.5 a a Rapid change of temperature 9.4.4 na na Climatic seque

41、nce 9.4.2 a a EN 61169-2:2007 13 Table 3 (continued) Assessment level M (higher) Assessment level H (lower) Test method IEC 61169-1 subclause Test required Number of speci-mens Permitted failures per group# Period Test required Number of speci-mens Permitted failures per group# Period Group D7 (d) 1

42、 3 years 1 3 years Resistance to solvents and contaminating fluids 9.7 ia ia Details of symbols, abbreviations and procedures: a = suggested as applicable ia = test suggested (if technically applicable) na = not applicable IL = Inspection Level AQL = Acceptable Quality Level * = one set of piece-par

43、ts each style and variant, unless using common piece parts # = for Qualification Approval (QA) a total of two failures only permitted for level H and 1 failure only for level M from groups D1 to D7 = Group D7 number of pairs for each solvent (d) = destructive tests specimens shall not be returned to

44、 stock 4.4 Procedures 4.4.1 Quality conformance inspection This shall consist of test groups A1 and B1 on a lot-by-lot basis. 4.4.2 Qualification approval and its maintenance This shall consist of three consecutive lots passing test groups A1 and B1 followed by selection of specimens from the lots a

45、s appropriate. These specimens shall successfully pass the specified periodic D tests. 5 Instructions for preparation of detail specifications 5.1 General Detail specifications (DS) writers shall use the appropriate BDS pro-forma. The following pages comprise the pro-forma BDS dedicated for use with

46、 75 type 9,52 connectors. As such, it will already have entered on it information relating to a) the basic specification number applicable to all the detail specifications covering connector styles of the type covered by the sectional specification; b) the connector series designation. The specifica

47、tion writer should enter the details relating to the connector style/variant(s) to be covered as indicated. The numbers in brackets on the BDS pro-forma correspond to the following indications which shall be given. 5.2 Identification of the detail specification (1) The name of the National Standards

48、 Organization (NSO) under whose authority the DS is published and, if applicable, the organization from whom the DS is available. (2) The relevant mark of conformity and the number allotted to the DS by the relevant national or international organization authorizing the DS EN 61169-2:2007 14 (3) The number and issue number of the IEC/IECQ generic or sectional specification as relevant; also national reference if different. (4) If different from the IEC/IECQ number, any national number of the DS, date of issue and any further information required by the national system, together with any ame

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1