1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationFibre optic interconnectingdevices and passive components Basic test and measurement proceduresPart 2-33: Tests Assembly and disassembly of fibre optic mechanical splices, fibre
2、management systems and closuresBS EN 61300-2-33:2012National forewordThis British Standard is the UK implementation of EN 61300-2-33:2012. It isidentical to IEC 61300-2-33:2012. It supersedes BS EN 61300-2-33:2007which is withdrawn.The UK participation in its preparation was entrusted by Technical C
3、ommitteeGEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre optic interconnectingdevices and passive components.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions of acontract. U
4、sers are responsible for its correct application. The British Standards Institution 2012Published by BSI Standards Limited 2012ISBN 978 0 580 74149 4ICS 33.180.20 Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority o
5、f the StandardsPolicy and Strategy Committee on 31 October 2012.Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 61300-2-33:2012EUROPEAN STANDARD EN 61300-2-33 NORME EUROPENNE EUROPISCHE NORM October 2012 CENELEC European Committee for Electrotechnical Standardizat
6、ion Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2012 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61300-2-33:2012 E ICS
7、 33.180.20 Supersedes EN 61300-2-33:2007English version Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-33: Tests - Assembly and disassembly of fibre optic mechanical splices, fibre management systems and closures (IEC 61300-2-33:2012) Disp
8、ositifs dinterconnexion et composantspassifs fibres optiques - Mthodes fondamentales dessais et de mesures - Partie 2-33: Essais - Montage et dmontage des pissures mcaniques de fibres optiques, des systmes de gestion des fibres et des botiers (CEI 61300-2-33:2012) Lichtwellenleiter -Verbindungseleme
9、nte und passive Bauteile - Grundlegende Prf- und Messverfahren - Teil 2-33: Prfungen - Montage und Demontage von mechanischen LWL-Spleien, Fasermanagementsystemen und Muffen (IEC 61300-2-33:2012) This European Standard was approved by CENELEC on 2012-08-28. CENELEC members are bound to comply with t
10、he CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Manageme
11、nt Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the sam
12、e status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lit
13、huania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 61300-2-33:2012EN 61300-2-33:2012 - 2 - Foreword The text of document 86B/3330/CDV, future edition 3 of IEC 61300-2-33, prepared by SC 8
14、6B, “Fibre optic interconnecting devices and passive components“, of IEC TC 86, “Fibre optics“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 61300-2-33:2012. The following dates are fixed: latest date by which the document has to be implemented at national level by pub
15、lication of an identical national standard or by endorsement (dop) 2013-05-28 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2013-08-28 This document supersedes EN 61300-2-33:2007. EN 61300-2-33:2012 includes the following significant technical c
16、hanges with respect to EN 61300-2-33:2007: the inclusion of fibre management system and ancillary passive and active components as well as cable management system for the incoming and outgoing optical cables. Attention is drawn to the possibility that some of the elements of this document may be the
17、 subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 61300-2-33:2012 was approved by CENELEC as a European Standard without any modification. In the official version, f
18、or Bibliography, the following note has to be added for the standard indicated: IEC 61300-1 NOTE Harmonized as EN 61300-1. BS EN 61300-2-33:2012- 3 - EN 61300-2-33:2012 Annex ZA (normative) Normative references to international publications with their corresponding European publications The followin
19、g documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an intern
20、ational publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 61300-2-22 - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperat
21、ure EN 61300-2-22 - IEC 61300-3-28 - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-28: Examinations and measurements - Transient loss EN 61300-3-28 - IEC 61753-1 - Fibre optic interconnecting devices and passive components performance sta
22、ndard - Part 1: General and guidance for performance standards EN 61753-1 - BS EN 61300-2-33:2012 2 61300-2-33 IEC:2012(E) CONTENTS 1 Scope . 5 2 Normative references 5 3 Terms and definitions . 5 4 General description . 6 5 Procedure . 6 5.1 Preparation of the specimen 6 5.2 Test procedures 6 5.2.1
23、 Procedure A: Re-installation of an optical mechanical splice after disassembly . 6 5.2.2 Procedure B: Optical stability during product reconfiguration 6 5.2.3 Procedure C: Sealing performance after frequent opening and closing of the enclosures . 7 5.2.4 Ageing procedure . 7 5.3 Severity . 9 6 Deta
24、ils to be specified . 9 Annex A (informative) Installation and intervention procedure for closure optical stability . 10 Bibliography 11 Table 1 Ageing procedure between two cycles of assembly and disassembly of fibre optic mechanical splices and closures . 8 Table 2 Number of assembly/disassembly c
25、ycles for different operating environments . 9 BS EN 61300-2-33:201261300-2-33 IEC:2012(E) 5 FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS BASIC TEST AND MEASUREMENT PROCEDURES Part 2-33: Tests Assembly and disassembly of fibre optic mechanical splices, fibre management systems and clos
26、ures 1 Scope This part of the IEC 61300 series, evaluates the assembly and reassembly of a fibre optic mechanical splice, a fibre management system or a closure for a specified number of times. The test procedures simulate the following conditions which may be encountered during the components servi
27、ce lifetime: the ability of an optical mechanical splice to be re-installed after disassembly; the ability to re-enter fibre management systems and closures, by accessing fibres and optical components and making reconfigurations without disturbing transmission in adjacent fibre circuits; verificatio
28、n of the sealing performance after frequent opening and closing of enclosures. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated
29、 references, the latest edition of the referenced document (including any amendments) applies. IEC 61300-2-22, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-22: Tests Change of temperature IEC 61300-3-28, Fibre optic interconnecting devices a
30、nd passive components Basic test and measurement procedures Part 3-28: Examinations and measurements Transient loss IEC 61753-1, Fibre optic interconnecting devices and passive components Part 1: General and guidance for performance standards 3 Terms and definitions For the purpose of this document,
31、 the following terms and definitions apply. 3.1 closure all external housings except outdoor cabinets 3.2 fibre management system system to control fibre routing from the incoming to the outgoing fibres BS EN 61300-2-33:2012 6 61300-2-33 IEC:2012(E) 3.3 re-entry access to the fibre management system
32、 after initial installation 3.4 mechanical splice a fibre splice accomplished by fixtures or materials, rather than by thermal fusion Note 1 to entry: Index matching material may be applied between the two fibre ends. 4 General description Three test procedures are described. Procedure A tests the a
33、bility of optical mechanical splices to be re-installed after disassembly. Procedure B tests the ability to re-enter fibre management systems and closures, by accessing fibres and optical components and making reconfigurations without disturbing transmission in adjacent fibre circuits. Procedure C v
34、erifies the sealing performance after frequent opening and closing of enclosures. The mechanical splice, fibre management system or (en)closure shall be assembled and reassembled a specified number of times following the manufacturers instructions, including any specified cleaning or recovery proced
35、ure. The test shall be done according to requirements referenced in IEC 61753-1. Assembly and disassembly of the mechanical splice, fibre management system or closure shall be carried out at room temperature, unless otherwise specified. 5 Procedure 5.1 Preparation of the specimen Assembly tools and
36、consumable materials, as specified by the manufacturer, shall be used. 5.2 Test procedures 5.2.1 Procedure A: Re-installation of an optical mechanical splice after disassembly General description of the steps for Procedure A is defined as follows. 1) Assemble the mechanical splice according to the m
37、anufacturers installation instructions using the specified fibre or cable. 2) Perform any required examination and measurements as specified in the relevant performance standard. 3) Perform the temperature ageing cycle as specified in the relevant performance standard. When not specified, the ageing
38、 cycle as defined in Table 1 shall be used. After the ageing cycle allow the specimen to recover at ambient temperature for at least 2 hours. 4) Disassemble the mechanical splice to the specified extent or to the point that all internal fibres and devices can be accessed or removed. 5) Perform any s
39、pecified cleaning and fibre preparation operations. 6) Re-install the mechanical splice according to the manufacturers instructions. 7) Perform any required examinations and measurements as specified in the relevant specification. 8) Repeat steps 3 through 7 for the number of cycles specified. 5.2.2
40、 Procedure B: Optical stability during product reconfiguration General description of the steps for Procedure B is defined as follows. BS EN 61300-2-33:201261300-2-33 IEC:2012(E) 7 1) Assemble the (en)closure or fibre management system according to the manufacturers instructions using the specified
41、fibre or cable. An optical circuit is built as specified in the performance standard. 2) Perform any required examination and measurements as specified in the relevant performance standard. The change in attenuation in the optical circuit shall be measured with the transient loss procedure, IEC 6130
42、0-3-28, when performing steps 3, 4 and 5. 3) The handling operations shall be performed as specified in the performance standard (see Annex A for a typical example). The (en)closure shall be disassembled to the specified extent or to the point that the internal fibres and devices can be accessed or
43、removed. 4) Perform the specified reconfiguration operations. 5) Close and secure the fibre management system and reassemble the (en)closure according to the manufacturers instructions. 5.2.3 Procedure C: Sealing performance after frequent opening and closing of the enclosures General description of
44、 the steps for Procedure C is defined as follows. 1) Assemble the (en)closure according to the manufacturers installation instructions using the specified fibre or cable. 2) Perform any required examination and check sealing performance as specified in the relevant performance standard. 3) When spec
45、ified in the performance standard, perform the specified temperature ageing cycle. After the ageing cycle, allow the (en)closure to recover at ambient temperature for at least 4 hours. 4) Disassemble the (en)closure to the specified extent or to the point that all internal fibres and devices can be
46、accessed or removed. 5) Re-install the (en)closure according to the manufacturers installation instructions. 6) Perform any required examinations and check sealing performance as specified in the relevant specification. 7) Repeat steps 3 through 6 for the number of cycles specified. 5.2.4 Ageing pro
47、cedure If specified in the relevant performance standard, the product shall be submitted to an aeging process between assembly and disassembly operations. The major reason for the ageing process is to speed up the creep of the polymeric materials in the alignment area or sealing area after a re-entr
48、y is completed. The purpose of the ageing procedure includes: identification of the design failures; identification of manufacturing defects; impact of product ageing on assembly and disassembly. Table 1 shows ageing conditions. The ageing conditions are based on the operating environmental conditio
49、ns given in IEC 61753-1. BS EN 61300-2-33:2012 8 61300-2-33 IEC:2012(E) Table 1 Ageing procedure between two cycles of assembly and disassembly of fibre optic mechanical splices and closures Operating environment Ageing conditions IEC 61300-2-22 Ageing conditions for Procedure A: Mechanical splices Controlled C -10 C 2 C to +60 C 2 C 2 h duration at extremes 1 C/min rate of change 1 cycle Uncontrolled U -40 C 2 C to +70 C 2 C 2 h duration at extremes