BS EN 61300-3-3-2009 Fibre optic interconnecting ndevices and passive components n— Basic test and measurement nprocedures — nPart 3-3 Examinations and measurements — Active nmonit.pdf

上传人:explodesoak291 文档编号:577343 上传时间:2018-12-13 格式:PDF 页数:24 大小:940.80KB
下载 相关 举报
BS EN 61300-3-3-2009 Fibre optic interconnecting ndevices and passive components n— Basic test and measurement nprocedures — nPart 3-3 Examinations and measurements — Active nmonit.pdf_第1页
第1页 / 共24页
BS EN 61300-3-3-2009 Fibre optic interconnecting ndevices and passive components n— Basic test and measurement nprocedures — nPart 3-3 Examinations and measurements — Active nmonit.pdf_第2页
第2页 / 共24页
BS EN 61300-3-3-2009 Fibre optic interconnecting ndevices and passive components n— Basic test and measurement nprocedures — nPart 3-3 Examinations and measurements — Active nmonit.pdf_第3页
第3页 / 共24页
BS EN 61300-3-3-2009 Fibre optic interconnecting ndevices and passive components n— Basic test and measurement nprocedures — nPart 3-3 Examinations and measurements — Active nmonit.pdf_第4页
第4页 / 共24页
BS EN 61300-3-3-2009 Fibre optic interconnecting ndevices and passive components n— Basic test and measurement nprocedures — nPart 3-3 Examinations and measurements — Active nmonit.pdf_第5页
第5页 / 共24页
亲,该文档总共24页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI British StandardsWB9423_BSI_StandardColCov_noK_AW:BSI FRONT COVERS 5/9/08 12:55 Page 1Fibre optic interconnectingdevices and passive components Basic test and measurementprocedures Part 3-3: Examinat

2、ions and measurements Activemonitoring of changes in attenuation and return lossBS EN 61300-3-3:2009National forewordThis British Standard is the UK implementation of EN 61300-3-3:2009. It isidentical to IEC 61300-3-3:2009. It supersedes BS EN 61300-3-3:2003 whichis withdrawn.The UK participation in

3、 its preparation was entrusted by Technical CommitteeGEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre optic interconnectingdevices and passive components.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include

4、 all the necessary provisions of acontract. Users are responsible for its correct application. BSI 2009ISBN 978 0 580 60772 1ICS 33.180.20Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the StandardsPolicy and

5、 Strategy Committee on 31 May 2009Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 61300-3-3:2009EUROPEAN STANDARD EN 61300-3-3 NORME EUROPENNE EUROPISCHE NORM May 2009 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation E

6、lectrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: avenue Marnix 17, B - 1000 Brussels 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61300-3-3:2009 E ICS 33.180.20 Supersedes EN 61300-3-3:

7、2003English version Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-3: Examinations and measurements - Active monitoring of changes in attenuation and return loss (IEC 61300-3-3:2009) Dispositifs dinterconnexion et composants passifs fibres

8、 optiques - Mthodes fondamentales dessais et de mesures - Partie 3-3: Examens et mesures - Contrle actif des variations de laffaiblissement et du facteur dadaptation (CEI 61300-3-3:2009) Lichtwellenleiter -Verbindungselemente und passive Bauteile - Grundlegende Prf- und Messverfahren - Teil 3-3: Unt

9、ersuchungen und Messungen - Aufzeichnung der nderung von Dmpfung und Rckflussdmpfung (IEC 61300-3-3:2009) This European Standard was approved by CENELEC on 2009-04-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this Europea

10、n Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (Englis

11、h, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Be

12、lgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 61

13、300-3-3:2009EN 61300-3-3:2009 2 Foreword The text of document 86B/2808/FDIS, future edition 3 of IEC 61300-3-3, prepared by SC 86B, Fibre optic interconnecting devices and passive components, of IEC TC 86, Fibre optics, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN

14、 61300-3-3 on 2009-04-01. This European Standard supersedes EN 61300-3-3:2003. The change with respect to EN 61300-3-3:2003 is the structure of the document. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national st

15、andard or by endorsement (dop) 2010-01-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2010-04-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 61300-3-3:2009 was approved by CENELEC as a European

16、 Standard without any modification. _ BS EN 61300-3-3:2009 3 EN 61300-3-3:2009 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following referenced documents are indispensable for the application of this document. For dated r

17、eferences, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Titl

18、e EN/HD Year IEC 61300-1 - 1)Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 1: General and guidance EN 61300-1 2003 2)IEC 61300-3-1 - 1)Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part

19、 3-1: Examinations and measurements - Visual examination EN 61300-3-1 2005 2)IEC 61300-3-6 - 1)Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return loss EN 61300-3-6 2009 2)IEC 61300-3-35 200X 3)Fibre op

20、tic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-35: Examinations and measurements - Fibre optic cylindrical connector endface visual and automated inspection - - 1)Undated reference. 2)Valid edition at date of issue. 3)To be published. BS EN 61300-

21、3-3:2009 2 61300-3-3 IEC:2009(E) CONTENTS 1 Scope.6 2 Normative references .6 3 General description 6 3.1 Test method 6 3.2 Precautions .7 4 Apparatus.7 4.1 Methods 1, 2 and 37 4.1.1 General .7 4.1.2 Source (S).7 4.1.3 Launch condition (E)8 4.1.4 Monitoring equipment 8 4.1.5 Detector D.9 4.1.6 Stres

22、s fixture .9 4.1.7 Branching device BD .9 4.1.8 Temporary joints9 4.1.9 Data acquisition.9 4.1.10 Monitor sample9 4.1.11 Reference fibre10 4.2 Methods 4 and 511 4.2.1 General .11 4.2.2 OTDR11 4.2.3 Buffer fibre 11 4.2.4 Optical switches 11 5 Procedure 13 5.1 Monitoring attenuation and return loss of

23、 a single sample method 1 .13 5.1.1 General .13 5.1.2 Attenuation monitoring method 1 13 5.1.3 Return loss monitoring method 1 14 5.2 Monitoring attenuation and return loss of multiple samples using a 1 N branching device method 2.14 5.2.1 General .14 5.2.2 Attenuation monitoring method 2 14 5.2.3 R

24、eturn loss monitoring method 2 14 5.3 Monitoring attenuation and return loss of multiple samples using two 1 N optical switches method 3 14 5.3.1 General .14 5.3.2 Attenuation method 314 5.3.3 Return loss method 315 5.4 Bidirectional OTDR monitoring of attenuation and return loss of multiple samples

25、 method 4 16 5.4.1 General .16 5.4.2 Attenuation method 416 5.4.3 Return loss method 418 5.5 Unidirectional OTDR monitoring of attenuation and return loss of multiple samples method 5 19 6 Details to be specified 19 BS EN 61300-3-3:200961300-3-3 IEC:2009(E) 3 6.1 Method 1 .19 6.2 Methods 2 and 320 6

26、.3 Methods 4 and 520 Figure 1 Method 1 Monitoring attenuation and return loss of a single sample undergoing stress testing10 Figure 2 Method 2 Monitoring attenuation and return loss of multiple samples using a 1 N branching device .10 Figure 3 Method 3 Monitoring attenuation and return loss of multi

27、ple samples using two 1 N optical switches .11 Figure 4 Method 4 Bidirectional OTDR monitoring of attenuation and return loss of multiple samples.12 Figure 5 Method 5 Unidirectional OTDR monitoring of attenuation and return loss of multiple samples.13 Figure 6 Cut-back measurement location (transmis

28、sion) 15 Figure 7 Typical OTDR trace caused by the reflection from a DUT.17 Figure 8 Cut-back measurement location (OTDR) 18 Table 1 Example values for Rayleigh backscatter coefficient19 BS EN 61300-3-3:2009 6 61300-3-3 IEC:2009(E) FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS BASIC TES

29、T AND MEASUREMENT PROCEDURES Part 3-3: Examinations and measurements Active monitoring of changes in attenuation and return loss 1 Scope This part of IEC 61300 describes the procedure to monitor changes in attenuation and/or return loss of a component or an interconnecting device, when subjected to

30、an environmental or mechanical test. Such a procedure is commonly referred to as active monitoring. In many instances, it is more efficient to monitor attenuation and return loss at the same time. The procedure may be applied to measurements on single samples or to simultaneous measurements on multi

31、ple samples, both at single wavelengths and multiple wavelengths, by using branching devices and/or switches as appropriate. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For und

32、ated references, the latest edition of the referenced document (including any amendments) applies. IEC 61300-1, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 1: General and guidance IEC 61300-3-1, Fibre optic interconnecting devices and passive

33、 components Basic test and measurement procedures Part 3-1: Examinations and measurements Visual examination IEC 61300-3-6, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 3-6: Examinations and measurements Return loss IEC 61300-3-35, Fibre optic

34、 interconnecting devices and passive components Basic test and measurement procedures Part 3-35: Examinations and measurements Fibre optic cylindrical connector endface visual and automated inspection13 General description 3.1 Test method The procedure describes a number of active monitoring measure

35、ment methods. Method 1 describes the situation where a single sample is subject to mechanical or environmental stress testing. Methods 2 and 3 describe methods for monitoring changes in the optical performance of multiple samples. Methods 4 and 5 measure changes in the optical performance of samples

36、 using an OTDR. Methods 4 and 5 may be used only when the OTDR averaging time is much less than the variation time of the test conditions. Where there is any form of uncertainty over the measurement method used, method 1 shall be considered to be the reference method. 1To be published. BS EN 61300-3

37、-3:200961300-3-3 IEC:2009(E) 7 All methods are capable of being configured to monitor changes in attenuation and return loss at the same time. The required optical test parameters shall be defined in the relevant specification. Where a group of samples is being monitored over a period of time, say s

38、everal days or weeks, it is usual to employ some form of automated data acquisition. Also, since the changes in optical performance can be very small, it is important to ensure high measurement stability over time. 3.2 Precautions The following requirements shall be met. a) Precautions shall be take

39、n to ensure that cladding modes do not affect the measurement. b) Precautions shall be taken to prevent movement in the position of the fibre cables between the sample(s) and the test apparatus, to avoid changes in optical performance caused by bending losses. c) The stability performance of the tes

40、t equipment shall be 0,05 dB or 10 % of the attenuation to be measured, whichever is the lower value. The stability shall be maintained over the measurement time. The required measurement resolution shall be 0,01 dB for both multimode and single-mode. d) To achieve consistent results, clean and insp

41、ect all samples prior to measurement in accordance with the manufacturers instructions. Visual examination shall be undertaken in accordance with IEC 61300-3-1 and IEC 61300-3-35. e) The power in the fibre shall be at a level that does not generate non-linear scattering effects (typically 10 dB, the

42、 following approximation for return loss may be used. RLi,t Pi,t Gi(5) The constant Giis evaluated using measurements made with the fibre from channel “i” of switch 1 terminated with a reference return loss. The reference return loss is a length of fibre one end of which is terminated with a known r

43、eturn loss. Gi= Pi,r S + 10 log (1 10 P/10) (6) where S is the reference return loss, in decibels (dB); Pi,sis the normalized power in channel “i” terminated with reference return loss S, in decibels (dB); P = Pi,s Pi,o(7) where Pi,ois the normalized reflected power with a high attenuation in the fi

44、bre using, for example, a mandrel wrap between the reference return loss S and SW1. 5.4 Bidirectional OTDR monitoring of attenuation and return loss of multiple samples method 4 5.4.1 General Due to the complexity of the test set-up, it is typical for the various parts of the apparatus, including th

45、e OTDR, to be computer-controlled. This control ensures that the 1 N switches are stepped synchronously and that the sources are switched at the appropriate time to make the necessary number of measurements. The control also ensures that the sequence is repeated periodically as defined in the releva

46、nt specification for the duration of the stress test. 5.4.2 Attenuation method 4 A measurement of attenuation of the DUT in channel “i” at time “t” is carried out as follows: iti,ti,ti,2JXrXfL += (8) where BS EN 61300-3-3:200961300-3-3 IEC:2009(E) 17 Xfi,tis the change in power in the OTDR display f

47、or the component under test with switch 1 set on channel “i”; Xri,tis the same as Xf i,texcept that switch 2 is set on channel “i”, and switch 1 is set on channel “rev”; Jiis a constant for channel “i”. The values of Xf and Xr are values of loss as seen in both the forward and reverse directions of

48、transmission plus loss in the temporary joints (see Figure 7). HDistance OTDR Signal dBXf, XrIEC 028/03 Figure 7 Typical OTDR trace caused by the reflection from a DUT NOTE Since this is a monitoring experiment, only the change in attenuation is considered significant. Thus the change in Li,tfrom th

49、e initial measurement is the important factor, rather than the absolute value of Li,tThe constant Jiis determined with a cut-back measurement made at the completion of the test sequence. The sequence of measurements in the determination of Jiis, first, to make the measurements Xfi,cand Xri,c, replace the OTDR with a dual-wavelength source, make cut-back measurement A

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
  • ASTM C1245 C1245M-2012 Standard Test Method for Determining Relative Bond Strength Between Hardened Roller Compacted Concrete Lifts (Point Load Test)《测定硬化碾压混凝土和其他硬化粘结混合物间粘合强度的标准试验方.pdf ASTM C1245 C1245M-2012 Standard Test Method for Determining Relative Bond Strength Between Hardened Roller Compacted Concrete Lifts (Point Load Test)《测定硬化碾压混凝土和其他硬化粘结混合物间粘合强度的标准试验方.pdf
  • ASTM C1246-2000(2006) Standard Test Method for Effects of Heat Aging on Weight Loss Cracking and Chalking of Elastomeric Sealants After Cure《弹性体密封剂凝固后热老化对重量损失、裂开和粉化影响的标准试验方法》.pdf ASTM C1246-2000(2006) Standard Test Method for Effects of Heat Aging on Weight Loss Cracking and Chalking of Elastomeric Sealants After Cure《弹性体密封剂凝固后热老化对重量损失、裂开和粉化影响的标准试验方法》.pdf
  • ASTM C1246-2000(2012) Standard Test Method for Effects of Heat Aging on Weight Loss Cracking and Chalking of Elastomeric Sealants After Cure 《弹性体密封剂凝固后热老化对重量损失、裂开和粉化影响的标准试验方法》.pdf ASTM C1246-2000(2012) Standard Test Method for Effects of Heat Aging on Weight Loss Cracking and Chalking of Elastomeric Sealants After Cure 《弹性体密封剂凝固后热老化对重量损失、裂开和粉化影响的标准试验方法》.pdf
  • ASTM C1246-2017 Standard Test Method for Effects of Heat Aging on Weight Loss Cracking and Chalking of Elastomeric Sealants After Cure《固后弹性体密封剂热老化影响重量损失 开裂和粉化的标准试验方法》.pdf ASTM C1246-2017 Standard Test Method for Effects of Heat Aging on Weight Loss Cracking and Chalking of Elastomeric Sealants After Cure《固后弹性体密封剂热老化影响重量损失 开裂和粉化的标准试验方法》.pdf
  • ASTM C1247-1998(2004) Standard Test Method for Durability of Sealants Exposed to Continuous Immersion in Liquids《连续浸液的密封剂寿命标准试验方法》.pdf ASTM C1247-1998(2004) Standard Test Method for Durability of Sealants Exposed to Continuous Immersion in Liquids《连续浸液的密封剂寿命标准试验方法》.pdf
  • ASTM C1247-2009 Standard Test Method for Durability of Sealants Exposed to Continuous Immersion in Liquids《连续浸液的密封剂寿命的标准试验方法》.pdf ASTM C1247-2009 Standard Test Method for Durability of Sealants Exposed to Continuous Immersion in Liquids《连续浸液的密封剂寿命的标准试验方法》.pdf
  • ASTM C1247-2014 Standard Test Method for Durability of Sealants Exposed to Continuous Immersion in Liquids《连续浸液的密封剂寿命标准试验方法》.pdf ASTM C1247-2014 Standard Test Method for Durability of Sealants Exposed to Continuous Immersion in Liquids《连续浸液的密封剂寿命标准试验方法》.pdf
  • ASTM C1248-2006 Standard Test Method for Staining of Porous Substrate by Joint Sealants《用接缝密封胶着色多孔衬底的标准试验方法》.pdf ASTM C1248-2006 Standard Test Method for Staining of Porous Substrate by Joint Sealants《用接缝密封胶着色多孔衬底的标准试验方法》.pdf
  • ASTM C1248-2008 Standard Test Method for Staining of Porous Substrate by Joint Sealants《用接缝密封胶着色多孔衬底的标准试验方法》.pdf ASTM C1248-2008 Standard Test Method for Staining of Porous Substrate by Joint Sealants《用接缝密封胶着色多孔衬底的标准试验方法》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1