BS EN 62054-11-2004 Electricity metering equipment (a c ) - Tariff and load control - Particular requirements for electronic ripple control receivers《电量测量设备(交流) 税费和负荷控制 电子脉动控制接收器的特.pdf

上传人:roleaisle130 文档编号:578112 上传时间:2018-12-13 格式:PDF 页数:26 大小:650.29KB
下载 相关 举报
BS EN 62054-11-2004 Electricity metering equipment (a c ) - Tariff and load control - Particular requirements for electronic ripple control receivers《电量测量设备(交流) 税费和负荷控制 电子脉动控制接收器的特.pdf_第1页
第1页 / 共26页
BS EN 62054-11-2004 Electricity metering equipment (a c ) - Tariff and load control - Particular requirements for electronic ripple control receivers《电量测量设备(交流) 税费和负荷控制 电子脉动控制接收器的特.pdf_第2页
第2页 / 共26页
BS EN 62054-11-2004 Electricity metering equipment (a c ) - Tariff and load control - Particular requirements for electronic ripple control receivers《电量测量设备(交流) 税费和负荷控制 电子脉动控制接收器的特.pdf_第3页
第3页 / 共26页
BS EN 62054-11-2004 Electricity metering equipment (a c ) - Tariff and load control - Particular requirements for electronic ripple control receivers《电量测量设备(交流) 税费和负荷控制 电子脉动控制接收器的特.pdf_第4页
第4页 / 共26页
BS EN 62054-11-2004 Electricity metering equipment (a c ) - Tariff and load control - Particular requirements for electronic ripple control receivers《电量测量设备(交流) 税费和负荷控制 电子脉动控制接收器的特.pdf_第5页
第5页 / 共26页
亲,该文档总共26页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、BRITISH STANDARDBS EN 62054-11:2004 Incorporating Corrigendum No. 1Electricity metering (a.c.) Tariff and load control Part 11: Particular requirements for electronic ripple control receiversThe European Standard EN 62054-11:2004 has the status of a British StandardICS 91.140.50 g49g50g3g38g50g51g60

2、g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58Licensed Copy: Wang Bin, na, Mon Mar 20 06:57:28 GMT 2006, Uncontrolled Copy, (c) BSIBS EN 62054-11:2004This British Sta

3、ndard was published under the authority of the Standards Policy and Strategy Committee on 25 November 2004 BSI 31 October 2005ISBN 0 580 44883 5 National forewordThis British Standard is the official English language version of EN 62054-11:2004. It is identical with IEC 62054-11:2004. This standard,

4、 in conjunction with BS EN 62052-21, supersedes BS EN 61037:1993 which will be withdrawn on 1 July 2007.The UK participation in its preparation was entrusted to Technical Committee PEL/13, Electricity metering, which has the responsibility to: aid enquirers to understand the text; present to the res

5、ponsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK.A list of organizations represented on this committee can be obtained on r

6、equest to its secretary.Cross-referencesThe British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI

7、Electronic Catalogue or of British Standards Online.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard does not of itself confer immunity from legal obligations.Summary of pages

8、This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 23 and a back cover.The BSI copyright notice displayed in this document indicates when the document was last issued.Amendments issued since publicationAmd. No. Date CommentsCorrigendum No. 1 1561531 October 2

9、005Revision of supersession detailsLicensed Copy: Wang Bin, na, Mon Mar 20 06:57:28 GMT 2006, Uncontrolled Copy, (c) BSIEUROPEAN STANDARD EN 62054-11 NORME EUROPENNE EUROPISCHE NORM October 2004 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotec

10、hnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2004 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 62054-11:2004 E ICS 91.140.50 Partially supersedes EN 61037:19

11、92 + A1:1996 + A2:1998English version Electricity metering (a.c.) Tariff and load control Part 11: Particular requirements for electronic ripple control receivers (IEC 62054-11:2004) Equipement de comptage dlectricit (c.a.) Tarification et contrle de charge Partie 11: Prescriptions particulires pour

12、 rcepteurs lectroniques de tlcommande centralise (CEI 62054-11:2004) Wechselstrom-Elektrizittszhler Tarif- und Laststeuerung Teil 11: Besondere Anforderungen an elektronische Rundsteuerempfnger (IEC 62054-11:2004) This European Standard was approved by CENELEC on 2004-07-06. CENELEC members are boun

13、d to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Ce

14、ntral Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same

15、status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal

16、 Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. Licensed Copy: Wang Bin, na, Mon Mar 20 06:57:28 GMT 2006, Uncontrolled Copy, (c) BSIForeword The text of document 13/1306/FDIS, future edition 1 of IEC 62054-11, prepared by IEC TC 13, Equipment for electrical energy measurement a

17、nd load control, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 62054-11 on 2004-07-06. This standard, in conjunction with EN 62052-21, supersedes EN 61037:1992 + A1:1996 + A2:1998. This standard is to be used in conjunction with EN 62052-21 and the relevant parts o

18、f the EN 62059 series. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2005-05-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow

19、) 2007-07-01 This European Standard has been prepared under a mandate given to CENELEC by the European Commission and the European Free Trade Association and covers essential requirements of EC Directive(s). See Annex ZZ. Annexes ZA and ZZ have been added by CENELEC. _ Endorsement notice The text of

20、 the International Standard IEC 62054-11:2004 was approved by CENELEC as a European Standard without any modification. Corrigendum to text of IEC 62054-11:2004 In subclause 7.6.4, - replace “Field strength of the unmodulated signal: 10 V/m“ by “At field strength of 10 V/m (measured according to EN 6

21、1000-4-3)“. - replace “Field strength of the unmodulated signal: 30 V/m“ by “At field strength of 30 V/m (measured according to EN 61000-4-3)“. _ Page 2EN 6205411:2004Licensed Copy: Wang Bin, na, Mon Mar 20 06:57:28 GMT 2006, Uncontrolled Copy, (c) BSICONTENTS 1 Scope.52 Normative references .5 3 Te

22、rms and definitions .5 4 Standard electrical values 5 5 Mechanical requirements and tests 6 5.1 Operation status indicator .6 6 Climatic conditions, requirements and tests6 7 Electrical requirements and tests6 7.1 Supply voltage.6 7.2 Heating .7 7.3 Insulation 77.4 Output elements7 7.5 Functional re

23、quirements and tests Control performance .7 7.6 Electromagnetic compatibility (EMC) .9 7.7 Radio interference suppression .14 8 Test conditions and type test14 Annex A (normative) Harmonic levels for testing ripple control receivers15 Annex B (normative) Selection of frequency for tests with harmoni

24、cs.16 Annex C (normative) Combination of parameters for operation and non-operation tests.17 Annex D (informative) Acceptance tests.18 Annex E (informative) Code terms .19 Annex F (informative) Example of a test configuration for operation and non-operation tests and for measurement of disturbance-l

25、imit curves20 Annex G (informative) Values of the influence quantities for the different tests 21Fiugre .BxE 1malpse for selcetino fo teh freqeuncy Hc 16Figure B.F 2ruqenecy edviations for maesuremtne fo the disutrbnace-limit curvse .16 iFguer F.1 Test cnofiugration .20 Tbale A.1 eRcommnedde valuse

26、for 05 Hz entowrks.15 TbalC e.1 Combination fo parameters17Page 3EN 6205411:2004TNOCENTS OFREWODR.3 NITRODCUTION.4 1 Scope.52 roNmtaive referencse .5 3 Terms dna definitions .5 4 Standard electrical valeus 5 5 eMchanical requiremenst nad etsst 6 .51 Opreatoin sttasu inidcator .66 Climatci cnoditions

27、 requiremstne and tests6 7 Electricla reuqiremstne and tests. 6.71 S pply voltage 6.2 Heating .7 7.3 nIsulation 7.74 Outptu elemtnes77.5 Functioanl requiremenst and tesst Cotnrol performnace .7 7.6 Electromagnetic comaptibiilty (EMC) .9 .77 aRdio niterfrecnee spupression .14 8 Test codnitions and t

28、ype etst14 Annxe A (onrmativ)e Harmcino levesl fro testing ripple cotnrol receivers15 AnneB x (onrmavite) Seleitcon of freeuqncy for setts wiht ahrmonics.16 Annxe C (nor ative) Comibnatino fo parameters fro poeratino nad nno-poeration tests.17 ex D (i f r tiv ) Acceptnace tests.18 Annex E (informati

29、ve) Code terms .91 Annxe F (ifnromtaiv)e xEmalpe fo a tset cfnogirutaino fro oepratoin adn onn-poretaion etsst and for measuremtne fo disturbance-limit curves02 Annxe G (informative) Valuse fo the influnece uqantitise fro the differetn tests 12Figure B.1 Examples for selection of the frequency Hc 16

30、Figure B.2 Frequency deviations for measurement of the disturbance-limit curves .16 Figure F.1 Test configuration .20 Table A.1 Recommended values for 50 Hz networks.15 Table C.1 Combination of parameters17Annex ZA (normative) Normative references to international publications with theircorrespondin

31、g European publications . 23Annex ZZ (informative) Coverage of Essential Requirementsof EC Directives. . 23FOREWORD.2INTRODUCTION.4 Licensed Copy: Wang Bin, na, Mon Mar 20 06:57:28 GMT 2006, Uncontrolled Copy, (c) BSIINTRODUCTION This standard distinguishes between protective class I and protective

32、class II equipment The test levels are regarded as minimum values to guarantee the proper functioning of the equipment under normal working conditions. For special applications, other test levels might be necessary and should be agreed on between the user and the manufacturer. Ripple control receive

33、rs are components of a system of remote control permitting the simultaneous operation of a large number of receivers from a central point. The signal generally used for this purpose is an audio-frequency voltage superimposed on the mains frequency and coded in the form of pulses, which can provide a

34、 multiplicity of control functions. Other types of signals, such as frequency modulation, deformation of the mains frequency, etc. may also be used. These signals are propagated through the electricity supply network, from the injection point to the receiver sites. Some characteristics of such syste

35、ms, for example, the value of the frequency or the method of coding, are not standardized here. To facilitate the application of this standard the following principles should be applied. 1) The requirements of this standard are not limiting. If it is absolutely unavoidable, a user can add additional

36、 technical requirements in his specification. The technical requirements and tests relate to the general functioning of the receiver. The method of operation of the functional elements is not specified. These requirements and tests may, however, be the subject of additional technical agreements. 2)

37、Ripple control systems are auxiliary equipment for network operation. Their design is determined by the network characteristics and other factors. At the present time rapid development of power electronic equipment is leading to a parallel increase in the amount of harmonic distortion in the supply

38、voltage. The harmonic levels indicated in this standard take account of this development. They are not to be considered as values that could be regarded as permissible on the network but as recommended values for designing and testing receivers. These recommended levels could be adapted to particula

39、r characteristics of networks under consideration. Receivers designed for use with transmitters already in operation and having a control frequency equal, or very close, to a harmonic, need not conform to the whole of the requirements of this standard. For information, the relevant parts of IEC 6205

40、2, IEC 62054 and IEC 62059 are listed below. IEC 62052-21 Electricity metering equipment (a.c.) General requirements, tests and test conditions Part 21: Tariff and load control equipment (Replaces the general requirements of IEC 61037 and IEC 61038.) IEC 62054-11 Electricity metering Tariff and load

41、 control Part 11: Particular requirements for electronic ripple control receivers (Replaces the particular requirements of IEC 61037.) IEC 62054-21 Electricity metering Tariff and load control Part 21: Particular requirements for time switches (Replaces the particular requirements of IEC 61038.) IEC

42、 62059-11 Electricity metering equipment Dependability Part 11: General concepts IEC 62059-21 Electricity metering equipment Dependability Part 21: Collection of meter dependability data from the field IEC 62059-41 Electricity metering equipment Dependability Part 41: Reliability prediction1 1To be

43、published. Page 4EN 6205411:2004Licensed Copy: Wang Bin, na, Mon Mar 20 06:57:28 GMT 2006, Uncontrolled Copy, (c) BSIELECTRICITY METERING (AC) TARIFF AND LOAD CONTROL Part 11: Particular requirements for electronic ripple control receivers 1 Scope This part of IEC 62054 specifies particular requirem

44、ents for the type test of newly manufactured indoor electronic ripple control receivers for the reception and interpretation of pulses of a single audio frequency superimposed on the voltage of the electricity distribution network and for the execution of the corresponding switching operations. In t

45、his system the mains frequency is generally used to synchronize the transmitter and receivers. Neither the control frequency nor the encoding are standardized in this standard. This standard gives no requirements for constructional details internal to the receiver. In the case where ripple control f

46、unctionality is integrated in multifunction electricity metering equipment, the relevant parts of this standard apply. This standard does not cover the acceptance tests and the conformity tests. Nevertheless, an example of what could be an acceptance test is given in Annex D. The dependability aspec

47、t is covered by the documents of the IEC 62059 series. When using this standard in conjunction with IEC 62052-21, the requirements of this standard take precedence over those of IEC 62052-21 with regard to any item already covered in it. 2 Normative references The following referenced documents are

48、indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 62052-21, Electricity metering equipment (a.c.) General requirements, tests and test

49、 conditions Part 21: Tariff and load control equipment 23 Terms and definitions For the purposes of this document, the definitions of IEC 62052-21 apply. 4 Standard electrical values The values given in IEC 62052-21 apply. 2To be published Page 5EN 6205411:2004Licensed Copy: Wang Bin, na, Mon Mar 20 06:57:28 GMT 2006, Uncontrolled Copy, (c) BSI5 Mechanical requirements and tests The requirements and tests specified in IEC 62052-21 and the following apply. 5.1 Opera

展开阅读全文
相关资源
猜你喜欢
  • BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf
  • BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf
  • BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf
  • BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf
  • BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf
  • BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf
  • BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf
  • BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf
  • BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1