BS ISO 12794-2000 Nuclear energy Radiation protection Individual thermoluminescence dosemeters for extremities and eyes《核能 辐射防护 肢端和眼用单独热致发光剂量计》.pdf

上传人:孙刚 文档编号:583973 上传时间:2018-12-14 格式:PDF 页数:30 大小:413.42KB
下载 相关 举报
BS ISO 12794-2000 Nuclear energy Radiation protection Individual thermoluminescence dosemeters for extremities and eyes《核能 辐射防护 肢端和眼用单独热致发光剂量计》.pdf_第1页
第1页 / 共30页
BS ISO 12794-2000 Nuclear energy Radiation protection Individual thermoluminescence dosemeters for extremities and eyes《核能 辐射防护 肢端和眼用单独热致发光剂量计》.pdf_第2页
第2页 / 共30页
BS ISO 12794-2000 Nuclear energy Radiation protection Individual thermoluminescence dosemeters for extremities and eyes《核能 辐射防护 肢端和眼用单独热致发光剂量计》.pdf_第3页
第3页 / 共30页
BS ISO 12794-2000 Nuclear energy Radiation protection Individual thermoluminescence dosemeters for extremities and eyes《核能 辐射防护 肢端和眼用单独热致发光剂量计》.pdf_第4页
第4页 / 共30页
BS ISO 12794-2000 Nuclear energy Radiation protection Individual thermoluminescence dosemeters for extremities and eyes《核能 辐射防护 肢端和眼用单独热致发光剂量计》.pdf_第5页
第5页 / 共30页
亲,该文档总共30页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | BRITISH STANDARD BS ISO 12794:2000 ICS 13.

2、280; 17.240 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW Nuclear energy Radiation protection Individual thermoluminescence dosemeters for extremities and eyesThis British Standard, having been prepared under the direction of the Engineering Sector Committee, was published u

3、nder the authority of the Standards Committee and comes into effect on 15 April 2000 BSI 04-2000 ISBN 0 580 34678 1 BS ISO 12794:2000 Amendments issued since publication Amd. No. Date Comments National foreword This British Standard reproduces verbatim ISO 12794:2000 and implements it as the UK nati

4、onal standard. The UK participation in its preparation was entrusted to Technical Committee NCE/2, Health physics instrumentation, which has the responsibility to: aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, o

5、r proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement

6、 international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport t

7、o include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover,

8、 the ISO title page, pages ii to v, a blank page, pages 1 to 20, an inside back cover and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued.Referencenumber ISO12794:2000(E) INTERNATIONAL STANDARD ISO 12794 Firstedition 2000-02-15 Nuclearene

9、rgyRadiationprotection Individualthermoluminescencedosemeters forextremitiesandeyes nergie nuclaire Radioprotection Dosimtres individuels thermoluminescents pour yeux et extrmitsISO12794:2000(E) ii ISO12794:2000(E)iii Contents Page Foreword.iv Introduction.v 1 Scope1 2 Normativereferences1 3 Termsan

10、ddefinitions.2 4 Units5 5 Generaltestconditions.5 6 Classification5 7 Performancerequirements.6 8 Testmethods6 9 Certification6 AnnexA(normative)Referenceconditionsandstandardtestconditions.8 AnnexB(normative)Confidencelimits9 AnnexC(normative)Performancetests.12 AnnexD(informative)Determinationofev

11、aluatedvalue(E)fromreadoutvalues17 AnnexE(normative)Conversiontables.18 Bibliography20ISO12794:2000(E) iv Foreword ISO(theInternationalOrganizationforStandardization)isaworldwidefederationofnationalstandardsbodies(ISO memberbodies).TheworkofpreparingInternationalStandardsisnormallycarriedoutthroughI

12、SOtechnical committees.Eachmemberbodyinterestedinasubjectforwhichatechnicalcommitteehasbeenestablishedhas therighttoberepresentedonthatcommittee.Internationalorganizations,governmentalandnon-governmental,in liaisonwithISO,alsotakepartinthework.ISOcollaboratescloselywiththeInternationalElectrotechnic

13、al Commission(IEC)onallmattersofelectrotechnicalstandardization. InternationalStandardsaredraftedinaccordancewiththerulesgivenintheISO/IECDirectives,Part3. DraftInternationalStandardsadoptedbythetechnicalcommitteesarecirculatedtothememberbodiesforvoting. PublicationasanInternationalStandardrequiresa

14、pprovalbyatleast75%ofthememberbodiescastingavote. AttentionisdrawntothepossibilitythatsomeoftheelementsofthisInternationalStandardmaybethesubjectof patentrights.ISOshallnotbeheldresponsibleforidentifyinganyorallsuchpatentrights. InternationalStandardISO12794waspreparedbyTechnicalCommitteeISO/TC85, N

15、uclear energy, SubcommitteeSC2, Radiation protection. AnnexesA,B,CandEformintegralpartsofthisInternationalStandard.AnnexDisforinformationonly.ISO12794:2000(E)v Introduction ThisInternationalStandardcoversdosemetersfortheeyesandextremities. ThisInternationalStandardshouldbeusedinconjunctionwithIEC106

16、6:1991,whichprovidesperformancecriteria andtestsforthermoluminescencedosimetrysystemscomprisingdosemeters,readers,ancillaryequipmentand proceduresforconvertinglightoutputintodose,fortheassessmentofpersonalorenvironmentaldoses,excluding extremities.Italsoincludessomeperformancecriteriaandtestsforther

17、moluminescentdetectorsand thermoluminescencedosemeterswherethesecriteriaaredependentonthecharacteristicsofthedetectorsor dosemeters,ratherthanonthereaderorancillaryequipment. ThisdocumentwaspreparedanddiscussedbyWorkingGroupWG7ofISO/TC85/SC2followingmeetingsinParis inAugust1988,MoscowinMay1990,Romei

18、nNovember1991,ParisinSeptember1992andLondoninOctober 1993.ItwasnotpossibletoholdaWGmeetinginOrlandoinOctober1994.ThedraftwasagreedattheParis meetingbytheworkinggroupandcirculatedbytheSecretariatasaCD.AfurthermeetingoftheWGwasheldin LondoninOctoberbuttheresultsofthevotingwerenotavailableuntillaterinO

19、ctober1995.Afinaldraft,dated February1996,incorporatingcommentsincludedwiththeresultsofthevotingonISO/CD(WI7-2.07.1),circulated asISO/TC85/SC2N475inOctober1993,wasagreedbyWG7inAlbuquerqueinFebruary1996.Thecomments followingcirculationasaDISwereconsideredbytheWGinJuly1997andthisInternationalStandardi

20、ncorporates thosethatwereagreedupon.INTERNATIONALSTANDARD ISO12794:2000(E)1 NuclearenergyRadiationprotectionIndividual thermoluminescencedosemetersforextremitiesandeyes 1 Scope ThisInternationalStandardprovidesperformancecriteriaandtestsfordeterminingtheperformanceof thermoluminescencedosemetersinte

21、ndedtobeusedforthemeasurementofradiationdosestotheeyesand extremities(fingers,andlimbsdefinedashands,feet,forearmsincludingtheelbow,andlegincludingthepatella),for photonsfrom15keVto3MeVandbetaradiationfrom0,5MeVto3MeV.Itisconditionalupontheuseofan appropriatereader,proceduresandancillaryequipment.It

22、doesnotcoverinformationaccessanddataprocessing. ThisInternationalStandardprovidesperformancecriteriaandtestsfordosemetersintendedtomeasuredose equivalentatdepthsof7mg cm 2 intissueforfingersandlimbsand300mg cm 2 intissuefortheeyes,including provisionfortheuseofdosemetersonlyintendedtobeusedonce.Appr

23、opriatephantomsanddoseconversion coefficientsarerecommendedbutothersarenotprecluded. Inallcases,performanceisassessedunderlaboratoryconditionswhichmaynotadequatelysimulateconditions actuallyexperiencedinpersonaldosimetry.Forexample,itmaybenecessarytosterilizedosemetersformedical applications.Therefo

24、re,cautionisnecessaryinapplyingtheresultsoftheseperformancetestsinrealsituations. 2 Normativereferences Thefollowingnormativedocumentscontainprovisionswhich,throughreferenceinthistext,constituteprovisionsof thisInternationalStandard.Fordatedreferences,subsequentamendmentsto,orrevisionsof,anyofthese

25、publicationsdonotapply.However,partiestoagreementsbasedonthisInternationalStandardareencouragedto investigatethepossibilityofapplyingthemostrecenteditionsofthenormativedocumentsindicatedbelow.For undatedreferences,thelatesteditionofthenormativedocumentreferredtoapplies.MembersofISOandIEC maintainreg

26、istersofcurrentlyvalidInternationalStandards. ISO31-0, Quantities and units Part 0: General principles. ISO4037-3:1999, X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 3: Calibration of area and per

27、sonal dosemeters and the measurement of their response as a function of energy and angle of incidence. ISO6980, Reference beta radiations for calibrating dosimeters and dose-rate meters and for determining their response as a function of beta-radiation energy.ISO12794:2000(E) 2 3 Termsanddefinitions

28、 ForthepurposesofthisInternationalStandard,thefollowingtermsanddefinitionsapply. 3.1 thermoluminescence radiothermoluminescence TL propertyexhibitedbycertainsubstances,namelytheemissionoflight,whichisinducedbyirradiationwhenthe substanceisheatedfollowingexposuretoionizingradiationorUV NOTE Strictlys

29、peaking,thepropertyshouldbereferredtoasradiothermoluminescencebuttheabbreviatedform thermoluminescenceisusuallyadequate. 3.2 thermoluminescentmaterial TLmaterial substanceexhibitingthepropertyofthermoluminescence 3.3 thermoluminescentdetector TLdetector detector specifiedquantityofTLmaterial,orsuchm

30、aterialincorporatedwithothernon-luminescentmaterialintoamatrix, definedbymass,shapeorsizeorthemassofmaterialincorporatedinthematrix 3.4 thermoluminescencedosemeter TLdosemeter dosemeter passivedeviceconsistingofoneormoreTLdetectors,whichmaybemountedinaholder(appropriateforthe application),intendedto

31、bewornonapersonsbodyorplacedinanenvironmentforthepurposeofassessingthe appropriatedoseequivalentatornearthepositionwhereitisplaced 3.5 thermoluminescencedosemeterreader TLdosemeterreader reader instrumentusedtomeasurethelightemittedfromthedetectorsinthermoluminescencedosemeters;consisting essentiall

32、yofaheatingdevice,alightmeasuringdeviceandtheassociatedelectronics 3.6 extremitydosemeter dosemeterintendedtobewornonthefingerorlimbhands,feet,forearms(includingtheelbow),andlowerleg (includingthepatella) 3.7 eyedosemeter dosemeterintendedtobewornneartheeyes 3.8 reusabledosemeter dosemeterintendedto

33、bereused,asopposedtoonewhichisdiscardedafteroneuse NOTE Whenusedinmedicalapplications,appropriatesterilizationmaybenecessary.ISO12794:2000(E)3 3.9 batch collectionofdetectorsordosemetersmadetoaspecificdesignorspecificationandintendedtohavethesame performancecharacteristicsconsistentwiththeappropriat

34、erequirementsofthisInternationalStandard 3.10 annealing controlledthermaltreatmentofaTLdetectorordosemeterduringorafterreadout 3.11 prepare reprepare normaltreatmentofannealing,cleaning,etc.whichthedosemetersordetectorsareintendedtobesubjectedtoin routineuse 3.12 readout processofmeasuringthelightem

35、ittedwhenaTLdetectorordosemeterisheatedinareader 3.13 readoutvalue m valueindicatedbyaTLreaderafterreadoutofadetectorordosemeterexpressedinunitsappropriatetotheoutputof thereader 3.14 absorbeddose D quotientof d bydm,where d isthemeanenergyimpartedbyionizingradiationtomatterofmassdm. NOTE1 Thespecia

36、lnamefortheunitofabsorbeddoseisgray(Gy)(1Gy=1Jkg 1 ).InthisInternationalStandard, absorbeddosesarespecifiedingrays. NOTE2 Wherenoambiguitycouldbeinvolved,theterm“absorbeddose“isabbreviatedto“dose“. 3.15 kerma K quotientof d tr bydm,where d tr isthesumoftheinitialkineticenergiesofallthechargedionisin

37、gparticlesliberated byunchargedionisingparticlesinamatterofmassdm: K m d d tr (1) 3.16 doseequivalent H productofD and Q at the point of interest in tissue where D is the absorbed dose and Q is the quality factor: H=DQ (2) NOTE TheSIunitforbothDand H is joule per kilogram. The special name for the u

38、nit of dose equivalent is the sievert (Sv):(1Sv=1Jkg 1 ). 3.17 personaldoseequivalent H p (d) doseequivalentinsofttissuebelowaspecifiedpointatanappropriatedepth,d NOTE TheSIunitforH p (d)isjouleperkilogram.Thespecialnameissievert(Sv)(1Sv=1Jkg 1 ).ISO12794:2000(E) 4 3.18 evaluatedvalue E valueofthequ

39、antityofinterest,e.g.doseequivalent(H),airkerma(K a ),free-airabsorbeddose(D a ), obtainedby applyingtheappropriateevaluationcoefficient(F e )tothereadoutvalueorvalues(m) 3.19 conventionaltruevalue C bestestimateofthequantityofinterestatthepointofmeasurement,e.g.doseequivalent(H),airkerma(K a ),free

40、air absorbeddose(D a ) NOTE Thisisawidelyusedstandardizedterm.ThegrammaticallycorrectsynonymoustermisConventionallyTrueValue. 3.20 evaluationcoefficient F e factororcollectionoffactors,usedtoconvertthereadoutvalueorvalues,(m),totheevaluatedvalueofinterest(E) NOTE SeeannexD. 3.21 residue readoutsigna

41、lobtainedonsecondreadoutfollowingnormalreadoutandannealingprocedures 3.22 conversioncoefficient F e factorusedtoconvertfromairkermaorfree-airabsorbeddosetothecorrespondingdoseequivalent NOTE SeeannexE. 3.23 response R quotientoftheevaluatedvalueandtheconventionaltruevalue 3.24 self-irradiation irrad

42、iationofthedetectorduetoradioactiveimpuritiescontainedinthedosemeterholderordetectoritself 3.25 phantom specifiedobjectusedtosimulatethehumanbodyorpartsthereofintermsofitsscatteringandabsorptionofgamma andbetaradiation 3.26 zeropoint evaluatedvalueofanunirradiatedprepareddosemeterordetector 3.27 rea

43、derbackground evaluatedvaluecorrespondingtothereadoutvalueobtainedwhenthereaderisoperatedwithoutadosemeteror detectorISO12794:2000(E)5 3.28 detectionthreshold minimumevaluatedvalueforwhichthereadoutvalueofadosemeterordetectorissignificantlydifferent(atthe95% confidencelevel)fromthereadoutvalueofanun

44、irradiateddosemeterordetector 3.29 coefficientofvariation ratioofthestandarddeviations,tothearithmeticmean xofasetofnmeasurementsx i ;isgvenbythefollowing formula: V s xxn xx i i n 11 1 2 1 bg (3) NOTE Thecoefficientofvariationisgenerallyexpressedasapercentage. 3.30 qualitycontroltest QT testperform

45、edonanumberofTLdosemetersystems,dosemeters,detectorsorreadersofagivenbatchorproduction designedtoassurequalitycontrol 3.31 typetest TT testperformedonasmallnumberofTLdosemetersystems,dosemeters,detectorsorreadersofagiventypeto determineperformancecharacteristicsofthattype 4Units ThisInternationalSta

46、ndardusesSIunits.However,thefollowingunitsofpracticalimportancefortimeareusedwhere necessary:days(d),hours(h).ThesymbolsoftheunitsfortimeareprovidedbyInternationalStandardISO31-0. 5 Generaltestconditions 5.1 Testconditions Alltestsshallbeperformedunderstandardtestconditions(seeannexA),exceptwhereoth

47、erwisestated.Dosemeters shallbesubjectedtotheannealing,cleaningandhandlingprocedureswhicharerecommendedbythemanufacturer. 5.2 Referenceradiations TheradiationsourcesspecifiedinISO4037-3andISO6980shallbeusedinthemannerspecifiedinthese InternationalStandards.Photonreferenceradiationsusedforspectralres

48、ponsechecksshallbechosenfromthefirst columnoftable1in4ofISO4037-3:1999.Sourcesforbetaspectralresponseshallbe 90 Sr(inequilibriumwith 90 Y), 106 Ru,and 204 Tl.Calibrationofradiationsourcesshallbetraceabletotheappropriateprimaryorsecondarystandards. 6 Classification Dosemetersshallbeclassifiedinaccord

49、ancewithbodypartandthedepthofintendedmeasurement,andmethodof intendeduseviz: F(7)D Finger,depth7mg cm 2 ,disposable; F(7)R Finger,depth7mg cm 2 ,re-usable;ISO12794:2000(E) 6 L(7)D Limb,depth7mg cm 2 ,disposable; L(7)R Limb,depth7mg cm 2 ,re-usable; E(300)D Eye,depth300mg cm 2 ,disposable; E(300)R Eye,depth300mg cm 2 ,re-usable. 7 Performancerequirements TheperformancecriteriaarelistedinTable1.Alldosevalueslistedinthecriteriaareintermsofdoseequivalentto tissueattheintendeddepthofmeasurement * .Theconventionaltru

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
  • BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf
  • BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf
  • BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf
  • BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf
  • BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf
  • BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf
  • BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf
  • BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf
  • BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1