1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS ISO 6722-1:2011Road vehicles 60 V and 600 V single-core cablesPart 1: Dimensions, test methods and requirements for copper conductor cablesIncorporating Corrigendum September
2、2012BS ISO 6722-1:2011National forewordThis British Standard is the UK implementation of ISO 6722-1:2011, incorporating corrigendum September 2012. It supersedes BS ISO 6722:2006, which is withdrawn.The start and finish of text introduced or altered by corrigendum is indicated in the text by tags. T
3、ext altered by ISO corrigendum September 2012 is indicated in the text by .The UK participation in its preparation was entrusted to Technical Committee AUE/16, Electrical and electronic equipment.A list of organizations represented on this committee can be obtained on request to its secretary.This p
4、ublication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2013. Published by BSI Standards Limited 2013.ISBN 978 0 580 80834 0 ICS 43.040.10 Compliance with a British Standard cannot confer
5、immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 October 2011.Amendments/corrigenda issued since publicationDate Text affected31 January 2013 Implementation of ISO corrigendum September 2012BRITISH STANDARDRe
6、ference numberISO 6722-1:2011(E)ISO 2011INTERNATIONAL STANDARD ISO6722-1Fourth edition2011-10-15Road vehicles 60 V and 600 V single-core cables Part 1: Dimensions, test methods and requirements for copper conductor cables Vhicules routiers Cbles monoconducteurs de 60 V et 600 V Partie 1: Dimensions,
7、 mthodes dessai et exigences pour les cbles conducteurs en cuivre COPYRIGHT PROTECTED DOCUMENT ISO 2011 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfi
8、lm, without permission in writing from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Case postale 56 g120 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland ii BS
9、ISO 6722-1:2011 ISO 6722-1:2011 (E) ISO 2012iiiContents Page Foreword ivg31g3 Scope 1g32g3 Normative references 1g33g3 Terms and definitions . 2g34g3 General . 2g34.1g3 Safety concerns . 2g34.2g3 Temperature classes . 2g34.3g3 Conductors 3g34.4g3 Tests . 3g34.5g3 General test conditions. 5g34.6g3 Ov
10、ens 5g34.7g3 Representative conductor sizes for testing 5g34.8g3 Recommended colours . 5g35g3 Tests and requirements 5g35.1g3 Outside cable diameter . 5g35.2g3 Insulation thickness 6g35.3g3 Conductor diameter 8g35.4g3 Conductor resistance 8g35.5g3 Withstand voltage 10g35.6g3 Insulation faults . 11g3
11、5.7g3 Insulation volume resistivity 12g35.8g3 Pressure test at high temperature . 13g35.9g3 Strip force . 14g35.10g3 Low temperature winding . 15g35.11g3 Cold impact 17g35.12g3 Abrasion test 19g35.13g3 Long term heat ageing, 3 000 h 23g35.14g3 Short term heat ageing, 240 h 24g35.15g3 Thermal overloa
12、d . 25g35.16g3 Shrinkage by heat 26g35.17g3 Fluid compatibility . 26g35.18g3 Durability of cable marking 30g35.19g3 Resistance to ozone 30g35.20g3 Resistance to hot water 31g35.21g3 Temperature and humidity cycling 33g35.22g3 Resistance to flame propagation . 34g3Annex A (informative) Comparison tem
13、perature class rating 36g3Annex B (informative) Construction . 37g3Annex C (informative) Recommended colours 40g3Annex D (informative) Sources for reference materials 41g3Bibliography 42g3BS ISO 6722-1:2011 ISO 6722-1:2011 (E) ISO 2012iv Foreword ISO (the International Organization for Standardizati
14、on) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be re
15、presented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards
16、are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an Internati
17、onal Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 6722-1 was
18、prepared by Technical Committee ISO/TC 22, Road vehicles, Subcommittee SC 3, Electrical and electronic equipment. This fourth edition of ISO 6722-1 cancels and replaces ISO 6722:2006, which has been technically revised. ISO 6722 consists of the following parts, under the general title Road vehicles
19、60 V and 600 V single-core cables: g127 Part 1: Dimensions, test methods and requirements for copper conductor cables g127 Part 2: Dimensions, test methods and requirements for aluminium conductor cables1)1) To be published. BS ISO 6722-1:2011 ISO 6722-1:2011 (E) ISO 2012INTERNATIONAL STANDARD 1Road
20、 vehicles 60 V and 600 V single-core cables Part 1: Dimensions, test methods and requirements for copper conductor cables WARNING The use of this International Standard may involve hazardous materials, operations, and equipment. This International Standard does not purport to address all of the safe
21、ty concerns, if any, associated with its use. It is the responsibility of the user of this International Standard to establish appropriate safety practices and determine the applicability of regulatory limitations prior to use. 1 Scope This part of ISO 6722 specifies the dimensions, test methods, an
22、d requirements for single-core 60 V cables intended for use in road vehicle applications where the nominal system voltage is g100 (60 V d.c. or 25 V a.c.). It also specifies additional test methods and/or requirements for 600 V cables intended for use in road vehicle applications where the nominal s
23、ystem voltage is greater than g33 (60 V d.c. or 25 V a.c.) to g100 (600 V d.c. or 600 V a.c.). It also applies to individual cores in multi-core cables. This part of ISO 6722 specifies requirements for copper conductor cables. 2 Normative references The following referenced documents are indispensab
24、le for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 1817, Rubber, vulcanized or thermoplastic Determination of the effect of liquids ISO 6931-1, St
25、ainless steels for springs Part 1: Wire IEC 60811-2-1, Common test methods for insulating and sheathing materials of electric and optical cables Part 2-1: Methods specific to elastomeric compounds Ozone resistance, hot set and mineral oil immersion tests ASTM B1, Standard Specification for Hard Draw
26、n Copper Wire ASTM B3, Standard Specification for Soft or Annealed Copper Wire ASTM B33, Standard Specification for Tin Coated Soft or Annealed Copper Wire for Electrical Purposes ASTM B298, Standard Specification for Silver Coated Soft or Annealed Copper Wire ASTM B355, Standard Specification for N
27、ickel Coated Soft or Annealed Copper Wire EN 13602, Copper and copper alloys Drawn, round copper wire for the manufacture of electrical conductors BS ISO 6722-1:2011 ISO 2012ISO 6722-1:2011 (E)2 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. NOT
28、E Whenever a.c. voltage is specified throughout this part of ISO 6722, a.c. rms value shall be used. 3.1 60 volt (V) cable cable intended for use in road vehicle applications where the nominal system voltage is equal to or less than (60 V d.c. or 25 V a.c.) 3.2 600 volt (V) cable cable intended for
29、use in road vehicle applications where the nominal system voltage is greater than (60 V d.c. or 25 V a.c.) and less than or equal to (600 V d.c. or 600 V a.c.) 3.3 cable family group with multiple conductor sizes having the same conductor strand coating, insulation formulation, and wall thickness ty
30、pe 3.4 nominal (value) suitable approximate value used to designate or identify a component 4 General 4.1 Safety concerns See the “Warning” notice at the beginning of this International Standard. 4.2 Temperature classes Eight temperature classes are defined in Table 1. Table 1 Temperature class rati
31、ng Class Temperature A g1640 C to 85 C B g1640 C to 100 C C g1640 C to 125 C D g1640 C to 150 C E g1640 C to 175 C F g1640 C to 200 C G g1640 C to 225 C H g1640 C to 250 C BS ISO 6722-1:2011 ISO 6722-1:2011 (E) ISO 201234.3 Conductors The conductors shall consist of plain or coated copper strands as
32、 shown in Table 2. Conductor sizes g116 0,5 mm2shall consist of soft annealed copper or annealed compressed/compacted wires. Conductor sizes g31 0,5 mm2shall consist of soft annealed copper, soft annealed compressed/compacted copper, hard unannealed copper, or a copper alloy. The specifications for
33、the conductors shall be completed by material specifications. Elongation requirements shall be established by agreement between customer and supplier. The finished cable shall meet the resistance requirements of Table 5 for all conductors except alloys. When an alloy is used, the resistance requirem
34、ent shall be established by agreement between customer and supplier. NOTE Examples of strandings are shown in Table B.1. These strandings highlight examples of conceptual configurations and are not intended to reflect any preferred constructions. Other strandings configurations may be used provided
35、they meet the requirements specified above and are agreed between customer and supplier. Table 2 Conductor specifications ASTM B1 Hard-drawn copper wire ASTM B3 or EN 13602 Soft or annealed copper wire ASTM B33 or EN 13602 Tin-coated soft or annealed copper wire ASTM B298 Silver-coated soft or annea
36、led copper wire ASTM B355 Nickel-coated soft or annealed copper wire NOTE Silver and Nickel coated conductors are intended for use with high “temperature class ratings”. 4.4 Tests The cables shall be submitted to the tests as specified in Table 3. NOTE A special set of requirements for trucks is int
37、ended to be added to the next revision of this International Standard. BS ISO 6722-1:2011 ISO 6722-1:2011 (E) ISO 20124 Table 3 Tests Sub-clause Test description Mandatory If requiredc In progressa Initial Periodicb Initial Periodic 5.1 Outside cable diameter X X 5.2 Insulation thickness X X 5.3 Con
38、ductor diameter X X 5.4 Conductor resistance X X 5.5 Withstand voltage Note 1 Note 1 5.6 Insulation faults Note 1 5.7 Insulation volume resistivity X X 5.8 Pressure test at high temperature X X 5.9 Strip force X X 5.10 Low temperature winding X X 5.11 Cold impact X X 5.12 Abrasion test Note 2 Note 2
39、 5.13 Long term heat ageing, 3 000 h X 5.14 Short term heat ageing, 240 h X X 5.15 Thermal overload X X 5.16 Shrinkage by heat X X 5.17 Fluid compatibility Notes 3 and 4 Notes 3 and 4 5.18 Durability of cable marking Note 4 Note 4 5.19 Resistance to ozone Note 4 5.20 Resistance to hot water Note 4 5
40、.21 Temperature and humidity cycling Note 4 5.22 Resistance to flame propagation X X NOTE 1 Some cables are rated at 60 V and others at 600 V. See 5.5.3 and 5.6.3 for details. NOTE 2 See 5.12. NOTE 3 Some fluids are for “Certification” and others are “If required”. See 5.17 for details. NOTE 4 Compl
41、iance for a cable family may be demonstrated by testing examples of large and small conductor sizes only. See 4.7 for details. aA test made on an entire cable length during or after the manufacture. bThe frequency of periodic testing shall be established by agreement between customer and supplier. c
42、The usage of “If required” tests shall be established by agreement between customer and supplier. BS ISO 6722-1:2011 ISO 6722-1:2011 (E) ISO 201254.5 General test conditions Unless specified otherwise, the device under test (DUT) shall be preconditioned for at least 16 h at a room temperature (RT) o
43、f (23 g114 5) C and a relative humidity (RH) of 45 % to 75 %. Unless specified otherwise, all tests other than “In process” tests shall be conducted at these conditions. Where no tolerance is specified, all values shall be considered to be approximate. When a.c. tests are performed, they shall be at
44、 50 Hz or 60 Hz. Applications at higher frequencies may require additional testing. 4.6 Ovens An oven with air exchange, either natural or by pressure, should be used. The air shall enter the oven in such a way that it flows over the surface of the test pieces and exits near the top of the oven. The
45、 oven shall have not less than 8 and not more than 20 complete air changes per hour at the specified ageing temperature. Forced air circulation, e.g. by a fan inside the oven may be used. However, in case of dispute, an oven without forced air circulation shall be used. 4.7 Representative conductor
46、sizes for testing When a test is required, all combinations of conductor size, wall thickness, and insulation formulation shall meet the appropriate requirements. However, if testing of representative conductor sizes is permitted (see Table 3), compliance for a cable family may be demonstrated by te
47、sting examples of large and small conductor sizes only. Permission to show compliance for a cable family by testing “representative conductor sizes” shall be established by agreement between customer and supplier. 4.8 Recommended colours A list of recommended colours is shown in Table C.1. 5 Tests a
48、nd requirements 5.1 Outside cable diameter 5.1.1 Purpose This test is intended to verify that the cable outside diameter is within the required tolerances to fit seal and harness dimension requirements. 5.1.2 Test Sample Prepare a test sample of 3 m in length. 5.1.3 Test Use a measuring device which
49、 shall not cause deformation. Take three sets of measurements at positions separated by 1 m and record the highest and lowest outside cable diameter at each position. BS ISO 6722-1:2011 ISO 6722-1:2011 (E) ISO 20126 5.1.4 Requirement All measurements shall be within the limits of the appropriate maximum and minimum “outside cable diameter” specified in Table 4 and Table B.2. The v