CAN CSA-ISO IEC 15018-2005 Information technology – Generic cabling for homes.pdf

上传人:Iclinic170 文档编号:590581 上传时间:2018-12-15 格式:PDF 页数:89 大小:677.81KB
下载 相关 举报
CAN CSA-ISO IEC 15018-2005 Information technology – Generic cabling for homes.pdf_第1页
第1页 / 共89页
CAN CSA-ISO IEC 15018-2005 Information technology – Generic cabling for homes.pdf_第2页
第2页 / 共89页
CAN CSA-ISO IEC 15018-2005 Information technology – Generic cabling for homes.pdf_第3页
第3页 / 共89页
CAN CSA-ISO IEC 15018-2005 Information technology – Generic cabling for homes.pdf_第4页
第4页 / 共89页
CAN CSA-ISO IEC 15018-2005 Information technology – Generic cabling for homes.pdf_第5页
第5页 / 共89页
亲,该文档总共89页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、 Information technology Generic cabling for homes Reference number ISO/IEC 15018:2004(E) National Standard of CanadaCAN/CSA-ISO/IEC 15018:05(ISO/IEC 15018:2004)International Standard ISO/IEC 15018:2004 (first edition, 2004-06) has been adopted withoutmodification (IDT) as CSA Standard CAN/CSA-ISO/IE

2、C 15018:05, which has been approved as a NationalStandard of Canada by the Standards Council of Canada.ISBN 1-55397-959-1 October 2005The Canadian Standards Association (CSA), under whose auspices this National Standard has been produced, was chartered in 1919 and accredited by the Standards Council

3、 of Canada to the National Standards system in 1973. It is a not-for-profit, nonstatutory, voluntary membership association engaged in standards development and certification activities. CSA standards reflect a national consensus of producers and users including manufacturers, consumers, retailers,

4、unions and professional organizations, and governmental agencies. The standards are used widely by industry and commerce and often adopted by municipal, provincial, and federal governments in their regulations, particularly in the fields of health, safety, building and construction, and the environm

5、ent. Individuals, companies, and associations across Canada indicate their support for CSAs standards development by volunteering their time and skills to CSA Committee work and supporting the Associations objectives through sustaining memberships. The more than 7000 committee volunteers and the 200

6、0 sustaining memberships together form CSAs total membership from which its Directors are chosen. Sustaining memberships represent a major source of income for CSAs standards development activities. The Association offers certification and testing services in support of and as an extension to its st

7、andards development activities. To ensure the integrity of its certification process, the Association regularly and continually audits and inspects products that bear the CSA Mark. In addition to its head office and laboratory complex in Toronto, CSA has regional branch offices in major centres acro

8、ss Canada and inspection and testing agencies in eight countries. Since 1919, the Association has developed the necessary expertise to meet its corporate mission: CSA is an independent service organization whose mission is to provide an open and effective forum for activities facilitating the exchan

9、ge of goods and services through the use of standards, certification and related services to meet national and international needs.For further information on CSA services, write toCanadian Standards Association5060 Spectrum Way, Suite 100Mississauga, Ontario, L4W 5N6CanadaThe Standards Council of Ca

10、nada is the coordinating body of the National Standards system, a federation of independent, autonomous organizations working towards the further development and improvement of voluntary standardization in the national interest. The principal objects of the Council are to foster and promote voluntar

11、y standardization as a means of advancing the national economy, benefiting the health, safety, and welfare of the public, assisting and protecting the consumer, facilitating domestic and international trade, and furthering international cooperation in the field of standards. A National Standard of C

12、anada is a standard which has been approved by the Standards Council of Canada and one which reflects a reasonable agreement among the views of a number of capable individuals whose collective interests provide to the greatest practicable extent a balance of representation of producers, users, consu

13、mers, and others with relevant interests, as may be appropriate to the subject in hand. It normally is a standard which is capable of making a significant and timely contribution to the national interest. Approval of a standard as a National Standard of Canada indicates that a standard conforms to t

14、he criteria and procedures established by the Standards Council of Canada. Approval does not refer to the technical content of the standard; this remains the continuing responsibility of the accredited standards development organization. Those who have a need to apply standards are encouraged to use

15、 National Standards of Canada whenever practicable. These standards are subject to periodic review; therefore, users are cautioned to obtain the latest edition from the organization preparing the standard.The responsibility for approving National Standards of Canada rests with theStandards Council o

16、f Canada270 Albert Street, Suite 200Ottawa, Ontario, K1P 6N7CanadaAlthough the intended primary application of this Standard is stated in its Scope, it is importantto note that it remains the responsibility of the users to judge its suitability for their particular purpose.Registered trade-mark of C

17、anadian Standards AssociationCette norme est offerte en anglais seulement pour le moment. La CSA publiera la version enfranais ds quelle sera produite par lorganisme rdacteur.CAN/CSA-ISO/IEC 15018:05 Information technology Generic cabling for homesOctober 2005 Canadian Standards Association CSA/1CAN

18、/CSA-ISO/IEC 15018:05Information technology Generic cabling for homesCSA PrefaceStandards development within the Information Technology sector is harmonized with international standards development. Through the CSA Technical Committee on Information Technology (TCIT), Canadians serve as the Canadian

19、 Advisory Committee (CAC) on ISO/IEC Joint Technical Committee 1 on Information Technology (ISO/IEC JTC1) for the Standards Council of Canada (SCC), the ISO member body for Canada and sponsor of the Canadian National Committee of the IEC. Also, as a member of the International Telecommunication Unio

20、n (ITU), Canada participates in the International Telegraph and Telephone Consultative Committee (ITU-T).At the time of publication, ISO/IEC 15018:2004 is available from ISO and IEC in English only. CSA will publish the French version when it becomes available from ISO and IEC.This International Sta

21、ndard was reviewed by the CSA TCIT under the jurisdiction of the Strategic Steering Committee on Information Technology and deemed acceptable for use in Canada. (A committee membership list is available on request from the CSA Project Manager.) From time to time, ISO/IEC may publish addenda, corrige

22、nda, etc. The CSA TCIT will review these documents for approval and publication. For a listing, refer to the CSA Information Products catalogue or CSA Info Update or contact a CSA Sales representative. This Standard has been formally approved, without modification, by the Technical Committee and has

23、 been approved as a National Standard of Canada by the Standards Council of Canada.October 2005 Canadian Standards Association 2005All rights reserved. No part of this publication may be reproduced in any form whatsoever without the prior permission ofthe publisher. ISO/IEC material is reprinted wit

24、h permission. Where the words “this International Standard” appear in the text, they should be interpreted as “this National Standard of Canada”.Inquiries regarding this National Standard of Canada should be addressed toCanadian Standards Association5060 Spectrum Way, Suite 100, Mississauga, Ontario

25、, Canada L4W 5N61-800-463-6727 416-747-4044www.csa.caINTERNATIONAL STANDARD ISO/IEC15018First edition2004-06Information technology Generic cabling for homes Reference number ISO/IEC 15018:2004(E) INTERNATIONAL STANDARD ISO/IEC15018First edition2004-06Information technology Generic cabling for homes

26、PRICE CODE ISO/IEC 2004 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher. ISO/IEC Copyright Office C

27、ase postale 56 CH-1211 Genve 20 Switzerland W For price, see current catalogue 2 15018 ISO/IEC:2004(E)CONTENTSPageFOREWORD 7Introduction 81 Scope 112 Normative references .113 Definitions and abbreviations 143.1 Definitions .143.2 Abbreviations 184 Conformance195 Structure of the generic cabling sys

28、tem to support ICT and/or BCT applications.205.1 General .205.2 Functional elements.205.3 Cabling subsystems for ICT and BCT.205.3.1 General .205.3.2 Primary home cabling subsystem .225.3.3 Secondary home cabling subsystem.235.4 Cabling structure for ICT and BCT applications 235.5 Interfaces 245.5.1

29、 Equipment interfaces and test interfaces 245.5.2 Channel and permanent link.255.5.3 Network access cabling265.5.4 External network interface275.6 Accommodation of functional elements 275.6.1 Distributors 275.6.2 Application outlets285.6.3 Cable pathways .295.7 Dimensioning and configuring 295.7.1 D

30、istributors 295.7.2 Application outlets305.7.3 Equipment cords 315.7.4 Building entrance facilities316 Cabling to support CCCB applications.316.1 General .316.2 Functional elements.316.3 Cabling subsystems for CCCB .326.3.1 General .326.3.2 Area feeder cabling subsystem.326.3.3 Coverage area cabling

31、 subsystem 336.4 Cabling structure for CCCB applications.346.5 Interfaces 346.5.1 Equipment interfaces and test interfaces 346.5.2 Channel and permanent link.356.5.3 Network access cabling366.5.4 External network interface3615018 ISO/IEC:2004(E) 3 6.6 Accommodation of functional elements 376.6.1 Are

32、a connection points (ACPs).376.6.2 Control outlets (COs) .376.6.3 Cable pathways .376.7 Dimensioning and configuring 376.7.1 Distributors 376.7.2 Control outlet (CO).376.7.3 Cable sharing 386.7.4 Equipment cords 386.7.5 Building entrance facilities387 Performance.387.1 General .387.2 ICT channel per

33、formance.407.3 BCT channel performance .407.4 CCCB channel performance.438 Reference implementation 458.1 General .458.2 Cabling assumptions .458.2.1 Introduction .458.2.2 General .458.2.3 Dimensions for ICT and BCT channels .478.2.4 Dimensions for CCCB channels489 Cable requirements 499.1 General .

34、499.2 Cable performance for ICT.499.3 Cable performance for BCT .519.3.1 Requirements for balanced pairs for BCT .519.3.2 Requirements for coaxial cables for BCT 529.4 Cable performance for CCCB coverage area 5410 Connecting hardware5610.1 General requirements 5610.1.1 Applicability .5610.1.2 Locati

35、on.5610.1.3 Design.5610.1.4 Operating environment.5710.1.5 Mounting .5710.1.6 Installation practices 5710.1.7 Marking and colour coding .5710.2 Mating interfaces at TO, BO and CO 5810.2.1 General .5810.2.2 Mating interface for TO 5810.2.3 Mating interface for BO 5810.2.4 Mating interface for CO 5910

36、.2.5 Minimum performance requirements.5911 Safety requirements and screening practices 6511.1 General .65 4 15018 ISO/IEC:2004(E)11.2 Coexistence with mains .6511.3 Operational safety .6511.4 Screening practices .6611.4.1 General .6611.4.2 Earthing.66Annex A (normative) BCT channel levels67Annex B (

37、normative) Link performance.68B.1 General68B.2 Performance requirements for ICT permanent links .68B.3 Performance requirements for BCT permanent links69B.4 Performance requirements for CCCB permanent links .71Annex C (informative ) BCT levels: channel and link performance and implementation 72C.1 G

38、eneral72C.2 BCT-H, BCT-M and BCT-L channels .72C.3 BCT-H, BCT-M and BCT-L links74C.4 BCT levels implementation.76C.4.1 General .76C.4.2 Cable specifications .76C.4.3 Connecting hardware specifications76C.4.4 Maximum channel lengths for reference implementations76C.4.5 Channel lengths using other coa

39、xial cable specifications 77C.4.6 Channel lengths using other balanced cable specifications .77Annex D (informative) Applications and associated cabling.78Bibliography .81Figure 1 Overview of a generic cabling for home 9Figure 2 Structure of the generic cabling system.21Figure 3 Interconnect and cro

40、ss-connect models 22Figure 4 Hierarchical structure of a generic cabling system in support of ICT andBCT applications 23Figure 5 Equipment and test interfaces in support of ICT and BCT applications.24Figure 6 Channels and permanent links within the home.26Figure 7 Examples of interconnection of home

41、 and network access cabling.27Figure 8 Interconnection of home cabling subsystems 29Figure 9 Structure of the generic cabling system in support of CCCB applications .32Figure 10 Hierarchical structure of a generic cabling system in support of CCCBapplications 34Figure 11 Equipment and test interface

42、s in support of CCCB applications .35Figure 12 Channels and permanent links for CCCB cabling.36Figure 13 Reference implementations for ICT and BCT channels (PHD/SHD -TO/BO).47Figure 14 Reference implementations for CCCB channels with PHD or SHD .48Figure 15 Reference implementations for CCCB channel

43、s with PHD and SHD.49Figure 16 Pin grouping assignments for IEC 60603-7 series outlet (front view) 5815018 ISO/IEC:2004(E) 5 Figure 17 Pin grouping assignments for 61076-3-104 outlet (front view)59Figure 18 Pin grouping assignments for IEC 60603-7-7 outlet (front view) .59Figure 19 Conductor assignm

44、ent of IEC 61169-2 and IEC 61169-24 (Type F)connector .59Table 1 Maximum channel lengths for reference implementations of ICT/BCTchannels.30Table 2 Different channels and their potential use 39Table 3 Minimum performance of BCT-B channels41Table 4 Minimum performance of BCT-C channels42Table 5 Minim

45、um performance of CCCB copper channels for information transfer .44Table 6 Minimum performance of CCCB channels for d.c. power feeding 44Table 7 Link length equations.46Table 8 Mechanical performance requirements for ICT and balanced BCT cables .50Table 9 Minimum transmission performance requirement

46、s BCT balanced pairs .51Table 10 Minimum electrical performance requirements for BCT coaxial cable 52Table 11 Mechanical performance requirements for coaxial BCT cables53Table 12 Minimum transmission performance requirements for CCCB coverage areacables 54Table 13 Mechanical performance requirements

47、 for balanced CCCB coverage areacables 55Table 14 Mechanical characteristics of connecting hardware for use with balancedcabling .61Table 15 Return loss (RL) 62Table 16 Insertion loss.63Table 17 Near end crosstalk (NEXT) 63Table 18 Far end crosstalk (FEXT).63Table 19 Input to output resistance 64Tab

48、le 20 Current carrying capacity .64Table 21 Propagation delay64Table 22 Coupling and screening attenuation .64Table 23 Insulation resistance65Table 24 Voltage proof.65Table A.1 BCT channels division 67Table B.1 Minimum performance of BCT-B permanent links 69Table B.2 Minimum performance of BCT-C per

49、manent links70Table C.1 Minimum insertion loss of BCT_B channels for BCT-H, BCT-M and BCT-L 73Table C.2 Minimum insertion loss of BCT-C channels for BCT-H, BCT-M and BCT-L.74Table C.3 Insertion loss for BCT-B permanent links 75Table C.4 Insertion loss for BCT-C permanent links75Table C.5 BCT-L, BCT-M and BCT-H channel implementations.77 6 15018 ISO/IEC:2004(E)Table D.1 Grouping of applications and cabling 78Table D.2 Characteristi

展开阅读全文