1、CAN/CGSB3.0No. 19.52011Supersedes CAN/CGSB-3.0 No. 19.5-2004Methods of Testing Petroleum and Associated ProductsDetermination of Lead in Automotive Gasoline (Atomic Absorption)ICS 71.040.50National Standard of CanadaCopyright Canadian General Standards Board Provided by IHS under license with CGSBNo
2、t for ResaleNo reproduction or networking permitted without license from IHS-,-,-The CANADIAN GENERAL STANDARDS BOARD (CGSB), under whose auspices this National Standard of Canada has been developed is a government agency within Public Works and Government Services Canada. CGSB is engaged in the pro
3、duction of voluntary standards in a wide range of subject areas through the media of standards committees and the consensus process. The standards committees are composed of representatives of relevant interests including producers, consumers and other users, retailers, governments, educational inst
4、itutions, technical, professional and trade societies, and research and testing organizations. Any given standard is developed on the consensus of views expressed by such representatives. CGSB has been accredited by the Standards Council of Canada as a national standards-development organization. Th
5、e standards that it develops and offers as National Standards of Canada conform to the criteria and procedures established for this purpose by the Standards Council of Canada. In addition to standards it publishes as national standards, CGSB produces standards to meet particular needs, in response t
6、o requests from a variety of sources in both the public and private sectors. Both CGSB standards and CGSB national standards are developed in conformance with the policies described in the CGSB Policy Manual for the Development and Review of Standards. CGSB standards are subject to review and revisi
7、on to ensure that they keep abreast of technological progress. Suggestions for their improvement, which are always welcome, should be brought to the notice of the standards committees concerned. Changes to standards are issued either as separate amendment sheets or in new editions of standards. An u
8、p-to-date listing of CGSB standards, including details on latest issues and amendments, and ordering instructions, is found in the CGSB Catalogue, which is published annually and is available without charge upon request. More information is available about CGSB products and services at our Web site
9、www.ongc-cgsb.gc.ca. Although the intended primary application of this standard is stated in its Scope, it is important to note that it remains the responsibility of the users of the standard to judge its suitability for their particular purpose. The testing and evaluation of a product against this
10、standard may require the use of materials and/or equipment that could be hazardous. This document does not purport to address all the safety aspects associated with its use. Anyone using this standard has the responsibility to consult the appropriate authorities and to establish appropriate health a
11、nd safety practices in conjunction with any applicable regulatory requirements prior to its use. CGSB neither assumes nor accepts any responsibility for any injury or damage that may occur during or as the result of tests, wherever performed. Attention is drawn to the possibility that some of the el
12、ements of this Canadian standard may be the subject of patent rights. CGSB shall not be held responsible for identifying any or all such patent rights. Users of this standard are expressly advised that determination of the validity of any such patent rights is entirely their own responsibility. Furt
13、her information on CGSB and its services and standards may be obtained from: The Manager Standards Division Canadian General Standards Board Gatineau, Canada K1A 1G6 The STANDARDS COUNCIL OF CANADA is the coordinating body of the National Standards System, a coalition of independent, autonomous orga
14、nizations working towards the further development and improvement of voluntary standardization in the national interest. The principal objects of the SCC are to foster and promote voluntary standardization as a means of advancing the national economy, benefiting the health, safety and welfare of the
15、 public, assisting and protecting the consumer, facilitating domestic and international trade, and furthering international cooperation in the field of standards. A National Standard of Canada (NSC) is a standard prepared or reviewed by an accredited Standards Development Organization (SDO) and appr
16、oved by the SCC according to the requirements of CAN-P-2. Approval does not refer to the technical content of the standard; this remains the continuing responsibility of the SDO. A NSC reflects a consensus of a number of capable individuals whose collective interests provide, to the greatest practic
17、able extent, a balance of representation of general interests, producers, regulators, users (including consumers), and others with relevant interests, as may be appropriate to the subject in hand. It normally is a standard, which is capable of making a significant and timely contribution to the nati
18、onal interest. Those who have a need to apply standards are encouraged to use NSCs. These standards are subject to periodic review. Users of NSCs are cautioned to obtain the latest edition from the SDO, which publishes the standard. The responsibility for approving standards as National Standards of
19、 Canada rests with the: Standards Council of Canada 200-270 Albert Street Ottawa, Ontario K1P 6N7 How to order Publications: by telephone 819-956-0425 or 1-800-665-2472 by fax 819-956-5740 by mail CGSB Sales Centre Gatineau, Canada K1A 1G6 in person Place du Portage Phase III, 6B1 11 Laurier Street
20、Gatineau, Quebec by email ncr.cgsb-ongcpwgsc.gc.ca on the Web www.ongc-cgsb.gc.ca Copyright Canadian General Standards Board Provided by IHS under license with CGSBNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NATIONAL STANDARD OF CANADA CAN/CGSB3.0 No. 19.52011S
21、upersedes CAN/CGSB-3.0 No. 19.5-2004METHODS OF TESTING PETROLEUM AND ASSOCIATED PRODUCTS DETERMINATION OF LEAD IN AUTOMOTIVE GASOLINE (ATOMIC ABSORPTION)CETTE NORME NATIONALE DU CANADA EST DISPONIBLE EN VERSIONSFRANAISE ET ANGLAISE.NATIONAL STANDARD OF CANADA CAN/CGSB3.142006Prepared by the Approved
22、 by the Canadian General Standards Board Standards Council of CanadaPublished May 2011 by the Canadian General Standards Board Gatineau, Canada K1A 1G6 HER MAJESTY THE QUEEN IN RIGHT OF CANADA, as represented by the Minister of Public Works and Government Services, the Minister responsible for the C
23、anadian General Standards Board (2011). No part of this publication may be reproduced in any form without the prior permission of the publisher.Copyright Canadian General Standards Board Provided by IHS under license with CGSBNot for ResaleNo reproduction or networking permitted without license from
24、 IHS-,-,-CANADIAN GENERAL STANDARDS BOARDCOMMITTEE ON PETROLEUM TEST METHODS(Voting membership at date of approval)ChairWispinski, D. Alberta Innovates Technology Futures (User)General Interest CategoryMnard, L. Advanced Engine Technology Ltd.Snow, M. PerkinElmerSt-Laurent, A. Canadian Coast GuardPr
25、oducer CategoryBoroniec, J. Suncor EnergyBoulton, L. Husky EnergyFalkiner, R.J. Imperial OilPorter, S. Canadian Renewable Fuels AssociationRiel, K. Shell Canada Ltd.Samiullah, M. Sentinel CanadaWhite, M. North AtlanticRegulator CategoryTardif, M. Environment CanadaUser CategoryJacula, T. Maxxam Anal
26、yticsLam, M. National DefenceMacDonald, P. Natural Resources CanadaMcRae, M. SGS Canada Inc.Squires, B. OTI Canada GroupVidian-Jones, C. Certispec Services Inc.Secretary (Nonmember)Newman, M. Canadian General Standards BoardAcknowledgment is made for the translation of this National Standard of Cana
27、da by the Translation Bureau of Public Works and Government Services Canada.CAN/CGSB3.0 No. 19.52011Copyright Canadian General Standards Board Provided by IHS under license with CGSBNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-No. 19.52011 1CAN/CGSB3.0 No. 19.52
28、011Supersedes CAN/CGSB-3.0 No. 19.5-2004CANADIAN GENERAL STANDARDS BOARDMETHODS OF TESTING PETROLEUM AND ASSOCIATED PRODUCTSDetermination of Lead in Automotive Gasoline (Atomic Absorption)1. SCOPE1.1 This method is used to determine the lead content of gasolines, including those containing ethanol.
29、Lead in the range of 1 to 1100 mg/L can be measured.1.2 The testing and evaluation of a product against this method may require the use of materials and/or equipment that could be hazardous. This document does not purport to address all the safety aspects associated with its use. Anyone using this m
30、ethod has the responsibility to consult the appropriate authorities and to establish appropriate health and safety practices in conjunction with any applicable regulatory requirements prior to its use.2. REFERENCED PUBLICATIONS2.1 The following publications are referenced in this method:2.1.1 ASTM I
31、nternationalD4057 Standard Practice for Manual Sampling of Petroleum and Petroleum ProductsD6299 Standard Practice for Applying Statistical Quality Assurance Techniques to Evaluate Analytical Measurement System PerformanceE969 Standard Specification for Glass Volumetric (Transfer) Pipets.2.2 A dated
32、 reference in this method is to the issue specified. An undated reference in this method is to the latest issue, unless otherwise specified by the authority applying this method. The sources are given in the Notes section.3. SUMMARY OF TEST METHOD3.1 The gasoline sample is diluted with methyl isobut
33、yl ketone, the lead alkyl compounds are stabilized by a reaction with iodine, and the resultant lead alkyl iodide is complexed with a quaternary ammonium salt. The lead content of the sample is determined by atomic absorption spectrophotometry at 283.3 nm. Standards prepared from reagent-grade lead
34、chloride are used for calibration. The method compensates for variations in gasoline composition and is independent of the lead alkyl type.4. SIGNIFICANCE AND USE4.1 This method is used to ensure compliance of automotive gasolines with product or regulatory standards.5. APPARATUSNote: It is good lab
35、oratory practice to segregate apparatus that will be reused, such as sample bottles, volumetric flasks and pipettes, into two sets. Reserve one set for leaded gasoline and another set for unleaded gasoline.Copyright Canadian General Standards Board Provided by IHS under license with CGSBNot for Resa
36、leNo reproduction or networking permitted without license from IHS-,-,-2 No. 19.520115.1 Spectrophotometer: atomic absorption, capable of scale expansion and nebulizer adjustment and equipped with a slot burner and premix chamber for use with an air-acetylene flame.5.2 Pipettes: glass, with capaciti
37、es of 0.5, 1, 2, 3, 4, and 5 mL, “to deliver” and Class A volume accuracy in accordance with ASTM E969.5.3 Volumetric flasks: borosilicate with ground-glass stoppers, with capacities of 25, 50, 100, 250 and 1000 mL.5.4 Micropipette: Eppendorf type or equivalent, 100 L capacity.5.5 Sample bottles: br
38、own glass with polyethylene or polytetrafluoroethylene-lined (PTFE-lined) caps, or amber polypropylene bottles and caps, with nominal capacities of 50, 100, 250 and 1000 mL.6. REAGENTSReagent-grade chemicals are required for this method.6.1 Methyl isobutyl ketone (MIBK): certified lead free 4-methyl
39、-2-pentanone.6.2 Iodine solution: dissolve 3.0 g of iodine crystals in toluene and dilute to 100 mL.6.3 Aliquot 336 (tricaprylmethylammonium chloride).6.4 Aliquot 336/MIBK solution (10% v/v): dissolve 100 mL (88.0 g) of Aliquot 336 in MIBK and dilute to 1 L.6.5 Aliquot 336/MIBK solution (1% v/v): di
40、ssolve 10 mL (8.8 g) of Aliquot 336 in MIBK and dilute to 1 L.6.6 Lead chloride: (PbCl2).6.7 Isooctane (2,2,4trimethylpentane): certified lead free.6.8 Air: compressed.6.9 Acetylene: compressed.6.10 Stock lead solution (1000 mg lead/L): dissolve 0.3356 g of lead chloride previously dried at 105oC fo
41、r 3 h, in approximately 200 mL of 10% Aliquot 336/MIBK solution in a 250 mL volumetric flask. Dilute to the mark with the 10% Aliquot 336/MIBK solution, mix and store in a sample bottle. The most serious potential source of error in this method lies in the preparation of this solution. Therefore, th
42、e utmost care is required in its preparation and handling.6.11 Working standard lead solutions (5, 10, 20, 30, 40 and 50 mg lead/L): transfer 0.5, 1, 2, 3, 4 and 5 mL of the 1000 mg lead/L solution by pipette to 100 mL volumetric flasks and dilute to the mark with MIBK. Mix well and store in sample
43、bottles. These solutions should be prepared and used within one day.7. SAFETY PRECAUTIONS7.1 Gasolines are flammable and explosive. All appropriate safety precautions should be observed.8. PROCEDURE8.1 Sampling Sampling is to be carried out in accordance with ASTM D4057 in recognition that test resu
44、lts are dependent upon the integrity of the samples provided. Samples that must be stored for more than one day should be refrigerated between 0 and 4C to minimize losses. Allow the samples to warm to room temperature just prior to analysis.Copyright Canadian General Standards Board Provided by IHS
45、under license with CGSBNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-No. 19.52011 38.2 Analysis8.2.1 Optimize the atomic absorption spectrophotometer for lead at 283.3 nm. Light the air-acetylene flame. Using the reagent blank (par. 9.1.5) adjust the gas mixture
46、and the sample aspiration rate to obtain an oxidizing flame. MIBK solutions should be aspirated at about one-third the rate of aqueous solutions so that the flame remains blue.8.2.2 In order to achieve the lower detection limits of this method, optimization of the atomic absorption operating paramet
47、ers and equipment is recommended. The absorbance of the 30 mg/L calibration standard should be optimized to its maximum value, which is typically greater than 0.15.8.2.3 Dilute the gasoline sample, if necessary, in accordance with Table 1. Samples with a lead concentration exceeding 50 mg/L must fir
48、st be diluted with isooctane to bring the lead concentrations below this level. Table 1 shows the necessary dilutions for concentrations up to 1000 mg/L. Dilutions have been chosen so that the concentration to be measured lies in the middle to upper range for the method.8.2.4 Pipette 5 mL of the gas
49、oline sample into a 50 mL volumetric flask containing approximately 30 mL of MIBK and mix.8.2.5 Add 100 L of iodine solution using the micropipette, mix well and allow the mixture to react for one minute.8.2.6 Add 5 mL of 1% Aliquot 336/MIBK solution using a pipette, mix well and dilute to volume with MIBK. Mix again. Allow the sample to stabilize for five minutes.8.2.7 Aspir