1、B366.1-11Solid-fuel-fired central heating appliancesLegal Notice for StandardsCanadian Standards Association (CSA) standards are developed through a consensus standards development process approved by the Standards Council of Canada. This process brings together volunteers representing varied viewpo

2、ints and interests to achieve consensus and develop a standard. Although CSA administers the process and establishes rules to promote fairness in achieving consensus, it does not independently test, evaluate, or verify the content of standards.Disclaimer and exclusion of liabilityThis document is pr

3、ovided without any representations, warranties, or conditions of any kind, express or implied, including, without limitation, implied warranties or conditions concerning this documents fitness for a particular purpose or use, its merchantability, or its non-infringement of any third partys intellect

4、ual property rights. CSA does not warrant the accuracy, completeness, or currency of any of the information published in this document. CSA makes no representations or warranties regarding this documents compliance with any applicable statute, rule, or regulation. IN NO EVENT SHALL CSA, ITS VOLUNTEE

5、RS, MEMBERS, SUBSIDIARIES, OR AFFILIATED COMPANIES, OR THEIR EMPLOYEES, DIRECTORS, OR OFFICERS, BE LIABLE FOR ANY DIRECT, INDIRECT, OR INCIDENTAL DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES, HOWSOEVER CAUSED, INCLUDING BUT NOT LIMITED TO SPECIAL OR CONSEQUENTIAL DAMAGES, LOST REVENUE, BUSINESS INTERRU

6、PTION, LOST OR DAMAGED DATA, OR ANY OTHER COMMERCIAL OR ECONOMIC LOSS, WHETHER BASED IN CONTRACT, TORT (INCLUDING NEGLIGENCE), OR ANY OTHER THEORY OF LIABILITY, ARISING OUT OF OR RESULTING FROM ACCESS TO OR POSSESSION OR USE OF THIS DOCUMENT, EVEN IF CSA HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH D

7、AMAGES, INJURY, LOSS, COSTS, OR EXPENSES.In publishing and making this document available, CSA is not undertaking to render professional or other services for or on behalf of any person or entity or to perform any duty owed by any person or entity to another person or entity. The information in this

8、 document is directed to those who have the appropriate degree of experience to use and apply its contents, and CSA accepts no responsibility whatsoever arising in any way from any and all use of or reliance on the information contained in this document. CSA is a private not-for-profit company that

9、publishes voluntary standards and related documents. CSA has no power, nor does it undertake, to enforce compliance with the contents of the standards or other documents it publishes. Intellectual property rights and ownershipAs between CSA and the users of this document (whether it be in printed or

10、 electronic form), CSA is the owner, or the authorized licensee, of all works contained herein that are protected by copyright, all trade-marks (except as otherwise noted to the contrary), and all inventions and trade secrets that may be contained in this document, whether or not such inventions and

11、 trade secrets are protected by patents and applications for patents. Without limitation, the unauthorized use, modification, copying, or disclosure of this document may violate laws that protect CSAs and/or others intellectual property and may give rise to a right in CSA and/or others to seek legal

12、 redress for such use, modification, copying, or disclosure. To the extent permitted by licence or by law, CSA reserves all intellectual property rights in this document.Patent rightsAttention is drawn to the possibility that some of the elements of this standard may be the subject of patent rights.

13、 CSA shall not be held responsible for identifying any or all such patent rights. Users of this standard are expressly advised that determination of the validity of any such patent rights is entirely their own responsibility.Authorized use of this documentThis document is being provided by CSA for i

14、nformational and non-commercial use only. The user of this document is authorized to do only the following:If this document is in electronic form:.load this document onto a computer for the sole purpose of reviewing it;.search and browse this document; and.print this document if it is in PDF format.

15、 Limited copies of this document in print or paper form may be distributed only to persons who are authorized by CSA to have such copies, and only if this Legal Notice appears on each such copy.In addition, users may not and may not permit others to.alter this document in any way or remove this Lega

16、l Notice from the attached standard;.sell this document without authorization from CSA; or.make an electronic copy of this document.If you do not agree with any of the terms and conditions contained in this Legal Notice, you may not load or use this document or make any copies of the contents hereof

17、, and if you do make such copies, you are required to destroy them immediately. Use of this document constitutes your acceptance of the terms and conditions of this Legal Notice.Update No. 1B366.1-11January 2014Note: For information about the Standards Update Service, go to shop.csa.ca or e-mail tec

18、hsupportcsagroup.org.Title: Solid-fuel-fired central heating appliances originally published January 2011The following revisions have been formally approved and are marked by the symbol delta () in the margin on the attached replacement pages:Revised Clause 1.1New NoneDeleted None Update your copy b

19、y inserting these revised pages.Keep the pages you remove for reference. 2014 CSA Group Solid-fuel-fired central heating appliancesJanuary 2014B366.1-11Solid-fuel-fired central heating appliances1 Scope1.1 This Standard applies to manually or automatically fuelled solid-fuel-fired central heating ap

20、pliances that have provision for venting directly to the outdoors by means of flue pipes, chimneys, etc.1.2 For the purposes of this Standard, the term “solid fuel” includes, but is not limited to, coal and biomass fuels such as cordwood, chips, sawdust, wood and paper pellets, and corn.1.3 This Sta

21、ndard applies to factory- or field-assembled appliances that have been or could have been completely assembled at the manufacturers plant and transported in the assembled condition.1.4 This Standard also applies to the manually or automatically fuelled solid-fuel features of a combination solid-fuel

22、-/fuel-oil-fired appliance, where the solid-fuel features can affect the safety or performance of the oil-fired appliance. In these cases, the requirements specified in this Standard are additional to the requirements that apply to the oil-fired appliance.1.5 This Standard also applies to outdoor-ai

23、red solid-fuel-fired appliances.1.6 This Standard also applies to solid-fuel-fired furnaces intended to be added on directly in series at a point after the warm air leaves the forced warm air oil-, natural-gas-, or propane-fired furnace (downstream series add-on).1.7 The requirements specified in th

24、is Standard for solid-fuel-fired add-on furnaces also apply to any additional ductwork, controls, and other equipment recommended by the add-on furnace manufacturer and intended to be added on during the installation of the furnace.1.8 The requirements specified in this Standard for solid-fuel-fired

25、 add-on furnaces do not apply to parallel systems and upstream series add-ons (where the solid-fuel-fired furnace has been added on directly in series at a point before the air enters the existing forced warm air furnace).1.9 This Standard also applies to solid-fuel-fired furnaces(a) intended to be

26、added on directly in series at a point after the warm air leaves the existing forced warm air electric furnace (downstream series add-on); and(b) with a single warm air discharge meeting the requirements of CSA C22.2 No. 23.1.1(Replaces p. 1, January 2011)B366.1-11 2014 CSA GroupJanuary 20141.10 Thi

27、s Standard does not cover fireplaces, incinerators, space heaters, or stoves.1.11 In CSA standards, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advi

28、sed but not required; and “may” is used to express an option or that which is permissible within the limits of the standard.Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or info

29、rmative material.Notes to tables and figures are considered part of the table or figure and may be written as requirements.Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.1.12 The values given in SI units are the units of record for the purposes

30、 of this Standard. The values given in parentheses are for information and comparison only.2 Reference publicationsThis Standard refers to the following publications, and where such reference is made, it shall be to the edition listed below, including all amendments published thereto.Note: See also

31、Annex C.CSA (Canadian Standards Association)B51-09Boiler, pressure vessel, and pressure piping codeB139-09Installation code for oil-burning equipmentB140 series of StandardsB140.0-03 (R2008)Oil-burning equipment: General requirementsB140.2.1-10Atomizing-type oil burnersB140.3-1962 (R2006)Oil burning

32、 stoves and water heatersCAN/CSA-B140.4-04 (R2009)Oil-fired warm-air furnacesB140.7-05 (R2010)Oil-burning equipment: Steam and hot-water boilersB140.10-06Oil-fired warm-air heating appliances for mobile housing and recreational vehicles(Replaces p. 2, January 2011)2CSA Standards Update ServiceB366.1

33、-11January 2011Title:Solid-fuel-fired central heating appliancesPagination:83 pages (x preliminary and 73 text), each dated January 2011To register for e-mail notification about any updates to this publicationgo to www.ShopCSA.caclick on E-mail Services under MY ACCOUNTclick on CSA Standards Update

34、ServiceThe List ID that you will need to register for updates to this publication is 2421011.If you require assistance, please e-mail techsupportcsa.ca or call 416-747-2233.Visit CSAs policy on privacy at www.csagroup.org/legal to find out how we protect your personal information.Published in Januar

35、y 2011 by Canadian Standards AssociationA not-for-profit private sector organization5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5N61-800-463-6727 416-747-4044Visit our Online Store at www.ShopCSA.caB366.1-11Solid-fuel-fired central heating appliancesCSA Standard100%ISBN 978-1-5549

36、1-480-7 Canadian Standards Association 2011All rights reserved. No part of this publication may be reproduced in any form whatsoever without the prior permission of the publisher.To purchase CSA Standards and related publications, visit CSAs Online Store at www.ShopCSA.ca or call toll-free 1-800-463

37、-6727 or 416-747-4044.The Canadian Standards Association (CSA) prints its publications on Rolland Enviro100, which contains 100%recycled post-consumer fibre, is EcoLogo and Processed Chlorine Free certified, and was manufactured using biogas energy.January 2011 iiiContents Canadian Standards Associa

38、tion Solid-fuel-fired central heating appliancesTechnical Committee on Installation Code for Solid-Fuel-Burning Appliances viiSubcommittee on Solid-Fuel-Fired Central Heating Appliances ixPreface x1Scope12 Reference publications 23 Definitions 44 General requirements 44.1 Materials, quality of work,

39、 and construction 44.2 Electrical features 44.3 Barometric draft controls 45 Construction 55.1 Mechanical 55.2 Venting 55.3 Fuelling and ash removal 65.4 Firebox grates or liners 75.5 Stability 76 Controls 76.1 General 76.2 Combustion air 86.3 Safety limit controls and auxiliary temperature limit co

40、ntrols 86.3.1 General 86.3.2 Safety limit control 86.3.3 Optional auxiliary temperature limit control 96.3.4 Auxiliary temperature limit control system 97 Requirements for specific appliances 97.1 Solid-fuel-fired furnaces 97.2 Solid-fuel-fired boilers 107.3 Automatic fuel-feeding devices 117.4 Soli

41、d-fuel-fired outdoor-aired appliances 138Markings138.1 General 138.2 Basic data 138.3 Operating instructions 148.4 Installation instructions 149 Instructions 1510 Solid-fuel-firing tests 1610.1 Test installation 1610.2 Test fuel Conventional firewood 1710.3 Test fuel Particulate biomass 18B366.1-11

42、Canadian Standards Associationiv January 201110.4 Test fuel Coal 1810.5 Starting the fire 1810.6 Maintaining the fire 1810.7 Test sequence 1810.8 Reverse flow test (warm air furnaces) 1910.9 Combustion test 1910.10 Minimum heat exchanger temperature test (warm air furnaces) 2010.11 Limit test, norma

43、l temperature test, interrupted electrical power test, and abnormal electrical power test 2010.11.1 Limit test 2010.11.2 Normal temperature test 2110.11.3 Interrupted electrical power test 2110.11.4 Abnormal electrical power test 2110.12 Extended electrical power failure operation test 2110.13 Flash

44、 fire test 2210.14 Relieving valve test (boilers) 2210.15 Heat exchanger burnout test (warm air furnaces) 2210.16 Strength test 2310.17 Stability test 2310.18 Outdoor-aired appliance tests 2310.19 Automatic fuel-feeding device tests 2311 Additional requirements for combination solid-fuel-/ oil-fired

45、 appliances 2411.1 General 2411.2 Temperature tests 2411.3 Ignition and combustion safety control response tests 2512 Additional requirements for solid-fuel-fired add-ons to oil-fired furnaces 2512.1 General 2512.2 Construction 2612.3 Additional markings 2612.4 Instructions 2712.5 Tests 2812.5.1 Pre

46、ssure loss test 2812.5.2 Firing test 2813 Additional requirements for solid-fuel-fired add-ons to electric furnaces 2813.1 General 2813.2 Construction 2913.3 Additional markings 3013.4 Instructions 3013.5 Tests 3113.5.1 General 3113.5.2 Pressure loss test 3113.5.3 Firing test 3214 Additional require

47、ments for solid-fuel-fired add-ons to gas-fired furnaces 3214.1 General 3214.2 Construction 3214.3 Additional markings 3314.4 Instructions 3414.5 Tests 3514.5.1 Pressure loss test 3514.5.2 Firing test 35 Canadian Standards Association Solid-fuel-fired central heating appliancesJanuary 2011 v15 Addit

48、ional requirements for outdoor central heating appliances 3515.1 General 3515.2 Enclosures 3515.2.1 General 3515.2.2 Corrosion protection 3615.3 Field wiring connections 3815.4 Internal wiring 3815.5 Electrical insulating material 3815.6 Rain test 3815.7 Accelerated aging test Gaskets, adhesives, an

49、d sealing compounds 3915.8 Metallic coating thickness test 4015.9 Markings 4116 Catalytic combustors 4116.1 General 4116.2 Location and mounting 4116.3 Additional markings 4216.4 Additional instructions 4216.5 Combustion, spillage, and normal temperature tests 4216.6 Replacement combustor kit 42AnnexesA(informative) Standard nozzle sizes 67B(informative) Translations of markings 68C(informative) Bibliography 73Tables1 Coal composition 432 Wood chip and wood pellet grades 443 Maximum allowable total or gross temperatures for general construction m

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1