1、C22.2 No. 178.2-04(reaffirmed 2014)Requirements for manually operated generator transfer panelsLegal Notice for StandardsCanadian Standards Association (CSA) standards are developed through a consensus standards development process approved by the Standards Council of Canada. This process brings tog

2、ether volunteers representing varied viewpoints and interests to achieve consensus and develop a standard. Although CSA administers the process and establishes rules to promote fairness in achieving consensus, it does not independently test, evaluate, or verify the content of standards.Disclaimer an

3、d exclusion of liabilityThis document is provided without any representations, warranties, or conditions of any kind, express or implied, including, without limitation, implied warranties or conditions concerning this documents fitness for a particular purpose or use, its merchantability, or its non

4、-infringement of any third partys intellectual property rights. CSA does not warrant the accuracy, completeness, or currency of any of the information published in this document. CSA makes no representations or warranties regarding this documents compliance with any applicable statute, rule, or regu

5、lation. IN NO EVENT SHALL CSA, ITS VOLUNTEERS, MEMBERS, SUBSIDIARIES, OR AFFILIATED COMPANIES, OR THEIR EMPLOYEES, DIRECTORS, OR OFFICERS, BE LIABLE FOR ANY DIRECT, INDIRECT, OR INCIDENTAL DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES, HOWSOEVER CAUSED, INCLUDING BUT NOT LIMITED TO SPECIAL OR CONSEQUENT

6、IAL DAMAGES, LOST REVENUE, BUSINESS INTERRUPTION, LOST OR DAMAGED DATA, OR ANY OTHER COMMERCIAL OR ECONOMIC LOSS, WHETHER BASED IN CONTRACT, TORT (INCLUDING NEGLIGENCE), OR ANY OTHER THEORY OF LIABILITY, ARISING OUT OF OR RESULTING FROM ACCESS TO OR POSSESSION OR USE OF THIS DOCUMENT, EVEN IF CSA HA

7、S BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES.In publishing and making this document available, CSA is not undertaking to render professional or other services for or on behalf of any person or entity or to perform any duty owed by any person or entity to anothe

8、r person or entity. The information in this document is directed to those who have the appropriate degree of experience to use and apply its contents, and CSA accepts no responsibility whatsoever arising in any way from any and all use of or reliance on the information contained in this document. CS

9、A is a private not-for-profit company that publishes voluntary standards and related documents. CSA has no power, nor does it undertake, to enforce compliance with the contents of the standards or other documents it publishes. Intellectual property rights and ownershipAs between CSA and the users of

10、 this document (whether it be in printed or electronic form), CSA is the owner of all works contained herein that are protected by copyright, all trade-marks (except as otherwise noted to the contrary), and all inventions and trade secrets that may be contained in this document, whether or not such

11、inventions and trade secrets are protected by patents and applications for patents. The unauthorized use, modification, copying, or disclosure of this document may violate laws that protect CSAs intellectual property and may give rise to a right in CSA to seek legal redress for such use, modificatio

12、n, copying, or disclosure. CSA reserves all intellectual property rights in this document.Authorized use of this documentThis document is being provided by CSA for informational and non-commercial use only. The user of this document is authorized to do only the following:If this document is in elect

13、ronic form:.load this document onto a computer for the sole purpose of reviewing it;.search and browse this document; and.print this document. Limited copies of this document in print or paper form may be distributed only to persons who are authorized by CSA to have such copies, and only if this Leg

14、al Notice appears on each such copy.In addition, users may not and may not permit others to.alter this document in any way or remove this Legal Notice from the attached standard;.sell this document without authorization from CSA; or.make an electronic copy of this document.If you do not agree with a

15、ny of the terms and conditions contained in this Legal Notice, you may not load or use this document or make any copies of the contents hereof, and if you do make such copies, you are required to destroy them immediately. Use of this document constitutes your acceptance of the terms and conditions o

16、f this Legal Notice.Standards Update ServiceC22.2 No. 178.2-04January 2004Title: Requirements for manually operated generator transfer panelsPagination: 27 pages (viii preliminary and 19 text), each dated January 2004To register for e-mail notification about any updates to this publicationgo to shop

17、.csa.caclick on CSA Update ServiceThe List ID that you will need to register for updates to this publication is 2015604.If you require assistance, please e-mail techsupportcsagroup.org or call 416-747-2233.Visit CSA Groups policy on privacy at csagroup.org/legal to find out how we protect your perso

18、nal information.Blank pageCSA Standards Update ServiceC22.2 No. 178.2-04January 2004Title: Requirements for manually operated generator transfer panelsPagination: 27 pages (viii preliminary and 19 text), each dated January 2004Automatic notifications about any updates to this publication are availab

19、le.To register for e-mail notifications, and/or to download any existing updates in PDF, enter the Online Store at www.csa.ca and click on My Account on the navigation bar.The List ID for this document is 2015604.To receive printed updates, please complete and return the attached card.NameOrganizati

20、onAddressCityProvince/StateCountry Postal/Zip CodeE-mailI consent to CSA collecting and using the above information to send me updates relating to this publication.Visit CSAs policy on privacy at www.csagroup.org/legal to find out how we protect your personal information.C22.2 No. 178.2-04Affranchir

21、suffisammentPlaceStamp HereASSOCIATION CANADIENNE DENORMALISATIONBUREAU CENTRAL DE LINFORMATION5060, SPECTRUM WAY, BUREAU 100MISSISSAUGA ON L4W 5N6CANADACANADIAN STANDARDSASSOCIATIONCONSOLIDATED MAILING LIST5060 SPECTRUM WAY, SUITE 100MISSISSAUGA ON L4W 5N6CANADAPublished in January 2004 by Canadian

22、 Standards AssociationA not-for-profit private sector organization5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5N61-800-463-6727 416-747-4044Visit our Online Store at www.csa.caCSA StandardC22.2 No. 178.2-04Requirements for manually operated generator transfer panelsISBN 1-55397-55

23、1-0Technical Editor: Tim Pope Canadian Standards Association 2004All rights reserved. No part of this publication may be reproduced in any form whatsoever without the prior permission of the publisher. Canadian Standards Association Requirements for manually operated generator transfer panelsJanuary

24、 2004 iiiContentsTechnical Committee on Industrial Products vSubcommittee on C22.2 No. 178 viPreface viiForeword viii1Scope 12 Reference publications 13 Definitions 24 General requirements 35 Construction 35.1 General 35.2 Enclosures 35.3 Mounting bases for live parts 35.4 Mounting of parts 35.5 Cur

25、rent-carrying parts 45.6 Wiring 45.7 Wiring space and wire-bending space 45.8 Electrical spacings 55.9 Operating mechanism 65.10 Bonding and grounding 65.11 Neutral connections 65.12 Ratings 75.13 Switching means 75.13.1 Circuit breakers and moulded-case switches 75.13.2 Special use (snap) switches

26、75.13.3 Other switches 85.13.4 Use of supplementary protectors 86Marking 87 Tests 107.1 General 107.2 Overload 117.3 Temperature 117.4 Endurance 127.5 Dielectric withstand 127.6 Short-circuit withstand 127.7 Closing 137.8 Instrumentation and calibration of high-capacity circuits 147.9 Dielectric wit

27、hstand (repeated) 147.10 Supplementary protector short-circuit compatibility 14C22.2 No. 178.2-04 Canadian Standards Associationiv January 2004AnnexesA Markings French translations 19Tables1 Minimum spacing for live parts 152 Dimensionsofbushings 153 Size of bonding conductors 164 Short-circuit curr

28、ent requirement 165 Voltage for tests 166 Maximum acceptable temperature rises 177 Endurance test cycles 18 Canadian Standards Association Requirements for manually operated generator transfer panelsJanuary 2004 vTechnical Committee on Industrial ProductsK. Powell Criterions,Glen Williams, OntarioCh

29、airT. Pope CSA,Mississauga, OntarioProject ManagerRepresenting Regulatory AuthoritiesT. Olechna Electrical Safety Authority,Mississauga, OntarioS. Paulsen Province of New Brunswick,Fredericton, New BrunswickJ.-L. Robert Rgie du btiment du Qubec,Qubec, QubecA. Tsisserev City of Vancouver,Vancouver, B

30、ritish Columbia,Representing ManufacturersR. Bartholomew Electric Power Equipment,Vancouver, British ColumbiaK. Jones Cutler-Hammer Canada,Milton, OntarioM. Smith Rockwell Automation,Cambridge, OntarioRepresenting General InterestsM. Kasumovich Mississauga, OntarioConsumer RepresentativeR. Roberton

31、Shell Canada,Calgary, AlbertaC22.2 No. 178.2-04 Canadian Standards Associationvi January 2004Subcommittee on C22.2 No. 178B. Buckler Ascoelectric Limited,Brantford, OntarioChairA. Bapat Schneider Canada Inc.,Toronto, OntarioK. Brightwell Ontario Electrical Safety Authority,Mississauga, OntarioA. Kun

32、ert TornaTech Inc.,Saint-Laurent, QubecR. MacKenzie CSA International,Toronto, OntarioM. Milev Cutler-Hammer Canada,Burlington, OntarioB. Savaria Cutler-Hammer Canada,Burlington, OntarioN. Schmidt Thomson Technology Inc.,Surrey, British ColumbiaS. Singh Schneider Canada Inc.,Toronto, OntarioM. Smith

33、 Rockwell Automation,Cambridge, OntarioA. Tsisserev City of Vancouver,Vancouver, British ColumbiaT. Pope CSA,Mississauga, OntarioProject ManagerIn addition to the members of the subcommittee, the following people also contributed to the development and publication of this Standard: J. de Vaal Thomso

34、n Technology Inc.,Surrey, British ColumbiaD. Pybus Ascoelectric Limited,Brantford, Ontario Canadian Standards Association Requirements for manually operated generator transfer panelsJanuary 2004 viiPrefaceThis is the first edition of CSA C22.2 No. 178.2, Requirements for manually operated generator

35、transfer panels, one of a series of Standards issued under Part II of the Canadian Electrical Code. This Standard incorporates the requirements of CSA Internationals Technical Information Letter No. M-03.Once published, provisions for automatic transfer switches and high voltage transfer switches wi

36、ll be covered in CSA C22.2 No. 178.1 and C22.2 No. 178.3, respectively.For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of CAN/CSA-C22.2 No. 0, General Requirements Canadian Electrical Code, Part II.This Standard was prepared by the Subcommittee on C

37、22.2 No. 178, under the jurisdiction of the Technical Committee on Industrial Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee.Interpretations: The Strategic Steering Committee on Requirements for Electrica

38、l Safety has provided the following direction for the interpretation of standards under its jurisdiction. “The literal text shall be used in judging compliance of products with the safety requirements of this Standard. When the literal text cannot be applied to the product, such as for new materials

39、 or construction, and when a relevant committee interpretation has not already been published, CSAs procedures for interpretation shall be followed to determine the intended safety principle”.January 2004Notes: (1) Use of the singular does not exclude the plural (and vice versa) when the sense allow

40、s.(2) Although the intended primary application of this Standard is stated in its Scope, it is important to note that it remains the responsibility of the users of the Standard to judge its suitability for their particular purpose.(3) This publication was developed by consensus, which is defined by

41、CSA Policy governing standardization Code of good practice for standardization as “substantial agreement. Consensus implies much more than a simple majority, but not necessarily unanimity”. It is consistent with this definition that a member may be included in the Technical Committee list and yet no

42、t be in full agreement with all clauses of this publication.(4) CSA Standards are subject to periodic review, and suggestions for their improvement will be referred to the appropriate committee.(5) All enquiries regarding this Standard, including requests for interpretation, should be addressed to C

43、anadian Standards Association, 5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5N6.Requests for interpretation should(a) define the problem, making reference to the specific clause, and, where appropriate, include an illustrative sketch;(b) provide an explanation of circumstances surr

44、ounding the actual field condition; and(c) be phrased where possible to permit a specific “yes” or “no” answer.Committee interpretations are processed in accordance with the CSA Directives and guidelines governingstandardization and are published in CSAs periodical Info Update, which is available on

45、 the CSA Web site atwww.csa.ca.C22.2 No. 178.2-04 Canadian Standards Associationviii January 2004ForewordThe Canadian Standards Association (CSA) develops standards under the name Canadian Standards Association, and provides certification and testing under the name CSA International. CSA Internation

46、al provides certification services for manufacturers who, under license from CSA, wish to use the appropriate registered CSA Marks on certain products of their manufacture to indicate conformity with CSA Standards.CSA Certification for a number of products is provided in the interest of maintaining

47、agreed-upon standards of quality, performance, interchangeability and/or safety, as appropriate. Where applicable, certification may form the basis for acceptance by inspection authorities responsible for enforcement of regulations. Where feasible, programs will be developed for additional products

48、for which certification is desired by producers, consumers, or other interests. In performing its functions in accordance with its objectives, CSA does not assume or undertake to discharge any responsibility of the manufacturer or any other party. The opinions and findings of the Association represe

49、nt its professional judgement given with due consideration to the necessary limitations of practical operation and state of the art at the time the Standard is processed.Products in substantial accord with this Standard but which exhibit a minor difference or a new feature may be deemed to meet the Standard providing the feature or difference is found acceptable utilizing appropriate CSA International Operating Procedures. Products that comply with this Standard shall not be certified if they are found to have additional features which are in

展开阅读全文
相关资源
猜你喜欢
  • BS EN 60749-6-2002 Semiconductor devices - Mechanical and climatic test methods - Storage at high temperature《半导体器件 机械和气候试验方法 高温下储存》.pdf BS EN 60749-6-2002 Semiconductor devices - Mechanical and climatic test methods - Storage at high temperature《半导体器件 机械和气候试验方法 高温下储存》.pdf
  • BS EN 60749-7-2011 Semiconductor devices Mechanical and climatic test methods Internal moisture content measurement and the analysis of other residual gases《半导体装置 机械和气候耐受性试验方法 其他残余.pdf BS EN 60749-7-2011 Semiconductor devices Mechanical and climatic test methods Internal moisture content measurement and the analysis of other residual gases《半导体装置 机械和气候耐受性试验方法 其他残余.pdf
  • BS EN 60749-8-2003 Semiconductor devices Mechanical and climatic test methods Sealing《半导体器件 机械和气候试验方法 密封》.pdf BS EN 60749-8-2003 Semiconductor devices Mechanical and climatic test methods Sealing《半导体器件 机械和气候试验方法 密封》.pdf
  • BS EN 60749-9-2002 Semiconductor devices - Mechanical and climatic test methods - Permanence of marking《半导体器件 机械和气候试验方法 永久性标记》.pdf BS EN 60749-9-2002 Semiconductor devices - Mechanical and climatic test methods - Permanence of marking《半导体器件 机械和气候试验方法 永久性标记》.pdf
  • BS EN 60751-2008 Industrial platinum resistance thermometers and platinum temperature sensors《工业铂电阻温度计和铂温度传感器》.pdf BS EN 60751-2008 Industrial platinum resistance thermometers and platinum temperature sensors《工业铂电阻温度计和铂温度传感器》.pdf
  • BS EN 60754-1-2014 Test on gases evolved during combustion of materials from cables Determination of the halogen acid gas content《取自电缆的材料燃烧时释出气体的试验 卤酸气体含量的测定》.pdf BS EN 60754-1-2014 Test on gases evolved during combustion of materials from cables Determination of the halogen acid gas content《取自电缆的材料燃烧时释出气体的试验 卤酸气体含量的测定》.pdf
  • BS EN 60754-2-2014 Test on gases evolved during combustion of materials from cables Determination of acidity (by pH measurement) and conductivity《取自电缆的材料燃烧时释出气体的试验 酸度(通过pH测量)和电导率的测.pdf BS EN 60754-2-2014 Test on gases evolved during combustion of materials from cables Determination of acidity (by pH measurement) and conductivity《取自电缆的材料燃烧时释出气体的试验 酸度(通过pH测量)和电导率的测.pdf
  • BS EN 60756-1991 Non-broadcast video tape recorders - Time base stability《非播放用磁带录像机 时基稳定性》.pdf BS EN 60756-1991 Non-broadcast video tape recorders - Time base stability《非播放用磁带录像机 时基稳定性》.pdf
  • BS EN 60758-2016 Synthetic quartz crystal Specifications and guidelines for use《人造石英晶体 使用规范和指南》.pdf BS EN 60758-2016 Synthetic quartz crystal Specifications and guidelines for use《人造石英晶体 使用规范和指南》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1