1、February 2009DEUTSCHE NORM English price group 10No part of this standard may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 91.190!$UvZ“1508355ww
2、w.din.deDDIN EN 13126-11Building hardware Requirements and test methods for windows and doors heightwindows Part 11: Top hung projecting reversible hardwareEnglish version of DIN EN 13126-11:2009-02Baubeschlge Beschlge fr Fenster und Fenstertren - Anforderungen und Prfverfahren Teil 11: Umkehrbeschl
3、ge fr auskragende Schwing-KlappflgelfensterEnglische Fassung DIN EN 13126-11:2009-02SupersedesDIN CEN/TS 13126-11:2004-08www.beuth.deDocument comprises 14 pagesDIN EN 13126-11:2009-02 2 National foreword This standard has been prepared by Technical Committee CEN/TC 33 “Doors, windows, shutters, buil
4、ding hardware and curtain walling” (Secretariat: AFNOR, France), Working Group WG 4 “Building hardware” (lead-management: BSI, United Kingdom). The responsible German body involved in its preparation was the Normenausschuss Bauwesen (Building and Civil Engineering Standards Committee), Technical Com
5、mittee NA 005-09-53 AA Fensterbeschlge. Amendments a) b) Examples of classification have been added. Previous editions DIN CEN/TS 13126-11: 2004-08 This standard differs from DIN CEN/TS 13126-11:2004-08 as follows: CEN/TS has been editorially revised. EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORME
6、N 13126-11November 2008ICS 91.190 Supersedes CEN/TS 13126-11:2004 English VersionBuilding hardware - Requirements and test methods for windowsand doors height windows - Part 11: Top hung projectingreversible hardwareQuincaillerie pour le btiment - Exigences et mthodesdessai des ferrures de fentres e
7、t portes-fentres - Partie11: Ferrures pour ouvrants litalienne rversibles axehorizontal suprieurBaubeschlge - Beschlge fr Fenster und Fenstertren -Anforderungen und Prfverfahren - Teil 11:Umkehrbeschlge fr auskragende Schwing-KlappflgelfensterThis European Standard was approved by CEN on 5 October 2
8、008.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on
9、 application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Cent
10、re has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland,
11、Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2008 CEN All rights of exploitation in any form and by any mean
12、s reservedworldwide for CEN national Members.Ref. No. EN 13126-11:2008: EEN 13126-11:2008 (E) 2 Contents Page Foreword3 1 Scope.5 2 Normative references 5 3 Terms and definitions5 4 Classification6 4.1 General6 4.2 Category of use (1 first digit) .6 4.3 Durability (2 second digit)6 4.4 Mass (3 third
13、 digit) 6 4.5 Fire resistance (4 fourth digit) .6 4.6 Safety in use (5 fifth digit) 6 4.7 Corrosion resistance (6 sixth digit).6 4.8 Security (7 seventh digit) .6 4.9 Application (8 eighth digit).6 4.10 Test sizes Size limitations (9 ninth digit).6 4.11 Example of classification for top hung project
14、ing reversible hardware7 5 Requirements .7 5.1 General7 5.2 Integrated restrictors.7 5.3 Ease of sash movement test.7 5.4 Durability test .8 5.5 Static load test8 6 Test equipment.8 7 Test methods8 7.1 Samples 8 7.2 Ease of sash movement test procedure9 7.3 Durability test procedure.9 7.4 Static loa
15、d test procedure.10 7.5 Corrosion resistance .10 Annex A (informative) Test method diagrams11 Annex B (normative) Flow chart of test procedure12 DIN EN 13126-11:2009-02 EN 13126-11:2008 (E) 3 Foreword This document (EN 13126-11:2008) has been prepared by Technical Committee CEN/TC 33 “Doors, windows
16、, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2009, and conflicting national standards shall be
17、 withdrawn at the latest by May 2009. This document supersedes CEN/TS 13126-11:2004. This European Standard is one of a series of European Standards dedicated to building hardware products. A full contribution to the preparation of this European Standard has been made by the European manufacturers o
18、rganization “ARGE” and national standards bodies. EN 13126 Building hardware Requirements and test methods for windows and doors height windows consists of the following parts: Part 1: Requirements common to all types of hardware Part 2: Casement fastener handles1)Part 3: Manoeuvring fittings for es
19、pagnolette bolts/sliding button1)Part 4: Espagnolette bolts1)Part 5: Devices that restrict the opening of windows1)Part 6: Variable geometry stay hinges (with or without a friction system) Part 7: Finger catches Part 8: Tilt Digit 2 durability grade 5 (25 000 cycles); Digit 3 mass 60 kg; Digit 4 fir
20、e resistance grade 0 (no requirements); Digit 5 safety in use grade 1; Digit 6 corrosion resistance grade 3; Digit 7 security - (no requirements); Digit 8 applicable part tested in accordance with Part 11 of this standard; Digit 9 test sizes S.R.W.1) = 1 500 mm, S.R.H.2)= 1 500 mm 5 Requirements 5.1
21、 General The requirements for top hung projecting reversible hardware shall be in accordance with Clause 5 of EN 13126-1:2006. 5.2 Integrated restrictors Where top hung projecting reversible hardware is fitted with an integrated restrictor the hardware shall be tested in accordance with CEN/TS 13126
22、-5. 5.3 Ease of sash movement test The test specified in 7.2 shall be used to determine the forces required to operate the hardware is appropriate for the intended use. On completion of the ease of sash movement test in accordance with 7.2. DIN EN 13126-11:2009-02 EN 13126-11:2008 (E) 8 Force requir
23、ed to initiate movement in either the opening or closing direction shall not have exceeded 100 N. Force required to sustain movement in either the opening or closing direction shall not have exceeded 100 N. 5.4 Durability test The test specified in 7.3 shall be used to ensure the hardware is capable
24、 of continued operation after cycling in accordance with grades specified in 7.3, with regard given to normal maintenance. On completion of the durability test in accordance with 7.3. Top hung projecting reversible hardware shall continue to function normally. 5.5 Static load test The test specified
25、 in 7.4 shall be used to ensure the mechanical strength of the hardware is appropriate for its intended use. On completion of the static load test in accordance with 7.4. Top hung projecting reversible hardware shall continue to function normally. Measured clearance gap between sash and frame shall
26、not have increased by more than 3 mm from the measured clearance gap prior to the test commencing. 6 Test equipment The top hung projecting reversible hardware shall be installed in the test specimen for testing as in Clause 6 of EN 13126-1:2006, and in accordance with the manufacturers fixing instr
27、uctions. NOTE The hardware manufacturer should provide test specimens for the testing institute. A drawing of the profile cross-section with relevant information should be enclosed in the test application, which also contains the necessary hardware installation information for the windows. The test
28、shall be conducted on a test rig which corresponds in function and shape to the window for which the hardware was intended. The hardware tested shall conform to the manufacturers recommendation for size and mass of the test specimen. 7 Test methods 7.1 Samples Three samples shall be tested in accord
29、ance with this European Standard. sample A performance tests; sample B corrosion test; sample C retained for reference control. NOTE 1 Sample B should only be necessary if no test report can be supplied by the manufacturer regarding the testing of the hardware component or set in accordance with EN
30、1670. DIN EN 13126-11:2009-02 EN 13126-11:2008 (E) 9 NOTE 2 Sample C should be retained by the test institute for the duration of the validity of the test report. NOTE 3 All window fastening devices should not be engaged when measuring the clearance gap between sash and frame. 7.2 Ease of sash movem
31、ent test procedure All integrated or additional restrictors shall be disabled before any testing commences. With the sash in the fully closed position record the amount of force in Newtons required to initiate movement of the sash. Return the sash to the fully closed position and record the amount o
32、f force in Newtons required to sustain uniform movement of sash to between 200 mm and 300 mm from the closed position. With the sash at an open position of between 200 mm and 300 mm from the closed position record the amount of force in Newtons required to initiate movement of the sash. Return the s
33、ash to an open position of between 200 mm and 300 mm from the closed position and record the amount of force in Newtons required to sustain uniform movement of sash to the closed position. The force shall be applied in the direction that would be used for the conventional opening and closing of the
34、sash. The hardware shall conform to the acceptance criteria of 8.4 of EN 13126-1:2006 and 5.3 of this European Standard. 7.3 Durability test procedure All integrated or additional restrictors shall be disabled before any testing commences. Cycle the window in accordance with one of the following gra
35、des at the rate of 250250+cycles/h. grade 3: 10 000 cycles (+ 1 %) cycles; grade 4: 15 000 cycles (+ 1 %) cycles; grade 5: 25 000 cycles (+ 1 %) cycles. The cycle test of the window is performed by repeating the following stages (see Figure A.1). Stage 1 Cycle the sash from the fully closed position
36、 to an open position of between 25 and 40 for a total of 4 500 + 1 % cycles. Stage 2 Cycle the sash from an open position of up to 25 through the maximum opening position and into a reverse position of a minimum of 155 for a total of 500 + 1 % cycles in accordance with Clause 8 of EN 13126-1:2006. N
37、OTE All moving parts requiring lubrication may be lubricated unless the manufacturer has specified the hardware as maintenance free in accordance with hardware manufacturers instructions. Return the window to the closed position. The hardware shall conform to the acceptance criteria of 8.4 of EN 131
38、26-1:2006 and 5.4 of this European Standard. DIN EN 13126-11:2009-02 EN 13126-11:2008 (E) 10 7.4 Static load test procedure Measure and record the clearance gap between the sash and frame at the bottom of the window. Measurements shall be taken at two points; at each corner of the sash at no more th
39、an 50 mm from each side, and along the opening edge (see Figure A.2). Open the sash to 90 2. Secure the top of the sash in this position preventing further sash movement (see Figure A.3). Apply a vertical downward force of 500 N 250+N in increments of 100 N 250+N at the centre of the bottom of the s
40、ash. Maintain force of 500 N for 60 s 50+s. Return the window to the closed position. Measure and record the clearance gap between the sash and the frame at the bottom of the window. Measurements shall be taken at the same position as used prior to the test commencing. The hardware shall conform to
41、the acceptance criteria of 8.4 of EN 13126-1:2006 and 5.5 of this European Standard. 7.5 Corrosion resistance NOTE 1 A test should only be necessary if no test report can be supplied by the manufacturer in accordance with EN 1670. All corrosion tests shall be on original new samples. For Zinc galvan
42、ized surfaces on iron or steel the specified thickness of 12 (class 3) or 16 (class 4) is not necessary if other surface protection methods are used to conform to the requirements (minimum time to formation of white corrosion products) of ISO 4520:1981. ( = micrometre). Unless a test report can be p
43、rovided by the manufacturer the hardware shall be tested in accordance with EN 1670. NOTE 2 The evaluation of the corrosion resistance is limited to the essential areas (as a rule, the visible surfaces of the installed hardware). The following are exempt from the corrosion resistance evaluation: riv
44、et locations; locations of later processing (for example: cleaved surfaces that result from cropping the hardware components, millings); non surface-treated parts/surfaces, provided they are not in the visible vicinity of the hardware (for example: screw guide-holes made of zinc die-cast); welding j
45、oints and their immediate surroundings. DIN EN 13126-11:2009-02 EN 13126-11:2008 (E) 11 Annex A (informative) Test method diagrams M5 73Figure A.1 Durability test rig 134324 Figure A.2 Durability test rig - plan view 6500 N7Figure A.3 Static load test Key 1 width 2 height 3 specimen 4 measured clear
46、ance 5 dual action motor 6 stop block 7 bottom rail M motor DIN EN 13126-11:2009-02 EN 13126-11:2008 (E) 12 Annex B (normative) Flow chart of test procedure 7.5CorrosionResistance7.2DurabilityTest7.3Ease of SashMovementEase of SashMovementRetain forreferencecontrolSample CSample BStartFinishSample A7.4Static LoadTest7.2DIN EN 13126-11:2009-02