DIN EN 61300-2-44-2014 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-44 Tests - Flexing of the strain relief of fibre .pdf

上传人:explodesoak291 文档编号:677107 上传时间:2018-12-27 格式:PDF 页数:10 大小:209.65KB
下载 相关 举报
DIN EN 61300-2-44-2014 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-44 Tests - Flexing of the strain relief of fibre .pdf_第1页
第1页 / 共10页
DIN EN 61300-2-44-2014 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-44 Tests - Flexing of the strain relief of fibre .pdf_第2页
第2页 / 共10页
DIN EN 61300-2-44-2014 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-44 Tests - Flexing of the strain relief of fibre .pdf_第3页
第3页 / 共10页
DIN EN 61300-2-44-2014 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-44 Tests - Flexing of the strain relief of fibre .pdf_第4页
第4页 / 共10页
DIN EN 61300-2-44-2014 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-44 Tests - Flexing of the strain relief of fibre .pdf_第5页
第5页 / 共10页
点击查看更多>>
资源描述

1、Februar 2014DEUTSCHE NORM DKE Deutsche Kommission Elektrotechnik Elektronik Informationstechnik im DIN und VDEPreisgruppe 9DIN Deutsches Institut fr Normung e. V. Jede Art der Vervielfltigung, auch auszugsweise, nur mit Genehmigung des DIN Deutsches Institut fr Normung e. V., Berlin, gestattet.ICS 3

2、3.180.20!%*=“2075726www.din.deDDIN EN 61300-2-44Lichtwellenleiter - Verbindungselemente und passive Bauteile Grundlegende Prf und Messverfahren Teil 2-44: Prfungen Biegen der Zugentlastung vonLichtwellenleiterbauteilen (IEC61300-2-44:2013);Deutsche Fassung EN 61300-2-44:2013Fibre optic interconnecti

3、ng devices and passive components Basic test and measurement procedures Part 2-44: Tests Flexing of the strain relief of fibre optic devices (IEC 61300-2-44:2013);German version EN 61300-2-44:2013Dispositifs dinterconnexion et composants passifs fibres optiques Procdures fondamentales dessais et de

4、mesures Partie 2-44: Essais Flexion du serre-cble des dispositifs fibres optiques(CEI 61300-2-44:2013);Version allemande EN 61300-2-44:2013Alleinverkauf der Normen durch Beuth Verlag GmbH, 10772 BerlinErsatz frDIN EN 61300-2-44:2009-05www.beuth.deGesamtumfang 10 SeitenDIN EN 61300-2-44:2014-02 2 Anw

5、endungsbeginn Anwendungsbeginn fr die von CENELEC am 2013-08-19 angenommene Europische Norm als DIN-Norm ist 2014-02-01. Fr DIN EN 61300-2-44:2009-05 besteht eine bergangsfrist bis 2014-08-19. Nationales Vorwort Vorausgegangener Norm-Entwurf: E DIN EN 61300-2-44:2012-03. Fr dieses Dokument ist das n

6、ationale Arbeitsgremium UK 412.7 LWL-Verbindungstechnik und passive optische Komponenten“ der DKE Deutsche Kommission Elektrotechnik Elektronik Informationstechnik im DIN und VDE (www.dke.de) zustndig. Die enthaltene IEC-Publikation wurde vom SC 86B Fibre optic interconnecting devices and passive co

7、mponents“ erarbeitet. Das IEC-Komitee hat entschieden, dass der Inhalt dieser Publikation bis zu dem Datum (stability date) unverndert bleiben soll, das auf der IEC-Website unter http:/webstore.iec.ch“ zu dieser Publikation angegeben ist. Zu diesem Zeitpunkt wird entsprechend der Entscheidung des Ko

8、mitees die Publikation besttigt, zurckgezogen, durch eine Folgeausgabe ersetzt oder gendert. Fr den Fall einer undatierten Verweisung im normativen Text (Verweisung auf eine Norm ohne Angabe des Ausgabedatums und ohne Hinweis auf eine Abschnittsnummer, eine Tabelle, ein Bild usw.) bezieht sich die V

9、erweisung auf die jeweils neueste gltige Ausgabe der in Bezug genommenen Norm. Fr den Fall einer datierten Verweisung im normativen Text bezieht sich die Verweisung immer auf die in Bezug genommene Ausgabe der Norm. Der Zusammenhang der zitierten Normen mit den entsprechenden Deutschen Normen ergibt

10、 sich, soweit ein Zusammenhang besteht, grundstzlich ber die Nummer der entsprechenden IEC-Publikation. Beispiel: IEC 60068 ist als EN 60068 als Europische Norm durch CENELEC bernommen und als DIN EN 60068 ins Deutsche Normenwerk aufgenommen. nderungen Gegenber DIN EN 61300-2-44:2009-05 wurden folge

11、nde nderungen vorgenommen: a) berarbeitung von Bild 1. b) nderung der Faserlnge von der Biegestelle bis zum Gewicht. Frhere Ausgaben DIN EN 61300-2-44: 2005-12, 2009-05 EN 61300-2-44 September 2013 EUROPISCHE NORM EUROPEAN STANDARD NORME EUROPENNE ICS 33.180.20 Ersatz fr EN 61300-2-44:2008Deutsche F

12、assung Lichtwellenleiter Verbindungselemente und passive Bauteile Grundlegende Prf und Messverfahren Teil 2-44: Prfungen Biegen der Zugentlastung von Lichtwellenleiterbauteilen (IEC 61300-2-44:2013) Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part

13、 2-44: Tests Flexing of the strain relief of fibre optic devices (IEC 61300-2-44:2013) Dispositifs dinterconnexion et composants passifs fibres optiques Procdures fondamentales dessais et de mesures Partie 2-44: Essais Flexion du serre-cble des dispositifs fibres optiques (CEI 61300-2-44:2013) Diese

14、 Europische Norm wurde von CENELEC am 2013-08-19 angenommen. CENELEC-Mitglieder sind gehalten, die CEN/CENELEC-Geschftsordnung zu erfllen, in der die Bedingungen festgelegt sind, unter denen dieser Europischen Norm ohne jede nderung der Status einer nationalen Norm zu geben ist. Auf dem letzten Stan

15、d befindliche Listen dieser nationalen Normen mit ihren bibliographischen Angaben sind beim CEN-CENELEC Management Centre oder bei jedem CENELEC-Mitglied auf Anfrage erhltlich. Diese Europische Norm besteht in drei offiziellen Fassungen (Deutsch, Englisch, Franzsisch). Eine Fassung in einer anderen

16、Sprache, die von einem CENELEC-Mitglied in eigener Verantwortung durch bersetzung in seine Landessprache gemacht und dem CEN-CENELEC Management Centre mitgeteilt worden ist, hat den gleichen Status wie die offiziellen Fassungen. CENELEC-Mitglieder sind die nationalen elektrotechnischen Komitees von

17、Belgien, Bulgarien, Dnemark, Deutschland, der ehemaligen jugoslawischen Republik Mazedonien, Estland, Finnland, Frankreich, Griechenland, Irland, Island, Italien, Kroatien, Lettland, Litauen, Luxemburg, Malta, den Niederlanden, Norwegen, sterreich, Polen, Portugal, Rumnien, Schweden, der Schweiz, de

18、r Slowakei, Slowenien, Spanien, der Tschechischen Republik, der Trkei, Ungarn, dem Vereinigten Knigreich und Zypern. CENELEC Europisches Komitee fr Elektrotechnische Normung European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Management Centre: Ave

19、nue Marnix 17, B-1000 Brssel 2013 CENELEC Alle Rechte der Verwertung, gleich in welcher Form und in welchem Verfahren, sind weltweit den Mitgliedern von CENELEC vorbehalten. Ref. Nr. EN 61300-2-44:2013 DDIN EN 61300-2-44:2014-02 EN 61300-2-44:2013 Vorwort Der Text des Dokuments 86B/3499/CDV, zuknfti

20、ge 3. Ausgabe der IEC 61300-2-44, erarbeitet vom SC 86B Fibre optic interconnecting devices and passive components“ des IEC/TC 86 Fibre optics“, wurde zur parallelen IEC-CENELEC-Abstimmung vorgelegt und von CENELEC als EN 61300-2-44:2013 angenommen. Nachstehende Daten wurden festgelegt: sptestes Dat

21、um, zu dem dieses Dokument auf nationaler Ebene durch Verffentlichung einer identischen nationalen Norm oder durch Anerkennung bernommen werden muss (dop): 2014-05-19 sptestes Datum, zu dem nationale Normen, die diesem Dokument entgegenstehen, zurckgezogen werden mssen (dow): 2014-08-19 Dieses Dokum

22、ent ersetzt EN 61300-2-44:2008. EN 61300-2-44:2013 enthlt die folgenden wesentlichen technischen nderungen gegenber EN 61300-2-44:2008: a) berarbeitung von Bild 1; b) nderung der Faserlnge von der Biegestelle bis zum Gewicht. Es wird auf die Mglichkeit hingewiesen, dass einige Elemente dieses Dokume

23、nts Patentrechte berhren knnen. CENELEC und/oder CEN sind nicht dafr verantwortlich, einige oder alle diesbezglichen Patentrechte zu identifizieren. Anerkennungsnotiz Der Text der Internationalen Norm IEC 61300-2-44:2013 wurde von CENELEC ohne irgendeine Abnderung als Europische Norm angenommen. 2 D

24、IN EN 61300-2-44:2014-02 EN 61300-2-44:2013 Inhalt SeiteVorwort .2 1 Anwendungsbereich.4 2 Normative Verweisungen.4 3 Allgemeine Beschreibung 4 4 Prfaufbau4 4.1 Allgemeines4 4.2 Optische Quelle (S)5 4.3 Empfnger (D)5 4.4 Befestigungsvorrichtung.6 4.5 Biegeprfgert oder -gestell.6 5 Prfaufbau6 5.1 Vor

25、bereitung der Prflinge .6 5.2 Vorbehandlung.6 5.3 Anfangsmessungen .6 5.4 Beanspruchung 6 5.5 Nachbehandlung 6 5.6 Endmessungen 7 6 Prfschrfe.7 7 Festzulegende Einzelheiten.7 Anhang ZA (normativ) Normative Verweisungen auf internationale Publikationen mit ihren entsprechenden europischen Publikation

26、en8 Bilder Bild 1 Prfeinrichtung 5 Bild 2 Anwendung der Last bei einem Duplexkabel5 Tabellen Tabelle 1 Prfschrfen 7 3 DIN EN 61300-2-44:2014-02 EN 61300-2-44:2013 1 Anwendungsbereich Dieser Teil der IEC 61300 legt eine Prfung fest, um den Einfluss der Biegung unter Zugbelastung des zugentlastenden L

27、WL-Bauteils festzustellen. Ziel ist es, die Anzahl der Biegungen, wie sie im blichen Betrieb auftreten knnen, vorstzlich zu erzeugen. Diese Prfung kann auf einfaserige und mehrfaserige Kabel angewendet werden. 2 Normative Verweisungen Die folgenden Dokumente, die in diesem Dokument teilweise oder al

28、s Ganzes zitiert werden, sind fr die Anwendung dieses Dokuments erforderlich. Bei datierten Verweisungen gilt nur die in Bezug genommene Ausgabe. Bei undatierten Verweisungen gilt die letzte Ausgabe des in Bezug genommenen Dokuments (einschlielich aller nderungen). IEC 61300-1, Fibre optic interconn

29、ecting devices and passive components Basic test and measurement procedures Part 1: General and guidance IEC 61300-3-1, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 3-1: Examinations and measurements Visual examination IEC 61300-3-3, Fibre opt

30、ic interconnecting devices and passive components Basic test and measurement procedures Part 3-3: Examinations and measurements Active monitoring of changes in attenuation and return loss IEC 61300-3-4, Fibre optic interconnecting devices and passive components Basic test and measurement procedures

31、Part 3-4: Examinations and measurements Attenuation IEC 61753-1, Fibre optic interconnecting devices and passive components performance standard Part 1: General and guidance for performance standards 3 Allgemeine Beschreibung Der Prfling wird um 90 um eine Achse senkrecht zur Achse des befestigten K

32、abels gedreht, im Falle eines Bandkabels parallel zur Breite des Kabels. Dies erzeugt eine Biegung der Knickschutztlle und des Kabels nahe am Prfling. Whrend des Biegens wird eine Zugkraft, jedoch kein Drehmoment ausgebt. 4 Prfaufbau 4.1 Allgemeines Bild 1 zeigt die Prfeinrichtung und die zugehrigen

33、 Biegebewegungsmuster. 4 DIN EN 61300-2-44:2014-02 EN 61300-2-44:2013 Bild 1 Prfeinrichtung Im Falle eines Duplexkabels bzw. Bandkabels darf die Last nicht verdoppelt werden und das Kabel muss wie in Bild 2 gezeigt in Richtung der Nebenachse gebogen werden. Bild 2 Anwendung der Last bei einem Duplex

34、kabel Die benutzte Einrichtung wird in 4.2 bis 4.5 beschrieben. 4.2 Optische Quelle (S) Die empfohlene Quelle muss den Angaben in IEC 61300-3-3 bzw. IEC 61300-3-4 entsprechen. 4.3 Empfnger (D) Der empfohlene Empfnger muss den Angaben in IEC 61300-3-3 bzw. IEC 61300-3-4 entsprechen. 5 DIN EN 61300-2-

35、44:2014-02 EN 61300-2-44:2013 4.4 Befestigungsvorrichtung Mit der Befestigungsvorrichtung wird das zu prfende Lichtwellenleiterbauteil whrend der Prfung in einer stabilen, blichen Lage gehalten. Bei Steckverbindern darf die Befestigung eine Kupplung oder eine Anschlussbuchse sein. Die Befestigung da

36、rf das zu prfende Bauteil nicht verdrehen. Die Befestigung muss den Anschluss des Bauteils an die berwachungseinrichtung ermglichen. 4.5 Biegeprfgert oder -gestell Gert oder Gestell, welches das zu prfende Bauteil um 90 aus einer geraden Position dreht, wobei auf die Faser oder das Kabel eine Last a

37、usgebt wird. 5 Prfaufbau 5.1 Vorbereitung der Prflinge Der Prfling ist nach den Anweisungen des Herstellers vorzubereiten und zu reinigen. Durch Sichtprfung nach IEC 61300-3-1 ist festzustellen, ob die Befestigung des Kabels am Lichtwellen-leiterbauteil beschdigt ist. Faserlnge vom Biegepunkt zum Ge

38、wicht: (25 5) cm. Die Faserlnge ist vom Biegepunkt bis zu dem Punkt zu messen, an dem die Last anliegt. 5.2 Vorbehandlung Falls in der einschlgigen Spezifikation nicht anders festgelegt, sind der Prfling und die gesamte Prfeinrichtung mindestens 2 h unter Standardprfbedingungen, wie in IEC 61300-1 f

39、estgelegt, zu lagern. 5.3 Anfangsmessungen Die Anfangsuntersuchungen und -messungen am Prfling sind entsprechend der einschlgigen Spezifikation durchzufhren. 5.4 Beanspruchung Das zu prfende Bauteil wird in der Prfeinrichtung befestigt. Die Dmpfung des zu prfenden Bauteils wird mit dem Biegearm in s

40、enkrechter Position nach IEC 61300-3-4 gemessen. Bei einer festgelegten Anzahl von Biegungen ist die vorgegebene Zugbelastung anzulegen. Bei hchstens 20 Zyklen/min sind behutsame Drehbewegungen durchzufhren. Die Verweildauer in jeder Extremposition darf hchstens 5 s betragen. Die Dmpfungsnderung wir

41、d whrend der Prfung nach IEC 61300-3-3 gemessen. Die Biegebewegung wird mit dem Biegearm in senkrechter Position beendet. Die Zugbelastung wird zurck-genommen. 5.5 Nachbehandlung Falls in der einschlgigen Spezifikation nicht anders festgelegt, ist der Prfling mindestens 2 h unter Standardprfbedingun

42、gen, wie in IEC 61300-1 festgelegt, zu lagern. Der Prfling ist nach den Anweisungen des Herstellers zu reinigen. 6 DIN EN 61300-2-44:2014-02 EN 61300-2-44:2013 5.6 Endmessungen Das zu prfende Bauteil ist aus der Prfeinrichtung zu entfernen und Endmessungen sind wie in der einschlgigen Spezifikation

43、festgelegt durchzufhren, um sicherzustellen, dass keine bleibende Beschdi-gung am Prfling aufgetreten ist. Die Ergebnisse der Endmessung mssen die in der entsprechenden Spezifikation festgelegten Grenzwerte einhalten. Durch Sichtprfung nach IEC 61300-3-1 ist festzustellen, ob die Befestigung des Kab

44、els am Lichtwellen-leiterbauteil beschdigt ist. 6 Prfschrfe Die Prfschrfe wird durch die angelegte Zugkraft und die Anzahl der Biegezyklen von +90 bis 90 bestimmt. Empfohlene Werte fr Prfparameter sind in Tabelle 1 angegeben. Tabelle 1 Prfschrfen Kategorie aBauteil Zugkraft (N) Anzahl der Zyklen C S

45、teckverbinder Zugentlastete Kabel 2 100 C Passive Bauteile Zugentlastete Kabel 2 30 U und E Steckverbinder Zugentlastete Kabel 5 100 U und E Passive Bauteile Zugentlastete Kabel 5 30 O Passive Bauteile Zugentlastete ummantelte Kabel Primr- und sekundrbeschichtete Faser 5 2 30 30 O Steckverbinder Zug

46、entlastete ummantelte Kabel SSF-Steckverbinder 8,9 5,9 100 b100 baDie Kategorien sind in IEC 61753-1 enthalten. bIn (25 3) cm Abstand vom Kabeleingang zum Stecker. 7 Festzulegende Einzelheiten Folgende Einzelheiten mssen in der einschlgigen Spezifikation festgelegt werden: Gre der Zugbelastung; Anza

47、hl der Biegungen; anwendbares Lichtwellenleiterkabel (Typ, Lnge usw.); Anfangsuntersuchungen und -messungen und Anforderungen an das Betriebsverhalten; zulssige Dmpfungsabweichung whrend der Prfung; Enduntersuchungen und -messungen und Anforderungen an das Betriebsverhalten; Kriterien fr das Bestehe

48、n oder Nichtbestehen der Prfung; Abweichungen vom festgelegten Prfverfahren. 7 DIN EN 61300-2-44:2014-02 EN 61300-2-44:2013 8 Anhang ZA (normativ) Normative Verweisungen auf internationale Publikationen mit ihren entsprechenden europischen Publikationen Die folgenden Dokumente, die in diesem Dokument teilweise oder als Ganzes zitiert werden, sind fr die Anwendung dieses Dokuments erforderlich. Bei datierten Verweisungen gilt nur die in Bezug genommene Ausgabe. Bei undatierten Verweisungen gilt die letzte Ausgabe des in Bezug genommenen Dokuments (einschlieli

展开阅读全文
相关资源
  • DIN EN 818-7-2008 Short link chain for lifting purposes - Safety - Part 7 Fine tolerance hoist chain Grade T (Types T DAT and DT)(includes Amendment A1 2008) Ge.pdfDIN EN 818-7-2008 Short link chain for lifting purposes - Safety - Part 7 Fine tolerance hoist chain Grade T (Types T DAT and DT)(includes Amendment A1 2008) Ge.pdf
  • DIN EN 1677-3-2008 Components for slings - Safety - Part 3 Forged steel self-locking hooks Grade 8(includes Amendment A1 2008) English version of DIN EN 1677-3 .pdfDIN EN 1677-3-2008 Components for slings - Safety - Part 3 Forged steel self-locking hooks Grade 8(includes Amendment A1 2008) English version of DIN EN 1677-3 .pdf
  • DIN EN 1677-2-2008 Components for slings - Safety - Part 2 Forged steel lifting hooks with latch Grade 8(includes Amendment A1 2008) English version of DIN EN 1.pdfDIN EN 1677-2-2008 Components for slings - Safety - Part 2 Forged steel lifting hooks with latch Grade 8(includes Amendment A1 2008) English version of DIN EN 1.pdf
  • DIN EN 1670-2007 Building hardware - Corrosion resistance - Requirements and test methods English version of DIN EN 1670 2007-06《建筑五金器具 耐腐蚀 要求和试验方法》.pdfDIN EN 1670-2007 Building hardware - Corrosion resistance - Requirements and test methods English version of DIN EN 1670 2007-06《建筑五金器具 耐腐蚀 要求和试验方法》.pdf
  • DIN EN 1656-2010 Chemical disinfectants and antiseptics - Quantitative suspension test for the evaluation of bactericidal activity of chemical disinfectants and.pdfDIN EN 1656-2010 Chemical disinfectants and antiseptics - Quantitative suspension test for the evaluation of bactericidal activity of chemical disinfectants and.pdf
  • DIN EN 1230-2-2018 Paper and board intended to come into contact with foodstuffs - Sensory analysis - Part 2 Off-flavour (taint) German version EN 1230-2 2009《用.pdfDIN EN 1230-2-2018 Paper and board intended to come into contact with foodstuffs - Sensory analysis - Part 2 Off-flavour (taint) German version EN 1230-2 2009《用.pdf
  • DIN EN 1176-7-2008 Playground equipment and surfacing - Part 7 Guidance on installation inspection maintenance and operation English version of DIN EN 1176-7 20.pdfDIN EN 1176-7-2008 Playground equipment and surfacing - Part 7 Guidance on installation inspection maintenance and operation English version of DIN EN 1176-7 20.pdf
  • DIN EN 1176-5-2008 Playground equipment and surfacing - Part 5 Additional specific safety requirements and test methods for carousels English version of DIN EN .pdfDIN EN 1176-5-2008 Playground equipment and surfacing - Part 5 Additional specific safety requirements and test methods for carousels English version of DIN EN .pdf
  • DIN EN 1159-1-2007 Advanced technical ceramics - Ceramic composites - Thermophysical properties - Part 1 Determination of thermal expansion (includes Corrigendu.pdfDIN EN 1159-1-2007 Advanced technical ceramics - Ceramic composites - Thermophysical properties - Part 1 Determination of thermal expansion (includes Corrigendu.pdf
  • DIN EN 1093-4-2008 Safety of machinery - Evaluation of the emission of airborne hazardous substances - Part 4 Capture efficiency of an exhaust system - Tracer m.pdfDIN EN 1093-4-2008 Safety of machinery - Evaluation of the emission of airborne hazardous substances - Part 4 Capture efficiency of an exhaust system - Tracer m.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > DIN

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1