1、April 2010 Translation by DIN-Sprachendienst.English price group 14No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS
2、91.140.60; 93.030!$b)3“1630616www.din.deDDIN EN ISO 1452-2Plastics piping systems for water supply and for buried andabove-ground drainage and sewerage under pressure Unplasticized poly(vinyl chloride) (PVC-U) Part 2: Pipes (ISO 1452-2:2009)English translation of DIN EN ISO 1452-2:2010-04Kunststoff-
3、Rohrleitungssysteme fr die Wasserversorgung und fr erdverlegte und nichterdverlegte Entwsserungs- und Abwasserdruckleitungen Weichmacherfreies Polyvinylchlorid (PVC-U) Teil 2: Rohre (ISO 1452-2:2009)Englische bersetzung von DIN EN ISO 1452-2:2010-04Systmes de canalisations en plastique pour laliment
4、ation en eau, pour branchements etcollecteurs dassainissement enterrs et ariens avec pression Poly(chlorure de vinyle) non plastifi (PVC-U) Partie 2: Tubes (ISO 1452-2:2009)Traduction anglaise de DIN EN ISO 1452-2:2010-04Together with DIN EN ISO 1452-1:2010-04, DIN EN ISO 1452-3:2010-04, DIN EN ISO
5、1452-4:2010-04 andDIN EN ISO 1452-5:2010-04 supersedes DIN EN 1456-1:2001-12;supersedes DIN EN 1452-2:1999-09Supersedes: see belowwww.beuth.deIn case of doubt, the German-language original shall be considered authoritative.Document comprises 31 pages04.10 DIN EN ISO 1452-2:2010-04 2 A comma is used
6、as the decimal marker. National foreword This standard has been prepared by Technical Committee ISO/TC 138 “Plastics pipes, fittings and valves for the transport of fluids”, Subcommittee SC 2 “Plastics pipes and fittings for water supplies” (Secretariat: SNV, Switzerland), in collaboration with Tech
7、nical Committee CEN/TC 155 “Plastics piping systems and ducting systems” (Secretariat: NEN, Netherlands). The responsible German body involved in its preparation was the Normenausschuss Wasserwesen (Water Practice Standards Committee), Joint Working Committees NA 119-04-06 GA Kunststoffrohre in der
8、Trink-wasserversorgung and NA 119-04-06-03 GUA PVC-Rohre. The DIN Standards corresponding to the International Standards referred to in clause 2 of the EN are as follows, whereby EN ISO Standards are only listed below if these have not been published as DIN EN ISO Standards with the same number: ISO
9、 1167-1 DIN EN ISO 1167-1 ISO 1167-2 DIN EN ISO 1167-2 ISO 1183-1 DIN EN ISO 1183-1 ISO 1452-1 DIN EN ISO 1452-1 ISO 1452-5 DIN EN ISO 1452-5 ISO 2505 DIN EN ISO 2505 ISO 3126 DIN EN ISO 3126 ISO 6259-1 DIN EN ISO 6259-1 ISO 7686 DIN EN ISO 7686 ISO 9311-1 DIN EN ISO 9311-1 Amendments This standard
10、differs from DIN EN 1452-2:1999-09 and DIN EN 1456-1:2001-12 as follows: a) The content of the standards has been combined in one standard. b) The scope has been rendered more precise (solid-wall pipes). c) Normative references have been modified or updated. d) Specifications relating to the minimum
11、 strength have been revised. e) Requirements concerning the opacity have been given in more detail. f) Pipe series S 16,7 has been deleted. g) The nominal inside diameter of sockets for solvent cementing has been supplemented by dn355 and dn400. h) The nominal inside diameter of sockets for elastome
12、ric ring seal joints has been supplemented by dn20 and dn25. i) Specifications relating to pipe ends for ring seal or solvent cement joints have been revised. j) Requirements relating to the resistance to internal pressure have been revised. DIN EN ISO 1452-2:2010-04 3 k) Alternative test methods ha
13、ve been included for testing the resistance to dichloromethane. l) Some values in Table 9 “Physical characteristics” have been corrected. m) Specifications relating to chemical characteristics are now dealt with in DIN EN ISO 1452-1. n) The minimum required marking has been extended to include the i
14、ntended use and further information to be supplied by the manufacturer. o) Specifications relating to the out-of-roundness of sockets for solvent cementing for imperial (inch)-sized pipes have been rendered more precise. p) Specifications relating to the fracture toughness of imperial (inch)-sized p
15、ipes have been deleted. Previous editions DIN 19532: 1966-05, 1976-03, 1979-07 DIN EN 1452-2: 1999-09 DIN EN 1456-1: 2001-12 National Annex NA (informative) Bibliography DIN EN ISO 1167-1, Thermoplastics pipes, fittings and assemblies for the conveyance of fluids Determination of the resistance to i
16、nternal pressure Part 1: General method DIN EN ISO 1167-2, Thermoplastics pipes, fittings and assemblies for the conveyance of fluids Determination of the resistance to internal pressure Part 2: Preparation of pipe test pieces DIN EN ISO 1183-1, Plastics Methods for determining the density of non-ce
17、llular plastics Part 1: Immersion method, liquid pyknometer method and titration method DIN EN ISO 1452-1, Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure Unplasticized poly(vinyl chloride) (PVC-U) Part 1: General DIN EN ISO 1452-5, Plast
18、ics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure Unplasticized poly(vinyl chloride) (PVC-U) Part 5: Fitness for purpose of the system DIN EN ISO 2505, Thermoplastics pipes Longitudinal reversion Test methods and parameters DIN EN ISO 3126, Plas
19、tics piping systems Plastics components Determination of dimensions DIN EN ISO 6259-1, Thermoplastics pipes Determination of tensile properties Part 1: General test method DIN EN ISO 7686, Plastics pipes and fittings Determination of opacity DIN EN ISO 9311-1, Adhesives for thermoplastic piping syst
20、ems Part 1: Determination of film properties DIN EN ISO 1452-2:2010-04 4 This page is intentionally blank EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN ISO 1452-2 December 2009 ICS 91.140.60; 93.025; 23.040.20; 23.040.45 Supersedes EN 1452-2:1999, EN 1456-1:2001English Version Plastics piping
21、 systems for water supply and for buried and above-ground drainage and sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 2: Pipes (ISO 1452-2:2009) Systmes de canalisations en plastique pour lalimentation en eau, pour branchements et collecteurs dassainissement enterrs et a
22、riens avec pression - Poly(chlorure de vinyle) non plastifi (PVC-U) - Partie 2: Tubes (ISO 1452-2:2009)Kunststoff-Rohrleitungssysteme fr die Wasserversorgung und fr erdverlegte und nicht erdverlegte Entwsserungs- und Abwasserdruckleitungen - Weichmacherfreies Polyvinylchlorid (PVC-U) - Teil 2: Rohre
23、 (ISO 1452-2:2009)This European Standard was approved by CEN on 4 November 2009. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and b
24、ibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibil
25、ity of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland,
26、 Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Mar
27、nix 17, B-1000 Brussels 2009 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN ISO 1452-2:2009: EContents DIN EN ISO 1452-2:2010-04 EN ISO 1452-2:2009 (E) 2 Page Foreword3 Introduction .4 1 Scope 5 2 Normative references 5 3 Terms, d
28、efinitions, symbols and abbreviated terms6 4 Material .7 4.1 Pipe material.7 4.2 Density7 4.3 MRS-value.7 5 General characteristics .7 5.1 Appearance 7 5.2 Colour .7 5.3 Opacity of pipes intended for the above-ground conveyance of water.7 6 Geometrical characteristics7 6.1 Measurement of dimensions
29、7 6.2 Nominal outside diameters.7 6.3 Mean outside diameters and their tolerances 8 6.4 Wall thickness and their tolerances.9 6.5 Length of pipe . 10 6.6 Pipes with sockets 11 6.7 Pipe ends for ring seal or solvent cement joints. 15 7 Classification and selection of pipes . 15 7.1 Classification. 15
30、 7.2 Selection of nominal pressure and pipe series S for water up to and including 25 C. 15 7.3 Determination of the allowable operating pressure for water up to 45 C . 15 8 Mechanical characteristics 15 8.1 Impact strength. 15 8.2 Resistance to internal pressure 16 9 Physical characteristics. 17 10
31、 Sealing rings . 18 11 Adhesives 18 12 Performance requirements 18 13 Marking 18 13.1 General. 18 13.2 Minimum required marking 18 13.3 Additional marking . 19 Annex A (normative) Allowable operating pressures 20 Annex B (normative) Imperial (inch)-sized pipes 22 Bibliography. 27 Foreword This docum
32、ent (EN ISO 1452-2:2009) has been prepared by Technical Committee CEN/TC 155 “Plastics This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by June 2010, and conflicting national standards shall be withdr
33、awn at the latest by June 2010. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 1452-2:1999, EN 1456-1:200
34、1. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Ital
35、y, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. piping systems and ducting systems”, the secretariat of which is held by NEN, in collaboration with Technical Committee ISO/TC 138 “Plastics
36、 pipes, fittings and valves for the transport of fluids”. DIN EN ISO 1452-2:2010-04 EN ISO 1452-2:2009 (E) 3 Introduction The System Standard, of which this is Part 2, specifies the requirements for a piping system and its components made from unplasticized poly(vinyl chloride) (PVC-U). The piping s
37、ystem is intended to be used for water supply and for buried and above-ground drainage and sewerage under pressure. In respect of potential adverse effects on the quality of water intended for human consumption, caused by the products covered by this part of ISO 1452, the following are relevant. a)
38、This part of ISO 1452 provides no information as to whether or not the products can be used without restriction. b) Existing national regulations concerning the use and/or the characteristics of these products remain in force. Requirements and test methods for material and components, other than pip
39、es, are specified in ISO 1452-1, ISO 1452-3 and ISO 1452-4. Characteristics for fitness for purpose (mainly for joints) are established in ISO 1452-5. This part of ISO 1452 specifies the characteristics of pipes. Guidance for installation is given in ISO/TR 41911. Guidance for assessment of conformi
40、ty is provided in ENV 1452-72. DIN EN ISO 1452-2:2010-04 EN ISO 1452-2:2009 (E) 4 1 Scope This part of ISO 1452 specifies the characteristics of solid-wall pipes made from unplasticized poly(vinyl chloride) (PVC-U) for piping systems intended for water supply and for buried and above-ground drainage
41、 and sewerage under pressure. It also specifies the test parameters for the test methods referred to in this part of ISO 1452. In conjunction with ISO 1452-1 and ISO 1452-5, it is applicable to extruded PVC-U pipes without a socket and pipes with a socket (integral or not), intended to be used for t
42、he following: a) water mains and services buried in the ground; b) conveyance of water above ground for both outside and inside buildings; c) buried and above-ground drainage and sewerage under pressure. It is applicable to piping systems intended for the supply of water under pressure up to and inc
43、luding 25 C (cold water) intended for human consumption and for general purposes as well as for waste water under pressure. This part of ISO 1452 specifies pipes for the conveyance of water and waste water up to and including 45 C. For temperatures between 25 C and 45 C, Figure A.1 applies. NOTE 1 T
44、he producer and the end-user can come to agreement on the possibilities of use for temperatures above 45 C on a case-by-case basis. This part of ISO 1452 specifies a range of pipe sizes and pressure classes, and gives requirements concerning colours. NOTE 2 It is the responsibility of the purchaser
45、or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes. 2 Normative references The following referenced documents are indispensable for the application of this doc
46、ument. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 1167-1, Thermoplastics pipes, fittings and assemblies for the conveyance of fluids Determination of the resistance to internal pr
47、essure Part 1: General method DIN EN ISO 1452-2:2010-04 EN ISO 1452-2:2009 (E) 5 ISO 1167-2, Thermoplastics pipes, fittings and assemblies for the conveyance of fluids Determination of the resistance to internal pressure Part 2: Preparation of pipe test pieces ISO 1183-1:2004, Plastics Methods for d
48、etermining the density of non-cellular plastics Part 1: Immersion method, liquid pyknometer method and titration method ISO 1452-1:2009, Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure Unplasticized poly(vinyl chloride) (PVC U) Part 1: Ge
49、neral ISO 1452-5, Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure Unplasticized poly(vinyl chloride) (PVC U) Part 5: Fitness for purpose of the system ISO 2505, Thermoplastics pipes Longitudinal reversion Test method and parameters ISO 2507-1:1995, Thermoplastics pipes and fittings Vicat softening temperature Part 1: General test method ISO 3126, Plastics piping systems Plastics components Determination