1、Beneficial comments recommendations, additions, deletions, clarifications, etc., and any data which may improve this document should be addressed to: DLA Land and Maritime, Columbus, ATTN: VAT, Post Office Box 3990, Columbus, OH 43218-3990, or email (transformersdla.mil). Since contact Information c

2、an change you may want to verify the currency of the address information using the ASSIST Online database at https:/assist.dla.mil. AMSC N/A FSC 5950 A-A-59699B 5 December 2013 SUPERSEDING A-A-59699A 9 May 2008 COMMERCIAL ITEM DESCRIPTION COIL, RF, CHIP, FIXED, HIGH INDUCTANCE, SURFACE MOUNT The Gen

3、eral Services Administration has authorized the use of this commercial item description (CID) for all federal agencies. 1. SCOPE. This CID covers the general requirements for a radio frequency coil. Coils covered by this CID are intended for commercial/industrial applications. 2. CLASSIFICATION. Thi

4、s CID uses a classification system which is included in the Part Identification Number (PIN) as shown in the following example (see 7.1). AA59699 - 001 F T CID number Dash number (see table I) Inductance Tolerance (see table II) (Optional) Termination finish (see table III) 3. SALIENT CHARACTERISTIC

5、S. 3.1 Interface and physical dimensions. Coils supplied to this CID shall be as specified herein. (see figure 1). 3.2. Electrical characteristics. The electrical characteristics shall be as specified in table I. 3.3 Weight. The weight shall be no greater than 0.5 gram maximum. 3.4 Operating tempera

6、ture range. The operating temperature range is 40C to +85C. 3.5 Temperature rise. DC current rating for a 15C rise. 3.6 Altitude. The maximum altitude is 70,000 feet. 3.7 Marking. Inductors supplied to this CID shall be marked with the manufacturers standard commercial PIN. 3.8 Pure tin. The use of

7、pure tin, as an underplate or final finish is prohibited both internally and externally. Tin content of transformer components and solder shall not exceed 97 percent, by mass. Tin shall be alloyed with a minimum of 3 percent lead, by mass. 3.9 Recycled, recovered, or environmentally preferable mater

8、ials. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent possible provided that the material meets or exceeds the operational and maintenance requirements, and promotes economically advantageous life cycle costs. 3.10 Workmanship. Inductors shall be pro

9、cessed in such a manner as to be uniform in quality and shall be free from other defects that will affect life, serviceability, or appearance.INCH-POUNDProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59699B 2 Dimension INCHES MM A Ref B Ref C D E

10、 F Ref G Ref H .097 - .103 .175 - .181 .135 Max. .195 Max. .150 Max. .010 - .030 .020 - .030 .070 Ref. 2.46 2.61 4.44 4.59 3.43 Max. 4.95 Max. 3.81 Max. .254 - .762 .508 - .762 1.78 Ref. NOTES: 1. Dimensions are in Inches. 2. Metric equivalents are listed for general information only. FIGURE 1. Conf

11、iguration and dimensions. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59699B 3 TABLE I. Electrical characteristics. CID dash number AA59699- Inductance(H) Tolerance (%) Q Min Test Frequency (MHz) SRF Min (MHz) DCR Max (OHMS) 1/ IDCMAX (mA) 00

12、1* 12.0 5 42 2.5 55 2.0 310 002* 15.0 5 42 2.5 45 2.5 290 003* 18.0 5 45 2.5 37 2.8 270 004* 22.0 5 45 2.5 32 3.2 260 005* 27.0 5 45 2.5 27 3.6 240 006* 33.0 5 45 2.5 23 4.0 230 007* 39.0 5 45 2.5 19 4.5 210 008* 47.0 5 42 2.5 16 5.0 200 009* 56.0 5 42 2.5 13 5.5 190 010* 68.0 5 40 2.5 10 6.0 180 01

13、1* 82.0 5 40 2.5 9 7.0 170 012* 100.0 5 40 2.5 8.5 8.0 150 013* 120.0 5 33 0.79 8.5 11.5 135 014* 150.0 5 36 0.79 8.5 13.0 125 015* 180.0 5 38 0.79 8.0 14.2 120 016* 220.0 5 38 0.79 6.0 16.2 115 017* 270.0 5 38 0.79 5.0 20.5 105 018* 330.0 5 38 0.79 4.5 22.5 100 019* 390.0 5 38 0.79 3.5 24.5 90 020*

14、 470.0 5 38 0.79 3.0 26.5 85 021* 560.0 5 33 0.79 2.0 28.5 75 022* 680.0 5 33 0.79 1.9 38.0 60 023* 820.0 5 30 0.79 1.6 41.0 55 024* 1000.0 5 30 0.79 1.5 44.0 50 1/ DC current rating for a 15C rise. TABLE II. Inductance tolerances Code Tolerance (percentage) J 5 Provided by IHSNot for ResaleNo repro

15、duction or networking permitted without license from IHS-,-,-A-A-59699B 4 TABLE III. Termination finish. Code Termination finishLeave blank L T Tin-lead RoHS compliant, silver-palladium-platinum-glass-frit RoHS, tin-silver-copper (95.5/4/0.5) 4. REGULATORY REQUIREMENTS. The offeror/contractor is enc

16、ouraged to use recovered materials to the maximum extent practicable, in accordance with paragraph 23.403 of the Federal Acquisition Regulation (FAR). 5. PRODUCT CONFORMANCE PROVISIONS 5.1 Product conformance. The products provided shall meet the salient characteristics of this CID, conform to the p

17、roducers own drawings, specifications, standards, and quality assurance practices, and be the same product offered for sale in the commercial market. The Government reserves the right to require proof of such conformance. 5.2 Market acceptance. The following market acceptance criteria are necessary

18、to document the quality of the product to be provided under this CID: a. The company producing the item must have been producing a product meeting the requirements of this CID for at least 2 years. b. The company must have sold 1,000 units meeting this CID in the commercial marketplace over the past

19、 2 years. 6. PACKAGING. Preservation, packing, and marking shall be as specified in the contract or order. 7. NOTES. 7.1 PIN. The PIN should be used for Government purposes to buy commercial products to this CID. See section 2 for PIN format example. 7.2 Environmentally preferable material. Environm

20、entally preferable materials should be used to the maximum extent possible to meet the requirements of this specification. As of the dating of this document, the U.S. Environmentally Protection Agency (EPA) is focusing efforts on reducing 31 priority chemicals. The list of chemicals is available on

21、their website at http:/www.epa.gov/epaoswer/hazwaste/minimize/chemlist.htm. Further information is available at the following EPA site: http:/www.epa.gov/epaoswer/hazwaste/minimize/. Included in the EPA list of 31 priority chemicals are cadmium, lead, and mercury. Use of the materials on the list sh

22、ould be minimized or eliminated unless needed to meet the requirements specified herein (see Section 3). 7.3 Commercial and Government Entity (CAGE) code. For ordering purposes, inventory control, and submission of these inductors to DSCC under the Military Parts Control Advisory Group (MPCAG) evalu

23、ation program, CAGE code 58536 should be used. 7.4 Source of documents. FEDERAL REGULATIONS FAR - Federal Acquisition Regulations (FAR) (Copies of these documents are available online at www.acquisition.gov/comp/far/index.html or from the U.S. Government Printing Office, 732 North Capital Street, NW

24、 Washington D.C. 20401.) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59699B 5 7.5 Tin whisker growth. The use of alloys with tin content greater than 97 percent, by mass, may exhibit tin whisker growth problems after manufacture. Tin whisker

25、s may occur anytime from a day to years after manufacture and can develop under typical operating conditions, on products that use such materials. Conformal coatings applied over top of a whisker-prone surface will not prevent the formation of tin whiskers. Alloys of 3 percent lead, by mass, have sh

26、own to inhibit the growth of tin whiskers. For additional information on this matter, refer to ASTM-B545 (Standard Specification for Electrodeposited Coatings of Tin) 7.6 Ordering data. The contract or order should specify the following: a. CID document number, revision, and CID PIN. b. Product conf

27、ormance provisions. c. Packaging requirements. 7.7 Commercial products. As part of the market analysis and research effort, this CID was coordinated with the following manufacturers of commercial products. At the time of CID preparation and coordination, these manufacturers were known to have commer

28、cial products that would meet the requirements of this CID. (NOTE: This information should not be considered as a list of approved manufacturers or be used to restrict procurement to only the manufacturers shown.) MFRs CAGE MFRs name and address 02113 Coilcraft Inc 1102 Silver Lake Road Cary, Illino

29、is 60013-1658 Phone number (847) 639-2361 Uniform Resource Locator (URL): 7.8 Part number (P/N) supersession data. This CID supersedes the following manufacturers P/Ns as shown. This information is being provided to assist in reducing proliferation in the government inventory system. TABLE II. P/N

30、supersession data. 1/ CID dash number (see table I) AA59699- Vendor commercial PIN 2/ CAGE 02113 CID dash number (see table I) AA59699- Vendor commercial PIN 2/ CAGE 02113 001* 1812LS-123X* 013* 1812LS-124X* 002* 1812LS-153X* 014* 1812LS-154X* 003* 1812LS-183X* 015* 1812LS-184X* 004* 1812LS-223X* 01

31、6* 1812LS-224X* 005* 1812LS-273X* 017* 1812LS-274X* 006* 1812LS-333X* 018* 1812LS-334X* 007* 1812LS-393X* 019* 1812LS-394X* 008* 1812LS-473X* 020* 1812LS-474X* 009* 1812LS-563X* 021* 1812LS-564X* 010* 1812LS-683X* 022* 1812LS-684X* 011* 1812LS-823X* 023* 1812LS-824X* 012* 1812LS-104X* 024* 1812LS-10

32、5X* 1/ When “*“ is used for coded values, its the contractors responsibility to select those options allowed by the CID. 2/ The manufacturers P/N shall not be used for procurement to the requirements of this CID. At the time of preparation of this CID, the aforementioned commercial products were rev

33、iewed and could be replaced by the CID P/N shown. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59699B 6 7.9 Government users. To acquire information on obtaining these coils from the Government inventory system, contact DLA Land and Maritime,

34、ATTN: DSCC-FMTC, Post Office Box 3990, Columbus, OH 43218-3990, or telephone (614) 692-7727. 7.10 Changes from previous issue. The margins of this CID are marked with asterisks to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes

35、 no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. MILITARY INTERESTS: CIVIL AGENCY COORD

36、INATING ACTIVITY: GSA - 7FXE Custodians: Navy - EC Preparing Activity: DLA - CC DLA - CC Project 5950-2013-014 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.dla.mil . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • ASTM E2475-2010(2016) Standard Guide for Process Understanding Related to Pharmaceutical Manufacture and Control《与药物制造和控制相关的工艺理解的标准指南》.pdf ASTM E2475-2010(2016) Standard Guide for Process Understanding Related to Pharmaceutical Manufacture and Control《与药物制造和控制相关的工艺理解的标准指南》.pdf
  • ASTM E2476-2009 Standard Guide for Risk Assessment and Risk Control as it Impacts the Design Development and Operation of PAT Processes for Pharmaceutical Manufacture《影响到PAT过程的设计、制.pdf ASTM E2476-2009 Standard Guide for Risk Assessment and Risk Control as it Impacts the Design Development and Operation of PAT Processes for Pharmaceutical Manufacture《影响到PAT过程的设计、制.pdf
  • ASTM E2476-2016 Standard Guide for Risk Assessment and Risk Control as it Impacts the Design Development and Operation of PAT Processes for Pharmaceutical Manufacture《影响PAT过程的设计 制定.pdf ASTM E2476-2016 Standard Guide for Risk Assessment and Risk Control as it Impacts the Design Development and Operation of PAT Processes for Pharmaceutical Manufacture《影响PAT过程的设计 制定.pdf
  • ASTM E2478-2006a Standard Practice for Determining Damage-Based Design Stress for Fiberglass Reinforced Plastic (FRP) Materials Using Acoustic Emission《玻璃纤维整形加固材料(FRP)的基于损害的设计标准测定的.pdf ASTM E2478-2006a Standard Practice for Determining Damage-Based Design Stress for Fiberglass Reinforced Plastic (FRP) Materials Using Acoustic Emission《玻璃纤维整形加固材料(FRP)的基于损害的设计标准测定的.pdf
  • ASTM E2478-2011 Standard Practice for Determining Damage-Based Design Stress for Glass Fiber Reinforced Plastic (GFRP) Materials Using Acoustic Emission《用声发射测定玻璃纤维增强塑料(FRP)材料基于损伤的设.pdf ASTM E2478-2011 Standard Practice for Determining Damage-Based Design Stress for Glass Fiber Reinforced Plastic (GFRP) Materials Using Acoustic Emission《用声发射测定玻璃纤维增强塑料(FRP)材料基于损伤的设.pdf
  • ASTM E2478-2011(2016) Standard Practice for Determining Damage-Based Design Stress for Glass Fiber Reinforced Plastic (GFRP) Materials Using Acoustic Emission《采用声发射测定玻璃纤维增强塑料 (GFRP.pdf ASTM E2478-2011(2016) Standard Practice for Determining Damage-Based Design Stress for Glass Fiber Reinforced Plastic (GFRP) Materials Using Acoustic Emission《采用声发射测定玻璃纤维增强塑料 (GFRP.pdf
  • ASTM E2479-2006 Standard Practice for Measuring the Ultrasonic Velocity in Polyethylene Tank Walls Using Lateral Longitudinal (LCR) Waves《利用侧向纵波(L)测定聚乙烯容器壁中超声波速度的标准实施规程》.pdf ASTM E2479-2006 Standard Practice for Measuring the Ultrasonic Velocity in Polyethylene Tank Walls Using Lateral Longitudinal (LCR) Waves《利用侧向纵波(L)测定聚乙烯容器壁中超声波速度的标准实施规程》.pdf
  • ASTM E2479-2011 Standard Practice for Measuring the Ultrasonic Velocity in Polyethylene Tank Walls Using Lateral Longitudinal (LCR) Waves《采用外侧纵(LCR)波测量聚乙烯罐壁超声波传播速度的标准操作规程》.pdf ASTM E2479-2011 Standard Practice for Measuring the Ultrasonic Velocity in Polyethylene Tank Walls Using Lateral Longitudinal (LCR) Waves《采用外侧纵(LCR)波测量聚乙烯罐壁超声波传播速度的标准操作规程》.pdf
  • ASTM E2479-2016 Standard Practice for Measuring the Ultrasonic Velocity in Polyethylene Tank Walls Using Lateral Longitudinal (LCR) Waves《采用横向纵向波 (LCR) 测量聚乙烯储罐壁的超声波速度的标准实施规程》.pdf ASTM E2479-2016 Standard Practice for Measuring the Ultrasonic Velocity in Polyethylene Tank Walls Using Lateral Longitudinal (LCR) Waves《采用横向纵向波 (LCR) 测量聚乙烯储罐壁的超声波速度的标准实施规程》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1