DLA DSCC-DWG-10021-2013 CONNECTOR ELECTRICAL COAXIAL RADIO FREQUENCY ADAPTER ELECTRICAL COAXIAL RF SOCKET CONTACT SERIES SMPS TO SMPS.pdf

上传人:jobexamine331 文档编号:688708 上传时间:2018-12-30 格式:PDF 页数:5 大小:56.59KB
下载 相关 举报
DLA DSCC-DWG-10021-2013 CONNECTOR ELECTRICAL COAXIAL RADIO FREQUENCY ADAPTER ELECTRICAL COAXIAL RF SOCKET CONTACT SERIES SMPS TO SMPS.pdf_第1页
第1页 / 共5页
DLA DSCC-DWG-10021-2013 CONNECTOR ELECTRICAL COAXIAL RADIO FREQUENCY ADAPTER ELECTRICAL COAXIAL RF SOCKET CONTACT SERIES SMPS TO SMPS.pdf_第2页
第2页 / 共5页
DLA DSCC-DWG-10021-2013 CONNECTOR ELECTRICAL COAXIAL RADIO FREQUENCY ADAPTER ELECTRICAL COAXIAL RF SOCKET CONTACT SERIES SMPS TO SMPS.pdf_第3页
第3页 / 共5页
DLA DSCC-DWG-10021-2013 CONNECTOR ELECTRICAL COAXIAL RADIO FREQUENCY ADAPTER ELECTRICAL COAXIAL RF SOCKET CONTACT SERIES SMPS TO SMPS.pdf_第4页
第4页 / 共5页
DLA DSCC-DWG-10021-2013 CONNECTOR ELECTRICAL COAXIAL RADIO FREQUENCY ADAPTER ELECTRICAL COAXIAL RF SOCKET CONTACT SERIES SMPS TO SMPS.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 AMSC N/A 5935-E838-003 REVISIONS LTR DESCRIPTION DATE APPROVED REV PAGE REV STATUS OF PAGES REV PAGE 1 2 3 4 5 PMIC G PREPARED BY DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OHIO 43218-3990 Jeremy Funk Original date of drawing 04 September 2013 CHECKED BY TITLE Jeremy Funk CONNECTOR, ELECTRICAL, COAX

2、IAL, RADIO FREQUENCY, ADAPTER, ELECTRICAL, COAXIAL, RF, SOCKET CONTACT, SERIES SMPS TO SMPS APPROVED BY Abdonasser Abdouni SIZE CAGE CODE DWG. NO. 10021 A 037Z3 REV PAGE 1 OF 5 CURRENT DESIGN ACTIVITY CAGE CODE 037Z3 HAS CHANGED NAMES TO: DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 Provided by I

3、HSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE DWG NO. A 037Z3 10021 REV PAGE 2 ENGINEERING DATA: Nominal impedance: 50 ohms. Frequency range: DC to 100 GHz. RF leakage: -80 dB to 3 GHz. -65

4、dB from 3 to 26.5 GHz minimum. Voltage rating: 168 V rms maximum at sea level. 33 V rms at 70,000 feet. Operating temperature: -65C to +165C. Inches mm .009 .023 .063 1.60 .068 1.73 .098 2.49 .110 2.79 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for information only. 3. All u

5、ndimensioned pictorial configurations are for reference purposes only. 4. Special tools shall be required for assembly. Contact manufacturer. FIGURE 1. General configuration, adapter. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE SUPPLY CEN

6、TER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE DWG NO. A 037Z3 10021 REV PAGE 3 REQUIREMENTS: (All electrical and mechanical requirements shall be maintained during radial misalignment. Requirements of drawing 84148 are applicable.) Dimensions and configurations: See figure 1. Interface dimens

7、ions: In accordance with MIL-STD-348. Force to engage: Full detent: 4 pounds maximum. Smooth bore: 2 pounds maximum. Force to disengage: 2 pounds minimum - full detent 0.5 pounds minimum - smooth bore Center contact inspection conditions (after heat treat) Oversize test pin: Test pin diameter: .0105

8、 inch +.0001/-.0000 inch. Insertion depth: .010 inch minimum, .020 inch maximum. Number of insertions: 1 Insertion force test: Test pin diameter: .0100 inch +.0001/-.0000 inch. Insertion force: 10 ounces, maximum. Insertion depth: .015 inch minimum, .025 inch maximum. Withdrawal force test: Test pin

9、 diameter: .0080 +0000/-.0001 inch. Withdrawal force: 0.25 ounce, minimum. Insertion depth: .015 inch minimum, .025 inch maximum. Radial misalignment: Total radial misalignment between centerlines of connector shroud or mating planes, .008 inch (0.25 mm), min. Axial misalignment: .000/.008 (0.00/0.2

10、0 mm). Coupling proof torque: Not applicable. Hermetic seal: Not applicable. Leakage (pressurized connectors): Not applicable. Center contact retention: .75 pounds minimum axial force Radial torque: Not applicable. Provided by IHSNot for ResaleNo reproduction or networking permitted without license

11、from IHS-,-,-DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE DWG NO. A 037Z3 10021 REV PAGE 4 Voltage standing wave ratio: DC to 40 gigahertz: 1.15:1 maximum. 40 to 65 gigahertz: 1.25:1 maximum. VSWR procedure. The VSWR shall be measured in accordance with the following proced

12、ure or a method acceptable to the Government. Part should be tested using a Network Analyzer with the Time Domain (TDR) option installed. This is essential to allow the effect of the adapters to be “gated” out. The recommended network analyzer systems include Hewlett Packard HP 8510. Wiltron 360 or

13、equivalent. The printer/plotter and the computer should be any unit compatible to the system. The device under test (DUT) shall consist of DSCC PIN 10021 mated at both ends with adapters capable of performing to 65 GHz . Calibration of the system should be performed using the manufacturers calibrati

14、on kits and the recommended calibration procedures. The frequency range shall be DC to 65 GHz. The VSWR calibration test setup shall be verified using the manufacturers verification kits. The calibrated system VSWR shall be less than 1.02 + .001F (F in GHZ). The VSWR of the DUT shall be measured usi

15、ng the procedures described in the manufacturers operating instructions. The time domain shall then be used to remove the effects of the test adapter. The output shall be generated using the appropriate printer/plotter. Moisture resistance: MIL-STD-202, method 106, except step 7b shall be omitted. R

16、esistance shall be 1,000 megohms within 5 minutes after removal from humidity Contact resistance (in milliohms, maximum): Initial Center contact 6.0 Outer contact 2.0 Dielectric withstanding voltage at sea level: 250 V rms minimum. 50 V rms at 70,000 feet. Vibration, high frequency: MIL-STD-202, met

17、hod 204, test condition D. Vibration, random: MIL-STD-202, method 214, test condition F, duration 15 minutes, minimum. Corona level : Altitude: 70,000 feet. 100 V rms, minimum. Insulation resistance: 3,500 megohms minimum when tested in accordance with MIL-PRF-39012 . Altitude: Sea level to 70,000 f

18、eet. Solderability (when applicable): Not applicable. Shock (specified pulse): MIL-STD-202, method 213, test condition I. Thermal shock: MIL-STD-202, method 107, test condition B (except high temperature to be +165C). Provided by IHSNot for ResaleNo reproduction or networking permitted without licen

19、se from IHS-,-,-DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE DWG NO. A 037Z3 10021 REV PAGE 5 RF high potential withstanding voltage: 150 V rms minimum at sea level. Frequency: 5 MHz. Leakage current: Not applicable. Cable retention: Not applicable. Coupling mechanism reten

20、tion force: Not applicable. Durability: 100 cycles. RF insertion loss: .12 Frequency (GHz) dB Part or Identifying Number (PIN): 10021 (see figure 1). 1/ Parts must be purchased to this DSCC PIN to assure that all performance requirements and tests are met. Materials: Contacts and adapter housing: Be

21、ryllium copper in accordance with ASTM B196/B196M, gold plated to a minimum thickness of 50 microinches (1.27 m) in accordance with MIL-DTL-45204, type II, grade C, class 1, over 50 microinches (1.27 m) minimum of nickel in accordance with MIL-DTL-38999, class 1. Approved sources. Approved sources o

22、f supply will be listed herein. Approved sources are required to be a QPL source on MIL-PRF-39012 or MIL-PRF-31031. Additional sources will be added as they become available. The vendors listed on the requirements drawing agree to this drawing and a certificate of compliance has been submitted to DLA Land and Maritime - VAI. Vendor CAGE Vendor Name and Number address 95077 SV Microwave, Inc. 2400 Centrepark West Drive West Palm Beach, Florida 33409-6469 DLA Land and Maritime drawing PIN 1/ 10021 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • ASTM F2072-2001(2007) Standard Practice for Hosedown of a Membrane Switch《薄膜开关软管洗涤的标准实施规程》.pdf ASTM F2072-2001(2007) Standard Practice for Hosedown of a Membrane Switch《薄膜开关软管洗涤的标准实施规程》.pdf
  • ASTM F2072-2014 Standard Test Method for Hosedown of a Membrane Switch《薄膜开关软管洗涤的标准试验方法》.pdf ASTM F2072-2014 Standard Test Method for Hosedown of a Membrane Switch《薄膜开关软管洗涤的标准试验方法》.pdf
  • ASTM F2073-2001(2006) Standard Test Method for Non-Destructive Short Circuit Testing of a Membrane Switch《薄膜开关无损短路检验的标准试验方法》.pdf ASTM F2073-2001(2006) Standard Test Method for Non-Destructive Short Circuit Testing of a Membrane Switch《薄膜开关无损短路检验的标准试验方法》.pdf
  • ASTM F2073-2014 Standard Test Method for Non-Destructive Short Circuit Testing of a Membrane Switch《薄膜开关无损短路检验的标准试验方法》.pdf ASTM F2073-2014 Standard Test Method for Non-Destructive Short Circuit Testing of a Membrane Switch《薄膜开关无损短路检验的标准试验方法》.pdf
  • ASTM F2075-2004e1 Standard Specification for Engineered Wood Fiber for Use as a Playground Safety Surface Under and Around Playground Equipment《置于运动场设备下面和周围的运动场安全表面用工程木纤维标准规范》.pdf ASTM F2075-2004e1 Standard Specification for Engineered Wood Fiber for Use as a Playground Safety Surface Under and Around Playground Equipment《置于运动场设备下面和周围的运动场安全表面用工程木纤维标准规范》.pdf
  • ASTM F2075-2010 Standard Specification for Engineered Wood Fiber for Use as a Playground Safety Surface Under and Around Playground Equipment.pdf ASTM F2075-2010 Standard Specification for Engineered Wood Fiber for Use as a Playground Safety Surface Under and Around Playground Equipment.pdf
  • ASTM F2075-2010a Standard Specification for Engineered Wood Fiber for Use as a Playground Safety Surface Under and Around Playground Equipment《置于运动场设备下方和附近的用作运动场安全表面的工程木纤维标准规范》.pdf ASTM F2075-2010a Standard Specification for Engineered Wood Fiber for Use as a Playground Safety Surface Under and Around Playground Equipment《置于运动场设备下方和附近的用作运动场安全表面的工程木纤维标准规范》.pdf
  • ASTM F2075-2015 Standard Specification for Engineered Wood Fiber for Use as a Playground Safety Surface Under and Around Playground Equipment《作为游乐场设备下方及周围游乐场安全表面使用的工程木纤维的标准规格》.pdf ASTM F2075-2015 Standard Specification for Engineered Wood Fiber for Use as a Playground Safety Surface Under and Around Playground Equipment《作为游乐场设备下方及周围游乐场安全表面使用的工程木纤维的标准规格》.pdf
  • ASTM F2076-2001(2006) Standard Practice for Communicating an EMS Patient Report to Receiving Medical Facilities《EMS病人报告关于接收医疗设备的通知的标准实施规程》.pdf ASTM F2076-2001(2006) Standard Practice for Communicating an EMS Patient Report to Receiving Medical Facilities《EMS病人报告关于接收医疗设备的通知的标准实施规程》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1