DLA DSCC-DWG-10021-2013 CONNECTOR ELECTRICAL COAXIAL RADIO FREQUENCY ADAPTER ELECTRICAL COAXIAL RF SOCKET CONTACT SERIES SMPS TO SMPS.pdf

上传人:jobexamine331 文档编号:688708 上传时间:2018-12-30 格式:PDF 页数:5 大小:56.59KB
下载 相关 举报
DLA DSCC-DWG-10021-2013 CONNECTOR ELECTRICAL COAXIAL RADIO FREQUENCY ADAPTER ELECTRICAL COAXIAL RF SOCKET CONTACT SERIES SMPS TO SMPS.pdf_第1页
第1页 / 共5页
DLA DSCC-DWG-10021-2013 CONNECTOR ELECTRICAL COAXIAL RADIO FREQUENCY ADAPTER ELECTRICAL COAXIAL RF SOCKET CONTACT SERIES SMPS TO SMPS.pdf_第2页
第2页 / 共5页
DLA DSCC-DWG-10021-2013 CONNECTOR ELECTRICAL COAXIAL RADIO FREQUENCY ADAPTER ELECTRICAL COAXIAL RF SOCKET CONTACT SERIES SMPS TO SMPS.pdf_第3页
第3页 / 共5页
DLA DSCC-DWG-10021-2013 CONNECTOR ELECTRICAL COAXIAL RADIO FREQUENCY ADAPTER ELECTRICAL COAXIAL RF SOCKET CONTACT SERIES SMPS TO SMPS.pdf_第4页
第4页 / 共5页
DLA DSCC-DWG-10021-2013 CONNECTOR ELECTRICAL COAXIAL RADIO FREQUENCY ADAPTER ELECTRICAL COAXIAL RF SOCKET CONTACT SERIES SMPS TO SMPS.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 AMSC N/A 5935-E838-003 REVISIONS LTR DESCRIPTION DATE APPROVED REV PAGE REV STATUS OF PAGES REV PAGE 1 2 3 4 5 PMIC G PREPARED BY DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OHIO 43218-3990 Jeremy Funk Original date of drawing 04 September 2013 CHECKED BY TITLE Jeremy Funk CONNECTOR, ELECTRICAL, COAX

2、IAL, RADIO FREQUENCY, ADAPTER, ELECTRICAL, COAXIAL, RF, SOCKET CONTACT, SERIES SMPS TO SMPS APPROVED BY Abdonasser Abdouni SIZE CAGE CODE DWG. NO. 10021 A 037Z3 REV PAGE 1 OF 5 CURRENT DESIGN ACTIVITY CAGE CODE 037Z3 HAS CHANGED NAMES TO: DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 Provided by I

3、HSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE DWG NO. A 037Z3 10021 REV PAGE 2 ENGINEERING DATA: Nominal impedance: 50 ohms. Frequency range: DC to 100 GHz. RF leakage: -80 dB to 3 GHz. -65

4、dB from 3 to 26.5 GHz minimum. Voltage rating: 168 V rms maximum at sea level. 33 V rms at 70,000 feet. Operating temperature: -65C to +165C. Inches mm .009 .023 .063 1.60 .068 1.73 .098 2.49 .110 2.79 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for information only. 3. All u

5、ndimensioned pictorial configurations are for reference purposes only. 4. Special tools shall be required for assembly. Contact manufacturer. FIGURE 1. General configuration, adapter. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE SUPPLY CEN

6、TER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE DWG NO. A 037Z3 10021 REV PAGE 3 REQUIREMENTS: (All electrical and mechanical requirements shall be maintained during radial misalignment. Requirements of drawing 84148 are applicable.) Dimensions and configurations: See figure 1. Interface dimens

7、ions: In accordance with MIL-STD-348. Force to engage: Full detent: 4 pounds maximum. Smooth bore: 2 pounds maximum. Force to disengage: 2 pounds minimum - full detent 0.5 pounds minimum - smooth bore Center contact inspection conditions (after heat treat) Oversize test pin: Test pin diameter: .0105

8、 inch +.0001/-.0000 inch. Insertion depth: .010 inch minimum, .020 inch maximum. Number of insertions: 1 Insertion force test: Test pin diameter: .0100 inch +.0001/-.0000 inch. Insertion force: 10 ounces, maximum. Insertion depth: .015 inch minimum, .025 inch maximum. Withdrawal force test: Test pin

9、 diameter: .0080 +0000/-.0001 inch. Withdrawal force: 0.25 ounce, minimum. Insertion depth: .015 inch minimum, .025 inch maximum. Radial misalignment: Total radial misalignment between centerlines of connector shroud or mating planes, .008 inch (0.25 mm), min. Axial misalignment: .000/.008 (0.00/0.2

10、0 mm). Coupling proof torque: Not applicable. Hermetic seal: Not applicable. Leakage (pressurized connectors): Not applicable. Center contact retention: .75 pounds minimum axial force Radial torque: Not applicable. Provided by IHSNot for ResaleNo reproduction or networking permitted without license

11、from IHS-,-,-DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE DWG NO. A 037Z3 10021 REV PAGE 4 Voltage standing wave ratio: DC to 40 gigahertz: 1.15:1 maximum. 40 to 65 gigahertz: 1.25:1 maximum. VSWR procedure. The VSWR shall be measured in accordance with the following proced

12、ure or a method acceptable to the Government. Part should be tested using a Network Analyzer with the Time Domain (TDR) option installed. This is essential to allow the effect of the adapters to be “gated” out. The recommended network analyzer systems include Hewlett Packard HP 8510. Wiltron 360 or

13、equivalent. The printer/plotter and the computer should be any unit compatible to the system. The device under test (DUT) shall consist of DSCC PIN 10021 mated at both ends with adapters capable of performing to 65 GHz . Calibration of the system should be performed using the manufacturers calibrati

14、on kits and the recommended calibration procedures. The frequency range shall be DC to 65 GHz. The VSWR calibration test setup shall be verified using the manufacturers verification kits. The calibrated system VSWR shall be less than 1.02 + .001F (F in GHZ). The VSWR of the DUT shall be measured usi

15、ng the procedures described in the manufacturers operating instructions. The time domain shall then be used to remove the effects of the test adapter. The output shall be generated using the appropriate printer/plotter. Moisture resistance: MIL-STD-202, method 106, except step 7b shall be omitted. R

16、esistance shall be 1,000 megohms within 5 minutes after removal from humidity Contact resistance (in milliohms, maximum): Initial Center contact 6.0 Outer contact 2.0 Dielectric withstanding voltage at sea level: 250 V rms minimum. 50 V rms at 70,000 feet. Vibration, high frequency: MIL-STD-202, met

17、hod 204, test condition D. Vibration, random: MIL-STD-202, method 214, test condition F, duration 15 minutes, minimum. Corona level : Altitude: 70,000 feet. 100 V rms, minimum. Insulation resistance: 3,500 megohms minimum when tested in accordance with MIL-PRF-39012 . Altitude: Sea level to 70,000 f

18、eet. Solderability (when applicable): Not applicable. Shock (specified pulse): MIL-STD-202, method 213, test condition I. Thermal shock: MIL-STD-202, method 107, test condition B (except high temperature to be +165C). Provided by IHSNot for ResaleNo reproduction or networking permitted without licen

19、se from IHS-,-,-DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE DWG NO. A 037Z3 10021 REV PAGE 5 RF high potential withstanding voltage: 150 V rms minimum at sea level. Frequency: 5 MHz. Leakage current: Not applicable. Cable retention: Not applicable. Coupling mechanism reten

20、tion force: Not applicable. Durability: 100 cycles. RF insertion loss: .12 Frequency (GHz) dB Part or Identifying Number (PIN): 10021 (see figure 1). 1/ Parts must be purchased to this DSCC PIN to assure that all performance requirements and tests are met. Materials: Contacts and adapter housing: Be

21、ryllium copper in accordance with ASTM B196/B196M, gold plated to a minimum thickness of 50 microinches (1.27 m) in accordance with MIL-DTL-45204, type II, grade C, class 1, over 50 microinches (1.27 m) minimum of nickel in accordance with MIL-DTL-38999, class 1. Approved sources. Approved sources o

22、f supply will be listed herein. Approved sources are required to be a QPL source on MIL-PRF-39012 or MIL-PRF-31031. Additional sources will be added as they become available. The vendors listed on the requirements drawing agree to this drawing and a certificate of compliance has been submitted to DLA Land and Maritime - VAI. Vendor CAGE Vendor Name and Number address 95077 SV Microwave, Inc. 2400 Centrepark West Drive West Palm Beach, Florida 33409-6469 DLA Land and Maritime drawing PIN 1/ 10021 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • DIN EN 62811-2016 AC and or DC-supplied electronic controlgear for discharge lamps (excluding fluorescent lamps) - Performance requirements for low frequency squarewave operation (.pdf DIN EN 62811-2016 AC and or DC-supplied electronic controlgear for discharge lamps (excluding fluorescent lamps) - Performance requirements for low frequency squarewave operation (.pdf
  • DIN EN 62813-2015 Lithium ion capacitors for use in electric and electronic equipment - Test methods for electrical characteristics (IEC 62813 2015) German version EN 62813 2015《用于.pdf DIN EN 62813-2015 Lithium ion capacitors for use in electric and electronic equipment - Test methods for electrical characteristics (IEC 62813 2015) German version EN 62813 2015《用于.pdf
  • DIN EN 62823-2016 Thyristor valves for thyristor controlled series capacitors (TCSC) - Electrical testing (IEC 62823 2015) German version EN 62823 2015《晶闸管控制串联电容器 (TCSC) 用晶闸管阀 电气试验.pdf DIN EN 62823-2016 Thyristor valves for thyristor controlled series capacitors (TCSC) - Electrical testing (IEC 62823 2015) German version EN 62823 2015《晶闸管控制串联电容器 (TCSC) 用晶闸管阀 电气试验.pdf
  • DIN EN 62827-1-2017 Wireless Power Transfer - Management - Part 1 Common Components (IEC 62827-1 2016) German version EN 62827-1 2016《无线能量传输 管理 第1部分 公共组件(IEC 62827-1-2016) 德文版本EN 6.pdf DIN EN 62827-1-2017 Wireless Power Transfer - Management - Part 1 Common Components (IEC 62827-1 2016) German version EN 62827-1 2016《无线能量传输 管理 第1部分 公共组件(IEC 62827-1-2016) 德文版本EN 6.pdf
  • DIN EN 62842-2016 File allocation system with minimized reallocation for multimedia home server (TA 8) (IEC 62842 2015) English version EN 62842 2015《用于多媒体家用服务器的再分配最小化文件分配系统(TA 8)(.pdf DIN EN 62842-2016 File allocation system with minimized reallocation for multimedia home server (TA 8) (IEC 62842 2015) English version EN 62842 2015《用于多媒体家用服务器的再分配最小化文件分配系统(TA 8)(.pdf
  • DIN EN 62875-2015 Multimedia systems and equipment - Multimedia e-publishing and e-book technologies - Printing specification of texture map for auditory presentation of printed te.pdf DIN EN 62875-2015 Multimedia systems and equipment - Multimedia e-publishing and e-book technologies - Printing specification of texture map for auditory presentation of printed te.pdf
  • DIN EN 62878-1-1-2016 Device embedded substrate - Part 1-1 Generic specification - Test methods (IEC 62878-1-1 2015) German version EN 62878-1-1 2015《装置嵌入基体 第1-1部分 总规格 试验方法(IEC 628.pdf DIN EN 62878-1-1-2016 Device embedded substrate - Part 1-1 Generic specification - Test methods (IEC 62878-1-1 2015) German version EN 62878-1-1 2015《装置嵌入基体 第1-1部分 总规格 试验方法(IEC 628.pdf
  • DIN EN 62889-2015 Digital video interface - Gigabit video interface for multimedia systems (IEC 62889 2015) German version EN 62889 2015《数字视频接口 多媒体系统用千兆视频接口(IEC 62889-2015) 德文版本EN .pdf DIN EN 62889-2015 Digital video interface - Gigabit video interface for multimedia systems (IEC 62889 2015) German version EN 62889 2015《数字视频接口 多媒体系统用千兆视频接口(IEC 62889-2015) 德文版本EN .pdf
  • DIN EN 62940-2017 Maritime navigation and radiocommunication equipment and systems - Integrated communication system (ICS) - Operational and performance requirements methods of tes.pdf DIN EN 62940-2017 Maritime navigation and radiocommunication equipment and systems - Integrated communication system (ICS) - Operational and performance requirements methods of tes.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1