1、 REVISIONS LTR DESCRIPTION DATE APPROVED A Added an allowance for 2-sided marking. 29 January 2013 Michael A. Radecki Prepared in accordance with ASME Y14.100 Source control drawing REV STATUS REV A A A A A A A A OF PAGES PAGES 1 2 3 4 5 6 7 8 PMIC N/A PREPARED BY John Bonitatibus DESIGN ACTIVITY DL

2、A LAND AND MARITIME COLUMBUS, OH 43218-3990 Original date of drawing 11 December 2012 CHECKED BY Mark Rush TITLE CAPACITORS, FIXED, GLASS DIELECTRIC, (AXIAL WIRE-LEAD TERMINALS) APPROVED BY Michael A. Radecki SIZE A CODE IDENT. NO. 037Z3 DWG NO. 13004 SCALE N/A REV A PAGE 1 OF 8 AMSC N/A 5910-2013-E

3、05Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DLA LAND AND MARITIME COLUMBUS, OHIO SIZE A CODE IDENT NO. 037Z3 DWG NO. 13004 REV A PAGE 2 1. SCOPE 1.1 Scope. This drawing describes the requirements for glass dielectric capacitors screened to MIL-

4、PRF-23269. The capacitors described herein are possible replacements for MIL-PRF-23269/1 capacitors (see 6.4 and table II). 1.2 Part or Identifying Number (PIN). The complete PIN shall be as follows: 13004 -001 Drawing Dash number number (see table I) 2. APPLICABLE DOCUMENTS 2.1 General. The documen

5、ts listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list,

6、 document users are cautioned that they must meet all specified requirements of documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks

7、form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-PRF-23269 - Capacitors, Fixed, Glass Dielectric, Established Reliability, General Specifica

8、tion for. (Copies of these documents are available online at https:/assist.dla.mil/quicksearch or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.3 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a

9、conflict between the text of this document and the references cited herein (except for related specification sheets), the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMEN

10、TS 3.1 Interface and physical dimensions. The interface and physical dimensions shall be as specified in MIL-PRF-23269 and herein (see figure 1). 3.1.1 Case material. Glass. 3.1.2 Terminals. Solderable. 3.1.3 Seal. Hermetic. 3.1.4 Pure tin. The use of pure tin, as an underplate or final finish is pr

11、ohibited both internally and externally. Tin content of capacitor components and solder shall not exceed 97 percent, by mass. Tin shall be alloyed with a minimum of 3 percent lead, by mass (see 6.3). 3.2 Rated temperature. -55C to +125C. Provided by IHSNot for ResaleNo reproduction or networking per

12、mitted without license from IHS-,-,-DLA LAND AND MARITIME COLUMBUS, OHIO SIZE A CODE IDENT NO. 037Z3 DWG NO. 13004 REV A PAGE 3 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. See marking requirement (see 3.8). At the option of the manufacturer, t

13、he trademark, year code, and lot code may be marked on the reverse side of the capacitor. FIGURE 1. Dimensions and configuration. 3.3 Electrical characteristics. 3.3.1 Capacitance tolerance. See table I. 3.3.2 Rated voltage. See table I. 3.3.3 Capacitance. When measured as specified in MIL-PRF-23269

14、, the capacitance shall be within the applicable tolerance of the nominal value specified in table I. 3.3.4 Dissipation factor. When measured as specified in MIL-PRF-23269, the dissipation factor shall not exceed 0.1 percent. 3.3.5 Temperature coefficient and capacitance drift (manufacturer eligibil

15、ity only (see 3.9). When measured as specified in MIL-PRF-23269, the capacitors shall meet the following requirements: a. Temperature coefficient: 140 parts per million (ppm)/C 25 ppm/C. b. Capacitance drift: 0.1 percent or 0.1 pF, whichever is greater. Inches mm Inches mm .001 0.03 .047 1.19 .004 0

16、.10 .078 1.98 .016 0.41 .172 4.37 .020 0.51 .344 8.74 .031 0.79 1.125 28.58 13004 -001 TM 12A Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DLA LAND AND MARITIME COLUMBUS, OHIO SIZE A CODE IDENT NO. 037Z3 DWG NO. 13004 REV A PAGE 4 3.3.6 Insulation

17、 resistance (IR). When measured as specified in MIL-PRF-23269, the insulation resistance shall be 100,000 megohms, minimum, at +25C. 3.3.7 Quality factor (Q) (manufacturer eligibility only (see 3.9). In accordance with MIL-PRF-23269. 3.4 Seal. In accordance with MIL-PRF-23269, test I. 3.5 Thermal sh

18、ock (manufacturer eligibility group C only (see 3.9). In accordance with MIL-PRF-23269. The following detail shall apply: Dissipation factor: 0.1 percent maximum. 3.6 Moisture resistance (manufacturer eligibility only (see 3.9). In accordance with MIL-PRF-23269. The following detail shall apply: Dis

19、sipation factor: 0.1 percent maximum. 3.7 Life (manufacturer eligibility only (see 3.9). In accordance with MIL-PRF-23269. The following details shall apply: a. Capacitance (240 hours and 2,000 hours): 0.5 percent or 0.5 pF maximum. b. Dissipation factor (240 hours and 2,000 hours): 0.15 percent max

20、imum. 3.8 Marking. In accordance with MIL-PRF-23269, except the capacitor shall be marked with the PIN as specified herein (see 1.2. 13004 DLA Land and Maritime drawing number -001 Non-significant dash number TM 12A | Trademark Year Sequential 4 week lot code code 3.9 Manufacturer eligibility. To be

21、 eligible for listing as an approved source of supply, a manufacturer shall be listed on the MIL-PRF-23269 Qualified Products Database for at least one part, or perform the group A and group C inspections specified herein on a sample of parts agreed upon by the manufacturer and DLA Land and Maritime

22、-VA. 3.10 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent possible provided that the material meets or exceeds the operational and maintenance requirements, and promotes economically advan

23、tageous life cycle costs. 3.11 Certificate of compliance. A certificate of compliance shall be required from manufacturers requesting to be an approved source of supply. 3.12 Workmanship. The capacitor shall be uniform in quality and free from any defects that will affect life, serviceability, or ap

24、pearance. 4. VERIFICATION 4.1 Qualification inspection. Qualification inspection is not required. 4.2 Conformance inspection. 4.2.1 Inspection of product for delivery. Inspection of product for delivery shall consist of the group A inspection of MIL-PRF-23269. 5. PACKAGING 5.1 Packaging. For acquisi

25、tion purposes, the packaging requirements shall be as specified in the contract or order (see 6.2). When packaging of materiel is to be performed by DoD or in-house contractor personnel, these personnel need to contact the responsible packaging activity to ascertain packaging requirements. Packaging

26、 requirements are maintained by the Inventory Control Points packaging activities within the Military Service or Defense Agency, or within the military services system commands. Packaging data retrieval is available from the managing Military Departments or Defense Agencys automated packaging files,

27、 CD-ROM products, or by contacting the responsible packaging activity. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DLA LAND AND MARITIME COLUMBUS, OHIO SIZE A CODE IDENT NO. 037Z3 DWG NO. 13004 REV A PAGE 5 TABLE I. Electrical characteristics. DL

28、A Land and Maritime drawing (PIN) 13004- Capacitance (pF) Capacitance tolerance 500 Vdc 100 Vdc 001 201 0.5 0.25 pF 002 202 1.0 0.25 pF 003 203 1.5 0.25 pF 004 204 2.2 0.25 pF 005 205 2.2 0.50 pF 006 206 2.7 0.25 pF 007 207 3.0 0.25 pF 008 208 3.0 0.50 pF 009 209 3.3 0.25 pF 010 210 3.6 0.25 pF 011

29、211 3.6 0.50 pF 012 212 3.9 0.25 pF 013 213 4.3 0.25 pF 014 214 4.3 0.50 pF 015 215 4.7 0.25 pF 016 216 5.1 0.25 pF 017 217 5.6 0.25 pF 018 218 5.6 5% 019 219 6.2 0.25 pF 020 220 6.2 5% 021 221 6.8 0.25 pF 022 222 6.8 5% 023 223 7.5 0.25 pF 024 224 7.5 5% 025 225 8.2 0.25 pF 026 226 8.2 5% 027 227 9

30、.1 0.25 pF 028 228 9.1 5% 029 229 10 0.25 pF 030 230 10 5% 031 231 11 0.25 pF 032 232 11 5% 033 233 12 0.25 pF 034 234 12 5% 035 235 13 2% 036 236 13 5% 037 237 15 2% 038 238 15 5% 039 239 16 2% 040 240 16 5% 041 241 18 2% 042 242 18 5% 043 243 20 2% 044 244 20 5% 045 245 22 2% 046 246 22 5% 047 247

31、 24 2% 048 248 24 5% Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DLA LAND AND MARITIME COLUMBUS, OHIO SIZE A CODE IDENT NO. 037Z3 DWG NO. 13004 REV A PAGE 6 TABLE I. Electrical characteristics. Continued. DLA Land and Maritime drawing (PIN) 13004

32、- Capacitance (pF) Capacitance tolerance 500 Vdc 100 Vdc 049 249 27 1% 050 250 27 2% 051 251 27 5% 052 252 30 1% 053 253 30 2% 054 254 30 5% 055 255 33 1% 056 256 33 2% 057 257 33 5% 058 258 36 1% 059 259 36 2% 060 260 36 5% 061 261 39 1% 062 262 39 2% 063 263 39 5% 064 264 43 1% 065 265 43 2% 066 2

33、66 43 5% 067 267 47 1% 068 268 47 2% 069 269 47 5% 070 270 51 1% 071 271 51 2% 072 272 51 5% 073 273 56 1% 074 274 56 2% 075 275 56 5% 076 276 62 1% 077 277 62 2% 078 278 62 5% 079 279 68 1% 080 280 68 2% 081 281 68 5% 082 282 75 1% 083 283 75 2% 084 284 75 5% 085 285 82 1% 086 286 82 2% 087 287 82

34、5% 088 288 91 1% 089 289 91 2% 090 290 91 5% 091 291 100 1% 092 292 100 2% 093 293 100 5% 094 294 110 1% 095 295 110 2% 096 296 110 5% Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DLA LAND AND MARITIME COLUMBUS, OHIO SIZE A CODE IDENT NO. 037Z3 DW

35、G NO. 13004 REV A PAGE 7 TABLE I. Electrical characteristics. Continued. DLA Land and Maritime drawing (PIN) 13004- Capacitance (pF) Capacitance tolerance 500 Vdc 100 Vdc 097 297 120 1% 098 298 120 2% 099 299 120 5% 100 300 130 1% 101 301 130 2% 102 302 130 5% 103 303 150 1% 104 304 150 2% 105 305 1

36、50 5% 106 306 160 1% 107 307 160 2% 108 308 160 5% 109 309 180 1% 110 310 180 2% 111 311 180 5% 112 312 200 1% 113 313 200 2% 114 314 200 5% 300 Vdc 100 Vdc 115 315 220 1% 116 316 220 2% 117 317 220 5% 118 318 240 1% 119 319 240 2% 120 320 240 5% 121 321 270 1% 122 322 270 2% 123 323 270 5% 124 324

37、300 1% 125 325 300 2% 126 326 300 5% 6. NOTES (This section contains information of a general or explanatory nature which may be helpful, but is not mandatory.) 6.1 Intended use. Capacitors conforming to this drawing are intended for use when military specifications do not exist and qualified milita

38、ry devices that will perform the required function are not available for OEM application. This drawing is intended exclusively to prevent the proliferation of unnecessary duplicate specifications, drawings, and stock catalog listings. When a military specification exists and the product covered by t

39、his drawing has been qualified for listing, this drawing becomes obsolete and will not be used for new design. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DLA LAND AND MARITIME COLUMBUS, OHIO SIZE A CODE IDENT NO. 037Z3 DWG NO. 13004 REV A PAGE 8

40、 6.2 Ordering data. The contract or purchase order should specify the following: a. Complete PIN (see 1.2). b. Requirements for delivery of one copy of the conformance inspection data or certificate of compliance that parts have passed conformance inspection with each shipment of parts by the manufa

41、cturer. c. Requirements for notification of change of product to the acquiring activity, if applicable. d. Requirements for packaging and packing. 6.3 Tin whisker growth. The use of alloys with tin content greater than 97 percent, by mass, may exhibit tin whisker growth problems after manufacture. T

42、in whiskers may occur anytime from a day to years after manufacture and can develop under typical operating conditions, on products that use such materials. Conformal coatings applied over top of a whisker-prone surface will not prevent the formation of tin whiskers. Alloys of 3 percent lead, by mas

43、s, have shown to inhibit the growth of tin whiskers. For additional information on this matter, refer to ASTM-B545 (Standard Specification for Electrodeposited Coatings of Tin). 6.4 MIL-PRF-23269/1 replacements. The capacitors described herein are possible replacements for MIL-PRF-23269/1 capacitors

44、. Users are cautioned to evaluate this document for their particular application before citing it as a replacement document. MIL-PRF-23269/1 capacitors have failure rate levels (FRL) established in accordance with MIL-STD-690. DLA Land and Maritime drawing 13004 capacitors are non-established reliab

45、ility. TABLE II. Replacement data. MIL-PRF-23269/1 PIN DLA Land and Maritime drawing PIN 13004- -001 through -126 1/ 001 through 126 7001 through 7126 201 through 326 1/ The complete MIL-PRF-23269/1 PIN shall include an additional character to indicate the FRL (3, 4, 5, or 6). 6.5 Replaceability. Ca

46、pacitors covered by this drawing will replace the same commercial device covered by contractor prepared specification or drawing. 6.6 Changes from previous issue. The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes