1、AMSC N/A FSC 6240 INCH-POUND MIL-DTL-15098/12C 23 August 2010 SUPERSEDING MIL-L-15098/12B 16 December 1977 DETAIL SPECIFICATION SHEET LAMP, GLOW, INDICATOR, TYPE R1A This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring th

2、e product described herein shall consist of this specification sheet and MIL-DTL-15098, “Lamps, Glow, General Specification for“. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-15098/12C 2 NOTES: 1. Dimensions are in inches. 2. Metric equiva

3、lents are given for general information only and are based upon 1 inch = 25.4 mm. FIGURE 1. Indicator glow lamp, type R1A. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-15098/12C 3 REQUIREMENTS: Design and configuration: See figure 1 and ta

4、ble I. Vibration: Not applicable. Shock: Method II of MIL-DTL-15098. Part number: M15078/12 - 001. TABLE I. Characteristics and specifications. Characteristic Specification Bulb shape and size S7 Maximum overall length (inch) 2 Base DCB Electrode shape PW5 Distance from end of electrode to end of bu

5、lb (inches, nominal) 0.312 Series resistor Ohms 7,500 Location External Characteristic gas Neon Glow color Red Watts (nominal) 1 Application Indicator Nominal circuit voltage (volts) 120 AC Maximum initial starting voltage (volts) In light 65 AC, 90 DC Design current (milliamperes) 8 Initial light o

6、utput (lumens) 0.30 Average life at design current (hours) 10,000 Industry number ANSI R1A Former lamp number NE-79 CHANGES FROM PREVIOUS ISSUE. Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of the changes. Provided by IHSNo

7、t for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-15098/12C 4 Custodians: Preparing Activity: Army - CR Navy - SH Air Force - 99 DLA - GS DLA - GS2 (Project 6240-2010-014) Review Activities: Army - AR, CR4, MI Navy - AS, CG, MC Air Force - 71 DLA - IS NOTE: The

8、 activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST database at https:/assist.daps.dla.mil/. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-