DLA MIL-DTL-49285 15 A-2010 CABLE SPECIAL PURPOSE ELECTRICAL TWENTY-SEVEN INDIVIDUALLY SHIELDED PAIRS OF 22 (7 X 30) AWG.pdf

上传人:boatfragile160 文档编号:690833 上传时间:2018-12-30 格式:PDF 页数:5 大小:79.93KB
下载 相关 举报
DLA MIL-DTL-49285 15 A-2010 CABLE SPECIAL PURPOSE ELECTRICAL TWENTY-SEVEN INDIVIDUALLY SHIELDED PAIRS OF 22 (7 X 30) AWG.pdf_第1页
第1页 / 共5页
DLA MIL-DTL-49285 15 A-2010 CABLE SPECIAL PURPOSE ELECTRICAL TWENTY-SEVEN INDIVIDUALLY SHIELDED PAIRS OF 22 (7 X 30) AWG.pdf_第2页
第2页 / 共5页
DLA MIL-DTL-49285 15 A-2010 CABLE SPECIAL PURPOSE ELECTRICAL TWENTY-SEVEN INDIVIDUALLY SHIELDED PAIRS OF 22 (7 X 30) AWG.pdf_第3页
第3页 / 共5页
DLA MIL-DTL-49285 15 A-2010 CABLE SPECIAL PURPOSE ELECTRICAL TWENTY-SEVEN INDIVIDUALLY SHIELDED PAIRS OF 22 (7 X 30) AWG.pdf_第4页
第4页 / 共5页
DLA MIL-DTL-49285 15 A-2010 CABLE SPECIAL PURPOSE ELECTRICAL TWENTY-SEVEN INDIVIDUALLY SHIELDED PAIRS OF 22 (7 X 30) AWG.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 MIL-DTL-49285/15A 31 March 2010 SUPERSEDING MIL-C-49285/15 19 October 1989 DETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL, TWENTY-SEVEN INDIVIDUALLY SHIELDED PAIRS OF 22 (7 X 30) AWG This specification is approved for use by all Departments and Agencies of the Department of Defense.

2、The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-49285. FIGURE 1. Cable illustration. AMSC N/A FSC 6145 INCH-POUND Inactive for new design after 16 June 1997. Provided by IHSNot for ResaleNo reproduction or networking permitted without

3、 license from IHS-,-,-MIL-DTL-49285/15A 2 Engineering information: See table I. Note: Not for aerospace use. TABLE I. Description, electrical. Electrical characteristics Requirements Nominal capacitance between conductors Nominal capacitance between the conductor and the shield with one conductor ti

4、ed to the shield Continuous working voltage Nominal capacitance between adjacent shields Continuous working voltage between adjacent shields Shield dc resistance 30 pF/ft (picofarads/foot) 55 pF/ft 300 V rms maximum between conductors 150 pF/ft 50 volts maximum 14 ohms/1,000 feet maximum TABLE II. D

5、escription, physical. Components Construction details Number of pairs Conductor type and wire size Conductor stranding Conductor insulation Conductor insulation thickness Drain wire type and size Drain wire stranding Jacket material Jacket thickness Finished cable diameter Cable style (UL) Tensile s

6、trength (jacket) Elongation (jacket) Overall cabling lay length Twenty-seven individually shielded Stranded tinned copper 22 AWG 7 X 30 AWG Polypropylene 0.010 inch nominal thickness Stranded tinned copper 22 AWG 16 X 34 AWG Polyvinyl chloride 0.050 inch 0.783 inch maximum outside diameter 2493 2,00

7、0 pounds per square inch minimum 150 percent minimum 1.3 twists per foot 10 percent Cabled pair orientation: The position of the red and green pair shield shall determine the rotation direction for pair location (see figure 1). Provided by IHSNot for ResaleNo reproduction or networking permitted wit

8、hout license from IHS-,-,-MIL-DTL-49285/15A 3 TABLE III. Shield color code. Pair numbers Shield color Center core 1stpair 2ndpair 3rdpair Outer layer 4thpair 5thpair 6thpair 7thpair 8thpair 9thpair 10thpair 11thpair 12thpair 13thpair 14thpair 15thpair 16thpair 17thpair 18thpair 19thpair 20thpair 21t

9、h pair 22th pair 23th pair 24thpair 25thpair 26thpair 27thpair Red Green Blue 1 Red Green Blue 1 Blue 2 Blue 3 Blue 4 Blue 5 Blue 6 Blue 7 Red Green Blue 1 Blue 2 Blue 3 Blue 4 Blue 5 Blue 6 Blue 7 Blue 8 Blue 9 Blue 10 Blue 11 Blue 12 Blue - 13 REQUIREMENTS: Design and construction: See tables II a

10、nd III: Shield location and orientation. The polyester aluminum shield is to be located on the outer circumference of the pair, with the aluminum foil side outward. Insulation on the interior of the shield is to be complete with no aluminum available for contact. Drain wire location. The drain wire

11、is to be spirally located between the noise reducing tape and the aluminum foil shield, and is to be in continuous contact with the aluminum surface of the foil shield and the noise reducing tape throughout the cable. Cable temperature rating. The cable temperature rating shall be -20C to +80C. Flam

12、mability. The cable shall pass UL 2556 flame test requirements. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-49285/15A 4 Shield integrity test.* Frequency Response * 100 kHz 115 dB below reference 500 kHz 107 dB below reference 1 MHz 101 d

13、B below reference 5 MHz 87 dB below reference 10 MHz 81 dB below reference 15 MHz 77 dB below reference 20 MHz 73 dB below reference 25 MHz 69 dB below reference 30 MHz 65 dB below reference 100 MHz 45 dB below reference * Any two readings may deviate to a value of 0.9 times the stated limits. * All

14、 values are a minimum numerical value. Fixture resonance will occur between 40 and 70 MHz. Crosstalk test limits. All values are minimums. Frequency (kHz) Near end crosstalk (dB) Far end crosstalk (dB) 40 57 57 70 54 53 100 52 51 1,000 53 51 Insulation resistance between shields: 100 megohms/1,000 f

15、eet minimum. Durometer hardness. The cable jacket shall have a “Shore A” hardness of 82 5. Part or Identifying Number (PIN): The PIN shall be M49285/15. Changes from previous issue. The margins of this specification are marked with vertical lines to indicate where changes from the previous issue wer

16、e made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relations

17、hip to the last previous issue. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-49285/15A 5 Referenced documents. This document references MIL-DTL-49285 and UL 2556. CONCLUDING MATERIAL Custodians: Preparing activity: Army CR DLA - CC Navy SH

18、 Air Force 85 DLA - CC Review activities: Army MI (Project 6145-2009-019) Air Force 99 DLA IS NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change. You should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • DIN EN 6049-003-2010 Aerospace series - Electrical cables installation - Protection sleeve in meta-aramid fibres - Part 003 Braided tubular expandable - Product standard German and.pdf DIN EN 6049-003-2010 Aerospace series - Electrical cables installation - Protection sleeve in meta-aramid fibres - Part 003 Braided tubular expandable - Product standard German and.pdf
  • DIN EN 6049-005-2015 Aerospace series - Electrical cables installation - Protection sleeve in meta-aramid fibres - Part 005 Sleeve flexible post installation - Product standard Ger.pdf DIN EN 6049-005-2015 Aerospace series - Electrical cables installation - Protection sleeve in meta-aramid fibres - Part 005 Sleeve flexible post installation - Product standard Ger.pdf
  • DIN EN 6049-006-2012 en 4930 Aerospace series - Electrical cables installation - Protection sleeve in meta-aramid fibres - Part 006 Self-wrapping protective sleeve flexible post in.pdf DIN EN 6049-006-2012 en 4930 Aerospace series - Electrical cables installation - Protection sleeve in meta-aramid fibres - Part 006 Self-wrapping protective sleeve flexible post in.pdf
  • DIN EN 6049-007-2012 en 2951 Aerospace series - Electrical cables installation - Protection sleeve in meta-aramid fibres - Part 007 Self-wrapping protective sleeve flexible post in.pdf DIN EN 6049-007-2012 en 2951 Aerospace series - Electrical cables installation - Protection sleeve in meta-aramid fibres - Part 007 Self-wrapping protective sleeve flexible post in.pdf
  • DIN EN 6049-009-2016 Aerospace series - Electrical cables installation - Protection sleeve in meta-aramid fibres - Part 009 Self-wrapping fire protection sleeve flexible post insta.pdf DIN EN 6049-009-2016 Aerospace series - Electrical cables installation - Protection sleeve in meta-aramid fibres - Part 009 Self-wrapping fire protection sleeve flexible post insta.pdf
  • DIN EN 6059-100-2015 Aerospace series - Electrical cables installation - Protection sleeves - Test methods - Part 100 General German and English version EN 6059-100 2015《航空航天系列 电缆安.pdf DIN EN 6059-100-2015 Aerospace series - Electrical cables installation - Protection sleeves - Test methods - Part 100 General German and English version EN 6059-100 2015《航空航天系列 电缆安.pdf
  • DIN EN 6059-202-2017 Aerospace series - Electrical cables installation - Protection sleeves - Test methods - Part 202 Dimensions and mass German and English version EN 6059-202 201.pdf DIN EN 6059-202-2017 Aerospace series - Electrical cables installation - Protection sleeves - Test methods - Part 202 Dimensions and mass German and English version EN 6059-202 201.pdf
  • DIN EN 6059-301-2017 Aerospace series - Electrical cables installation - Protection sleeves - Test methods - Part 301 Sun light exposure German and English version EN 6059-301 2017.pdf DIN EN 6059-301-2017 Aerospace series - Electrical cables installation - Protection sleeves - Test methods - Part 301 Sun light exposure German and English version EN 6059-301 2017.pdf
  • DIN EN 6059-302-2017 Aerospace series - Electrical cables installation - Protection sleeves - Test methods - Part 302 High temperature exposure German and English version EN 6059-3.pdf DIN EN 6059-302-2017 Aerospace series - Electrical cables installation - Protection sleeves - Test methods - Part 302 High temperature exposure German and English version EN 6059-3.pdf