1、AMSC N/A FSC 6625 PERFORMANCE SPECIFICATION SHEET METERS, ELECTRICAL INDICATING, PANEL TYPE, RUGGEDIZED: VOLTMETER, DC (SQUARE FLANGE, 1.5 INCH), STYLE 13 This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the products
2、described herein shall consist of this specification sheet and MIL-PRF-10304. FIGURE 1. Meter, panel type. INCH-POUND MIL-PRF-10304/21G w/AMENDMENT 2 28 August 2013 SUPERSEDING MIL-PRF-10304/21G w/AMENDMENT 1 18 January 2008 Provided by IHSNot for ResaleNo reproduction or networking permitted withou
3、t license from IHS-,-,-MIL-PRF-10304/21G w/AMENDMENT 2 2 Inches mm Inches mm Inches mm Inches mm .003 .08 .016 .41 .500 12.70 1.312 33.32 .005 .13 .125 3.18 .640 16.26 1.510 38.35 .006 .15 .1875 4.76 .656 16.70 1.546 39.28 .0150 .38 .250 6.35 1.000 25.40 1.81 45.97 .375 9.53 1.250 31.75 NOTES: 1. Di
4、mensions are in inches. 2. Metric equivalents are given for general information only. 3. Tolerances are .005 inch (.13 mm). 4. The center line of the terminals may be located .188 (4.78 mm) above or below the center line of the meter. 5. Letters and numerals for scale numerals and captions shall be
5、.085 (2.16 mm) max and all others shall be .050 (1.27 mm) max. 6. Other forms of terminals, as specified in MIL-PRF-10304, are permitted. The specified minimum length applies to stud-type terminals only. Terminals shall be equally spaced, from each side of vertical centerline. FIGURE 1. Meter, panel
6、 type - Continued. REQUIREMENTS: Dimensions and configuration: See figure 1. Weight: 4 ounces maximum. Full-scale ranges: See table I. Scale: Length: 1 inch minimum. Pointer deflection: 90 degrees nominal. Position influence: 3 percent maximum change for 60 degrees rotation from normal operating pos
7、ition. Accuracy: 3 percent. Overshoot: 50 percent maximum. Response time: 2 seconds maximum. Power consumption (loss) (at end scale deflection): 1 mA 5 percent. High temperature cycling: 5 percent. 3 percent permanent change. Temperature influence: 0.75 percent change. Exposure to extreme temperatur
8、es: 3 percent permanent change. Overload capacity: Sustained overload: 1 percent temporary zero shift. 1 percent permanent zero shift. 2 percent permanent change. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-10304/21G w/AMENDMENT 2 3 Diele
9、ctric withstanding voltage: 1,500 volts rms. TABLE I. Full-scale ranges. Millivolts Volts Zero left Zero left Zero center 30 2 30-0-30 50 10 50-0-50 100 20 100-0-100 200 30 300 50 500 100 200 300 Amendment notations. The margins of this specification are marked with vertical lines to indicate modifi
10、cations generated by this amendment. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the mar
11、ginal notations. Referenced documents: This document references MIL-PRF-10304. CONCLUDING MATERIAL Custodians: Preparing activity: Army - CR DLA - CC Navy - SH Air Force - 99 (Project 6625-2013-013) DLA - CC Review activities: Army - AR, AT, AV, CR4, MI Navy MC NOTE: The activities listed above were
12、 interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-