1、AMSC N/A FSC 5920 INCH-POUND MIL-PRF-15160/40C 15 October 2008 SUPERSEDING MIL-PRF-15160/40B 17 August 2006 PERFORMANCE SPECIFICATION SHEET FUSES, STYLE F40 This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product
2、 described herein shall consist of this specification sheet and MIL-PRF-15160. NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerances are .005 (0.13 mm) for three place decimals and .02 (0.5 mm) for two place decima
3、ls. FIGURE 1. Style F40. INACTIVE FOR NEW DESIGN AFTER 27 DECEMBER 1990 Inches mm .005 0.13 .031 0.78 .038 1.19 .265 6.73 .812 20.62 1.00 25.4 1.312 33.32 1.625 41.28 1.750 44.45 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-15160/40C 2 REQ
4、UIREMENTS: Interface and physical dimensions: See figure 1. Case material: Fiber or black paper. Ferrule material: Brass. Lug material: Brass. Terminal strength (ferrules): 5 inch-pound torque. Electrical: Current rating: See table I. Voltage rating: See table I. Characteristic: See table I and tabl
5、e II. Type designation: Type designation shall be as specified in table I. TABLE I. Type designation. Overload interrupt: See table II. Short circuit interrupt: 10,000 A at rated voltage dc. Insulation resistance: 0.1 megohm minimum. Style Characteristic Voltage Current F40 A 32V 40A F40 A 32V 50A F
6、40 A 32V 60A F40 A 32V 70A F40 A 32V 75A F40 A 32V 80A F40 A 32V 100A F40 A 32V 125A F40 A 32V 150A F40 B 32V 40A F40 B 32V 50A F40 B 32V 60A F40 B 32V 70A F40 B 32V 75A F40 B 32V 80A F40 B 32V 100A F40 B 32V 125A F40 B 32V 150A Provided by IHSNot for ResaleNo reproduction or networking permitted wi
7、thout license from IHS-,-,-MIL-PRF-15160/40C 3 TABLE II. Overload interrupt. 1/ The overload interrupt test at 135 percent shall be performed at 32 volts or less. VERIFICATION: Qualification inspection is not applicable for 40A, 50A, 75A, 100A, 125A, and 150A characteristic A fuses and all character
8、istic B fuses of this specification sheet (see table l) and shall be replaced by acceptance testing consisting of Group A and Group B inspections per MIL-PRF-15160, prior to delivery. Qualification inspection (Characteristic A only): The number of qualification samples required shall be: a. 24 sampl
9、es maximum current rating of each voltage and design. b. 24 samples minimum current rating of each voltage and design. The margins of this specification sheet are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Gover
10、nment assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. Percent nominal Current r
11、ange Characteristic rating A B 1/ 135 40 A to 60 A 0 to 1 hour 0 to 1 hour 70 A to 150 A 0 to 2 hours 0 to 2 hours 300 All ratings N/A 15 seconds minimum Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-15160/40C 4 Custodians: Preparing activi
12、ty: Army - CR DLA - CC Navy - SH Air Force - 85 (5920-2008-041) Review activities: Air Force - 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-