DLA MIL-PRF-28750 9 F-2013 RELAY SOLID-STATE HERMETICALLY SEALED CLASS II OPTICALLY ISOLATED ZERO VOLTAGE TURN-ON 1 AMPERE (2 AMPERES WITH HEAT SINK) 400 HZ POWER SWITCHING SPST (N.pdf

上传人:吴艺期 文档编号:692800 上传时间:2018-12-30 格式:PDF 页数:6 大小:69.42KB
下载 相关 举报
DLA MIL-PRF-28750 9 F-2013 RELAY SOLID-STATE HERMETICALLY SEALED CLASS II OPTICALLY ISOLATED ZERO VOLTAGE TURN-ON 1 AMPERE (2 AMPERES WITH HEAT SINK) 400 HZ POWER SWITCHING SPST (N.pdf_第1页
第1页 / 共6页
DLA MIL-PRF-28750 9 F-2013 RELAY SOLID-STATE HERMETICALLY SEALED CLASS II OPTICALLY ISOLATED ZERO VOLTAGE TURN-ON 1 AMPERE (2 AMPERES WITH HEAT SINK) 400 HZ POWER SWITCHING SPST (N.pdf_第2页
第2页 / 共6页
DLA MIL-PRF-28750 9 F-2013 RELAY SOLID-STATE HERMETICALLY SEALED CLASS II OPTICALLY ISOLATED ZERO VOLTAGE TURN-ON 1 AMPERE (2 AMPERES WITH HEAT SINK) 400 HZ POWER SWITCHING SPST (N.pdf_第3页
第3页 / 共6页
DLA MIL-PRF-28750 9 F-2013 RELAY SOLID-STATE HERMETICALLY SEALED CLASS II OPTICALLY ISOLATED ZERO VOLTAGE TURN-ON 1 AMPERE (2 AMPERES WITH HEAT SINK) 400 HZ POWER SWITCHING SPST (N.pdf_第4页
第4页 / 共6页
DLA MIL-PRF-28750 9 F-2013 RELAY SOLID-STATE HERMETICALLY SEALED CLASS II OPTICALLY ISOLATED ZERO VOLTAGE TURN-ON 1 AMPERE (2 AMPERES WITH HEAT SINK) 400 HZ POWER SWITCHING SPST (N.pdf_第5页
第5页 / 共6页
点击查看更多>>
资源描述

1、INCH-POUND MIL-PRF-28750/9F 16 January 2013 SUPERSEDING MIL-PRF-28750/9E 19 August 2009 PERFORMANCE SPECIFICATION SHEET RELAY, SOLID-STATE, HERMETICALLY SEALED, CLASS II, OPTICALLY ISOLATED, ZERO VOLTAGE TURN-ON, 1 AMPERE (2 AMPERES WITH HEAT SINK), 400 HZ, POWER SWITCHING, SPST (N.O.) This specific

2、ation is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the relay described herein shall consist of this specification sheet and MIL-PRF-28750. FIGURE 1. Outline drawing and dimensions. AMSC N/A FSC 5945 Provided by IHSNot for ResaleNo r

3、eproduction or networking permitted without license from IHS-,-,-MIL-PRF-28750/9F 2 NOTES: 1. Dimensions are in inches. 2. Metric equivalents given for general information only. 3. Unless otherwise specified, tolerance is .010 (0.25 mm). 4. Terminal numbers shown above are for reference only. FIGURE

4、 1. Outline drawing and dimensions - Continued. Ltr Inches mm Min Max Min Max A - .890 - 22.61 B - .530 - 13.46 C .820 .840 20.83 21.34 D - .190 - 4.83 E .250 .290 6.35 7.37 F .125 .145 3.18 3.68 G .490 .510 12.45 12.95 H .095 .115 2.41 2.92 J .290 .310 7.37 7.87 K .590 .610 14.99 15.49 L - .020 - 0

5、51 M .016 .020 0.41 0.51 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-28750/9F 3 FIGURE 2. Maximum load current versus. case temperature. FIGURE 3. Maximum load current versus. ambient temperature. Provided by IHSNot for ResaleNo reproduc

6、tion or networking permitted without license from IHS-,-,-MIL-PRF-28750/9F 4 FIGURE 4. Peak surge current versus. surge current duration. *-FIGURE 5. Broadband conducted emissions. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-28750/9F 5 RE

7、QUIREMENTS: INPUT REQUIREMENTS: Input voltage range: 3.8 V dc to 32 V dc. Assured turn-on voltage: 3.8 V dc. Assured turn-off voltage: 1.5 V dc. Input current: 18 mA dc maximum. Turn-on time: cycle ac Hz. Turn-off time: 1 cycle ac Hz. Bias voltage: Not applicable. OUTPUT REQUIREMENTS: Rated output c

8、urrent: See figure 2 and figure 3. Rated output voltage: 250 V ac rms maximum, 400 Hz. Output voltage drop: 1.5 V ac maximum. Output leakage current: 3 mA rms maximum. Crosstalk: Not applicable. Transient voltage: Step line voltage from 230 V ac, 400 Hz to 360 V ac, 400 Hz. For 5 seconds maximum. (R

9、elay can be externally protected to meet the requirements of MIL-STD-704, category B). Electrical system spike: Not applicable. Overload: 1.5 times the rated current (no heat sink), 10 percent duty cycle (see figure 4). DC offset voltage: 100 millivolts maximum. Waveform distortion: 4 V rms maximum,

10、 initial turn-on: 10 V peak maximum. Minimum current: Applicable (load current shall be varied between 10 percent and 100 percent of rated load). ELECTRICAL REQUIREMENTS: Dielectric withstanding voltage: 1,500 V ac rms, 60 Hz. Insulation resistance: 100 megohms minimum. Isolation: 10 picofarads maxi

11、mum. Power dissipation: 2.00 watts maximum (no heat sink). Exponential rate of voltage rise (dv/dt): 100 V/s. ENVIRONMENTAL REQUIREMENTS: Temperature: Operating: -55C to +110C. Storage: -55C to +125C. Thermal shock: Applicable. Provided by IHSNot for ResaleNo reproduction or networking permitted wit

12、hout license from IHS-,-,-MIL-PRF-28750/9F 6 Shock (specified pulse): MIL-STD-202, method 213, test condition F (1,500 gs). Vibration: 20 gs, 10 Hz to 2,000 Hz. Moisture resistance: Not applicable. Electromagnetic interference: Maximum broadband conducted emission on power lines with 115 V ac, 400 H

13、z, 1.0 ampere resistive load during steady state and switching conditions (see figure 5). Resistance to soldering heat: Applicable. Salt atmosphere (corrosion): In accordance with MIL-STD-750, method 1041. PHYSICAL REQUIREMENTS: Weight: 6 grams maximum. Dimensions and configuration: See figure 1. Te

14、rminal strength: 1 pound pull minimum. Terminal solderability: Applicable. Terminal finish: Corrosion resistant material. Corrosion resistant material such as gold plating are considered acceptable. Seal: Hermetic (solder or weld). Minimum marking: Part number, functional diagram and terminal identi

15、fication, date code, and manufacturers name or source code. Referenced documents. In addition to MIL-PRF-28750, this document references the following: MIL-STD-202 MIL-STD-704 MIL-STD-750 Changes from previous issue: The margins of this specification are mark with vertical lines to indicate where ch

16、anges from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and on contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of

17、the marginal notations and relationship to the last previous issue. Custodian: Preparing activity: Navy - EC DLA - CC Air Force - 85 DLA CC (Project 5945-2013-004) NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf
  • BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf
  • BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf
  • BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf
  • BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf
  • BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf
  • BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf
  • BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf
  • BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1