1、INCH-POUND MIL-PRF-39012/76D 16 November 2011 SUPERSEDING MIL-PRF-39012/76C 18 January 2007 PERFORMANCE SPECIFICATION SHEET CONNECTORS, RECEPTACLES, ELECTRICAL, COAXIAL, RADIO FREQUENCY, SERIES SMC (CABLED, PIN CONTACT, JAMNUT MOUNTED, REAR MOUNTED, CLASS 2) This specification is approved for use by
2、 all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-PRF-39012. FIGURE 1. General configuration. AMSC N/A FSC 5935 Provided by IHSNot for ResaleNo reproduction or networking permitted
3、 without license from IHS-,-,-MIL-PRF-39012/76D 2 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for information only. 3. For dimension A, see table I. 4. Dimension A defines the overall length of the connector when assembled to the cable. 5. Wrench flats are to accommodate stan
4、dard wrench opening in accordance with FED-STD-H28, appendix 10. 6. Maximum overall diameter of the connector is .320 inch (8.13 mm). 7. All undimensioned pictorial configurations are for reference purposes only. 8. Series SMC, pin contact interface in accordance with MIL-STD-348. FIGURE 1. General
5、configuration Continued. TABLE I. Dash numbers, cross-reference, and dimensions. Dash No. M39012/76 # Applicable cable group from MIL-PRF-39012, appendix B M17/ Typical mating Connector 1/ Dimensions Inches (millimeters) Maximum 2/ CATEGORY A FIELD SERVICEABLE (NO SPECIAL TOOLS REQUIRED) 0003 3/ 4/
6、Cable group I 93-RG178 * 169-00001 % M39012/73-0003 M39012/75-0003 A .88 (22.35) 0004 3/ 4/ Cable group II 113-RG316 * 172-00001 % 94-RG179 M39012/73-0004 M39012/75-0004 0103 3/ Cable group I 93-RG178 * 169-00001 % M39012/73-0103 M39012/75-0103 See notes at end of table. Inches mm Inches mm .018 .02
7、3 .074 .077 .079 .082 .096 .187 0.46 0.58 1.88 1.95 2.01 2.08 2.44 4.75 .190 .192 .197 .250 .312 .320 .414 .440 4.83 4.88 5.00 6.35 7.92 8.13 10.51 11.18 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-39012/76D 3 TABLE I. Dash numbers, cross
8、-reference, and dimensions Continued. Dash No. M39012/76 # Applicable cable group from MIL-PRF-39012, appendix B M17/ Typical mating Connector 1/ Dimensions Inches (millimeters) Maximum 2/ CATEGORY A FIELD SERVICEABLE (NO SPECIAL TOOLS REQUIRED) 0104 3/ Cable group II 113-RG316 * 172-00001 % 94-RG17
9、9 M39012/73-0104 M39012/75-0104 A .88 (22.35) 0105 3/ M17/95-RG180 M39012/75-0105 4101 3/ Cable group I 93-RG178 * 169-00001 % M39012/73-4101 M39012/75-4101 4102 3/ Cable group II 113-RG316 * 172-00001 % 94-RG179 M39012/73-4102 M39012/75-4102 CATEGORY C FIELD REPLACEABLE (MIL-C-22520/5 CRIMP TOOL) 5
10、/ 0011 3/ 4/ Cable group I 93-RG178 * 169-00001 % M39012/73-0011 M39012/75-0011 A 1.20 (30.48) 0012 3/ 4/ Cable group IIa Example: M39012/68-3001 mates with M39012/67-3001, and M39012/68-4001 mates with M39012/67-4001. NOT FOR ARMY, NAVY, OR AIR FORCE USE. FOR OEM USE ONLY Provided by IHSNot for Res
11、aleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-39012/76D 10 TABLE V. Group qualification and retention testing. Group Submission and retention of Qualification of any of the following connectors 1/ M39012/ Qualifies the following connectors M39012/ I 74-0003 76-0003
12、74-0003 74-0103 2/ 76-0003 76-0103 2/ II 74-0004 76-0004 74-0004 74-0104 2/ 76-0004 76-0104 2/ III 74B0008 76B0008 74B0008 74B0014 2/ 76B0008 76B0014 2/ IV 74B0009 76B0009 74B0009 74B0010 74B0015 2/ 74B0016 2/ 76B0009 76B0010 76B0015 2/ 76B0016 2/ V 74B0010 76B0010 74B0010 74B0016 2/ 76B0010 76B0016
13、 2/ VI 74-0011 76-0011 74-0011 74-0017 2/ 76-0011 76-0017 2/ VII 74-0012 76-0012 74-0012 74-0018 2/ 76-0012 76-0018 2/ VIII 74-0013 76-0013 74-0013 76-0013 1/ Individual connectors other than listed are self qualifying only. 2/ Corrosion and contact resistance test data must be submitted to DSCC-VQ
14、before qualification approval may be granted. NOTES: 1. If a connector manufacturer produces a connector which meets all the requirements for two or more connector PINs (within the same series), the manufacturer may receive qualification approval for two or more connector PINs by qualifying the one
15、connector. It is not necessary that such connectors be in the same group. Each connector, however, must be marked with its own appropriate PIN. For group qualification, the connectors must be of similar design. 2. For qualification retention, where more than one part is listed in a group in this col
16、umn, data may be supplied on any of those parts in order to retain qualification for those parts in the corresponding right-hand column. The part does not necessarily have to be the part initially qualified. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IH
17、S-,-,-MIL-PRF-39012/76D 11 TABLE VI. Cross reference of PIN. Preferred PIN M39012/74 1/ Substitute for PIN or type designation -0003 -0004 B0008 B0009 B0010 M39012/74-0001 M39012/74-0002 M39012/74-0008, M39012/74-0005 M39012/74-0009, M39012/74-0006 M39012/74-0010, M39012/74-0007 1/ The “B” PIN is re
18、quired marking for connectors manufactured after 24 March 1987. The connectors that are in stock or distribution that were previously qualified and marked with the old PIN shall also be considered acceptable for Government use until stock is purged. (Applies to category “B” PIN change only; M39012/X
19、XBXXXX). Changes from previous issue. The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders
20、and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. Referenced documents. In addition to MIL-PRF-39012, this document references the following: MIL-STD-348 MIL-DTL-
21、22520 MIL-C-22520/5 MIL-STD-202 FED-STD-H28 ASTM B488 CONCLUDING MATERIAL Custodians: Preparing activity: Army - CR DLA - CC Navy - EC Air Force - 85 (Project 5935-2009-110) NASA - NA DLA - CC Review activities: Army - AT, AV, EA, MI Navy - AS, MC, OS, SH Air Force - 19, 99 NOTE: The activities list
22、ed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-